RESUMO
There is a strong scientific rationale to use nebulised unfractionated heparin (UFH) in treating patients with COVID-19. This pilot study investigated whether nebulised UFH was safe and had any impact on mortality, length of hospitalisation and clinical progression, in the treatment of hospitalised patients with COVID-19. This parallel group, open label, randomised trial included adult patients with confirmed SARS-CoV-2 infection admitted to two hospitals in Brazil. One hundred patients were planned to be randomised to either "standard of care" (SOC) or SOC plus nebulized UFH. The trial was stopped after randomisation of 75 patients due to falling COVID-19 hospitalisation rates. Significance tests were 1-sided test (10% significance level). The key analysis populations were intention to treat (ITT) and modified ITT (mITT) which excluded (from both arms) subjects admitted to ITU or who died within 24 h of randomisation. In the ITT population (n = 75), mortality was numerically lower for nebulised UFH (6 out of 38 patients; 15.8%) versus SOC (10 out of 37 patients; 27.0%), but not statistically significant; odds ratio (OR) 0.51, p = 0.24. However, in the mITT population, nebulised UFH reduced mortality (OR 0.2, p = 0.035). Length of hospital stay was similar between groups, but at day 29, there was a greater improvement in ordinal score following treatment with UFH in the ITT and mITT populations (p = 0.076 and p = 0.012 respectively), while mechanical ventilation rates were lower with UFH in the mITT population (OR 0.31; p = 0.08). Nebulised UFH did not cause any significant adverse events. In conclusion, nebulised UFH added to SOC in hospitalised patients with COVID-19 was well tolerated and showed clinical benefit, particularly in patients who received at least 6 doses of heparin. This trial was funded by The J.R. Moulton Charity Trust and registered under REBEC RBR-8r9hy8f (UTN code: U1111-1263-3136).
Assuntos
COVID-19 , Adulto , Humanos , Heparina/efeitos adversos , Projetos Piloto , SARS-CoV-2 , Hospitalização , Resultado do TratamentoRESUMO
AIMS: Inhaled nebulised unfractionated heparin (UFH) has a strong scientific and biological rationale that warrants urgent investigation of its therapeutic potential in patients with COVID-19. UFH has antiviral effects and prevents the SARS-CoV-2 virus' entry into mammalian cells. In addition, UFH has significant anti-inflammatory and anticoagulant properties, which limit progression of lung injury and vascular pulmonary thrombosis. METHODS: The INHALEd nebulised unfractionated HEParin for the treatment of hospitalised patients with COVID-19 (INHALE-HEP) metatrial is a prospective individual patient data analysis of on-going randomised controlled trials and early phase studies. Individual studies are being conducted in multiple countries. Participating studies randomise adult patients admitted to the hospital with confirmed SARS-CoV-2 infection, who do not require immediate mechanical ventilation, to inhaled nebulised UFH or standard care. All studies collect a minimum core dataset. The primary outcome for the metatrial is intubation (or death, for patients who died before intubation) at day 28. The secondary outcomes are oxygenation, clinical worsening and mortality, assessed in time-to-event analyses. Individual studies may have additional outcomes. ANALYSIS: We use a Bayesian approach to monitoring, followed by analysing individual patient data, outcomes and adverse events. All analyses will follow the intention-to-treat principle, considering all participants in the treatment group to which they were assigned, except for cases lost to follow-up or withdrawn. TRIAL REGISTRATION, ETHICS AND DISSEMINATION: The metatrial is registered at ClinicalTrials.gov ID NCT04635241. Each contributing study is individually registered and has received approval of the relevant ethics committee or institutional review board. Results of this study will be shared with the World Health Organisation, published in scientific journals and presented at scientific meetings.
Assuntos
COVID-19 , Heparina , Adulto , Teorema de Bayes , Humanos , Estudos Prospectivos , SARS-CoV-2 , Resultado do TratamentoRESUMO
In the present study a simple, fast, sensitive and robust method to quantify mirtazapine in human plasma using quetiapine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a simple protein precipitation with methanol and were analyzed by high-performance liquid chromatography coupled to an electrospray tandem triple quadrupole mass spectrometer (HPLC-ESI-MS/MS). Chromatography was performed isocratically on a C(18), 5 µm analytical column and the run time was 1.8 min. The lower limit of quantitation was 0.5 ng/mL and a linear calibration curve over the range 0.5-150 ng/mL was obtained, showing acceptable accuracy and precision. This analytical method was applied in a relative bioavailability study in order to compare a test mirtazapine 30 mg single-dose formulation vs a reference formulation in 31 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a 14 day washout period. Since the 90% confidence interval for C(max) , AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA (Brazilian Health Surveillance Agency), it was concluded that mirtazapine 30 mg/dose is bioequivalent to the reference formulation, according to both the rate and extent of absorption.
Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Mianserina/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Adulto , Área Sob a Curva , Disponibilidade Biológica , Estudos Cross-Over , Dibenzotiazepinas/sangue , Estabilidade de Medicamentos , Feminino , Humanos , Modelos Lineares , Masculino , Mianserina/sangue , Mianserina/química , Mianserina/farmacocinética , Pessoa de Meia-Idade , Mirtazapina , Fumarato de Quetiapina , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodosRESUMO
Background: Nitazoxanide exerts antiviral activity in vitro and in vivo and anti-inflammatory effects, but its impact on patients hospitalized with COVID-19 pneumonia is uncertain. Methods: A multicentre, randomized, double-blind, placebo-controlled trial was conducted in 19 hospitals in Brazil. Hospitalized adult patients requiring supplemental oxygen, with COVID-19 symptoms and a chest computed tomography scan suggestive of viral pneumonia or positive RT-PCR test for COVID-19 were enrolled. Patients were randomized 1:1 to receive nitazoxanide (500 mg) or placebo, 3 times daily, for 5 days, and were followed for 14 days. The primary outcome was intensive care unit admission due to the need for invasive mechanical ventilation. Secondary outcomes included clinical improvement, hospital discharge, oxygen requirements, death, and adverse events within 14 days. Results: Of the 498 patients, 405 (202 in the nitazoxanide group and 203 in the placebo group) were included in the analyses. Admission to the intensive care unit did not differ between the groups (hazard ratio [95% confidence interval], 0.68 [0.38-1.20], p = 0.179); death rates also did not differ. Nitazoxanide improved the clinical outcome (2.75 [2.21-3.43], p < 0.0001), time to hospital discharge (1.37 [1.11-1.71], p = 0.005), and reduced oxygen requirements (0.77 [0.64-0.94], p = 0.011). C-reactive protein, D-dimer, and ferritin levels were lower in the nitazoxanide group than the placebo group on day 7. No serious adverse events were observed. Conclusions: Nitazoxanide, compared with placebo, did not prevent admission to the intensive care unit for patients hospitalized with COVID-19 pneumonia. Clinical Trial Registration: Brazilian Registry of Clinical Trials (REBEC) RBR88bs9x; ClinicalTrials.gov, NCT04561219.
RESUMO
The validation of a high throughput and specific method using a high-performance liquid chromatography coupled to electrospray (ES+) ionization tandem triple quadrupole mass spectrometric (LC-ESI-MS/MS) method for ondansetron quantification in human plasma is described. Human plasma samples were extracted by liquid-liquid extraction (LLE) using methyl tert-butyl ether and analyzed by LC-ESI-MS/MS. The limit of quantification was 0.2 ng/mL and the method was linear in the range 0.2-60 ng/mL. The intra-assay precisions ranged from 1.6 to 7.7%, while inter-assay precisions ranged from 2.1 to 5.1%. The intra-assay accuracies ranged from 97.5 to 108.2%, and the inter-assay accuracies ranged from 97.3 to 107.0%. The analytical method was applied to evaluate the relative bioavailability of two pharmaceutical formulations containing 8 mg of ondansetron each in 25 healthy volunteers using a randomized, two-period crossover design. The geometric mean and respective 90% confidence interval (CI) of ondansetron test/reference percent ratios were 90.15% (81.74-99.44%) for C(max) and 93.11% (83.01-104.43%) for AUC(0-t). Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) and AUC(0-inf), it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of ondansetron.
Assuntos
Cromatografia Líquida/métodos , Ondansetron/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Disponibilidade Biológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ondansetron/farmacocinética , Sensibilidade e Especificidade , Adulto JovemRESUMO
In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 microm column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine, Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption.
Assuntos
Clorfeniramina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Disponibilidade Biológica , Clorfeniramina/farmacocinética , Clorfeniramina/farmacologia , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodosRESUMO
ABSTRACT BACKGROUND AND OBJECTIVES: The objective of this study was to assess the bioequivalence between two 200 mg celecoxib hard capsule formulations administered to healthy male and female participants under fasting conditions with the aim of providing an alternative pharmaceutical product to the reference drug, Celebra®. METHODS: A randomized, open label, single dose, 2x2 crossover trial was conducted with 60 adult healthy subjects under fasting conditions comparing single doses of two celecoxib hard capsules formulation. Pharmacokinetic parameters were calculated following the determination of drugs concentrations in human plasma using a validated liquid chromatography with a tandem mass spectrometer detector method (LC-MS/MS). RESULTS: Statistical analysis provided geometric mean of test/reference ratio, confidence intervals, intra-subject variation coefficient and power of the test to the pharmacokinetic parameters Cmax, AUC0-t, and AUC0-∞. Confidence intervals for the geometric mean (90% CI) of the test/reference drugs for celecoxib were 98.26 to 122.75% for Cmax, 100.27% to 110.78% for AUC0-t, and 96.87% to 110.29% for AUC0-∞. The power of the test found was 95.09% for Cmax, 100.00% for AUC0-t, and 99.99% for AUC0-∞. CONCLUSION: The formulations met the Brazilian standards for interchangeability, as the confidence intervals for Cmax and AUC0-t ratios are within the range of 80% to 125%, thus meeting the requirements of the legislation during market registration. The researched product was approved by the regulatory authorities and became a commercially competitive option to the reference product for the Brazilian population.
RESUMO JUSTIFICATIVA E OBJETIVOS: O objetivo deste estudo foi avaliar a bioequivalência entre duas formulações de cápsulas duras de celecoxibe de 200 mg administradas a participantes saudáveis do sexo masculino e feminino em condições de jejum com o objetivo de fornecer um produto farmacêutico alternativo ao fármaco de referência, Celebra®. MÉTODOS: Estudo randomizado, aberto, de dose única e cruzado 2x2. Foi conduzido com 60 indivíduos adultos saudáveis em condições de jejum, comparando doses únicas de duas formulações de cápsulas duras de celecoxibe. Os parâmetros farmacocinéticos foram calculados após a determinação das concentrações dos fármacos no plasma humano usando uma cromatografia líquida validada com um método detector de espectrômetro de massa em tandem (LC-MS/MS). RESULTADOS: A análise estatística forneceu a média geométrica da razão teste/referência, os intervalos de confiança, o coeficiente de variação intra-sujeito e o poder do teste para os parâmetros farmacocinéticos Cmáx, AUC0-t e AUC0-∞. Os intervalos de confiança para a média geométrica (IC 90%) dos fármacos teste/referência para o celecoxibe foram 98,26 a 122,75% para Cmáx, 100,27% a 110,78% para AUC0-t e 96,87% a 110,29% para AUC0-∞. O poder do teste encontrado foi de 95,09% para Cmáx, 100,00% para AUC0-t e 99,99% para AUC0-∞. CONCLUSÃO: As formulações atenderam aos padrões brasileiros de intercambialidade, pois os intervalos de confiança para as razões Cmáx e AUC0-t estão dentro da faixa de 80% a 125%, atendendo, assim, às exigências da legislação para o registro no mercado. O produto pesquisado foi aprovado pelas autoridades regulatórias e tornou-se uma opção comercialmente competitiva ao produto de referência para a população brasileira.
RESUMO
Introduction: Imatinib mesylate is currently the first-line oral treatment for all stages of chronic myeloid leukemia (CML) and is also used in some cases of gastrointestinal stromal tumor (GIST) and acute lymphoblastic leukemia (ALL). Objective: Investigate the bioavailability of two products containing imatinib mesylate, 100 mg coated tablet, to determine if they are bioequivalent. Method: The study was conducted using an open-label, randomized, balanced design and the formulations were administered orally in a single dose to 48 healthy adult males, in fed state, followed by sequential blood withdraws for the next 72 hours. Forty-eight male healthy volunteers were selected to participate in the study. Test formulation from Eurofarma Laboratórios S.A. Brazil was compared to from Novartis Biociências S.A. The comparative bioavailability of the formulations was assessed based on statistical comparisons of relevant pharmacokinetic parameters obtained from drug concentration data from collected blood samples measured using an analytical method based on high-performance liquid chromatography coupled to mass spectrometry. Results: The ratio of the geometric means between the test and the reference, with a 90% confidence interval, of pharmacokinetic parameters for Cmax was 102.26% (94.17-111.04%) and for AUC0-t was 101.24% (95.19-107.68%). Conclusion: Imatinib mesylate 100 mg (test product) from Eurofarma Laboratórios S.A. was considered bioequivalent to the reference Glivec® 100 mg manufactured by Novartis Biociências S.A, and the test product can be interchangeable with the reference, based on their pharmacokinetic performance
Introdução: O mesilato de imatinibe é atualmente o tratamento oral de primeira linha para todos os estágios de leucemia mieloide crônica (LMC) e é usado também em alguns casos de tumores gastrointestinais (GIST) e na leucemia linfoide aguda (LLA). Objetivo: Investigar a biodisponibilidade de dois produtos contendo mesilato de imatinibe de 100 mg em comprimidos revestidos para determinar se são bioequivalentes. Método: Estudo conduzido usando um desenho aberto, randomizado e balanceado. As formulações foram administradas de forma oral em única dose a 48 participantes saudáveis do sexo masculino após alimentação, seguido de coletas de sangue por 72 horas. Quarenta e oito participantes saudáveis foram selecionados para participar do estudo. A formulação teste da Eurofarma Laboratórios S.A. foi comparada com a formulação referência da Novartis Biociências S.A. A biodisponibilidade relativa das formulações foi avaliada em comparações estatísticas dos parâmetros farmacocinéticos relevantes obtidos de concentrações de droga das amostras coletadas mediante a utilização de um método analítico baseado em cromatografia líquida de alta performance acoplada à espectrometria de massas. Resultados: A razão das médias geométricas entre teste e referência com intervalo de confiança 90% dos parâmetros farmacocinéticos para Cmáx foi de 102,26% (94,17-111,04%) e para ASC0-t foi de 101,24% (95,19-107,68). Conclusão: Mesilato de imatinib 100 mg (produto teste) da Eurofarma Laboratórios S.A. foi considerado bioequivalente ao Glivec® 100 mg produzido por Novartis Biociências S.A., e o produto teste pode ser intercambiável como referência com base em seu desempenho farmacocinético
Introducción: El mesilato de imatinibe es actualmente el tratamiento oral de primera línea para todos los estadios de leucemia mieloide crónica (LMC) y es usado también en algunos casos de tumores gastrointestinales (GIST) y leucemia linfoide aguda (LLA). Objetivo: Investigar la biodisponibilidad de dos productos de mesilato de imatinibe de 100 mg en comprimidos revestidos para determinar si son bioequivalentes. Método: Estudio ejecutado usando un diseño abierto, aleatorizado y balanceado. Las formulaciones fueron administradas de forma oral en dosis única a 48 participantes saludables de sexo masculino en condiciones de alimentación, seguidas de muestras de sangre por 72 horas. Cuarenta y ocho participantes saludables fueron seleccionados para participar del estudio. La formulación de prueba de Eurofarma Laboratórios S.A. fue comparada con la formulación referencia de Novartis Biociências S.A. La biodisponibilidad relativa de las formulaciones fue evaluada mediante comparaciones estadísticas de los parámetros farmacocinéticos relevantes obtenidos de concentraciones del fármaco de muestras recolectadas con la utilización de un método analítico basado en cromatografía de alto rendimiento acoplada a espectrometría de masas. Resultados: La relación de las medias geométricas entre la prueba y la referencia con un intervalo de confianza del 90% de los parámetros farmacocinéticos para Cmax fue 102,26% (94,17-111,04%) y para AUC0-t fue 101,24% (95,19-107,68). Conclusión: El mesilato de imatinib 100 mg (producto de prueba) de Eurofarma Laboratórios S.A. fue considerado bioequivalente al Glivec® 100 mg producido por Novartis Biociências S.A. y el producto de prueba puede ser intercambiable con el de referencia en función de su desempeño farmacocinético
Assuntos
Humanos , Masculino , Equivalência Terapêutica , Espectrometria de Massas em Tandem , Mesilato de Imatinib , Inibidores de Tirosina QuinasesRESUMO
Introduction: Montelukast, a selective and active leukotriene receptor antagonist, is one of the most common agents in asthma treatment for both adults and children. Objective: To assess whether the pharmacokinetic profiles of two formulations of montelukast were similar after a single 5 mg dose (chewable tablets), administered orally under fasting conditions, sampling blood before and 36 hours after administration. Methods: This was a randomized, 2-sequence, 2-period, crossover study of 2 chewable tablet formulations of the drug: Singulair®, provided by Merck Sharp and Dohme Farmacêutica Ltda. (reference), and generic montelukast, manufactured by Eurofarma Laboratórios S.A. (test). Plasma samples obtained from 35 participants were analyzed for montelukast through high-performance liquid chromatography coupled to tandem mass spectrometry, with montelukast-d6 as the internal standard. Peak montelukast concentrations were 299.313 (SD, 11.039) ng/mL for the reference formulation and 279.803 (SD, 10.085) ng/mL for test formulation. Results: Statistical analysis showed no significant differences between AUC0-36h, AUC0-inf, or Cmax between formulations, with the following test/reference ratios: 102.458 for AUC0-36h, 102.522 for AUC0-inf, and 93.490 for Cmax. No serious adverse events were reported during the trial. Our results demonstrated the bioequivalence of Singulair® and Eurofarma's generic montelukast. Conclusions: Our results revealed that the new generic tablets are clinically safe and can be used interchangeably with the brand name product. Eurofarma's montelukast offers a safe, effective, and cheaper treatment option for people with asthma or allergic rhinitis.
Introdução: O montelucaste, um antagonista seletivo e ativo dos receptores de leucotrienos, é um dos agentes mais comumente usados na prática clínica no tratamento da asma, tanto em adultos quanto em crianças. Objetivo: Avaliar se os perfis farmacocinéticos de duas formulações de montelucaste eram semelhantes após uma dose única de comprimidos mastigáveis de 5 mg, administrados por via oral em jejum, coletando amostras de sangue desde antes da administração até 36 horas depois disso. Métodos: Estudo comparativo randomizado, 2 sequências e 2 períodos, cruzado, de dois medicamentos em comprimidos mastigáveis: Singulair®, fornecido pela Merck Sharp e Dohme Farmacêutica Ltda. (referência) e Montelucaste 5 mg, fabricado pela Eurofarma Laboratórios S.A. (teste). Amostras de plasma obtidas de 35 indivíduos elegíveis foram analisadas para montelucaste por cromatografia líquida de alta eficiência acoplada a espectrometria de massa em tandem, tendo Montelucaste-d6 como padrão interno. As concentrações máximas de montelucaste foram 299,313±11,039 ng/mL para referência e 279,803±10,085 ng/mL para formulação de teste. Resultados: A análise estatística não mostrou diferenças significativas para AUC0-36h, AUC0-inf e nem para Cmax entre as formulações, apresentando as razões Teste/Referência: 102,458 para AUC0-36h, 102,522 para AUC0-inf e 93,490 para Cmax. Nenhum evento adverso grave foi relatado durante o estudo. De acordo com a regulamentação brasileira, o atual estudo farmacocinético demonstrou bioequivalência entre os agentes individuais e forneceu evidências de bioequivalência entre Singulair® e Montelukast fabricado pela Eurofarma. Resultado: Os resultados mostraram que os novos comprimidos genéricos são clinicamente seguros e podem ser trocados pela marca original. O montelucaste da Eurofarma oferece uma opção de tratamento mais barata, segura e eficaz para indivíduos com asma ou rinite alérgica.
Assuntos
Humanos , Adolescente , Adulto , Pessoa de Meia-IdadeRESUMO
In the present study, a novel, fast, sensitive and robust method to quantify clozapine in human plasma using quetiapine as the internal standard (IS) is described. The analyte and the IS were extracted from plasma using a single protein precipitation extraction technique with methanol and analyzed by high performance liquid chromatography coupled to the electrospray ionization tandem mass spectrometric (HPLC-ESI-MS/MS). The method was linear over the range 20 to 1500 ng.mL-1. The intra-assay precisions ranged from 3.8 to 5.9%, while inter-assay precisions ranged from 4.2 to 6.0%. The intra-assay accuracies ranged from 99.3 to 107.5%, while the inter-assay accuracies ranged from 98.9 to 101.7%. This method agrees with the requirements proposed by the US Food and Drug Administration of high sensitivity, specificity and high sample throughput and was used to evaluate the pharmacokinetic profiles and bioequivalence of the two clozapine formulations in twenty six schizophrenic patients affected by refractory schizophrenia under steady-state conditions. During the hospitalization period the patients received the 100 mg clozapine formulation tablets corresponding to the same dose they were using 14 days before hospitalization. The clozapine pharmacokinetic did not differ significantly after administration of both test and the reference formulations. The Tmax and T1/2 for the test formulation were 2.26 and 10.92 h, respectively. In addition, the Tmax and T1/2 for the reference formulation were 2.44 and 11.08 h, respectively. The 90% confidence interval of the mean ratio of lnAUC0-t was within 0.80-1.25 range which indicates that the test formulation was bioequivalent to the reference formulation when orally administered to schizophrenic patients regarding both the rate and extent of absorption.
Assuntos
Antipsicóticos/farmacocinética , Clozapina/farmacocinética , Esquizofrenia/tratamento farmacológico , Administração Oral , Antipsicóticos/administração & dosagem , Antipsicóticos/efeitos adversos , Disponibilidade Biológica , Cromatografia Líquida de Alta Pressão , Clozapina/administração & dosagem , Clozapina/efeitos adversos , Estudos Cross-Over , Humanos , Espectrometria de Massas em TandemRESUMO
OBJETIVO: Avaliar a bioequivalência de duas formulações de cloridrato de propafenona 300mg em comprimido revestido.MÉTODOS: Estudo randomizado, cruzado, aberto, com dois tratamentos, duas sequências e quatro períodos com 60 participantes sadios de ambos os sexos. Os voluntários foram internados em quatro oportunidades durante 24 horas; em cada período, os sujeitos receberam a formulação teste ou a formulação referência, em regime pós-prandial. Foram coletadas 23 amostras de sangue após administração da droga para determinação plasmática da propafenona. Para quantificação da droga, foi utilizada técnica de cromatografia líquida acoplada à espectrometria de massas sequencial. RESULTADOS: As formulações foram consideradas clinicamente bem toleradas. A concentração máxima e a área sob a curva de zero a 36 horas foram comparadas: a média geométrica da razão entre as formulações teste e referência para concentração máxima foi de 110,16%, com intervalo de confiança de 99,44% a 122,04% e coeficiente de variação de 33,95%. A média geométrica da razão entre as formulações teste e referência para a área sob a curva de zero a 36 horas foi de 107,92%, com intervalo de confiança de 99,58% a 116,96% e coeficiente de variação de 26,39%. A média geométrica da razão entre o medicamento teste e referência para área sob a curva de zero ao infinito foi de 107,12%, com intervalo de confiança de de 99,11% a 115,78% e coeficiente de variação de 25,48%. CONCLUSÃO: As formulações teste e referência foram estatisticamente bioequivalentes, de acordo com sua taxa e extensão de absorção.
OBJECTIVE: To evaluate the bioequivalence of two 300mg profanone hydrochloride coated tablets. METHODS: Randomized, cross-over, openstudy, with two treatments, two sequences, and four periods with 60 healthy participants of both genders. The volunteers were admitted in four opportunities over 24 hours; on each period, the subjects received a test formulation, or a reference formulation, in a postprandial administration. Twenty-three samples of blood were collected after oral administration of the drug for determining plasma level of propafenone. Liquid chromatography-mass spectrometry was used for quantifying propafenone. RESULTS: The formulations were considered clinically well tolerated. The maximum concentration and the area under the curve from zero to 36 hours were compared: the geometric mean of the ratio between the test and reference formulations for maximum concentration was 110.16%, with confidence interval of 99.44% - 122.04%), coefficient of variation of 33.95%. The geometric mean of the ratio between the test and reference formulations for the area under the curve of zero to 36 hours was 107.92%, with confidence interval of 99.58% - 116.96%, and coefficient of variation of 26.39%. The geometric mean of the ratio between the formulations for area under the curve of zero to infinitum as 107.12% with confidence interval of 99.11% - 115.78%),and coefficient of variation of 25.48%. CONCLUSION: According to the rate and extension of absorption, the test and reference formulations are statistically bioequivalent.
Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Antiarrítmicos , Período Pós-Prandial/efeitos dos fármacos , Propafenona/administração & dosagem , Propafenona/farmacocinética , SangueRESUMO
In the present study, a novel, fast, sensitive and robust method to quantify budesonide in human plasma using 3-keto-desogestrel as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by liquid-liquid extraction (LLE) using ether. Extracted samples were analyzed by high performance liquid chromatography coupled to Atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 µm analytical column. The temperature of the autosampler was kept at 6 °C and the run time was 4.00 min. A linear calibration curve over the range 7.5-1000 pg ml⻹ was obtained and the lowest concentration quantified was 7.5 pg ml⻹, demonstrating acceptable accuracy and precision. This analytical method was applied in a relative bioavailability study in order to compare a test budesonide 64 µg/dose nasal spray formulation vs. a reference 64 µg/dose nasal spray formulation (Budecort Aqua) in 48 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a one-week washout period. Plasma samples were obtained over a 14 h interval. Since the 90% CI for both C(max), AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA, it was concluded that budesonide 64 µg/dose nasal spray was bioequivalent to Budecort Acqua® 64 µg/dose nasal spray, according to both the rate and extent of absorption.
Assuntos
Budesonida/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Disponibilidade Biológica , Broncodilatadores/administração & dosagem , Broncodilatadores/sangue , Broncodilatadores/farmacocinética , Budesonida/administração & dosagem , Budesonida/sangue , Estudos Cross-Over , Desogestrel/sangue , Estabilidade de Medicamentos , Feminino , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Sprays Nasais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Equivalência TerapêuticaRESUMO
In the present study, a novel, fast, sensitive and robust method to quantify ethinylestradiol in human plasma using 17alpha-ethinylestradiol-d4 as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction (LLE) using diethyl ether-hexane followed by online solid phase extraction (SPE) using online C18 cartridges. Extracted samples were analyzed by high-performance liquid chromatography coupled to atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 microm analytical column. The method had a chromatographic run time of 2.50 min and a linear calibration curve over the range 5-500 pg ml(-1) (r(2)>0.9992). The lowest concentration quantified was 5 pg ml(-1), demonstrating acceptable accuracy and precision. The intra-assay precisions ranged from 2.1 to 14.6%, while inter-assay precisions ranged from 4.4 to 11.4%. The intra-assay accuracies ranged from 94.6 to 103.8%, while the inter-assay accuracies ranged from 98.9 to 101.6%. The recovery of ethinylestradiol was determined as part of the assay validation process and was 73.1 and 79.0% for the concentrations 15 and 375 pg ml(-1), respectively. Short-term stability showed that ethinylestradiol was stable in plasma for at least 19 h at room temperature or for at least 385 days when stored at -20 degrees C. In the study of bioequivalence conducted in Brazil, healthy volunteers received two ethinylestradiol 0.035 mg tablet formulations using an open, randomized, two-period crossover design with a 2-week washout interval. Since the 90% confidence interval for C(max) and area under the curve ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the two ethinylestradiol formulations are bioequivalent with respect to both the rate and the extent of absorption.
Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Etinilestradiol/sangue , Etinilestradiol/farmacocinética , Espectrometria de Massas em Tandem/métodos , Humanos , Reprodutibilidade dos TestesRESUMO
A specific, fast and sensitive high performance liquid chromatography (HPLC) coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometric (LC-MS/MS) assay was developed for the determination of cyproterone (CYP) acetate (CAS 427-51-0) in human plasma. The retention times were 3.26 and 2.90 min for CYP acetate and its internal standard (I. S.) finasteride (FIN), respectively. The overall mean recovery, using liquid/liquid extraction, was found to be 109.0, 107.7 and 100.3%, for low, medium and high concentrations, respectively. Calibration curves were linear in the concentration range of 0.1-50.0 ng/ml, and the lower limit of quantification (LLOQ) was 0.1 ng/ml. The LLOQ, 0.1 ng/ml, was sensitive enough for detecting terminal phase concentrations of the drug. Inter-batch precision of the method ranged from 2.2 to 5.55%, while Inter-batch accuracy ranged from 95.5 to 100.0%. Intra-batch precision ranged from 1.8 to 5.6%, while Intra-batch accuracy ranged from 92.0 to 99.4% at concentrations of 0.3 ng/ml, 20.0 and 40.0 ng/ml. The developed method was applied to a bioequivalenc study of CYP acetate in a group of 44 female volunteers at a single oral dose of a 2 mg tablet, in a combination of ethinylestradiol/CYP acetate (0.25/2 mg). The plasma concentration of CYP acetate did not differ significantly after administration of both formulations (test formulation and the reference one). The geometric mean and respective 90% CI of CYP acetate test/reference percent ratios were 90.66% (84.39-97.40%) for Cmax and 96.20% (90.45-102.33%) for AUC0-t.