Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Biomech ; 40(9): 2063-70, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17399722

RESUMO

In vitro tissue culture experiments were performed to study the biomechanical response of collagen fascicles to restressing after exposure to non-loaded condition. Collagen fascicles of approximately 300 microm in diameter were aseptically dissected from rabbit patellar tendons. They were cultured under no-load condition for 1 week, and then under a static stress of approximately 1.2 MPa for the subsequent 1 or 2 weeks. After culture, their mechanical properties were determined with a micro-tensile tester, and were compared to those of fascicles cultured under no-load condition and non-cultured, control fascicles. Tangent modulus and tensile strength of the non-loaded fascicles were significantly lower than those of the control fascicles at 1 week and gradually decreased thereafter. However, the modulus and strength were increased by restressing. After 2-week restressing, both parameters were significantly greater than those of the time-matched, non-loaded fascicles, although these values were still significantly lower than those of the control fascicles. That is, the application of stress after exposure to non-loaded condition suppressed the deterioration of the biomechanical properties of fascicles, although it did not improve. These results indicate that a short period of stressing is not sufficient for cultured collagen fascicles to completely recover their mechanical properties, if they are once exposed to no-stress condition even for a short period of time. These are similar to previous results observed in tendons and ligaments inside the body.


Assuntos
Fenômenos Biomecânicos , Colágeno/fisiologia , Animais , Sobrevivência Celular/fisiologia , Células Cultivadas , Feminino , Coelhos , Estresse Mecânico
2.
Sci Rep ; 7: 42783, 2017 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-28218292

RESUMO

We previously reported that µ-oxo N,N'-bis(salicylidene)ethylenediamine iron [Fe(Salen)], a magnetic organic compound, has direct anti-tumor activity, and generates heat in an alternating magnetic field (AMF). We showed that Fe(Salen) nanoparticles are useful for combined hyperthermia-chemotherapy of tongue cancer. Here, we have examined the effect of Fe(Salen) on human glioblastoma (GB). Fe(Salen) showed in vitro anti-tumor activity towards several human GB cell lines. It inhibited cell proliferation, and its apoptosis-inducing activity was greater than that of clinically used drugs. Fe(Salen) also showed in vivo anti-tumor activity in the mouse brain. We evaluated the drug distribution and systemic side effects of intracerebrally injected Fe(Salen) nanoparticles in rats. Further, to examine whether hyperthermia, which was induced by exposing Fe(Salen) nanoparticles to AMF, enhanced the intrinsic anti-tumor effect of Fe(Salen), we used a mouse model grafted with U251 cells on the left leg. Fe(Salen), BCNU, or normal saline was injected into the tumor in the presence or absence of AMF exposure. The combination of Fe(Salen) injection and AMF exposure showed a greater anti-tumor effect than did either Fe(Salen) or BCNU alone. Our results indicate that hyperthermia and chemotherapy with single-drug nanoparticles could be done for GB treatment.


Assuntos
Antineoplásicos/administração & dosagem , Neoplasias Encefálicas/terapia , Etilenodiaminas/administração & dosagem , Glioblastoma/terapia , Hipertermia Induzida/métodos , Animais , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Etilenodiaminas/farmacologia , Humanos , Camundongos , Nanopartículas , Ratos , Resultado do Tratamento , Ensaios Antitumorais Modelo de Xenoenxerto
3.
J Biomech Eng ; 127(7): 1168-75, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16502659

RESUMO

The effects of frequency or duration of cyclic stress on the mechanical properties of collagen fascicles were studied by means of in vitro tissue culture experiments. Collagen fascicles of approximately 300 microm in diameter were obtained from rabbit patellar tendons. During culture, cyclic stress having the peak stress of approximately 2 MPa was applied to the fascicles at 1 Hz for 1 hour/day (1 Hz-1 h group), at 1 Hz for 4 hours/day (1 Hz-4 h group), or at 4 Hz for 1 hour/day (4 Hz-1 h group). The frequency of 4 Hz and the duration of 1 hour/day are considered to be similar to those of the in vivo stress applied to fascicles in the intact rabbit patellar tendon. After culture for 1 or 2 weeks, the mechanical properties of the fascicles were determined using a microtensile tester, and were compared to the properties of non-cultured, fresh fascicles (control group) and the fascicles cultured under no load condition (non-loaded group). The tangent modulus and tensile strength of fascicles in the 4 Hz-1 h group were similar to those in the control group; however, the fascicles of the 1 Hz-1 h and 1 Hz-4 h groups had significantly lower values than those of the control group. There was no significant difference in the tensile strength between the 1 Hz-1 h and non-loaded groups, although the strength in the 1 Hz-4 h group was significantly higher than that of the non-loaded group. It was concluded that the frequency and duration of cyclic stress significantly affect the mechanical properties of cultured collagen fascicles. If we apply cyclic stress having the frequency and duration which are experienced in vivo, the biomechanical properties are maintained at control, normal level. Lower frequencies or less cycles of applied force induce adverse effects.


Assuntos
Colágenos Fibrilares/fisiologia , Mecanotransdução Celular/fisiologia , Patela/fisiologia , Ligamento Patelar/fisiologia , Estimulação Física/métodos , Tendões/fisiologia , Animais , Células Cultivadas , Força Compressiva/fisiologia , Elasticidade , Feminino , Oscilometria/métodos , Periodicidade , Coelhos , Estresse Mecânico , Resistência à Tração/fisiologia
4.
J Biomech Eng ; 125(6): 893-901, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14986416

RESUMO

Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 microns in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo.


Assuntos
Colágeno/fisiologia , Colágeno/ultraestrutura , Mecanotransdução Celular/fisiologia , Ligamento Patelar/citologia , Ligamento Patelar/fisiologia , Resistência à Tração/fisiologia , Suporte de Carga/fisiologia , Adaptação Fisiológica/fisiologia , Animais , Sobrevivência Celular/fisiologia , Células Cultivadas , Elasticidade , Feminino , Periodicidade , Coelhos , Estresse Mecânico , Tendões/citologia , Tendões/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA