Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Radiat Prot Dosimetry ; 114(1-3): 359-63, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15933137

RESUMO

A computer model of X-ray mammography has been developed, which uses quasi-realistic high-resolution voxel phantoms to simulate the breast. The phantoms have 400 microm voxels and simulate the three-dimensional distributions of adipose and fibro-glandular tissues, Cooper's ligaments, ducts and skin and allow the estimation of dose to individual tissues. Calculations of the incident air kerma to mean glandular dose conversion factor, g, were made using a Mo/Mo spectrum at 28 kV for eight phantoms in the thickness range 40-80 mm and of varying glandularity. The values differed from standard tabulations used for breast dosimetry by up to 43%, because of the different spatial distribution of glandular tissue within the breast. To study this further, additional voxel phantoms were constructed, which gave variations of between 9 and 59% compared with standard values. For accurate breast dosimetry, it is therefore very important to take the distribution of glandular tissues into account.


Assuntos
Mamografia/métodos , Radiometria/métodos , Mama/patologia , Feminino , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Raios X
2.
Radiat Prot Dosimetry ; 114(1-3): 395-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15933144

RESUMO

A Monte Carlo computer model of mammography has been developed to study and optimise the performance of digital mammographic systems. The program uses high-resolution voxel phantoms to model the breast, which simulate the adipose and fibroglandular tissues, Cooper's ligaments, ducts and skin in three dimensions. The model calculates the dose to each tissue, and also the quantities such as energy imparted to image pixels, noise per image pixel and scatter-to-primary (S/P) ratios. It allows studies of the dependence of image properties on breast structure and on position within the image. The program has been calibrated by calculating and measuring the pixel values and noise for a digital mammographic system. The thicknesses of two components of this system were unknown, and were adjusted to obtain a good agreement between measurement and calculation. The utility of the program is demonstrated with the calculations of the variation of the S/P ratio with and without a grid, and of the image contrast across the image of a 50-mm-thick breast phantom.


Assuntos
Mamografia/instrumentação , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tecido Adiposo/diagnóstico por imagem , Artefatos , Mama/patologia , Simulação por Computador , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Pele/diagnóstico por imagem , Software
3.
Radiat Prot Dosimetry ; 114(1-3): 432-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15933151

RESUMO

A test phantom, including a wide range of mammographic tissue equivalent materials and test details, was imaged on a digital mammographic system. In order to quantify the effect of scatter on the contrast obtained for the test details, calculations of the scatter-to-primary ratio (S/P) have been made using a Monte Carlo simulation of the digital mammographic imaging chain, grid and test phantom. The results show that the S/P values corresponding to the imaging conditions used were in the range 0.084-0.126. Calculated and measured pixel values in different regions of the image were compared as a validation of the model and showed excellent agreement. The results indicate the potential of Monte Carlo methods in the image quality-patient dose process optimisation, especially in the assessment of imaging conditions not available on standard mammographic units.


Assuntos
Mamografia/instrumentação , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tecido Adiposo/diagnóstico por imagem , Mama/patologia , Doenças Mamárias/diagnóstico , Feminino , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Espalhamento de Radiação , Ecrans Intensificadores para Raios X
4.
Orthopedics ; 7(5): 872-3, 1984 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24822482

RESUMO

An intraneural cyst is a rare condition. This paper describes one such case, discusses the clinical picture and possible etiology, and reviews the methods of treatment reported in the literature.

5.
Philos Trans R Soc Lond B Biol Sci ; 368(1611): 20120025, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23267179

RESUMO

We have developed a method combining microfluidics, time-lapsed single-molecule microscopy and automated image analysis allowing for the observation of an excess of 3000 complete cell cycles of exponentially growing Escherichia coli cells per experiment. The method makes it possible to analyse the rate of gene expression at the level of single proteins over the bacterial cell cycle. We also demonstrate that it is possible to count the number of non-specifically DNA binding LacI-Venus molecules using short excitation light pulses. The transcription factors are localized on the nucleoids in the cell and appear to be uniformly distributed on chromosomal DNA. An increase in the expression of LacI is observed at the beginning of the cell cycle, possibly because some gene copies are de-repressed as a result of partitioning inequalities at cell division. Finally, a size-growth rate uncertainty relation is observed where cells living in rich media vary more in the length at birth than in generation time, and the opposite is true for cells living in poorer media.


Assuntos
Escherichia coli/química , Regulação Bacteriana da Expressão Gênica , Técnicas Analíticas Microfluídicas/métodos , Nefelometria e Turbidimetria/métodos , Proteínas de Bactérias/química , Ciclo Celular , Rastreamento de Células/métodos , Cromossomos/química , DNA Bacteriano/química , Escherichia coli/genética , Proteínas de Escherichia coli/química , Genes Bacterianos , Ensaios de Triagem em Larga Escala , Processamento de Imagem Assistida por Computador , Repressores Lac/química , Funções Verossimilhança , Proteínas de Membrana/química , Proteínas Quimiotáticas Aceptoras de Metil , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Microfluídica/métodos , Proteínas de Transporte de Monossacarídeos/química , Simportadores/química , Imagem com Lapso de Tempo/métodos , Fatores de Transcrição/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA