Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 198
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 31(25): 41202-41218, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38087525

RESUMO

Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Conventional OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bond-selective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect, achieving label-free bond-selective 3D sectioned imaging of highly scattering samples. We first demonstrate BS-FF-OCT imaging of 1 µm PMMA beads embedded in agarose gel. Next, we show 3D hyperspectral imaging of up to 75 µm of polypropylene fiber mattress from a standard surgical mask. We then demonstrate BS-FF-OCT imaging on biological samples, including cancer cell spheroids and C. elegans. Using an alternative pulse timing configuration, we finally demonstrate the capability of BS-FF-OCT on imaging a highly scattering myelinated axons region in a mouse brain tissue slice.


Assuntos
Caenorhabditis elegans , Tomografia de Coerência Óptica , Animais , Camundongos , Tomografia de Coerência Óptica/métodos , Imageamento Tridimensional
2.
Sensors (Basel) ; 23(11)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37299745

RESUMO

Viral infections can pose a major threat to public health by causing serious illness, leading to pandemics, and burdening healthcare systems. The global spread of such infections causes disruptions to every aspect of life including business, education, and social life. Fast and accurate diagnosis of viral infections has significant implications for saving lives, preventing the spread of the diseases, and minimizing social and economic damages. Polymerase chain reaction (PCR)-based techniques are commonly used to detect viruses in the clinic. However, PCR has several drawbacks, as highlighted during the recent COVID-19 pandemic, such as long processing times and the requirement for sophisticated laboratory instruments. Therefore, there is an urgent need for fast and accurate techniques for virus detection. For this purpose, a variety of biosensor systems are being developed to provide rapid, sensitive, and high-throughput viral diagnostic platforms, enabling quick diagnosis and efficient control of the virus's spread. Optical devices, in particular, are of great interest due to their advantages such as high sensitivity and direct readout. The current review discusses solid-phase optical sensing techniques for virus detection, including fluorescence-based sensors, surface plasmon resonance (SPR), surface-enhanced Raman scattering (SERS), optical resonators, and interferometry-based platforms. Then, we focus on an interferometric biosensor developed by our group, the single-particle interferometric reflectance imaging sensor (SP-IRIS), which has the capability to visualize single nanoparticles, to demonstrate its application for digital virus detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Vírus , Humanos , COVID-19/diagnóstico , Pandemias , Técnicas Biossensoriais/métodos , Ressonância de Plasmônio de Superfície/métodos
3.
Acta Orthop Belg ; 89(4): 603-608, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38205748

RESUMO

This study aimed to describe a surgical procedure for the management of corticosteroid-induced osteonecrosis of the femoral head (ONFH) and report its clinical results. The technique included harvesting a bone plug from the lateral femoral neck, core decompression, and bone marrow aspirate concentrate (BMAC) application; the procedure was completed by press-fit insertion of the autologous bone plug in the debrided area. Autologous bone plug-sliding with core decompression and bone marrow concentrate aspirate application provides good clinical outcomes in the management of ONFH. A retrospective review was performed using records of patients operated on between October 2019 and June 2021. Only patients with Ficat-Arlet stage-2 ONFH, who underwent the procedure described, were included. Twenty- nine hips (18 patients) were included and evaluated clinically and radiologically. Clinical evaluation included the Harris hip score (HHS) and Visual analogue scale (VAS) for pain, while radiological evaluation included direct radiographs. The average age was 39.8 years (± 11.7, range: 24-65 years). The average follow-up was 13.5 months (± 3.4, range: 8-19 months). There were improvements in the VAS pain and Harris hip scores in all patients. Average HHS increased from 61.90 to 87.45 (p < 0.001), while the average VAS pain score decreased from 7.14 to 3.27 (p < 0.001). No complications were encountered in any of the patients during the follow-up. None of the patients had femoral head collapse on the latest radiograph or required total hip replacement. The combination of the novel autologous bone plug-sliding method with conventional regenerative methods is a successful treatment choice for ONFH.


Assuntos
Medula Óssea , Osteonecrose , Humanos , Adulto , Cabeça do Fêmur/cirurgia , Corticosteroides , Dor , Descompressão
4.
Acta Endocrinol (Buchar) ; 19(2): 208-214, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37908877

RESUMO

Context: Primary hyperparathyroidism is one of the most common endocrinological disorder and surgery of parathyroid glands is the main therapy of this disease. Minimally invasive surgery is getting more prominent in these days and its success in parathyroid surgery mostly depends on accuracy of the localization studies. Objective: The aim of this study is to understand the relationship between preoperative biochemical tests, intraoperative findings and Technetium-99m-methoxyisobutylisonitrile (MIBI) scan results. Design: Retrospective clinical study. Subjects and Methods: A total of 185 patients, who have been diagnosed with primary hyperparathyroidism (PHPT) and operated between January, 2010 and October, 2018, were included to the study. Patients with less than 6 months of follow up are excluded from the study. Results: Patients were divided into two groups according to their scintigraphy results; with positive scintigraphy findings as group 1 (n:135) and negative scintigraphy findings as group 2 (n:50). Mean preoperative serum parathyroid hormone (PTH) values were significantly different between the two groups (p<0.02). Mean preoperative serum calcium, creatinine, magnesium, phosphorus, alkaline phosphatase, 25-OH Vitamin D3 levels of both groups were analyzed and there were no statistical differences between the two groups considering these parameters. Also, mean diameter and mean volume of parathyroid adenomas were significantly higher in group 1 (2.1±1.0 cm vs. 1.55±0.72 cm, respectively, p<0.0001; 2.66±5.35 cm3 vs. 1±1.9 cm3, respectively, p<0.0001). Optimal cut-off values of parathyroid adenoma diameter for MIBI scan positivity were 1.55 cm, parathyroid volume for MIBI scan positivity were 0.48 cm3, preoperative serum PTH for MIBI scan positivity were 124.5 ng/L. Conclusions: Preoperative serum PTH levels, diameter and volume of adenomas might be helpful for the prediction of MIBI scan accuracy and possible need of another localization studies.

5.
Proc Natl Acad Sci U S A ; 116(10): 4129-4134, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30782809

RESUMO

The clinical need for ultrasensitive molecular analysis has motivated the development of several endpoint-assay technologies capable of single-molecule readout. These endpoint assays are now primarily limited by the affinity and specificity of the molecular-recognition agents for the analyte of interest. In contrast, a kinetic assay with single-molecule readout could distinguish between low-abundance, high-affinity (specific analyte) and high-abundance, low-affinity (nonspecific background) binding by measuring the duration of individual binding events at equilibrium. Here, we describe such a kinetic assay, in which individual binding events are detected and monitored during sample incubation. This method uses plasmonic gold nanorods and interferometric reflectance imaging to detect thousands of individual binding events across a multiplex solid-phase sensor with a large area approaching that of leading bead-based endpoint-assay technologies. A dynamic tracking procedure is used to measure the duration of each event. From this, the total rates of binding and debinding as well as the distribution of binding-event durations are determined. We observe a limit of detection of 19 fM for a proof-of-concept synthetic DNA analyte in a 12-plex assay format.


Assuntos
Técnicas Biossensoriais , DNA/análise , Ouro/química , Nanopartículas Metálicas/química , Nanotubos/química , Interferometria
6.
Anal Chem ; 93(8): 4100-4107, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33596049

RESUMO

We report a confocal interferometric mid-infrared photothermal (MIP) microscope for ultra-sensitive and spatially resolved chemical imaging of individual viruses. The interferometric scattering principle is applied to detect the very weak photothermal signal induced by infrared absorption of chemical bonds. Spectroscopic MIP detection of single vesicular stomatitis viruses (VSVs) and poxviruses is demonstrated. The single virus spectra show high consistency within the same virus type. The dominant spectral peaks are contributed by the amide I and amide II vibrations attributed to the viral proteins. The ratio of these two peaks is significantly different between VSVs and poxviruses, highlighting the potential of using interferometric MIP microscopy for label-free differentiation of viral particles. This all-optical chemical imaging method opens a new way for spectroscopic detection of biological nanoparticles in a label-free manner and may facilitate in predicting and controlling the outbreaks of emerging virus strains.


Assuntos
Microscopia , Vibração , Vírus de DNA , Interferometria , Análise Espectral
7.
Sensors (Basel) ; 21(8)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918613

RESUMO

Extracellular vesicles (EVs) have attracted significant attention as impactful diagnostic biomarkers, since their properties are closely related to specific clinical conditions. However, designing experiments that involve EVs phenotyping is usually highly challenging and time-consuming, due to laborious optimization steps that require very long or even overnight incubation durations. In this work, we demonstrate label-free, real-time detection, and phenotyping of extracellular vesicles binding to a multiplexed surface. With the ability for label-free kinetic binding measurements using the Interferometric Reflectance Imaging Sensor (IRIS) in a microfluidic chamber, we successfully optimize the capture reaction by tuning various assay conditions (incubation time, flow conditions, surface probe density, and specificity). A single (less than 1 h) experiment allows for characterization of binding affinities of the EVs to multiplexed probes. We demonstrate kinetic characterization of 18 different probe conditions, namely three different antibodies, each spotted at six different concentrations, simultaneously. The affinity characterization is then analyzed through a model that considers the complexity of multivalent binding of large structures to a carpet of probes and therefore introduces a combination of fast and slow association and dissociation parameters. Additionally, our results confirm higher affinity of EVs to aCD81 with respect to aCD9 and aCD63. Single-vesicle imaging measurements corroborate our findings, as well as confirming the EVs nature of the captured particles through fluorescence staining of the EVs membrane and cargo.


Assuntos
Vesículas Extracelulares , Anticorpos , Interferometria , Cinética , Coloração e Rotulagem
8.
Opt Lett ; 45(23): 6546-6549, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33258864

RESUMO

Single particle interferometric reflectance (SPIR) microscopy has been studied as a powerful imaging platform for label-free and highly sensitive biological nanoparticle detection and characterization. SPIR's interferometric nature yields a unique 3D defocus intensity profile of the nanoparticles over a large field of view. Here, we utilize this defocus information to recover high signal-to-noise ratio nanoparticle images with a computationally and memory efficient reconstruction framework. Our direct inversion approach recovers this image from a 3D defocus intensity stack using the vectorial-optics-based forward model developed for sub-diffraction-limited dielectric nanoparticles captured on a layered substrate. We demonstrate proof-of-concept experiments on silica beads with a 50 nm nominal diameter.

9.
Anal Bioanal Chem ; 412(14): 3477-3487, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31901959

RESUMO

Surface chemistry is a crucial aspect for microarray modality biosensor development. The immobilization capability of the functionalized surface is indeed a limiting factor for the final yield of the binding reaction. In this work, we were able to simultaneously compare the functionality of protein ligands that were locally immobilized on different polymers, while on the same solid support, therefore demonstrating a new way of multiplexing. Our goal was to investigate, in a single experiment, both the immobilization efficiency of a group of reactive polymers and the resulting affinity of the tethered molecules. This idea was demonstrated by spotting many reactive polymers on a Si/SiO2 chip and depositing the molecular probes on the spots immediately after. As a proof of concept, we focused on which polymers would better immobilize a model protein (α-Lactalbumin) and a peptide (LAC-1). We successfully showed that this protocol is applicable to proteins and peptides with a good efficiency. By means of real-time binding measurements performed with the interferometric reflectance imaging sensor (IRIS), local functionalization proved to be comparable to the classical flat coating solution. The final outcome highlights the multiplexing power of this method: first, it allows to characterize dozens of polymers at once. Secondly, it removes the limitation, related to coated surfaces, that only molecules with the same functional groups can be tethered to the same solid support. By applying this protocol, many types of molecules can be studied simultaneously and immobilization for each probe can be individually optimized.


Assuntos
Proteínas Imobilizadas/química , Polímeros/química , Dióxido de Silício/química , Técnicas Biossensoriais , Interferometria , Lactalbumina/química , Ligantes , Peptídeos/química , Análise Serial de Proteínas , Silício/química , Propriedades de Superfície
10.
Colorectal Dis ; 22(3): 279-288, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31566843

RESUMO

AIM: The aim was to compare the pathological complete response (pCR) rate at 8 compared to 12 weeks' interval between completion of neoadjuvant chemoradiotherapy (CRT) and surgery in patients with locally advanced rectal cancer. METHOD: This was a randomized trial which included a total of 330 patients from two institutions. Patients with locally advanced (T3-4N0M0, TxN+M0) rectal cancer were randomized into 8- and 12-week interval groups. All the patients received long-course CRT (45 Gy in 1.8 Gy fractions and concomitant oral capecitabine or 5-fluorouracil infusion). Surgery was performed at either 8 or 12 weeks after CRT. The primary end-point was pCR. Secondary end-points were sphincter preservation, postoperative morbidity and mortality. RESULTS: Two-hundred and fifty-two patients (n = 125 in the 8-week group, n = 127 in the 12-week group) were included. Demographic and clinical characteristics were similar between groups. The overall pCR rate was 17.9% (n = 45): 12% (n = 15) in the 8-week group and 23.6% (n = 30) in the 12-week group (P = 0.021). Sphincter-preserving surgery was performed in 107 (85.6%) patients which was significantly higher than the 94 (74%) patients in the 12-week group (P = 0.016). Postoperative mortality was seen in three (1.2%) patients overall and was not different between groups (1.6% in 8 weeks vs 0.8% in 12 weeks, P = 0.494). Groups were similar in anastomotic leak (10.8% in 8 weeks vs 4.5% in 12 weeks, P = 0.088) and morbidity (30.4% in 8 weeks and 20.1% in 12 weeks, P = 0.083). CONCLUSION: Extending the interval between CRT and surgery from 8 to 12 weeks resulted in a 2-fold increase in pCR rate without any difference in mortality and morbidity.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Capecitabina , Quimiorradioterapia , Fluoruracila , Humanos , Estadiamento de Neoplasias , Neoplasias Retais/patologia , Neoplasias Retais/terapia , Reto/patologia , Resultado do Tratamento
11.
Sensors (Basel) ; 19(8)2019 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-31018573

RESUMO

We review some emerging trends in transduction, connectivity and data analytics for Point-of-Care Testing (POCT) of infectious and non-communicable diseases. The patient need for POCT is described along with developments in portable diagnostics, specifically in respect of Lab-on-chip and microfluidic systems. We describe some novel electrochemical and photonic systems and the use of mobile phones in terms of hardware components and device connectivity for POCT. Developments in data analytics that are applicable for POCT are described with an overview of data structures and recent AI/Machine learning trends. The most important methodologies of machine learning, including deep learning methods, are summarised. The potential value of trends within POCT systems for clinical diagnostics within Lower Middle Income Countries (LMICs) and the Least Developed Countries (LDCs) are highlighted.

12.
Artigo em Inglês | MEDLINE | ID: mdl-28989270

RESUMO

Single-molecule and single-nanoparticle biosensors are a growing frontier in diagnostics. Digital biosensors are those which enumerate all specifically immobilized biomolecules or biological nanoparticles, and thereby achieve limits of detection usually beyond the reach of ensemble measurements. Here we review modern optical techniques for single nanoparticle detection and describe the single-particle interferometric reflectance imaging sensor (SP-IRIS). We present challenges associated with reliably detecting faint nanoparticles with SP-IRIS, and describe image acquisition processes and software modifications to address them. Specifically, we describe a image acquisition processing method for the discrimination and accurate counting of nanoparticles that greatly reduces both the number of false positives and false negatives. These engineering improvements are critical steps in the translation of SP-IRIS towards applications in medical diagnostics.

13.
Appl Opt ; 56(15): 4238-4242, 2017 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-29047844

RESUMO

Interference-enhanced wide-field nanoparticle imaging is a highly sensitive technique that has found numerous applications in labeled and label-free subdiffraction-limited pathogen detection. It also provides unique opportunities for nanoparticle classification upon detection. More specifically, the nanoparticle defocus images result in a particle-specific response that can be of great utility for nanoparticle classification, particularly based on type and size. In this work, we combine a model-based supervised learning algorithm with a wide-field common-path interferometric microscopy method to achieve accurate nanoparticle classification. We verify our classification schemes experimentally by blindly detecting gold and polystyrene nanospheres, and then classifying them in terms of type and size.

14.
Opt Express ; 24(6): 6094-114, 2016 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-27136804

RESUMO

Interferometric imaging schemes have gained significant interest due to their superior sensitivity over imaging techniques that are solely based on scattered signal. In this study, we outline the theoretical foundations of imaging and characterization of single nanoparticles in an interferometric microscopy scheme, examine key parameters that influence the signal, and benchmark the model against experimental findings.

15.
Sensors (Basel) ; 16(2): 198, 2016 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-26861324

RESUMO

Extracellular neural recording, with multi-electrode arrays (MEAs), is a powerful method used to study neural function at the network level. However, in a high density array, it can be costly and time consuming to integrate the active circuit with the expensive electrodes. In this paper, we present a 4 mm × 4 mm neural recording integrated circuit (IC) chip, utilizing IBM C4 bumps as recording electrodes, which enable a seamless active chip and electrode integration. The IC chip was designed and fabricated in a 0.13 µm BiCMOS process for both in vitro and in vivo applications. It has an input-referred noise of 4.6 µV rms for the bandwidth of 10 Hz to 10 kHz and a power dissipation of 11.25 mW at 2.5 V, or 43.9 µW per input channel. This prototype is scalable for implementing larger number and higher density electrode arrays. To validate the functionality of the chip, electrical testing results and acute in vivo recordings from a rat barrel cortex are presented.


Assuntos
Córtex Cerebelar/fisiologia , Microeletrodos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Potenciais de Ação , Amplificadores Eletrônicos , Animais , Ratos
16.
Anal Chem ; 87(20): 10505-12, 2015 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-26378807

RESUMO

Here, we describe the use of DNA-conjugated antibodies for rapid and sensitive detection of whole viruses using a single-particle interferometric reflectance imaging sensor (SP-IRIS), a simple, label-free biosensor capable of imaging individual nanoparticles. First, we characterize the elevation of the antibodies conjugated to a DNA sequence on a three-dimensional (3-D) polymeric surface using a fluorescence axial localization technique, spectral self-interference fluorescence microscopy (SSFM). Our results indicate that using DNA linkers results in significant elevation of the antibodies on the 3-D polymeric surface. We subsequently show the specific detection of pseudotyped vesicular stomatitis virus (VSV) as a model virus on SP-IRIS platform. We demonstrate that DNA-conjugated antibodies improve the capture efficiency by achieving the maximal virus capture for an antibody density as low as 0.72 ng/mm(2), whereas for unmodified antibody, the optimal virus capture requires six times greater antibody density on the sensor surface. We also show that using DNA conjugated anti-EBOV GP (Ebola virus glycoprotein) improves the sensitivity of EBOV-GP carrying VSV detection compared to directly immobilized antibodies. Furthermore, utilizing a DNA surface for conversion to an antibody array offers an easier manufacturing process by replacing the antibody printing step with DNA printing. The DNA-directed immobilization technique also has the added advantages of programmable sensor surface generation based on the need and resistance to high temperatures required for microfluidic device fabrication. These capabilities improve the existing SP-IRIS technology, resulting in a more robust and versatile platform, ideal for point-of-care diagnostics applications.


Assuntos
Anticorpos Imobilizados/química , Técnicas Biossensoriais , Sondas de DNA/química , DNA/química , Vesiculovirus/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Microscopia de Fluorescência/instrumentação , Vesiculovirus/patogenicidade
17.
Opt Express ; 23(11): 15072-87, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26072864

RESUMO

Resolution improvement through signal processing techniques for integrated circuit imaging is becoming more crucial as the rapid decrease in integrated circuit dimensions continues. Although there is a significant effort to push the limits of optical resolution for backside fault analysis through the use of solid immersion lenses, higher order laser beams, and beam apodization, signal processing techniques are required for additional improvement. In this work, we propose a sparse image reconstruction framework which couples overcomplete dictionary-based representation with a physics-based forward model to improve resolution and localization accuracy in high numerical aperture confocal microscopy systems for backside optical integrated circuit analysis. The effectiveness of the framework is demonstrated on experimental data.

18.
Sensors (Basel) ; 15(7): 17649-65, 2015 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-26205273

RESUMO

Over the last decade, the growing need in disease diagnostics has stimulated rapid development of new technologies with unprecedented capabilities. Recent emerging infectious diseases and epidemics have revealed the shortcomings of existing diagnostics tools, and the necessity for further improvements. Optical biosensors can lay the foundations for future generation diagnostics by providing means to detect biomarkers in a highly sensitive, specific, quantitative and multiplexed fashion. Here, we review an optical sensing technology, Interferometric Reflectance Imaging Sensor (IRIS), and the relevant features of this multifunctional platform for quantitative, label-free and dynamic detection. We discuss two distinct modalities for IRIS: (i) low-magnification (ensemble biomolecular mass measurements) and (ii) high-magnification (digital detection of individual nanoparticles) along with their applications, including label-free detection of multiplexed protein chips, measurement of single nucleotide polymorphism, quantification of transcription factor DNA binding, and high sensitivity digital sensing and characterization of nanoparticles and viruses.


Assuntos
Técnicas Biossensoriais/instrumentação , Diagnóstico por Imagem/instrumentação , Interferometria/instrumentação , Processamento de Sinais Assistido por Computador , Humanos
19.
Opt Express ; 22(6): 7320-9, 2014 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-24664079

RESUMO

We theoretically and experimentally investigate the effect of imperfect vector symmetry on radially polarized beams focused by an aplanatic solid immersion lens at a numerical aperture of 3.3. We experimentally achieve circularly symmetric focused spot with a full-width-half-maximum of ~λ0/5.7 at λ0 = 1,310 nm, free-space wavelength. The tight spatial confinement and overall circular symmetry of the focused radially polarized beam are found to be sensitive to perturbations of its cylindrical polarization symmetry. The addition of a liquid crystal based variable retarder to the optical path can effectively ensure the vector symmetry and achieve circularly symmetric focused spots at such high numerical aperture conditions.

20.
Opt Express ; 22(7): 7422-33, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24718117

RESUMO

The collection of light at very high numerical aperture allows detection of evanescent waves above the critical angle of total internal reflection in solid immersion lens microscopy. We investigate the effect of such evanescent modes, so-called forbidden light, on the far-field imaging properties of an aplanatic solid immersion microscope by developing a dyadic Green's function formalism in the context of subsurface semiconductor integrated circuit imaging. We demonstrate that the collection of forbidden light allows for sub-diffraction spatial resolution and substantial enhancement of photon collection efficiency albeit inducing wave-front discontinuities and aberrations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA