Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Phys J A Hadron Nucl ; 58(3): 47, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35313621

RESUMO

[This corrects the article DOI: 10.1140/epja/s10050-021-00614-5.].

2.
Phys Rev Lett ; 123(6): 061802, 2019 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-31491142

RESUMO

Using lattice simulations we demonstrate from first principles the existence of a nonperturbative mechanism for elementary particle mass generation in models with gauge fields, fermions, and scalars, if an exact invariance forbids power divergent fermion masses and fermionic chiral symmetries broken at UV scale are maximally restored. We show that in the Nambu-Goldstone phase a fermion mass term, unrelated to the Yukawa operator, is dynamically generated. In models with electroweak interactions weak boson masses are also generated, opening new scenarios for beyond the standard model physics.

4.
Phys Rev Lett ; 111(18): 181602, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24237506

RESUMO

We present a lattice QCD computation of η and η' masses and mixing angles, for the first time controlling continuum and quark mass extrapolations. The results for M(η) = 551(8)(stat) (6)(yst) MeV and M(η') = 1006(54)(stat)(38)(syst)(+61)(ex) MeV are in excellent agreement with experiment. Our data show that the mixing in the quark flavor basis can be described by a single mixing angle of Ø = 46(1)(stat)(3)(syst)° indicating that the η' is mainly a flavor singlet state.

5.
Nuklearmedizin ; 50(6): 240-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21876870

RESUMO

AIM: The hard beta and gamma radiation of 124I can cause high doses to PET/CT workers. In this study we tried to quantify this occupational exposure and to optimize radioprotection. METHODS: Thin MCP-Ns thermoluminescent dosimeters suitable for measuring beta and gamma radiation were used for extremity dosimetry, active personal dosimeters for whole-body dosimetry. Extremity doses were determined during dispensing of 124I and oral administration of the activity to the patient, the body dose during all phases of the PET/CT procedure. In addition, dose rates of vials and syringes as used in clinical practice were measured. The procedure for dispensing 124I was optimized using newly developed shielding. RESULTS: Skin dose rates up to 100 mSv/min were measured when in contact with the manufacturer's vial containing 370 MBq of 124I. For an unshielded 5 ml syringe the positron skin dose was about seven times the gamma dose. Before optimization of the preparation of 124I, using an already reasonably safe technique, the highest mean skin dose caused by handling 370 MBq was 1.9 mSv (max. 4.4 mSv). After optimization the skin dose was below 0.2 mSv. CONCLUSION: The highly energetic positrons emitted by 124I can cause high skin doses if radioprotection is poor. Under optimized conditions occupational doses are acceptable. Education of workers is of paramount importance.


Assuntos
Partículas beta , Carga Corporal (Radioterapia) , Raios gama , Radioisótopos do Iodo/análise , Exposição Ocupacional/análise , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Contagem Corporal Total , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA