Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Microbiol Resour Announc ; 11(7): e0047622, 2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35735981

RESUMO

The 5.2-Mb circular genome of Klebsiella quasipneumoniae subsp. similipneumoniae strain IF3SW-P1, isolated from the International Space Station, was sequenced using Oxford Nanopore Technologies. The genome lacks a megaplasmid typical of hypervirulent and multidrug-resistant Klebsiella strains but does contain a chromosomally encoded OqxAB efflux pump associated with carbapenem resistance.

2.
J Biomol Tech ; 32(3): 199-205, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-35027877

RESUMO

Loop-mediated isothermal amplification (LAMP) is a power tool for the amplification of specific RNA and DNA targets. Much like PCR, LAMP requires primers that surround a target amplification region and generates exponential product through a unique highly specific daisy-chain single-temperature amplification reaction. However, until recently, attempts to amplify targets of greater than 200 base pairs (bp) have been mostly unsuccessful and limited to short amplicon targets of less than 150 bp. Although short amplicons have the benefit of a rapid detection (<40 min), they do not allow for the prediction of RNA integrity based on RNA length and possible intactness. In this study, 8 primer sets were developed using 2 LAMP primer-specific software packages against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid gene with insert lengths ranging from 262 to 945 bp in order to amplify and infer the integrity of viral RNA. Because these amplification lengths are greater than the current methods that use an insert length of 130 or less, they require a longer incubation, modified primer and temperature strategies, and the addition of specific adjuncts to prevent nonspecific amplification. This proof of concept study resulted in successful reverse transcription LAMP reactions for amplicon targets of 262, 687, 693, and 945 bp using a clinical nasopharyngeal NP sample, purified SARS-CoV-2 RNA, and crude lysate containing inactivated virus.


Assuntos
COVID-19 , Transcrição Reversa , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/genética , SARS-CoV-2 , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA