Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Occup Med (Lond) ; 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38078542

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) caused a high burden of sick leave worldwide. Long-term sick leave for COVID-19 may be longer than for other influenza-like syndromes. The real impact of long COVID on absenteeism remains uncertain. AIMS: To investigate the burden of sick leave, especially >12 weeks, in Belgian workers with a positive polymerase chain reaction (PCR) test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from July 2020 to September 2021 and to compare these figures with sick leave for other infectious diseases. METHODS: We coupled a database of SARS-CoV-2-positive workers and workers who were absent for other infections with objective absence data. Predictors of prolonged sickness were evaluated by negative binomial regression, Cox proportional hazards regression and ordinal logistic regression. RESULTS: The study population involved 2569 workers who tested positive for SARS-CoV-2 and 392 workers who were absent for other infectious diseases. In total, 16% (95% CI 14-17%) of workers with a positive SARS-CoV-2 test had no sick leave registered. Fourteen out of 1000 (95% CI 9-20‰) workers with absenteeism for COVID-19 experienced sick leave >12 weeks as compared to 43 out of 1000 workers (95% CI 3-69‰) with absenteeism due to other infections. When including PCR-positive workers without sick leave, the prevalence of long-term sick leave decreased to 12 per 1000 (95% CI8-17‰). Long-term sick leave was associated with older age, high previous sick leave and low educational level. CONCLUSIONS: The prevalence of long-term sick leave was lower than estimated in earlier investigations regardless of worrying reports about post-COVID-19 syndrome.

2.
Opt Express ; 29(21): 34531-34551, 2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34809241

RESUMO

Strain engineering in semiconductor transistor devices has become vital in the semiconductor industry due to the ever-increasing need for performance enhancement at the nanoscale. Raman spectroscopy is a non-invasive measurement technique with high sensitivity to mechanical stress that does not require any special sample preparation procedures in comparison to characterization involving transmission electron microscopy (TEM), making it suitable for inline strain measurement in the semiconductor industry. Indeed, at present, strain measurements using Raman spectroscopy are already routinely carried out in semiconductor devices as it is cost effective, fast and non-destructive. In this paper we explore the usage of linearized radially polarized light as an excitation source, which does provide significantly enhanced accuracy and precision as compared to linearly polarized light for this application. Numerical simulations are done to quantitatively evaluate the electric field intensities that contribute to this enhanced sensitivity. We benchmark the experimental results against TEM diffraction-based techniques like nano-beam diffraction and Bessel diffraction. Differences between both approaches are assigned to strain relaxation due to sample thinning required in TEM setups, demonstrating the benefit of Raman for nondestructive inline testing.

3.
Phys Rev Lett ; 127(12): 127202, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34597094

RESUMO

In oxide heterostructures, different materials are integrated into a single artificial crystal, resulting in a breaking of inversion symmetry across the heterointerfaces. A notable example is the interface between polar and nonpolar materials, where valence discontinuities lead to otherwise inaccessible charge and spin states. This approach paved the way for the discovery of numerous unconventional properties absent in the bulk constituents. However, control of the geometric structure of the electronic wave functions in correlated oxides remains an open challenge. Here, we create heterostructures consisting of ultrathin SrRuO_{3}, an itinerant ferromagnet hosting momentum-space sources of Berry curvature, and LaAlO_{3}, a polar wide-band-gap insulator. Transmission electron microscopy reveals an atomically sharp LaO/RuO_{2}/SrO interface configuration, leading to excess charge being pinned near the LaAlO_{3}/SrRuO_{3} interface. We demonstrate through magneto-optical characterization, theoretical calculations and transport measurements that the real-space charge reconstruction drives a reorganization of the topological charges in the band structure, thereby modifying the momentum-space Berry curvature in SrRuO_{3}. Our results illustrate how the topological and magnetic features of oxides can be manipulated by engineering charge discontinuities at oxide interfaces.

4.
Stat Med ; 38(30): 5641-5656, 2019 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-31659790

RESUMO

In the analysis of composite endpoints in a clinical trial, time to first event analysis techniques such as the logrank test and Cox proportional hazard test do not take into account the multiplicity, importance, and the severity of events in the composite endpoint. Several generalized pairwise comparison analysis methods have been described recently that do allow to take these aspects into account. These methods have the additional benefit that all types of outcomes can be included, such as longitudinal quantitative outcomes, to evaluate the full treatment effect. Four of the generalized pairwise comparison methods, ie, the Finkelstein-Schoenfeld, the Buyse, unmatched Pocock, and adapted O'Brien test, are summarized. They are compared to each other and to the logrank test by means of simulations while specifically evaluating the effect of correlation between components of the composite endpoint on the power to detect a treatment difference. These simulations show that prioritized generalized pairwise comparison methods perform very similarly, are sensitive to the priority rank of the components in the composite endpoint, and do not measure the true treatment effect from the second priority-ranked component onward. The nonprioritized pairwise comparison test does not suffer from these limitations and correlation affects only its variance.


Assuntos
Determinação de Ponto Final/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Bioestatística , Simulação por Computador , Interpretação Estatística de Dados , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Modelos Estatísticos , Estatísticas não Paramétricas , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
5.
Nat Mater ; 15(4): 425-31, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26950593

RESUMO

Controlled in-plane rotation of the magnetic easy axis in manganite heterostructures by tailoring the interface oxygen network could allow the development of correlated oxide-based magnetic tunnelling junctions with non-collinear magnetization, with possible practical applications as miniaturized high-switching-speed magnetic random access memory (MRAM) devices. Here, we demonstrate how to manipulate magnetic and electronic anisotropic properties in manganite heterostructures by engineering the oxygen network on the unit-cell level. The strong oxygen octahedral coupling is found to transfer the octahedral rotation, present in the NdGaO3 (NGO) substrate, to the La2/3Sr1/3MnO3 (LSMO) film in the interface region. This causes an unexpected realignment of the magnetic easy axis along the short axis of the LSMO unit cell as well as the presence of a giant anisotropic transport in these ultrathin LSMO films. As a result we possess control of the lateral magnetic and electronic anisotropies by atomic-scale design of the oxygen octahedral rotation.


Assuntos
Armazenamento e Recuperação da Informação , Compostos de Manganês/química , Oxigênio/química , Anisotropia , Rotação
6.
Phys Rev Lett ; 119(25): 256403, 2017 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-29303305

RESUMO

We investigate the thickness-dependent electronic properties of ultrathin SrIrO_{3} and discover a transition from a semimetallic to a correlated insulating state below 4 unit cells. Low-temperature magnetoconductance measurements show that spin fluctuations in the semimetallic state are significantly enhanced while approaching the transition point. The electronic properties are further studied by scanning tunneling spectroscopy, showing that 4 unit cell SrIrO_{3} is on the verge of a gap opening. Our density functional theory calculations reproduce the critical thickness of the transition and show that the opening of a gap in ultrathin SrIrO_{3} requires antiferromagnetic order.

7.
Nat Mater ; 14(8): 801-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26030303

RESUMO

Two-dimensional electron gases (2DEGs) formed at the interface of insulating complex oxides promise the development of all-oxide electronic devices. These 2DEGs involve many-body interactions that give rise to a variety of physical phenomena such as superconductivity, magnetism, tunable metal-insulator transitions and phase separation. Increasing the mobility of the 2DEG, however, remains a major challenge. Here, we show that the electron mobility is enhanced by more than two orders of magnitude by inserting a single-unit-cell insulating layer of polar La(1-x)Sr(x)MnO3 (x = 0, 1/8, and 1/3) at the interface between disordered LaAlO3 and crystalline SrTiO3 produced at room temperature. Resonant X-ray spectroscopy and transmission electron microscopy show that the manganite layer undergoes unambiguous electronic reconstruction, leading to modulation doping of such atomically engineered complex oxide heterointerfaces. At low temperatures, the modulation-doped 2DEG exhibits Shubnikov-de Haas oscillations and fingerprints of the quantum Hall effect, demonstrating unprecedented high mobility and low electron density.

8.
Nature ; 467(7313): 301-4, 2010 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-20844532

RESUMO

Vortex beams (also known as beams with a phase singularity) consist of spiralling wavefronts that give rise to angular momentum around the propagation direction. Vortex photon beams are widely used in applications such as optical tweezers to manipulate micrometre-sized particles and in micro-motors to provide angular momentum, improving channel capacity in optical and radio-wave information transfer, astrophysics and so on. Very recently, an experimental realization of vortex beams formed of electrons was demonstrated. Here we describe the creation of vortex electron beams, making use of a versatile holographic reconstruction technique in a transmission electron microscope. This technique is a reproducible method of creating vortex electron beams in a conventional electron microscope. We demonstrate how they may be used in electron energy-loss spectroscopy to detect the magnetic state of materials and describe their properties. Our results show that electron vortex beams hold promise for new applications, in particular for analysing and manipulating nanomaterials, and can be easily produced.

9.
Phys Rev Lett ; 115(17): 176101, 2015 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-26551126

RESUMO

Atomic resolution transmission electron microscopy records the spatially resolved scattered electron density to infer positions, density, and species of atoms. These data are indispensable for studying the relation between structure and properties in solids. Here, we show how this signal can be augmented by the lateral probability current of the scattered electrons in the object plane at similar resolutions and fields of view. The currents are reconstructed from a series of three atomic resolution TEM images recorded under a slight difference of perpendicular line foci. The technique does not rely on the coherence of the electron beam and can be used to reveal electric, magnetic, and strain fields with incoherent electron beams as well as correlations in inelastic transitions, such as electron magnetic chiral dichroism.

10.
Phys Rev Lett ; 111(6): 064801, 2013 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-23971578

RESUMO

A model for a new electron-vortex beam production method is proposed and experimentally demonstrated. The technique calls on the controlled manipulation of the degrees of freedom of the lens aberrations to achieve a helical phase front. These degrees of freedom are accessible by using the corrector lenses of a transmission electron microscope. The vortex beam is produced through a particular alignment of these lenses into a specifically designed astigmatic state and applying an annular aperture in the condenser plane. Experimental results are found to be in good agreement with simulations.

11.
Phys Rev Lett ; 111(20): 208302, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24289712

RESUMO

The degradation of colors in historical paintings affects our cultural heritage in both museums and archeological sites. Despite intensive experimental studies, the origin of darkening of one of the most ancient pigments known to humankind, vermilion (α-HgS), remains unexplained. Here, by combining many-body theoretical spectroscopy and high-resolution microscopic x-ray diffraction, we clarify the composition of the damaged paint work and demonstrate possible physicochemical processes, induced by illumination and exposure to humidity and air, that cause photoactivation of the original pigment and the degradation of the secondary minerals. The results suggest a new path for the darkening process which was never considered by previous studies and prompt a critical examination of their findings.

12.
Phys Rev Lett ; 109(8): 084801, 2012 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-23002749

RESUMO

A mode converter for electron vortex beams is described. Numerical simulations, confirmed by experiment, show that the converter transforms a vortex beam with a topological charge m=±1 into beams closely resembling Hermite-Gaussian HG(10) and HG(01) modes. The converter can be used as a mode discriminator or filter for electron vortex beams. Combining the converter with a phase plate turns a plane wave into modes with topological charge m=±1. This combination serves as a generator of electron vortex beams of high brilliance.

13.
Ultramicroscopy ; 240: 113568, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35716488

RESUMO

In this second part of a series we attempt to construct an empirical model that can mimick all experimental observations made regarding the role of an alternative interleaved scan pattern in STEM imaging on the beam damage in a specific zeolite sample. We make use of a 2D diffusion model that describes the dissipation of the deposited beam energy in the sequence of probe positions that are visited during the scan pattern. The diffusion process allows for the concept of trying to 'outrun' the beam damage by carefully tuning the dwell time and distance between consecutively visited probe positions. We add a non linear function to include a threshold effect and evaluate the accumulated damage in each part of the image as a function of scan pattern details. Together, these ingredients are able to describe qualitatively all aspects of the experimental data and provide us with a model that could guide a further optimisation towards even lower beam damage without lowering the applied electron dose. We deliberately remain vague on what is diffusing here which avoids introducing too many sample specific details. This provides hope that the model can be applied also in sample classes that were not yet studied in such great detail by adjusting higher level parameters: a sample dependent diffusion constant and damage threshold.

14.
Ultramicroscopy ; 232: 113398, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34655928

RESUMO

The highly energetic electrons in a transmission electron microscope (TEM) can alter or even completely destroy the structure of samples before sufficient information can be obtained. This is especially problematic in the case of zeolites, organic and biological materials. As this effect depends on both the electron beam and the sample and can involve multiple damage pathways, its study remained difficult and is plagued with irreproducibility issues, circumstantial evidence, rumors, and a general lack of solid data. Here we take on the experimental challenge to investigate the role of the STEM scan pattern on the damage behavior of a commercially available zeolite sample with the clear aim to make our observations as reproducible as possible. We make use of a freely programmable scan engine that gives full control over the tempospatial distribution of the electron probe on the sample and we use its flexibility to obtain multiple repeated experiments under identical conditions comparing the difference in beam damage between a conventional raster scan pattern and a newly proposed interleaved scan pattern that provides exactly the same dose and dose rate and visits exactly the same scan points. We observe a significant difference in beam damage for both patterns with up to 11 % reduction in damage (measured from mass loss). These observations demonstrate without doubt that electron dose, dose rate and acceleration voltage are not the only parameters affecting beam damage in (S)TEM experiments and invite the community to rethink beam damage as an unavoidable consequence of applied electron dose.


Assuntos
Elétrons
15.
Science ; 375(6581): 653-657, 2022 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-35143321

RESUMO

Piezoelectrics are materials that linearly deform in response to an applied electric field. As a fundamental prerequisite, piezoelectric materials must have a noncentrosymmetric crystal structure. For more than a century, this has remained a major obstacle for finding piezoelectric materials. We circumvented this limitation by breaking the crystallographic symmetry and inducing large and sustainable piezoelectric effects in centrosymmetric materials by the electric field-induced rearrangement of oxygen vacancies. Our results show the generation of extraordinarily large piezoelectric responses [with piezoelectric strain coefficients (d33) of ~200,000 picometers per volt at millihertz frequencies] in cubic fluorite gadolinium-doped CeO2-x films, which are two orders of magnitude larger than the responses observed in the presently best-known lead-based piezoelectric relaxor-ferroelectric oxide at kilohertz frequencies. These findings provide opportunities to design piezoelectric materials from environmentally friendly centrosymmetric ones.

16.
Ultramicroscopy ; 233: 113423, 2021 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-34837737

RESUMO

Four dimensional scanning transmission electron microscopy (4D STEM) records the scattering of electrons in a material in great detail. The benefits offered by 4D STEM are substantial, with the wealth of data it provides facilitating for instance high precision, high electron dose efficiency phase imaging via centre of mass or ptychography based analysis. However the requirement for a 2D image of the scattering to be recorded at each probe position has long placed a severe bottleneck on the speed at which 4D STEM can be performed. Recent advances in camera technology have greatly reduced this bottleneck, with the detection efficiency of direct electron detectors being especially well suited to the technique. However even the fastest frame driven pixelated detectors still significantly limit the scan speed which can be used in 4D STEM, making the resulting data susceptible to drift and hampering its use for low dose beam sensitive applications. Here we report the development of the use of an event driven Timepix3 direct electron camera that allows us to overcome this bottleneck and achieve 4D STEM dwell times down to 100 ns; orders of magnitude faster than what has been possible with frame based readout. We characterize the detector for different acceleration voltages and show that the method is especially well suited for low dose imaging and promises rich datasets without compromising dwell time when compared to conventional STEM imaging.

17.
Sci Rep ; 11(1): 10726, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34021190

RESUMO

The Anomalous Hall Effect (AHE) is an important quantity in determining the properties and understanding the behaviour of the two-dimensional electron system forming at the interface of SrTiO3-based oxide heterostructures. The occurrence of AHE is often interpreted as a signature of ferromagnetism, but it is becoming more and more clear that also paramagnets may contribute to AHE. We studied the influence of magnetic ions by measuring intermixed LaAlO3/GdTiO3/SrTiO3 at temperatures below 10 K. We find that, as function of gate voltage, the system undergoes a Lifshitz transition while at the same time an onset of AHE is observed. However, we do not observe clear signs of ferromagnetism. We argue the AHE to be due to the change in Rashba spin-orbit coupling at the Lifshitz transition and conclude that also paramagnetic moments which are easily polarizable at low temperatures and high magnetic fields lead to the presence of AHE, which needs to be taken into account when extracting carrier densities and mobilities.

18.
Eur J Clin Microbiol Infect Dis ; 29(11): 1427-34, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20830499

RESUMO

In order to study the hepatitis C virus (HCV) epidemiology in Flanders, Belgium, the HCV genotype of 2,301 patients diagnosed with HCV between 2001 and 2009 was determined. HCV genotyping was conducted using the Versant LiPA 1.0 or Versant LiPA 2.0 assay. To explore the transmission history of a remarkable cluster of the rarely found HCV genotype 5a, face-to-face interviews based on detailed questionnaires and maximum likelihood phylogenetic analysis were performed. HCV genotype 1 was the most prevalent genotype in all provinces, followed by HCV genotype 3 in East Flanders, Antwerp, Flemish Brabant and Limburg. In Brussels, HCV genotype 4 was the second most prevalent genotype. This observation is due to the immigration of patients from the Middle East and Africa. Remarkably, a cluster of HCV genotype 5a was found in West Flanders, where it represents the second most prevalent genotype, accounting for 26.2% of HCV infections. We could not identify one major transmission source explaining the whole HCV genotype 5a epidemic. Instead, several smaller possible transmission chains were identified and confirmed phylogenetically. Overall, the HCV genotype 5a epidemic in West Flanders seems to be mainly associated with blood transfusion and unsafe medical practices.


Assuntos
Hepacivirus/genética , Hepatite C Crônica/epidemiologia , Hepatite C Crônica/virologia , Bélgica/epidemiologia , Análise por Conglomerados , Feminino , Genótipo , Hepacivirus/classificação , Hepacivirus/isolamento & purificação , Humanos , Masculino , Filogenia , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sorotipagem , Inquéritos e Questionários
19.
Ultramicroscopy ; 215: 113021, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32485392

RESUMO

STEM imaging is typically performed by raster scanning a focused electron probe over a sample. Here we investigate and compare three different scan patterns, making use of a programmable scan engine that allows to arbitrarily set the sequence of probe positions that are consecutively visited on the sample. We compare the typical raster scan with a so-called 'snake' pattern where the scan direction is reversed after each row and a novel Hilbert scan pattern that changes scan direction rapidly and provides an homogeneous treatment of both scan directions. We experimentally evaluate the imaging performance on a single crystal test sample by varying dwell time and evaluating behaviour with respect to sample drift. We demonstrate the ability of the Hilbert scan pattern to more faithfully represent the high frequency content of the image in the presence of sample drift. It is also shown that Hilbert scanning provides reduced bias when measuring lattice parameters from the obtained scanned images while maintaining similar precision in both scan directions which is especially important when e.g. performing strain analysis. Compared to raster scanning with flyback correction, both snake and Hilbert scanning benefit from dose reduction as only small probe movement steps occur.

20.
Ultramicroscopy ; 219: 113099, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32896758

RESUMO

Lattice strain measurement of nanoscale semiconductor devices is crucial for the semiconductor industry as strain substantially improves the electrical performance of transistors. High resolution scanning transmission electron microscopy (HR-STEM) imaging is an excellent tool that provides spatial resolution at the atomic scale and strain information by applying Geometric Phase Analysis or image fitting procedures. However, HR-STEM images regularly suffer from scanning distortions and sample drift during image acquisition. In this paper, we propose a new scanning strategy that drastically reduces artefacts due to drift and scanning distortion, along with extending the field of view. It consists of the acquisition of a series of independent small subimages containing an atomic resolution image of the local lattice. All subimages are then analysed individually for strain by fitting a nonlinear model to the lattice images. The method allows flexible tuning of spatial resolution and the field of view within the limits of the dynamic range of the scan engine while maintaining atomic resolution sampling within the subimages. The obtained experimental strain maps are quantitatively benchmarked against the Bessel diffraction technique. We demonstrate that the proposed scanning strategy approaches the performance of the diffraction technique while having the advantage that it does not require specialized diffraction cameras.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA