Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Endocrinol (Oxf) ; 101(2): 142-152, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38818709

RESUMO

OBJECTIVE: To report our experience with 18F-fluoro-ethyl-tyrosine (FET) positron emission tomography-computed tomography (PET-CT) co-registered with magnetic resonance imaging (MRI) (FET-PET/MRICR) in the care trajectory for persistent acromegaly. DESIGN: Prospective case series. PATIENTS: Ten patients with insufficiently controlled acromegaly referred to our team to evaluate surgical options. MEASUREMENTS: FET-PET/MRICR was used to support decision-making if MRI alone and multidisciplinary team evaluation did not provide sufficient clarity to proceed to surgery. RESULTS: FET-PET/MRICR showed suspicious (para)sellar tracer uptake in all patients. In five patients FET-PET/MRICR was fully concordant with conventional MRI, and in one patient partially concordant. FET-PET/MRICR identified suggestive new foci in four other patients. Surgical re-exploration was performed in nine patients (aimed at total resection (6), debulking (2), diagnosis (1)), and one patient underwent radiation therapy. In 7 of 9 (78%) operated patients FET-PET/MRICR findings were confirmed intraoperatively, and in six (67%) also histologically. IGF-1 decreased significantly in eight patients (89%). All patients showed clinical improvement. Complete biochemical remission was achieved in three patients (50% of procedures in which total resection was anticipated feasible). Biochemistry improved in five and was unchanged in one patient. No permanent complications occurred. At six months, optimal outcome (preoperative intended goal achieved without permanent complications) was achieved in six (67%) patients and an intermediate outcome (goal not achieved, but no complications) in the other three patients. CONCLUSIONS: In patients with persisting acromegaly without a clear surgical target on MRI, FET-PET/MRICR is a new tracer to provide additional information to aid decision-making by the multidisciplinary pituitary team.


Assuntos
Acromegalia , Imageamento por Ressonância Magnética , Tirosina , Humanos , Acromegalia/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Adulto , Estudos Prospectivos , Tirosina/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Fator de Crescimento Insulin-Like I/metabolismo
2.
Skeletal Radiol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967687

RESUMO

PURPOSE: Morphological magnetic resonance (MR) and computed tomography (CT) features are used in combination with histology for diagnosis and treatment selection of primary bone neoplasms. Isolated functional MRI parameters have shown potential in diagnosis. Our goal is to facilitate diagnosis of primary bone neoplasms of the skull base, mobile spine and sacrum, by a comprehensive approach, combining morphological and functional imaging parameters. MATERIALS AND METHODS: Pre-treatment MR of 80 patients with histologically proven diagnosis of a primary bone neoplasm of the skull base, mobile spine and sacrum were retrospectively analyzed for morphological and functional MRI parameters. Functional parameters were measured in 4 circular regions of interest per tumor placed on non-adjacent scan slices. Differences in values of functional parameters between different histologies were analyzed with Dunn's test. RESULTS: Chordomas were the predominant histology (60.0%). Most neoplasms (80.0%) originated in the midline and had geographical (78.2%) bone destruction. Amorphous-type calcification (pre-existing bone) was seen only in chordomas. Homogeneous contrast enhancement pattern was seen only in chondrosarcoma and plasmacytoma. Ktrans and Kep were significantly lower in both chordoma, and chondrosarcoma compared to giant cell tumor of the bone (p = 0.006 - 0.011), and plasmacytoma (p = 0.004 - 0.014). Highest diffusion-weighted MRI apparent diffusion coefficient (ADC) values corresponded to chondrosarcoma and were significantly higher to those of chordoma (p = 0.008). CONCLUSION: We identified the most discriminating morphological parameters and added functional MR parameters based on histopathological features that are useful in making a confident diagnosis of primary bone neoplasms in the skull base, mobile spine and sacrum.

3.
Radiology ; 302(3): 605-612, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34874202

RESUMO

Background Histopathologic studies reported that cochlear implantation, a well-established means to treat severe-to-profound sensorineural hearing loss, may induce inflammation, fibrosis, and new bone formation (NBF) with possible impact on loss of residual hearing and hearing outcome. Purpose To assess NBF in vivo after cochlear implantation with ultra-high-spatial-resolution (UHSR) CT and its implication on long-term residual hearing outcome. Materials and Methods In a secondary analysis of a prospective single-center cross-sectional study, conducted between December 2016 and January 2018, patients with at least 1 year of cochlear implantation experience underwent temporal bone UHSR CT and residual hearing assessment. Two observers evaluated the presence and location of NBF independently, and tetrachoric correlations were used to assess interobserver reliability. In addition, the scalar location of each electrode was assessed. After consensus agreement, participants were classified into two groups: those with NBF (n = 83) and those without NBF (n = 40). The association between NBF and clinical parameters, including electrode design, surgical approach, and long-term residual hearing loss, was tested using the χ2 and Student t tests. Results A total of 123 participants (mean age ± standard deviation, 63 years ± 13; 63 women) were enrolled. NBF was found in 83 of the 123 participants (68%) at 466 of 2706 electrode contacts (17%). Most NBFs (428 of 466, 92%) were found around the 10 most basal contacts, with an interobserver agreement of 86% (2297 of 2683 contacts). Associations between electrode types and surgical approaches were significant (58 of 79 participants with NBF and a precurved electrode vs 24 of 43 with NBF and a straight electrode, P = .04; 64 of 88 participants with NBF and a cochleostomy approach vs 18 of 34 with NBF and a round window approach, P = .03). NBF was least often seen in full scala tympani insertions, but there was no significant association between scalar position and NBF (P = .15). Long-term residual hearing loss was significantly larger in the group with NBF compared with the group without NBF (mean, 22.9 dB ± 14 vs 8.6 dB ± 18, respectively; P = .04). Conclusion In vivo detection of new bone formation (NBF) after cochlear implantation is possible by using ultra-high-spatial-resolution CT. Most cochlear implant recipients develop NBF, predominately located at the base of the cochlea. NBF adversely affects long-term residual hearing preservation. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on December 8, 2021.


Assuntos
Implante Coclear , Osteogênese , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Estudos Transversais , Feminino , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Pituitary ; 25(4): 587-601, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35616762

RESUMO

PURPOSE: To report the first experience of our multidisciplinary team with functional imaging using 11C-methionine positron emission tomography-computed tomography (11C-methionine PET-CT) co-registered with MRI (Met-PET/MRICR) in clinical decision making and surgical planning of patients with difficult to treat prolactinoma. METHODS: In eighteen patients with prolactinoma, referred to our tertiary referral centre because of intolerance or resistance for dopamine agonists (DA), Met-PET/MRICR was used to aid decision-making regarding therapy. RESULTS: Met-PET/MRICR was positive in 94% of the patients. MRI and Met-PET/MRICR findings were completely concordant in five patients, partially concordant in nine patients, and non-concordant in four patients. In five patients Met-PET/MRICR identified lesion(s) that were retrospectively also visible on MRI. Met-PET/MRICR was false negative in one patient, with a cystic adenoma on conventional MRI. Thirteen patients underwent transsphenoidal surgery, with nine achieving full biochemical remission, two clinical improvement and near normalized prolactin levels, and one patient clinical improvement with significant tumour reduction. Hence, nearly all patients (94%) were considered to have a positive outcome. Permanent complication rate was low. Three patients continued DA, two patients have a wait and scan policy. CONCLUSION: Met-PET/MRICR can provide additional information to guide multidisciplinary preoperative and intraoperative decision making in selected cases of prolactinoma. This approach resulted in a high remission rate with a low rate of complications in our expert centre.


Assuntos
Neoplasias Hipofisárias , Prolactinoma , Tomada de Decisões , Humanos , Imageamento por Ressonância Magnética/métodos , Metionina , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/patologia , Neoplasias Hipofisárias/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Prolactinoma/diagnóstico por imagem , Prolactinoma/cirurgia , Estudos Retrospectivos
5.
Eur Arch Otorhinolaryngol ; 279(10): 4735-4743, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35041067

RESUMO

PURPOSE: The aim of this study was to evaluate the intracochlear position of the Slim Modiolar Electrode (SME) after insertion via the extended Round Window (eRW) approach, and to correlate this with residual hearing preservation and speech perception outcomes. METHODS: Twenty-three adult participants, consecutively implanted with the SME via the eRW approach, were included in this prospective, single-center, observational study. Electrode position was evaluated intra-operatively using X-ray fluoroscopy and TIM measurement, and post-operatively using ultra-high resolution CT. Residual hearing [threshold shift in PTA between pre- and post-operative measurement, relative hearing preservation (RHP%)] and speech perception were evaluated at 2 and 12 months after surgery. RESULTS: In each of the 23 participants, complete scala tympani positioning of the electrode array could be achieved. In one participant, an initial tip fold-over was corrected during surgery. Average age at implantation was 63.3 years (SD 13.3, range 28-76) and mean preoperative residual hearing was 81.5 dB. The average post-operative PTA threshold shift was 16.2 dB (SD 10.8) at 2 months post-operatively, corresponding with a RHP% score of 44% (SD 34.9). At 12 months, the average RHP% score decreased to 37%. Postoperative phoneme scores improved from 27.1% preoperatively, to 72.1% and 82.1% at 2 and 12 months after surgery, respectively. CONCLUSION: Use of the eRW approach results in an increased likelihood of complete scala tympani insertion when inserting the SME, with subsequent excellent levels of speech perception. However, residual hearing preservation was found to be moderate, possibly as a result of the extended round window approach, emphasizing that it is not an all-purpose approach for inserting this particular electrode array.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Cóclea/cirurgia , Implante Coclear/métodos , Eletrodos Implantados , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Ear Hear ; 42(4): 949-960, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33480623

RESUMO

OBJECTIVES: The primary objective of this study is to identify the biographic, audiologic, and electrode position factors that influence speech perception performance in adult cochlear implant (CI) recipients implanted with a device from a single manufacturer. The secondary objective is to investigate the independent association of the type of electrode (precurved or straight) with speech perception. DESIGN: In a cross-sectional study design, speech perception measures and ultrahigh-resolution computed tomography scans were performed in 129 experienced CI recipients with a postlingual onset of hearing loss. Data were collected between December 2016 and January 2018 in the Radboud University Medical Center, Nijmegen, the Netherlands. The participants received either a precurved electrode (N = 85) or a straight electrode (N = 44), all from the same manufacturer. The biographic variables evaluated were age at implantation, level of education, and years of hearing loss. The audiometric factors explored were preoperative and postoperative pure-tone average residual hearing and preoperative speech perception score. The electrode position factors analyzed, as measured from images obtained with the ultrahigh-resolution computed tomography scan, were the scalar location, angular insertion depth of the basal and apical electrode contacts, and the wrapping factor (i.e., electrode-to-modiolus distance), as well as the type of electrode used. These 11 variables were tested for their effect on three speech perception outcomes: consonant-vowel-consonant words in quiet tests at 50 dB SPL (CVC50) and 65 dB SPL (CVC65), and the digits-in-noise test. RESULTS: A lower age at implantation was correlated with a higher CVC50 phoneme score in the straight electrode group. Other biographic variables did not correlate with speech perception. Furthermore, participants implanted with a precurved electrode and who had poor preoperative hearing thresholds performed better in all speech perception outcomes than the participants implanted with a straight electrode and relatively better preoperative hearing thresholds. After correcting for biographic factors, audiometric variables, and scalar location, we showed that the precurved electrode led to an 11.8 percentage points (95% confidence interval: 1.4-20.4%; p = 0.03) higher perception score for the CVC50 phonemes compared with the straight electrode. Furthermore, contrary to our initial expectations, the preservation of residual hearing with the straight electrode was poor, as the median preoperative and the postoperative residual hearing thresholds for the straight electrode were 88 and 122 dB, respectively. CONCLUSIONS: Cochlear implantation with a precurved electrode results in a significantly higher speech perception outcome, independent of biographic factors, audiometric factors, and scalar location.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Estudos Transversais , Humanos , Resultado do Tratamento
7.
Eur Arch Otorhinolaryngol ; 277(2): 343-350, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31650350

RESUMO

PURPOSE: In cochlear implantation (CI), the two factors that are determined by the surgeon with a potential significant impact on the position of the electrode within the cochlea and the potential outcome, are the surgical technique and electrode type. The objective of this prospective study was to evaluate the position of the slim, perimodiolar electrode (SPE), and to study the influence of the SPE position on CI outcome. METHODS: Twenty-three consecutively implanted, adult SPE candidates were included in this prospective cohort study conducted between December 2016 and April 2019. Mean age at surgery was 59.5 years. Mean preoperative residual hearing was 92.2 dB. Intra-operative fluoroscopy and high-resolution computed tomography scans were performed to evaluate electrode position after insertion using a cochleostomy (CS) approach. Follow-up was 12 months after implantation; residual hearing (6-8 weeks) and speech perception (6-8 weeks and 12 months) were evaluated in relation to the intracochlear SPE position. RESULTS: In most patients in whom the SPE was positioned in the scala tympani residual hearing was preserved [mean absolute increase in PTA of 4.4 dB and 77.2% relative hearing preservation (RHP%)]. Translocation into the scala vestibuli occurred in 36% of the insertions, resulting in a mean absolute increase in PTA of 17.9 dB, and a RHP% of 19.2%. Participants with a translocation had poorer speech perception scores at 12-month follow-up. CONCLUSION: Given the incidence of CS-associated translocations with the SPE and the negative effect on outcome, it is advised to insert the SPE using the (extended) round window approach.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cóclea/diagnóstico por imagem , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Tomografia Computadorizada de Feixe Cônico , Feminino , Fluoroscopia , Perda Auditiva/diagnóstico , Perda Auditiva/diagnóstico por imagem , Testes Auditivos , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese/etiologia , Janela da Cóclea/cirurgia , Rampa do Tímpano/cirurgia
8.
Am J Med Genet C Semin Med Genet ; 175(4): 450-464, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29168326

RESUMO

"CHARGE syndrome" is a complex syndrome with high and extremely variable comorbidity. As a result, clinicians may struggle to provide accurate and comprehensive care, and this has led to the publication of several clinical surveillance guidelines and recommendations for CHARGE syndrome, based on both single case observations and cohort studies. Here we perform a structured literature review to examine all the existing advice. Our findings provide additional support for the validity of the recently published Trider checklist. We also identified a gap in literature when reviewing all guidelines and recommendations, and we propose a guideline for neuroradiological evaluation of patients with CHARGE syndrome. This is of importance, as patients with CHARGE are at risk for peri-anesthetic complications, making recurrent imaging procedures under anesthesia a particular risk in clinical practice. However, comprehensive cranial imaging is also of tremendous value for timely diagnosis, proper treatment of symptoms and for further research into CHARGE syndrome. We hope the guideline for neuroradiological evaluation will help clinicians provide efficient and comprehensive care for individuals with CHARGE syndrome.


Assuntos
Síndrome CHARGE/diagnóstico , Síndrome CHARGE/terapia , Encéfalo/anormalidades , Síndrome CHARGE/genética , Gerenciamento Clínico , Humanos , Neuroimagem/métodos , Guias de Prática Clínica como Assunto
10.
Audiol Neurootol ; 21(5): 316-325, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27871074

RESUMO

The HiFocus Mid-Scala (MS) electrode array has recently been introduced onto the market. This precurved design with a targeted mid-scalar intracochlear position pursues an atraumatic insertion and optimal distance for neural stimulation. In this study we prospectively examined the angular insertion depth achieved and speech perception outcomes resulting from the HiFocus MS electrode array for 6 months after implantation, and retrospectively compared these with the HiFocus 1J lateral wall electrode array. The mean angular insertion depth within the MS population (n = 96) was found at 470°. This was 50° shallower but more consistent than the 1J electrode array (n = 110). Audiological evaluation within a subgroup, including only postlingual, unilaterally implanted, adult cochlear implant recipients who were matched on preoperative speech perception scores and the duration of deafness (MS = 32, 1J = 32), showed no difference in speech perception outcomes between the MS and 1J groups. Furthermore, speech perception outcome was not affected by the angular insertion depth or frequency mismatch.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Surdez/reabilitação , Percepção da Fala , Adulto , Idoso , Audiometria , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
11.
Audiol Neurootol ; 21(1): 54-67, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26891130

RESUMO

OBJECTIVES: In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. DESIGN: A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and the distance to the modiolus of each electrode contact were determined using high-resolution CT scanning. The threshold levels (T-levels) and maximum comfort levels (M-levels) at 1 year of follow-up were determined. The degree of speech perception of the subjects was evaluated during routine clinical follow-up. RESULTS: The depths of insertion of all the electrode contacts were determined. The distance to the modiolus was significantly smaller at the basal and apical cochlear parts compared with that at the middle of the cochlea (p < 0.05). The T-levels increased toward the basal end of the cochlea (3.4 dB). Additionally, the M-levels, which were fitted in our clinic using a standard profile, also increased toward the basal end, although with a lower amplitude (1.3 dB). Accordingly, the dynamic range decreased toward the basal end (2.1 dB). No correlation was found between the distance to the modiolus and the T-level or the M-level. Furthermore, the correlation between the insertion depth and stimulation levels was not affected by the duration of deafness, age at implantation or the time since implantation. Additionally, the T-levels showed a significant correlation with the speech perception scores (p < 0.05). CONCLUSIONS: The stimulation levels of the cochlear implants were affected by the intracochlear position of the electrode contacts, which were determined using postoperative CT scanning. Interestingly, these levels depended on the insertion depth, whereas the distance to the modiolus did not affect the stimulation levels. The T-levels increased toward the basal end of the cochlea. The level profiles were independent of the overall stimulation levels and were not affected by the biographical data of the patients, such as the duration of deafness, age at implantation or time since implantation. Further research is required to elucidate how fitting using level profiles with an increase toward the basal end of the cochlea benefits speech perception. Future investigations may elucidate an explanation for the effects of the intracochlear electrode position on the stimulation levels and might facilitate future improvements in electrode design.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Surdez/cirurgia , Ajuste de Prótese/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Limiar Auditivo , Cóclea/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Percepção da Fala , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
12.
Ear Hear ; 37(4): 473-82, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26760199

RESUMO

OBJECTIVES: To assess the possibility to define a preferable range for electrode array insertion depth and surgical insertion distance for which frequency mismatch is minimalized. To develop a surgical insertion guidance tool by which a preferred target angle can be attained using preoperative available anatomical data and surgically controllable insertion distance. DESIGN: Multiplanar reconstructions of pre- and post-operative CT scans were evaluated in a population of 336 patients implanted with the CII HiFocus1 or HiFocus1J implant (26 bilaterally implantees included). Cochlear radial distances were measured on four measurement axes on the preoperative CT scan. Electrode contact positions were obtained in angular depth, distance from the round window and to the modiolus center. Frequency mismatch was calculated based on the yielded frequency as a function of the angular position per contact. Cochlear diameters were clustered into three cochlear size groups with K-sample clustering. Using spiral fitting and general linear regression modeling, the feasibility of different insertion models with cochlear size measures and surgical insertion as input parameters was analyzed. The final developed model was internally validated with bootstrapping to calculate the optimism-corrected R. RESULTS: Frequency mismatch was minimalized for surgical insertion of 6.7 mm and insertion depth of 484°. Cochlear size clusters were derived consisting of a "small" (N = 117), "medium" (N = 171), and "large" (N = 74) cluster with mean insertion depths of 506°, 480°, and 441°, respectively. The relation between surgical insertion (LE16) and insertion depth (θE1) differed significantly between the three clusters (p < 0.01). The insertion models based on spiral fitting showed an R of 62% with mean of the residuals of -0.5 mm (SD = 1.2 mm) between the measured and predicted LE16 and a mean of 15° (SD = 83°) for θE1. Using general linear regression modeling resulted in a residual mean of -0.2 µm (SD = 0.9 mm) for measured and predicted LE16 and 0.01° (SD = 33°) for θE1. The model derived from general linear regression modeling resulted in an R of 78.7% and was validated with bootstrapping. An optimism of 0.6% was calculated using this analysis. The optimism-corrected R of 78.1% defined the estimated performance of the final insertion model in future populations. CONCLUSIONS: A minimal frequency mismatch for an electrode array design can be calculated to define preferable electrode array position within the cochlea. In general, to achieve a minimal frequency mismatch, the surgeon should attempt to insert the HiFocus 1 or 1J array around 6, 7, or 8 mm in case of a "small," "medium," or "large" cochlea, respectively. Development of different insertion models showed the feasibility of obtaining a surgical guidance tool to lead the surgeon during cochlear implantation depending on individual cochlear size and controllable surgical distance. The developed final insertion model predicted 78.1% of the variation in final HiFocus1 or HiFocus1J implant position.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Surdez/reabilitação , Eletrodos Implantados , Rampa do Vestíbulo/cirurgia , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Rampa do Vestíbulo/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Audiol Neurootol ; 20(3): 202-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25924706

RESUMO

OBJECTIVES: To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population. DESIGN: The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics. Phoneme and word score averages for the 1- and 2-year follow-up were calculated for 41 prelingually deaf and 162 postlingually deaf patients. Analyses to reveal correlations between these performance outcomes and 6 position-related variables (angle of most basal electrode contact, surgical insertion angle, surgical insertion, wrapping factor, angular insertion depth, linear insertion depth) were executed. The scalar location, as an indication for the presence of intracochlear trauma, and modiolus proximity beyond the basal turn were not evaluated in this study. In addition, different patient-specific variables (age at implantation, age at onset of hearing loss, duration of deafness, preoperative phoneme and word scores) were tested for correlation with performance. RESULTS: The performance scores of prelingual patients were correlated with age at onset of hearing loss, duration of deafness and preoperative scores. For the postlingual patients, performance showed correlations with all 5 patient-specific variables. None of the 6 position-related variables influenced speech perception in cochlear implant patients. CONCLUSIONS: Although several patient-specific variables showed correlations with speech perception outcomes, not one of the studied angular and linear position-related variables turned out to have a demonstrable influence on performance.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Surdez/cirurgia , Percepção da Fala/fisiologia , Adulto , Idoso , Cóclea/fisiopatologia , Surdez/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Mov Disord ; 29(10): 1312-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24862624

RESUMO

BACKGROUND: Little is known about the swallowing disturbances of patients with Huntington's disease; therefore, we developed the Huntington's Disease Dysphagia Scale. METHODS: The scale was developed in four stages: (1) item generation, (2) comprehension testing, (3) evaluation of reliability, (4) item reduction and validity testing. The questionnaire was presented twice to 50 Huntington's disease patients and their caregivers. The Kruskal-Wallis test was used to evaluate whether the severity of swallowing difficulties increased with advancing disease. Pearson's correlation coefficient was used to examine the construct validity with the Swallowing Disturbance Questionnaire. RESULTS: The final version contained 11 items with five response options and exhibited a Cronbach's alpha coefficient of 0.728. The severity of swallowing difficulties was significantly higher in more advanced Huntington's disease. The correlation with the Swallowing Disturbance Questionnaire was 0.734. CONCLUSION: We developed a valid and reliable 11-item scale to measure the severity of dysphagia in Huntington's disease.


Assuntos
Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/etiologia , Doença de Huntington/complicações , Índice de Gravidade de Doença , Adulto , Idoso , Cuidadores/psicologia , Feminino , Humanos , Doença de Huntington/psicologia , Masculino , Pessoa de Meia-Idade , Psicometria , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Inquéritos e Questionários
15.
Ear Hear ; 35(1): e9-20, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24196418

RESUMO

OBJECTIVES: To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance. DESIGN: Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and postoperative CT scans in a population of 336 patients (including 26 bilaterally implanted ones) with a CII HiFocus1 or HiRes90K HiFocus1J implant. Variations in cochlear diameter and cochlear canal size were analyzed. The relationship between the outer and inner walls was investigated. Size differences based on sex, age, and ear side were investigated using linear mixed models. Two new methods, spiral fitting and principal component analysis, were proposed to describe cochlear shape, and the goodness of fit was investigated. The relationship between cochlear shape and electrode position, in terms of modiolus proximity and insertion depth, was analyzed using clustering, one-way analysis of variance (ANOVA) and simple linear regression analysis. RESULTS: Large variations in cochlear morphology were found, with cochlear canal sizes ranging from 0.98 to 2.96 mm and average cochlear diameters between 8.85 and 5.92 mm (with standard deviations of around 0.4 mm). The outer and inner walls were significantly correlated (p < 0.01), and a size difference of 4% in favor of males was found. Spiral fitting shows good alignment of the true measurements, with residuals having a mean of 0.01 mm and a standard deviation of 0.29 mm. Principal component analysis (PCA) showed that the use of one component, which describes size, is sufficient to explain 93.6% of the cochlear shape variance. A significant sex difference was also found with spiral fitting and PCA. Cochlear size was found to have a significant influence on modiolus proximity and insertion depth of the electrode (p < 0.01). Cochlear size explained around 13% of the variance in electrode position. When cochlear size was combined with surgical insertion, more than 81% of the variance in insertion depth can be explained. CONCLUSIONS: This study demonstrates a large variety in cochlear morphology, which significantly impacts electrode position in terms of modiolus proximity and insertion depth. The effect size is, however, relatively small compared with surgical insertion distance. PCA is shown to be an accurate reduction method for describing cochlear shape.


Assuntos
Cóclea/anatomia & histologia , Implante Coclear/métodos , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Cóclea/diagnóstico por imagem , Implantes Cocleares , Feminino , Humanos , Lactente , Modelos Lineares , Masculino , Tamanho do Órgão , Análise de Componente Principal , Tomografia Computadorizada por Raios X , Adulto Jovem
16.
Otolaryngol Head Neck Surg ; 169(6): 1582-1589, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37555251

RESUMO

OBJECTIVE: Validation of automated 2-dimensional (2D) diameter measurements of vestibular schwannomas on magnetic resonance imaging (MRI). STUDY DESIGN: Retrospective validation study using 2 data sets containing MRIs of vestibular schwannoma patients. SETTING: University Hospital in The Netherlands. METHODS: Two data sets were used, 1 containing 1 scan per patient (n = 134) and the other containing at least 3 consecutive MRIs of 51 patients, all with contrast-enhanced T1 or high-resolution T2 sequences. 2D measurements of the maximal extrameatal diameters in the axial plane were automatically derived from a 3D-convolutional neural network compared to manual measurements by 2 human observers. Intra- and interobserver variabilities were calculated using the intraclass correlation coefficient (ICC), agreement on tumor progression using Cohen's kappa. RESULTS: The human intra- and interobserver variability showed a high correlation (ICC: 0.98-0.99) and limits of agreement of 1.7 to 2.1 mm. Comparing the automated to human measurements resulted in ICC of 0.98 (95% confidence interval [CI]: 0.974; 0.987) and 0.97 (95% CI: 0.968; 0.984), with limits of agreement of 2.2 and 2.1 mm for diameters parallel and perpendicular to the posterior side of the temporal bone, respectively. There was satisfactory agreement on tumor progression between automated measurements and human observers (Cohen's κ = 0.77), better than the agreement between the human observers (Cohen's κ = 0.74). CONCLUSION: Automated 2D diameter measurements and growth detection of vestibular schwannomas are at least as accurate as human 2D measurements. In clinical practice, measurements of the maximal extrameatal tumor (2D) diameters of vestibular schwannomas provide important complementary information to total tumor volume (3D) measurements. Combining both in an automated measurement algorithm facilitates clinical adoption.


Assuntos
Neuroma Acústico , Humanos , Neuroma Acústico/diagnóstico por imagem , Neuroma Acústico/patologia , Inteligência Artificial , Estudos Retrospectivos , Algoritmos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
17.
Adv Radiat Oncol ; 8(3): 101149, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36691449

RESUMO

Purpose: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. Methods and Materials: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. Results: The average GTV was significantly larger on T1gd (0.57cm3) compared with T2 (0.51cm3, P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. Conclusions: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed.

18.
Front Neurol ; 14: 1239422, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37719762

RESUMO

Background: Ménière's disease (MD) is a chronic inner ear disorder with a multifactorial etiology. Decreased visualization of the endolymphatic duct (ED) and sac (ES) is thought to be associated with MD, although controversy exists about whether this finding is specific to MD. Recent literature has revealed that two distinct ES pathologies, developmental hypoplasia and epithelial degeneration, can be distinguished in MD using the angular trajectory of the vestibular aqueduct (ATVA) or ED-ES system as a radiographic surrogate marker. It has been suggested that these two subtypes are associated with distinct phenotypical features. However, the clinical differences between the ATVA subtypes require further validation. Research objective: The objective of this study is to investigate whether (1) non-visualization of the ED-ES system is a discriminative radiological feature for MD in a cohort of vertigo-associated pathologies (VAPs) and whether (2) different angular trajectories of the ED-ES system in MD are associated with distinguishable clinical features. Setting: The study was conducted in the Vertigo Referral Center (Haga Teaching Hospital, The Hague, the Netherlands). Methods: We retrospectively assessed 301 patients (187 definite MD and 114 other VAPs) that underwent 4h-delayed 3D FLAIR MRI. We evaluated (1) the visibility of the ED-ES system between MD and other VAP patients and (2) measured the angular trajectory of the ED-ES system. MD patients were stratified based on the angular measurements into αexit ≤ 120° (MD-120), αexit 120°-140° (MD-intermediate), or αexit ≥ 140° (MD-140). Correlations between ATVA subgroups and clinical parameters were evaluated. Results: Non-visualization of the ED-ES system was more common in definite MD patients compared with other VAPs (P < 0.001). Among definite MD patients, the MD-140 subtype demonstrated a longer history of vertigo (P = 0.006), a higher prevalence of bilateral clinical disease (P = 0.005), and a trend toward a male preponderance (p = 0.053). No significant differences were found between ATVA subgroups regarding the presence or severity of auditory symptoms, or the frequency of vertigo attacks. Conclusion: Non-visualization of the ED-ES system is significantly associated with MD. Among MD patients with a visible ED-ES system, we demonstrated that the MD-140 subtype is associated with a longer disease duration, a higher prevalence of bilateral MD, and a trend toward a male preponderance.

19.
Ophthalmol Retina ; 7(2): 178-188, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35840053

RESUMO

OBJECTIVE: Conventionally, ocular proton therapy (PT) is planned using measurements obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative assessments. Owing to the recent advances in magnetic resonance imaging (MRI) of uveal melanoma (UM), it is possible to acquire high-resolution 3-dimensional images of the eye, providing the opportunity to incorporate MRI in ocular PT planning. In this study, we described how these measurements can be obtained using MRI, compared the MRI-based measurements with conventional ophthalmic measurements, and identified potential pitfalls for both modalities. DESIGN: Cross-sectional study. SUBJECTS: Data from 23 consecutive patients with UM treated with PT were retrospectively evaluated. METHODS: Magnetic resonance imaging-based measurements of axial length, tumor height and basal diameter, and marker-tumor distances were compared with the conventional ophthalmic measurements, and discrepancies were evaluated in a multidisciplinary setting. MAIN OUTCOME MEASURES: Tumor prominence and basal diameters on MRI and ultrasound, axial length on MRI and biometry, tumor-marker distances on MRI and measured intraoperatively. RESULTS: The mean absolute differences of the tumor height and basal diameter measurements between ultrasound and MRI were 0.57 mm and 1.44 mm, respectively. Larger absolute differences in height and basal diameter were observed when the full tumor extent was not visible on ultrasound (0.92 mm and 1.67 mm, respectively) compared with when the full tumor extent was visible (0.44 mm and 1.15 mm, respectively). When the full tumor was not visible on ultrasound, MRI was considered more reliable. Tumor-marker distances measured using MRI and intraoperative techniques differed < 1 mm in 55% of the markers. For anteriorly located and mushroom-shaped tumors (25% of the markers), MRI provided more accurate measurements. In flat UM (15% of the markers), however, it was difficult to delineate the tumor on MRI. The mean absolute difference in axial length between optical biometry and MRI was 0.50 mm. The presence of the tumor was found to influence optical biometry in 15 of 22 patients; the remaining patients showed a better agreement (0.30 mm). Magnetic resonance imaging-based biometry was considered more reliable in patients with UM. CONCLUSIONS: Magnetic resonance imaging allowed for the 3-dimensional assessment of the tumor and surrounding tissue. In specific patients, it provided a more reliable measurement of axial length, tumor dimensions, and marker-tumor distances and could contribute to a more accurate treatment planning. Nevertheless, a combined evaluation remains advised, especially for flat UM.


Assuntos
Terapia com Prótons , Humanos , Estudos Transversais , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
20.
Audiol Neurootol ; 17(5): 275-81, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22627581

RESUMO

OBJECTIVE: It was the aim of this study to investigate the occurrence of electrode migration of a cochlear implant in patients with and without complaints. METHODS: We performed a retrospective case review in a tertiary referral center. The electrode position was evaluated in 35 cochlear implantees, 16 with a CII HiFocus1 (non-positioner) and 19 with a HiRes90K HiFocus1J, using multiplanar reconstructions of the postoperative CT scans. Of 5 patients, a second scan was obtained to evaluate complaints of performance drop, vertigo, tinnitus, headache or nonauditory stimulation. Displacements of the electrode contacts were calculated and displacements of >1 mm were considered a migration. The possible correlation with implant type, insertion depth or presence of complaints was analyzed. RESULTS: Migrations were detected in 10 patients (29%). There was a significant effect of the implant type in favour of the HiFocus1, but no relation with the original insertion depth of the device. In the 5 patients scanned because of complaints, two migrations were detected. CONCLUSIONS: In our patient population, electrode migration was not uncommon and turned out to occur in patients with and without complaints.


Assuntos
Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Migração de Corpo Estranho/etiologia , Perda Auditiva Neurossensorial/cirurgia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Doenças Assintomáticas , Criança , Pré-Escolar , Eletrodos Implantados/efeitos adversos , Seguimentos , Cefaleia/etiologia , Humanos , Lactente , Pessoa de Meia-Idade , Estudos Retrospectivos , Zumbido/etiologia , Vertigem/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA