Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
2.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37350404

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do Tratamento
3.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37724686

RESUMO

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Humanos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Bradicardia , Progressão da Doença , Trifosfato de Adenosina
4.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794691

RESUMO

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos de Casos e Controles , Morte Súbita Cardíaca/etiologia , Estudos Retrospectivos , Resultado do Tratamento
5.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37536671

RESUMO

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Cardiomiopatias , Canalopatias , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Canalopatias/complicações , Canalopatias/terapia , Resultado do Tratamento , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Sistema de Registros
6.
J Cardiovasc Electrophysiol ; 33(1): 81-89, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797012

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the transvenous ICD. No study has yet compared S-ICD and transvenous ICD by assessing patient acceptance as a patient-centered outcome. OBJECTIVE: To evaluate the patient acceptance of the S-ICD and to investigate its association with clinical and implantation variables. In patients with symptomatic heart failure and reduced ejection fraction (HFrEF), the acceptance of the S-ICD was compared with a control group of patients who received a transvenous ICD. METHODS: Patient acceptance was calculated with the Florida Patient Acceptance Survey (FPAS) which measures four factors: return to function (RTF), device-related distress (DRD), positive appraisal (PA), and body image concerns (BIC). The survey was administered 12 months after implantation. RESULTS: 176 patients underwent S-ICD implantation. The total FPAS and the single factors did not differ according to gender, body habitus, or generator positioning. Patients with HFrEF had lower FPAS and RTF. Younger patients showed better RTF (75 [56-94] vs. 56 [50-81], p = .029). Patients who experienced device complications or device therapies showed higher DRD (40 [35-60] vs. 25 [10-50], p = .019). Patients with HFrEF receiving the S-ICD had comparable FPAS, RTF, DRD, and BIC to HFrEF patients implanted with the transvenous ICD while exhibited significantly better PA (88 [75-100] vs. 81 [63-94], p = .02). CONCLUSIONS: Our analysis revealed positive patient acceptance of the S-ICD, even in groups at risk of more distress such as women or patients with thinner body habitus, and regardless of the generator positioning. Among patients receiving ICDs for HFrEF, S-ICD was associated with better PA versus transvenous ICD.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Inquéritos e Questionários , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33969578

RESUMO

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Assuntos
Desfibriladores Implantáveis , Índice de Massa Corporal , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Tela Subcutânea , Resultado do Tratamento
8.
Europace ; 22(9): 1401-1408, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32681177

RESUMO

AIMS: Optimal management of redundant or malfunctioning leads is controversial. We aimed to assess safety and efficacy of mechanical transvenous lead extraction (TLE) in patients with abandoned leads. METHODS AND RESULTS: Consecutive TLE procedures performed in our centre from January 2009 to December 2017 were considered. We evaluated the safety and efficacy of mechanical TLE in patients with abandoned (Group 1) compared to non-abandoned (Group 2) leads. We analysed 1210 consecutive patients that required transvenous removal of 2343 leads. Group 1 accounted for 250 patients (21%) with a total of 617 abandoned leads (26%). Group 2 comprised 960 patients (79%) with 1726 leads (74%). The total number of leads (3.0 vs. 2.0), dwelling time of the oldest lead (108.00 months vs. 60.00 months) and infectious indications for TLE were higher in Group 1. Clinical success was achieved in 1168 patients (96.5%) with a lower rate in Group 1 (90.4% vs. 98.1%; P < 0.001). Major complications occurred in only 9 patients (0.7%), without significant differences among the two groups. The presence of one or more abandoned leads [odds ratio (OR) 3.47; 95% confidence interval (CI) 1.07-11.19; P = 0.037] and dwelling time of the oldest lead (OR 1.01 for a month; 95% CI 1.01-1.02; P < 0.001) were associated with a higher risk of clinical failure. CONCLUSION: Transvenous mechanical lead extraction is a safe procedure also in high-risk settings, as patients with abandoned leads. Success rate resulted a bit lower, especially in the presence of abandoned leads with long implantation time.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Falha de Equipamento , Humanos , Razão de Chances , Estudos Retrospectivos , Resultado do Tratamento
9.
Europace ; 22(12): 1822-1829, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33118017

RESUMO

AIMS: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. METHODS AND RESULTS: We analysed consecutive patients undergoing S-ICD implantation. The χ2 test and regression analysis were used to determine the association between the PRAETORIAN score and implantation technique. Two hundred and thirteen patients were enrolled. The S-ICD generator was positioned in an IM pocket in 174 patients (81.7%) and the two-incision approach was adopted in 199 (93.4%). According to the PRAETORIAN score, the risk of conversion failure was classified as low in 198 patients (93.0%), intermediate in 13 (6.1%), and high in 2 (0.9%). Patients undergoing the two-incision and IM technique were more likely to have a low (<90) PRAETORIAN score than those undergoing the three-incision and subcutaneous technique (two-incision: 94.0% vs. three-incision: 78.6%; P = 0.004 and IM: 96.0% vs. subcutaneous: 79.5%; P = 0.001). Intermuscular plus two-incision technique was associated with a low-risk PRAETORIAN score (hazard ratio 3.76; 95% confidence interval 1.01-14.02; P = 0.04). Shock impedance was lower in PRAETORIAN low-risk patients than in intermediate-/high-risk categories (66 vs. 96 Ohm; P = 0.001). The PRAETORIAN score did not predict shock failure at 65 J. CONCLUSION: In this cohort of S-ICD recipients, combining the two-incision technique and IM generator implantation yielded the lowest PRAETORIAN score values, indicating optimal defibrillation system position. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Fatores de Risco
10.
Europace ; 21(1): 114-120, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29893837

RESUMO

AIMS: To demonstrate the feasibility and long-term performances of a non-apical Micra pacemaker implantation. METHODS AND RESULTS: Fifty-two consecutive patients underwent Micra implantation, targeting a non-apical site of delivery when feasible. Each patient received a regular follow-up (mean 13 ± 9 months). The first 17 patients were also enrolled in the Micra transcatheter pacing system trial (Group 1); the remaining ones presented broader indications and included post-extraction subjects (Group 2). In 19 of 52 patients (Group 1: 6%, Group 2: 51%; P = 0.002) Micra was implanted because of high-risk characteristics that discouraged the implantation of a traditional pacemaker. In 31 of 52 patients (60%) Micra was implanted in a non-apical location, with a lower rate of single delivery compared with apical sites (48% vs. 81%, P = 0.035), but without any impact on electrical performance. Pacing threshold remained optimal in the majority of patients (94%), regardless of the site of implantation (apical vs. non-apical location: 0.50 vs. 0.52 V/0.24 ms; P = 0.856) and group membership, with only 6% of the subjects showing elevated values (mean 1.92 ± 0.92 V/0.24 ms) at the last follow-up. No device-related adverse events were registered. CONCLUSION: Micra pacemaker implant is a safe and effective procedure even in a real life cohort of high-risk patients. A non-apical site of implantation is feasible in the majority of patients allowing stable electrical performance at long-term follow-up.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
11.
Europace ; 21(8): 1229-1236, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31180481

RESUMO

AIMS: We aimed at investigating the feasibility and outcome of Micra implant in patients who have previously undergone transvenous lead extraction (TLE), in comparison to naïve patients implanted with the same device. METHODS AND RESULTS: Eighty-three patients (65 males, 78.31%; 77.27 ± 9.96 years) underwent Micra implant at our centre. The entire cohort was divided between 'post-extraction' (Group 1) and naïve patients (Group 2). In 23 of 83 patients (20 males, 86.96%; 73.83 ± 10.29 years), Micra was implanted after TLE. Indication to TLE was an infection in 15 patients (65.21%), leads malfunction in four (17.39%), superior vena cava syndrome in three (13.05%), and severe tricuspid regurgitation in one case (4.35%). The implant procedure was successful in all patients and no device-related events occurred at follow-up (median: 18 months; interquartile range: 1-24). No differences were observed between groups in fluoroscopy time (13.88 ± 10.98 min vs. 13.15 ± 6.64 min, P = 0.45), single device delivery (Group 1 vs. Group 2: 69.56% vs. 55%, P = 0.22), electrical performance at implant and at 12-month follow-up (Group 1 vs. Group 2: pacing threshold 0.48 ± 0.05 V/0.24 ms vs. 0.56 ± 0.25 V/0.24 ms, P = 0.70; impedance 640 ± 148.83 Ohm vs. 583.43 ± 99.7 Ohm, P = 0.27; and R wave amplitude 10.33 ± 2.88 mV vs. 12.62 ± 5.31 mV, P = 0.40). A non-apical site of implant was achievable in the majority of cases (72.3%) without differences among groups (78.26% vs. 70%; P = 0.42). CONCLUSION: Micra implant is an effective and safe procedure in patients still requiring a ventricular pacing after TLE, with similar electrical performance and outcome compared with naïve patients at long-term follow-up.


Assuntos
Estimulação Cardíaca Artificial , Microeletrodos , Marca-Passo Artificial , Implantação de Prótese/efeitos adversos , Infecções Relacionadas à Prótese , Idoso , Cateteres Cardíacos/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação/efeitos adversos , Reoperação/métodos , Tempo
12.
Curr Heart Fail Rep ; 12(1): 79-86, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25475178

RESUMO

The implantable cardioverter defibrillator is today an indisputable evidence-based treatment for cardiac sudden death both in primary and secondary prevention. However, trans-venous cardioverter defibrillator implantation still carries a not negligible risk of complications both acutely and during follow-up. Trans-venous endocardial lead is the weak link of implantable cardioverter defibrillator (ICD) technology being the source of most mechanical complications on vessels and heart structures and exposed to infection, malfunction and recalls. A totally subcutaneous defibrillation lead has recently been introduced in clinical practice. With the subcutaneous pulse generator forms a defibrillation system that leaves the vessels and the heart completely "untouched." Subcutaneous ICD has proven to be safe and effective in many clinical trials. Patients without pacing indications and at higher risk of complications from trans-venous lead implantation represent the perfect candidates to S-ICD technology. However, with technical improvement, it is reasonable to expect a further expansion of indications.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Ensaios Clínicos como Assunto , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Desenho de Prótese , Falha de Prótese
13.
Europace ; 16(9): 1356-62, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24696221

RESUMO

AIMS: We report our 15 years experience of a mechanical single-sheath technique with a multiple venous entry-site approach. We evaluated the effectiveness and safety of this technique in implantable defibrillator (ICD) lead extraction and investigated the potential association between clinical and lead-related factors and procedural complexity. METHODS AND RESULTS: The proposed technique consists of an initial attempt at manual traction, followed by mechanical dilatation performed through the venous entry-site and, if necessary, by crossover to the internal transjugular approach. The study cohort comprised 545 consecutive patients referred to our institution for transvenous lead extraction from January 1997 to December 2012. Initial manual traction resulted in the effective removal of 6% of leads. Mechanical dilatation increased the success rate to 89% when performed through the venous entry-site, and to 99% when subsequently attempted via the internal jugular vein. No major complications were associated with lead extraction. Dwell-time, a passive fixation mechanism and dual-coil lead design were independently associated with the need for mechanical dilatation. However, dwell-time was the only variable associated with crossover to the internal transjugular approach. Specifically, a dwell-time of 20 months best predicted the need for venous entry-site mechanical dilatation, while a value of 55 months predicted crossover to the internal transjugular approach. CONCLUSION: Mechanical transvenous extraction of ICD leads is a complex but safe and effective procedure. A longer lead dwell-time is associated with the need for mechanical dilatation and for crossover to the internal transjugular approach; this should be considered when planning the removal procedure. Moreover, passive lead fixation and dual-coil lead design predict a more challenging extraction procedure.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/métodos , Remoção de Dispositivo/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Veias Jugulares , Estudos de Coortes , Feminino , Humanos , Itália/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
Heart Rhythm ; 21(7): 1032-1039, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38403236

RESUMO

BACKGROUND: Epicardial access is often crucial for successful ventricular tachycardia (VT) ablation, but it is often burdened by significant procedural risk. Intentional coronary vein exit and intrapericardial CO2 insufflation (EpiCO2) can facilitate subxiphoid pericardial access. OBJECTIVE: This prospective study aimed to assess procedural feasibility, safety, and impact of the introduction of intrapericardial CO2 insufflation for epicardial access in a referral center for VT ablation. METHODS: All consecutive patients treated with epicardial VT ablation between November 2022 and January 2024 with the EpiCO2 technique at Pisa University Hospital were prospectively enrolled and compared in terms of feasibility, efficiency, and safety with a local retrospective cohort of patients treated with subxiphoid dry puncture between July 2018 and October 2022. RESULTS: Twenty-two consecutive patients (90.9% male; mean age, 54.3 years) underwent VT ablation with EpiCO2 during the study period. Epicardial access was achieved in all patients; median time from coronary sinus (CS) cannulation to epicardial access was 33 minutes. Intentional vein exit was successful in all cases, whereas CO2 insufflation was not feasible in 1 patient. There were no major complications and no significant bleeding. Since EpiCO2 introduction, epicardial approach utilization increased from 17.8% to 40% of all VT procedures. Comparison with 20 standard dry approach epicardial ablations showed no significant differences in terms of total procedural duration (322.5 [interquartile range, 296.75-363.75] minutes vs 359 [interquartile range, 323-409] minutes; P = .08). CONCLUSION: In our single-center experience, EpiCO2 was feasible and safe and led to significant increase in procedural volume without affecting total procedural time compared with standard dry puncture.


Assuntos
Dióxido de Carbono , Ablação por Cateter , Estudos de Viabilidade , Insuflação , Pericárdio , Taquicardia Ventricular , Humanos , Masculino , Feminino , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Pessoa de Meia-Idade , Insuflação/métodos , Dióxido de Carbono/administração & dosagem , Ablação por Cateter/métodos , Pericárdio/cirurgia , Estudos Prospectivos , Encaminhamento e Consulta , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos
15.
J Clin Med ; 12(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36983388

RESUMO

INTRODUCTION: Transcatheter atrial fibrillation (AF) ablation is still carried out with continuous invasive radial arterial blood pressure (IBP) monitoring in many centers. Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a noninvasive alternative method used in ICU. No data on CNBP reliability are available in the electrophysiology lab during AF ablation, where rhythm variations are common. BACKGROUND: The objective of the present study was to compare continuous noninvasive arterial pressure measured with the ClearSight device (Edwards Lifesciences, Irvine, CA, USA) with invasive radial artery pressure used as the reference method during AF ablation. METHODS: We prospectively enrolled 55 consecutive patients (age 62 ± 11 years, 80% male) undergoing transcatheter AF ablation (62% paroxysmal, 38% persistent) at our center. Standard of care IBP monitoring via a radial cannula and a contralateral noninvasive finger volume-clamp CNBP measurement device were positioned simultaneously in all patients for the entire procedure. Bland-Altman analysis was used to analyze the agreement between the two techniques. RESULTS: A total of 1219 paired measurements for systolic, diastolic, and mean arterial pressure were obtained in 55 subjects, with a mean (SD) of 22 (9) measurements per patient. The mean bias (SD) was -12.97 (13.89) mmHg for systolic pressure (level of agreement -14.24-40.20; correlation coefficient 0.84), -1.85 (8.52) mmHg for diastolic pressure (level of agreement -18.54-14.84; correlation coefficient 0.77) and 2.31 (8.75) mmHg for mean pressure (level of agreement -14.84-19.46; correlation coefficient 0.85). CONCLUSION: In patients undergoing AF ablation, CNBP monitoring with the ClearSight device showed acceptable agreement with IBP monitoring. Larger studies are needed to confirm the potential clinical implications of continuous noninvasive BP monitoring during AF ablation.

16.
Heart Rhythm O2 ; 4(10): 625-631, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37936665

RESUMO

Background: Existing data on the impact of sex differences on transvenous lead extraction (TLE) outcomes in cardiac device patients are limited. Objective: The purpose of this study was to evaluate the safety and efficacy of mechanical TLE in female patients. Methods: A retrospective evaluation was performed on 3051 TLE patients (group 1: female; group 2: male) from a single tertiary referral center. All individuals received treatment using single sheath mechanical dilation and various venous approaches as required. Results: Our analysis included 3051 patients (group 1: 750; group 2: 2301), with a total of 5515 leads handled with removal. Female patients were younger, had a higher left ventricular ejection fraction, and lower prevalences of coronary artery disease and diabetes mellitus. Infection was more common in male patients, whereas lead malfunction or abandonment were more frequent in female patients. Radiologic success was lower in female patients (95.8% vs 97.5%; P = .003), but there was no significant difference in clinical success between groups (97.2% vs 97.5%; P = .872). However, major complications (1.33% vs 0.60%; P <.001) and procedural mortality (0.4% vs 0.1%; P <.001) were higher in females compared to male patients. After multivariate analysis, female sex emerged as the only predictor of major complications, including deaths (odds ratio 3.96; 95% confidence interval 1.39-11.24). Conclusion: TLE using unpowered simple mechanical sheaths in female patients is safe and effective, but is associated with lower radiologic success and higher complication rates and mortality than in males. This finding underscores the importance of recognizing sex differences in TLE outcomes.

17.
Europace ; 14(4): 515-21, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22037541

RESUMO

AIMS: Few data are available on cardiac resynchronization therapy (CRT) after coronary sinus (CS) lead extraction. We aimed to evaluate the feasibility and mid-term outcome of transvenous CS lead reimplantation in a tertiary referral centre. METHODS AND RESULTS: We enrolled all patients who were referred to our hospital for CS lead removal from December 2000 through to May 2009 and were transvenously reimplanted with a CRT system before June 2009. One-year follow-up was performed to evaluate the incidence of infections, malfunctions, and mortality. We studied 113 consecutive patients undergoing successful CS lead extraction; 90 patients (75 male, mean age 69.2, range 35-84) underwent CS lead reimplantation (success rate: 95.6%; right-sided approach: 64.4%). In these patients, cardiac device infection was the usual indication for extraction (74.4%) and the subsequent reimplantation was performed after a median time of 3 days. The coronary sinus lead was usually positioned in the left ventricular (LV) postero-lateral region (62.2%); two procedures were required in two cases (2.2%). Balloon angioplasty was necessary for two patients (failure in one), whereas for the others we used a conventional implant technique. During follow-up, we observed four cases (4.4%) of local infection and six cases (6.7%) of system malfunction, requiring reintervention (two cases during the same hospitalization). One-year mortality was 5.5%. CONCLUSION: Left ventricular lead reimplantation is in our experience an effective and safe procedure, also in the case of right-sided approach. During follow-up, 1-year mortality was particularly low, whereas overall infection rate was higher than first implant procedures.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/prevenção & controle , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Seio Coronário/cirurgia , Eletrodos Implantados/estatística & dados numéricos , Implantação de Prótese/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Indústrias/estatística & dados numéricos , Itália/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Encaminhamento e Consulta/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
18.
Pacing Clin Electrophysiol ; 35(2): 215-22, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22132903

RESUMO

BACKGROUND: The aim of this study was to evaluate procedural outcomes of coronary sinus (CS) lead extraction, focusing on predictors and need for mechanical dilatation (MD) in the event that manual traction (MT) is ineffective. METHODS: The study assessed results in 145 consecutive patients (age 69 ± 10 years; 121 men)--a total of 147 CS pacing leads--who underwent transvenous CS lead removal between January 2000 and March 2010. RESULTS: All leads but one (99%) (implantation time 29 ± 25 months) were successfully removed. MT was effective in 103 (70%), and MD was necessary in the remaining 44 (30%) procedures. In multivariate analyses, unipolar design (odds ratio [OR] 3.22, 95% confidence interval [CI] 1.43-7.7; P = 0.005) and noninfective indication (OR 4.8, 95% CI 1.8-13, P = 0.002) were independent predictors for MD (P < 0.0001), with a predictive trend for prior cardiac surgery (OR 2.2, 95% CI 0.98-5.26; P = 0.06). Five (3.4%) complex procedures required a transfemoral vein approach (TFA) or repeat procedure. No deaths occurred, and there was one major complication (0.7%), cardiac tamponade, after MT. No complication predictors were identified. CONCLUSIONS: CS leads were safely and effectively removed in nearly all patients, and 70% were removed with MT alone; 30% required MD. Preoperative predictors suggesting the need for MD or TFA were noninfective indication and unipolar lead design. Complications were rare, and there was no predictable pattern among MT or MD removal techniques.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/mortalidade , Seio Coronário/cirurgia , Remoção de Dispositivo/mortalidade , Eletrodos Implantados/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Idoso , Procedimentos Cirúrgicos Cardiovasculares/métodos , Remoção de Dispositivo/métodos , Feminino , Humanos , Itália/epidemiologia , Masculino , Prevalência , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
19.
J Interv Card Electrophysiol ; 64(3): 773-781, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35277775

RESUMO

BACKGROUND: The study aimed to explore the resolution of left atrial and left atrial appendage (LAA) spontaneous echo-contrast or thrombus in patients with nonvalvular atrial fibrillation/flutter (AF/AFL) under chronic oral anticoagulation (OAC). METHODS: A single-center retrospective analysis of patients who underwent a transesophageal echocardiography (TOE) for an electrical cardioversion was conducted. RESULTS: Among 277 TOE performed, 73 cases (26%) of LAA echo-contrast or thrombus were detected, 53 patients with LAA/LA echo-contrast (19%) and 20 (7%) with a thrombus. All patients were under chronic anticoagulation with a VKA (65%) or with a NOAC (35%). The Echo-contrast Group maintained the same OAC strategy in 49 patients (93%). The Thrombus Group kept the same OAC strategy with a NOAC in 6 cases (30%) and changed the strategy in 14 patients (70%), titrating NOAC dose in 1 (5%) and the VKA dose in 4 (20%) and switching from NOAC to VKA in 5 (25%), from VKA to NOAC in 3 (15%), and from NOAC to NOAC in 1 (5%). Smoke resolution was observed in 4/40 cases (10%) of the smoke group and thrombus resolution in 8/15 (53%) of the thrombus group. Patients with thrombus resolution had a lower CHA2DS2-Vasc score (3.5 ± 2 vs 4 ± 1, p = 0.05), were more often under NOAC (37.5 vs 28%, p = 0.07), and had a longer anticoagulation time (7.5 vs 4 months, p = 0.08). CONCLUSION (S): Changing OAC strategy is associated with thrombus resolution in more than 50% of chronically anticoagulated patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Trombose , Anticoagulantes , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Fumaça , Trombose/complicações , Trombose/diagnóstico por imagem , Trombose/prevenção & controle
20.
Artigo em Inglês | MEDLINE | ID: mdl-35037145

RESUMO

PURPOSE: We evaluated the clinical impact of the high-density (HD) mapping compared with the standard low-density (LD) ablation catheter mapping technique in the treatment of AFLs. METHODS: We retrospectively evaluated short and long outcomes of patients approached with an HD and a LD electro-anatomical strategy for atypical AFLs. RESULTS: Eighty-seven patients were included. Patients were almost male (60%), relatively old (65 ± 8 years), with a moderate CHA2DS2Vasc score (2.3 ± 1.3), a preserved ejection fraction (58 ± 6), and moderate atrial dilatation (44 ± 7 mm). Baseline clinical characteristics were comparable between groups (p = NS). Among AFLs, 10 (11%) were located in the right and 78 (89%) in the left atrium, including 22 (28%) roof dependent and 37 (47%) mitral dependent (p = NS). Sinus rhythm restoration during ablation was more frequently observed in the HD group (79% vs 56%, p = 0.037), without differences in mapping time, procedural time, and radiological dose (p = NS). Overall AFL/AT/AF recurrence rate at 1, 2, and 3 years was lower in the HD group (14% vs 37% p = 0.02, 14% vs 48% p = 0.002 and 14% vs 50% p < 0.001, respectively) with a time-dependent trend only in the LD group (37% vs 48% vs 50% at 1, 2, and 3 years respectively, p = 0.059). HD mapping (OR 0.17; 95% CI 0.04-0.66) and younger age (OR 1.09; 95% CI 1.01-1.19) resulted independent predictors of overall arrhythmias at follow-up. CONCLUSIONS: Short- and long-term outcomes of atypical AFL ablation were better in the case of HD mapping, which resulted independent predictor of arrhythmia recurrences.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA