Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Thorac Cardiovasc Surg ; 63(8): 675-83, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26366889

RESUMO

BACKGROUND: There is a paucity of data on the use of induction immunosuppression in patients with active infections undergoing orthotopic heart transplantation (OHT). We hypothesized that induction immunosuppression in patients with ventricular assist device (VAD) undergoing OHT with localized active driveline infection (DLI) does not lead to worse outcomes. MATERIALS AND METHODS: We retrospectively analyzed our database for bridge-to-transplant VAD patients who underwent OHT and received induction therapy. Patients were stratified into those with and without active DLI at the time of OHT and followed up till death or at least 30 months after OHT. Posttransplant length of stay (LOS), frequency of infections, and mortality were compared between the two groups. RESULTS: Thirty-eight patients (30 males) with mean age of 57.5 ± 13 years with VAD underwent OHT during the study period. Twelve had active DLI. Mean follow-up was 46.4 ± 23.1 months. In the DLI versus non-DLI group, there was no difference in mortality (17 vs. 23%, p = NS), LOS (16.3 ± 5.4 vs. 17.2 ± 13.7, p = NS), postoperative renal function, incidence of hyperacute or late rejection or infection either in the first month (25 vs. 23%, p = NS) or during entire follow-up (92 vs. 88%, p = NS). No patient in the DLI group had infections attributable to the same organism responsible for pretransplant DLI. CONCLUSION: In patients with active DLI, induction immunosuppression after OHT did not increase LOS, infections, or mortality after at least 30 months of follow-up and therefore it appears to be a safe and feasible therapeutic option.


Assuntos
Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Imunossupressores/uso terapêutico , Infecções Relacionadas à Prótese/microbiologia , Adulto , Idoso , Bases de Dados Factuais , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração/efeitos adversos , Transplante de Coração/mortalidade , Humanos , Hospedeiro Imunocomprometido , Imunossupressores/efeitos adversos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/imunologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA