Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
FASEB J ; 35(12): e22038, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34748229

RESUMO

Abdominal trauma (AT) is of major global importance, particularly with the increased potential for civil, terroristic, and military trauma. The injury pattern and systemic consequences of blunt abdominal injuries are highly variable and frequently underestimated or even missed, and the pathomechanisms remain still poorly understood. Therefore, we investigated the temporal-spatial organ and immune response after a standardized blast-induced blunt AT. Anesthetized mice were exposed to a single blast wave centered on the epigastrium. At 2, 6, or 24 h after trauma, abdominal organ damage was assessed macroscopically, microscopically, and biochemically. A higher degree of trauma severity, determined by a reduction of the distance between the epigastrium and blast inductor, was reflected by a reduced survival rate. The hemodynamic monitoring during the first 120 min after AT revealed a decline in the mean arterial pressure within the first 80 min, whereas the heart rate remained quite stable. AT induced a systemic damage and inflammatory response, evidenced by elevated HMGB-1 and IL-6 plasma levels. The macroscopic injury pattern of the abdominal organs (while complex) was consistent, with the following frequency: liver > pancreas > spleen > left kidney > intestine > right kidney > others > lungs and was reflected by microscopic liver and pancreas damages. Plasma levels of organ dysfunction markers increased during the first 6 h after AT and subsequently declined, indicating an early, temporal impairment of the function on a multi-organ level. The established highly reproducible murine blunt AT, with time- and trauma-severity-dependent organ injury patterns, systemic inflammatory response, and impairment of various organ functions, reflects characteristics of human AT. In the future, this model may help to study the complex immuno-pathophysiological consequences and innovative therapeutic approaches after blunt AT.


Assuntos
Traumatismos Abdominais/complicações , Injúria Renal Aguda/patologia , Traumatismos por Explosões/complicações , Fígado/patologia , Traumatismo Múltiplo/complicações , Pâncreas/patologia , Injúria Renal Aguda/etiologia , Animais , Fígado/lesões , Fígado/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pâncreas/lesões , Pâncreas/metabolismo
2.
Spine J ; 24(2): 340-351, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37660895

RESUMO

BACKGROUND CONTEXT: In contrast to cervical discectomy and fusion, total disc replacement (TDR) aims at preserving the motion at the treated vertebral level. Spinal motion is commonly evaluated with the range of motion (ROM). However, more qualitative information about cervical kinematics before and after TDR is still lacking. PURPOSE: The aim of this in vitro study was to investigate the influence of cervical TDR on ROM, instantaneous centers of rotation (ICR) and three-dimensional helical axes. STUDY DESIGN: An in vitro study with human spine specimens under pure moment loading was conducted to evaluate the kinematics of the intact cervical spine and compare it to cervical TDR. METHODS: Six fresh frozen human cervical specimens (C4-5, median age 28 years, range 19-47 years, two female and four male) were biomechanically characterized in the intact state and after implantation of a cervical disc prosthesis (MOVE-C, NGMedical, Germany). To mimic in vivo conditions regarding temperature and humidity, water steam was used to create a warm and humid test environment with 37°C. Each specimen was quasistatically loaded with pure moments up to ±2.5 Nm in flexion/extension (FE), lateral bending (LB) and axial rotation (AR) in a universal spine tester for 3.5 cycles at 1 °/s. For each third cycle of motion the ROM was evaluated and an established method was used to determine the helical axis and COR and to project them into three planar X-rays. Statistical analysis was conducted using a Friedman-test and post hoc correction with Dunn-Bonferroni-tests (p<.05). RESULTS: After TDR, total ROM was increased in FE from 19.1° to 20.1°, decreased in LB from 14.6° to 12.6° and decreased in AR from 17.7° to 15.5°. No statistical differences between the primary ROM in the intact condition and ROM after TDR were detected. Coupled rotation between LB and AR were also maintained. The position and orientation of the helical axes after cervical TDR was in good agreement with the results of the intact specimens in all three motion directions. The ICR in FE and AR before and after TDR closely matched, while in LB the ICR after TDR were more caudal. The intact in vitro kinematics we found also resembled in vivo results of healthy individuals. CONCLUSION: The results of this in vitro study highlight the potential of artificial cervical disc implants to replicate the quantity as well as the quality of motion of the intact cervical spine. CLINICAL SIGNIFICANCE: Physiological motion preservation was a driving factor in the development of cervical TDR. Our results demonstrate the potential of cervical TDR to replicate in vivo kinematics in all three motion directions.


Assuntos
Membros Artificiais , Substituição Total de Disco , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Implantação de Prótese/métodos , Discotomia/métodos , Substituição Total de Disco/métodos , Vértebras Cervicais/cirurgia , Vértebras Cervicais/fisiologia , Amplitude de Movimento Articular/fisiologia , Cadáver
3.
Spine J ; 24(7): 1313-1322, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38301903

RESUMO

BACKGROUND CONTEXT: The motion limitation after cervical discectomy and fusion alters the spine´s kinematics. Unphysiological strains may be the result and possible explanation for adjacent segment degeneration. Alterations to cervical kinematics due to cervical total disc replacement (TDR), especially two-level, are still under investigated. PURPOSE: To investigate cervical motion including coupled motions after one-level and two-level TDR in the treated and also the adjacent segments. STUDY DESIGN: An in-vitro study using pure moment loading of human donor spines. METHODS: Seven fresh frozen human cervical spine specimens (C4-T1, median age 46 with range 19-60 years, four female) were included in this study. Specimens were tested in the intact condition first, followed by one-level TDR at C5-6 which was subsequently extended one level further caudal (C5-7). Each specimen was quasistatically loaded with pure moments up to 1.5 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) in a universal spine tester for 3.5 cycles at 1 °/s. During the tests three dimensional motion tracking was performed for each vertebral body individually. From that, the primary and coupled ROM of each spinal level during the third full cycle of motion were evaluated. Nonparametric statistical analysis was performed using a Friedman-test and post hoc correction with Dunn-Bonferroni-tests (p<.05). Ethics approval was obtained in advance. RESULTS: In FE, one-level TDR (C5-6) moderately increased primary FE in all four segments, but only significantly at the cranial adjacent level C4-5. Additional TDR at C6-7 further increased the ROM at the target segment without much influence on the other levels. Increasing implant height at C6-7 partially counteracted the increased FE. Coupled motions were minimal in all test conditions at all levels. In LB, coupled AR was observed in all test conditions at all levels. One-level TDR decreased primary LB at the target segment C5-6 significantly, without much influence on the other levels. Extending TDR to C6-7 decreased ROM in the target segment but without gaining statistical significance. Increasing implant height at C6-7 further decreased primary LB at the target segment, still without significance. Notably, coupled AR was significantly decreased at the cranial adjacent segment C4-5 compared to the intact condition. In AR, coupled LB was observed in all test conditions at the levels C4-5, C5-6, and C6-7, while the transition level to the thoracic spine C7-T1 showed only little coupled LB. Both one-level and two-level TDR showed little influence on primary AR or coupled motions at any level. Only after increasing implant height at C6-7 was the motion of the caudally adjacent level C7-T1 significantly altered. CONCLUSION: Evaluating primary FE, LB, and AR together with the associated coupled motions revealed widespread influence of cervical TDR not only on the motion of the treated level but also at the adjacent segments. The influence of two-level TDR is more widespread and involves more levels than one-level TDR. CLINICAL SIGNIFICANCE: The prevention of unphysiological strains due to altered kinematics after cervical fusion, which could possibly explain adjacent segment degeneration, were a driving factor in the development of TDR. These experimental findings suggest cervical TDR influences the whole cervical spine, not only the treated segment. The effect becomes more extensive, involving more levels and motion directions, after two-level than after one-level TDR.


Assuntos
Vértebras Cervicais , Amplitude de Movimento Articular , Substituição Total de Disco , Humanos , Vértebras Cervicais/cirurgia , Substituição Total de Disco/métodos , Feminino , Amplitude de Movimento Articular/fisiologia , Pessoa de Meia-Idade , Adulto , Masculino , Fenômenos Biomecânicos/fisiologia , Adulto Jovem
4.
Clin Biomech (Bristol, Avon) ; 78: 105070, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32531440

RESUMO

BACKGROUND: Expandable titanium implants have proven their suitability as vertebral body replacement device in several clinical and biomechanical studies. Potential stabilizing features of personalized 3D printed titanium devices, however, have never been explored. This in vitro study aimed to prove their equivalence regarding primary stability and three-dimensional motion behavior in the mid-thoracic spine including the entire rib cage. METHODS: Six fresh frozen human thoracic spine specimens with intact rib cages were loaded with pure moments of 5 Nm while performing optical motion tracking of all vertebrae. Following testing in intact condition (1), the specimens were tested after inserting personalized 3D printed titanium vertebral body replacement implants (2) and the two standard expandable titanium implants Obelisc™ (3) and Synex™ (4), each at T6 level combined with posterior pedicle screw-rod fixation from T4 to T8. FINDINGS: No significant differences (P < .05) in primary and secondary T1-T12 ranges of motion were found between the three implant types. Compared to the intact condition, slight decreases of the range of motion were found, which were significant for Synex™ in primary flexion/extension (-17%), specifically at T3-T4 level (-46%), primary lateral bending (-18%), and secondary lateral bending during primary axial rotation (-53%). Range of motion solely increased at T8-T9 level, while being significant only for Obelisc™ (+35%). INTERPRETATION: Personalized 3D printed vertebral body replacement implants provide a promising alternative to standard expandable devices regarding primary stability and three-dimensional motion behavior in the mid-thoracic spine due to the stabilizing effect of the rib cage.


Assuntos
Fenômenos Mecânicos , Impressão Tridimensional , Caixa Torácica/cirurgia , Fusão Vertebral/instrumentação , Vértebras Torácicas/cirurgia , Titânio , Corpo Vertebral/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Padrões de Referência , Rotação , Fusão Vertebral/normas
5.
Artigo em Inglês | MEDLINE | ID: mdl-32582680

RESUMO

Spinal tumors and unstable vertebral body fractures usually require surgical treatment including vertebral body replacement. Regarding primary stability, however, the best possible treatment depends on the spinal region. The purpose of this in vitro study was to evaluate the effects of instrumentation length and approach size on thoracic spinal stability including the entire rib cage. Six fresh frozen human thoracic spine specimens with intact rib cages (C7-L1) were loaded with pure moments of 5 Nm in flexion/extension, lateral bending, and axial rotation, while monitoring the relative motions of all spinal segments using optical motion tracking. The specimens were tested (1) in the intact condition, followed by testing after vertebral body replacement at T6 level using a unilateral approach combined with (2) long instrumentation (T4-T8) and (3) short instrumentation (T5-T7) as well as a bilateral approach combined with (4) long and (5) short instrumentation. Significant increases of the range of motion (p < 0.05) were found in the entire thoracic spine (T1-T12) using the bilateral approach and short instrumentation in primary flexion/extension and in secondary axial rotation during primary lateral bending compared to both conditions with long instrumentation, as well as in secondary lateral bending during primary axial rotation compared to unilateral approach and long instrumentation. Compared to the intact condition, the range of motion was significantly decreased using unilateral approach and long instrumentation in flexion extension and secondary lateral bending during primary axial rotation, as well as using bilateral approach and long instrumentation in lateral bending. On the segmental level, the range of motion was significantly increased at T4-T5 level in lateral bending using unilateral approach and short instrumentation and significantly decreased using bilateral approach and long instrumentation compared to their respective previous conditions. Regardless of the approach type, which did not affect thoracic spinal stability in the present study, short instrumentation overall shows sufficient primary stability in the mid-thoracic spine with intact rib cage, while creating considerably more instability compared to long instrumentation, potentially being of importance regarding long-term implant failure. Moreover, short instrumentation could affect adjacent segment disease due to increased motion at the upper segmental level.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA