Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 383(9): 836-845, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32846062

RESUMO

BACKGROUND: A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes. METHODS: In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. RESULTS: A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS: In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Bombas de Infusão Implantáveis , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Cetoacidose Diabética/etiologia , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pâncreas Artificial
2.
Clin J Sport Med ; 33(5): 512-520, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36715983

RESUMO

OBJECTIVE: Pilot-test personalized digital health information to substantiate human-delivered exercise support for adults with type 1 diabetes (T1D). DESIGN: Single-group, 2-week baseline observation, then 10-week intervention with follow-up observation. SETTING: Community-based sample participating remotely with physician oversight. PARTICIPANTS: Volunteers aged 18 to 65 years with T1D screened for medical readiness for exercise intervention offerings. N = 20 enrolled, and N = 17 completed all outcomes with 88% to 91% biosensor adherence. INTERVENTION: Feedback on personalized data from continuous glucose monitoring (CGM), its intersection with other ecological data sets (exercise, mood, and sleep), and other informational and motivational elements (exercise videos, text-based exercise coach, and self-monitoring diary). MAIN OUTCOME MEASURES: Feasibility (use metrics and assessment completion), safety (mild and severe hypoglycemia, and diabetic ketoacidosis), acceptability (system usability scale, single items, and interview themes), and standard clinical and psychosocial assessments. RESULTS: Participants increased exercise from a median of 0 (Interquartile range, 0-21) to 64 (20-129) minutes per week ( P = 0.001, d = 0.71) with no severe hypoglycemia or ketoacidosis. Body mass index increased (29.5 ± 5.1 to 29.8 ± 5.4 kg/m 2 , P = 0.02, d = 0.57). Highest satisfaction ratings were for CGM use (89%) and data on exercise and its intersection with CGM and sleep (94%). Satisfaction was primarily because of improved exercise management behavioral skills, although derived motivation was transient. CONCLUSIONS: The intervention was feasible, safe, and acceptable. However, there is a need for more intensive, sustained support. Future interventions should perform analytics upon the digital health information and molecular biomarkers (eg, genomics) to make exercise support tools that are more personalized, automated, and intensive than our present offerings.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/psicologia , Glicemia , Automonitorização da Glicemia , Exercício Físico
3.
Clin Diabetes ; 41(3): 399-410, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37456102

RESUMO

Severe hypoglycemia (SH) is the most frequent and potentially serious complication affecting individuals with type 1 diabetes and can have major clinical and psychosocial consequences. Glucagon is the only approved treatment for SH that can be administered by non-health care professionals (HCPs); however, reports on the experiences and emotions of people with type 1 diabetes associated with SH and glucagon rescue use are limited. This survey study demonstrated that an increasing number of individuals with type 1 diabetes have current and filled prescriptions for glucagon and have been educated about glucagon rescue use by an HCP. Despite this positive trend, challenges with SH remain, including a high level of health care resource utilization, considerable out-of-pocket expenses for glucagon kits, a high prevalence of hypoglycemia unawareness, and a negative emotional impact on individuals with diabetes. Nocturnal and exercise-related hypoglycemia were concerns for most survey participants.

4.
Lancet ; 397(10270): 208-219, 2021 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-33453783

RESUMO

BACKGROUND: Management of type 1 diabetes is challenging. We compared outcomes using a commercially available hybrid closed-loop system versus a new investigational system with features potentially useful for adolescents and young adults with type 1 diabetes. METHODS: In this multinational, randomised, crossover trial (Fuzzy Logic Automated Insulin Regulation [FLAIR]), individuals aged 14-29 years old, with a clinical diagnosis of type 1 diabetes with a duration of at least 1 year, using either an insulin pump or multiple daily insulin injections, and glycated haemoglobin (HbA1c) levels of 7·0-11·0% (53-97 mmol/mol) were recruited from seven academic-based endocrinology practices, four in the USA, and one each in Germany, Israel, and Slovenia. After a run-in period to teach participants how to use the study pump and continuous glucose monitor, participants were randomly assigned (1:1) using a computer-generated sequence, with a permuted block design (block sizes of two and four), stratified by baseline HbA1c and use of a personal MiniMed 670G system (Medtronic) at enrolment, to either use of a MiniMed 670G hybrid closed-loop system (670G) or the investigational advanced hybrid closed-loop system (Medtronic) for the first 12-week period, and then participants were crossed over with no washout period, to the other group for use for another 12 weeks. Masking was not possible due to the nature of the systems used. The coprimary outcomes, measured with continuous glucose monitoring, were proportion of time that glucose levels were above 180 mg/dL (>10·0 mmol/L) during 0600 h to 2359 h (ie, daytime), tested for superiority, and proportion of time that glucose levels were below 54 mg/dL (<3·0 mmol/L) calculated over a full 24-h period, tested for non-inferiority (non-inferiority margin 2%). Analysis was by intention to treat. Safety was assessed in all participants randomly assigned to treatment. This trial is registered with ClinicalTrials.gov, NCT03040414, and is now complete. FINDINGS: Between June 3 and Aug 22, 2019, 113 individuals were enrolled into the trial. Mean age was 19 years (SD 4) and 70 (62%) of 113 participants were female. Mean proportion of time with daytime glucose levels above 180 mg/dL (>10·0 mmol/L) was 42% (SD 13) at baseline, 37% (9) during use of the 670G system, and 34% (9) during use of the advanced hybrid closed-loop system (mean difference [advanced hybrid closed-loop system minus 670G system] -3·00% [95% CI -3·97 to -2·04]; p<0·0001). Mean 24-h proportion of time with glucose levels below 54 mg/dL (<3·0 mmol/L) was 0·46% (SD 0·42) at baseline, 0·50% (0·35) during use of the 670G system, and 0·46% (0·33) during use of the advanced hybrid closed-loop system (mean difference [advanced hybrid closed-loop system minus 670G system] -0·06% [95% CI -0·11 to -0·02]; p<0·0001 for non-inferiority). One severe hypoglycaemic event occurred in the advanced hybrid closed-loop system group, determined to be unrelated to study treatment, and none occurred in the 670G group. INTERPRETATION: Hyperglycaemia was reduced without increasing hypoglycaemia in adolescents and young adults with type 1 diabetes using the investigational advanced hybrid closed-loop system compared with the commercially available MiniMed 670G system. Testing an advanced hybrid closed-loop system in populations that are underserved due to socioeconomic factors and testing during pregnancy and in individuals with impaired awareness of hypoglycaemia would advance the effective use of this technology FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Adulto , Feminino , Alemanha , Humanos , Hiperglicemia/prevenção & controle , Israel , Masculino , Estados Unidos , Adulto Jovem
5.
PLoS Comput Biol ; 17(8): e1009303, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34424894

RESUMO

The development of mobile-health technology has the potential to revolutionize personalized medicine. Biomedical sensors (e.g., wearables) can assist with determining treatment plans for individuals, provide quantitative information to healthcare providers, and give objective measurements of health, leading to the goal of precise phenotypic correlates for genotypes. Even though treatments and interventions are becoming more specific and datasets more abundant, measuring the causal impact of health interventions requires careful considerations of complex covariate structures, as well as knowledge of the temporal and spatial properties of the data. Thus, interpreting biomedical sensor data needs to make use of specialized statistical models. Here, we show how the Bayesian structural time series framework, widely used in economics, can be applied to these data. This framework corrects for covariates to provide accurate assessments of the significance of interventions. Furthermore, it allows for a time-dependent confidence interval of impact, which is useful for considering individualized assessments of intervention efficacy. We provide a customized biomedical adaptor tool, MhealthCI, around a specific implementation of the Bayesian structural time series framework that uniformly processes, prepares, and registers diverse biomedical data. We apply the software implementation of MhealthCI to a structured set of examples in biomedicine to showcase the ability of the framework to evaluate interventions with varying levels of data richness and covariate complexity and also compare the performance to other models. Specifically, we show how the framework is able to evaluate an exercise intervention's effect on stabilizing blood glucose in a diabetes dataset. We also provide a future-anticipating illustration from a behavioral dataset showcasing how the framework integrates complex spatial covariates. Overall, we show the robustness of the Bayesian structural time series framework when applied to biomedical sensor data, highlighting its increasing value for current and future datasets.


Assuntos
Teorema de Bayes , Modelos Estatísticos , Técnicas Biossensoriais , Conjuntos de Dados como Assunto , Humanos , Software
6.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35837984

RESUMO

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Insulina/uso terapêutico , Qualidade de Vida , Hipoglicemiantes/uso terapêutico , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Pais/psicologia
7.
Diabet Med ; 38(10): e14492, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33290599

RESUMO

AIMS: Participant-driven solutions may help youth and families better engage and maintain use of diabetes technologies. We explored innovative features and functionalities of an ideal artificial pancreas (AP) system suggested by youth with type 1 diabetes and parents. METHODS: Semi-structured interviews were conducted with 39 youth, ages 10-25 years, and 44 parents. Interviews were recorded, transcribed and coded using thematic analysis. RESULTS: Youth (72% female, 82% non-Hispanic white) were (M ± SD) ages 17.0 ± 4.7 years, with diabetes for 9.4 ± 4.9 years, and HbA1c of 68 ± 11 mmol/mol (8.4 ± 1.1%); 79% were pump-treated and 82% were continuous glucose monitor users. Of parents, 91% were mothers and 86% were non-Hispanic white, with a child 10.6 ± 4.5 years old. Youth and parents suggested a variety of innovative features and functionalities for an ideal AP system related to (1) enhancing the appeal of user interface, (2) increasing automation of new glucose management functionalities, and (3) innovative and commercial add-ons for greater convenience. Youth and parents offered many similar suggestions, including integration of ketone testing, voice activation, and location-tracking into the system. Youth seemed more driven by increasing convenience and normalcy while parents expressed more concerns with safety. CONCLUSIONS: Youth and parents expressed creative solutions for an ideal AP system to increase ease of use, enhance normalcy, and reduce burden of management. Designers of AP systems will likely benefit from incorporating the desired preferences by end users to optimize acceptance and usability by young persons with diabetes.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Desenho de Equipamento/psicologia , Sistemas de Infusão de Insulina/psicologia , Insulina/administração & dosagem , Pâncreas Artificial/psicologia , Pais/psicologia , Adolescente , Adulto , Fatores Etários , Criança , Feminino , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Preferência do Paciente , Adulto Jovem
8.
Pediatr Diabetes ; 22(7): 1063-1070, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34324772

RESUMO

BACKGROUND: As new diabetes technologies improve to better manage glucose levels, users' priorities for future technologies may shift to prioritize burden reduction and ease of use. We used qualitative methods to explore youth and parent desired features of an "ideal" artificial pancreas (AP) system. METHODS: We conducted semi-structured interviews with 39 youth, ages 10-25 years, and 44 parents. Interviews were audio-recorded, transcribed, and coded using thematic analysis. RESULTS: Youth (79% female, 82% non-Hispanic white) were (M ± SD) ages 17.0 ± 4.7 years, with diabetes for 9.4 ± 4.9 years, and HbA1c of 8.4 ± 1.1%; 79% were pump-treated and 82% used CGM. Of parents, 91% were mothers and 86% were non-Hispanic white. Participants suggested various ways in which an ideal AP system could reduce physical and emotional burdens of diabetes. Physical burdens could be reduced by lessening user responsibilities to manage glucose for food and exercise, and wear or carry devices. Emotional burden could be reduced by mitigating negative emotional reactions to sound and frequency of alerts, while increasing feelings of normalcy. Youth and parents differed in their suggestions to reduce emotional burden. Participants suggested features that would improve glycemia, but nearly always in the context of how the feature would directly reduce their diabetes-specific burden. CONCLUSIONS: Although participants expressed interest in improving glucose levels, the pervasive desire among suggested features of an ideal AP system was to minimize the burden of diabetes. Understanding and addressing users' priorities to reduce physical and emotional burden will be necessary to enhance uptake and maintain use of future AP systems.


Assuntos
Efeitos Psicossociais da Doença , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Pâncreas Artificial , Pais , Preferência do Paciente/psicologia , Adolescente , Criança , Emoções , Feminino , Hemoglobinas Glicadas/análise , Controle Glicêmico , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Preferência do Paciente/estatística & dados numéricos , Qualidade de Vida , Adulto Jovem
9.
Pediatr Diabetes ; 20(4): 450-459, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30834621

RESUMO

BACKGROUND/OBJECTIVE: Many adolescents with type 1 diabetes do not achieve 60 minutes of daily moderate-to-vigorous intensity physical activity (MVPA). Recognizing the importance of peer influence during adolescence, we evaluated the feasibility and safety of a group MVPA intervention for this population. METHODS: Eighteen adolescents with type 1 diabetes (age 14.1 ± 2 .3 years, female 67%, black or Latino 67%, median body mass index 92%'ile, A1c 79.9 ± 25.1 mmol/mol, 9.5 ± 2.3%). Intervention sessions (35 minutes MVPA and 45 minutes discussion) occurred 1×/week for 12 weeks. Feasibility and safety metrics were enrollment, completion of intervention and assessments, cost, and hypoglycemia rates. Participants completed MVPA (accelerometry), and exploratory nutritional, psychosocial, clinical, and fitness variable assessments at baseline, 3 months, and 7 months. Hedges' effect sizes were calculated. RESULTS: Enrollment was 16%, and intervention completion was 56%. Assessment completion at 7 months was 67% for MVPA, nutrition, and fitness, 83% for psychosocial assessments, and 94% for clinical assessments. Cost was $1241 per completing participant. One episode of mild hypoglycemia occurred during the sessions (0.6%). Self-reported daily fruit/vegetable servings (d = -0.72) and diabetes self-management behaviors decreased over time (d = -0.40). In the 10 completers, endurance run score improved (d = 0.49) from low baseline levels, while systolic blood pressure decreased (d = -0.75) and low-density lipoprotein increased (d = 0.49) but stayed within normal ranges. CONCLUSIONS: The protocol for the group MVPA intervention was safe and had some feasibility metrics meriting further investigation. MVPA levels and glycemic control remained suboptimal, suggesting the need for more intensive interventions for this population.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Terapia por Exercício/efeitos adversos , Terapia por Exercício/métodos , Exercício Físico/fisiologia , Processos Grupais , Acelerometria , Adolescente , Fatores Etários , Glicemia/análise , Glicemia/metabolismo , Criança , Terapia Combinada , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , Registros de Dieta , Estudos de Viabilidade , Feminino , Comportamentos Relacionados com a Saúde , Humanos , Masculino , Adulto Jovem
10.
Pediatr Diabetes ; 19(1): 92-97, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28303678

RESUMO

BACKGROUND: Despite significant advances in type 1 diabetes (T1D) management, achieving targeted glycemic control in pediatric patients remains a struggle. Continuous glucose monitoring (CGM) with remote access holds the promise to address this challenge by allowing caregivers to monitor glucose, even when the child is not directly under their supervision. OBJECTIVE: To explore real-time and remote CGM practices in homes and schools, including caregiver expectations regarding this technology. SUBJECTS: Parents and daytime caregivers. METHODS: Respondents answered an anonymous survey assessing characteristics of CGM use. Cross-sectional data were collected and analyzed using quantitative and qualitative methods. RESULTS: Thirty-three parents and 17 daytime caregivers responded. Threshold alerts (alerts when patients reached certain pre-set high or low limits) were used most frequently, followed by rate of change alerts. Most parents and daytime caregivers responded to low- and high-threshold CGM alerts by confirming with a glucose meter prior to treatment; while about one-third endorsed treating lows without a confirmatory test. Most parents expected their child's daytime caregiver to respond to CGM alerts and daytime caregivers felt the parent's expectations of them were reasonable. All parents and most caregivers reported decreased overall worry/stress. Parents felt positive about CGM use and daytime caregivers felt comfortable with CGM. CONCLUSION: The positive and collaborative management reported by parents and daytime caregivers sets the stage for CGM to play an important role in the management of children with T1D both in the home and in the school settings.


Assuntos
Glicemia , Cuidadores/psicologia , Alarmes Clínicos/estatística & dados numéricos , Diabetes Mellitus Tipo 1 , Monitorização Ambulatorial/psicologia , Adolescente , Adulto , Cuidadores/estatística & dados numéricos , Criança , Pré-Escolar , Gerenciamento Clínico , Humanos , Monitorização Ambulatorial/estatística & dados numéricos , Pais/psicologia , Serviços de Saúde Escolar , Inquéritos e Questionários
11.
Pediatr Diabetes ; 2018 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-29675980

RESUMO

The extant literature finds that children with type 1 diabetes mellitus (T1D) experience mild cognitive alterations compared to healthy age-matched controls. The neural basis of these cognitive differences is unclear but may relate in part to the effects of dysglycemia on the developing brain. We investigated longitudinal changes in hippocampus volume in young children with early-onset T1D. Structural magnetic resonance imaging data were acquired from 142 children with T1D and 65 age-matched control subjects (4-10 years of age at study entry) at 2 time points, 18 months apart. The effects of diabetes and glycemic exposure on hippocampal volume and growth were examined. Results indicated that although longitudinal hippocampus growth did not differ between children with T1D and healthy control children, slower growth of the hippocampus was associated with both increased exposure to hyperglycemia (interval HbA1c) and greater glycemic variability (MAGE) in T1D. These observations indicate that the current practice of tolerating some hyperglycemia to minimize the risk of hypoglycemia in young children with T1D may not be optimal for the developing brain. Efforts that continue to assess the factors influencing neural and cognitive development in children with T1D will be critical in minimizing the deleterious effects of diabetes.

12.
Pediatr Diabetes ; 18(5): 348-355, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27191182

RESUMO

BACKGROUND: Automated insulin delivery systems, utilizing a control algorithm to dose insulin based upon subcutaneous continuous glucose sensor values and insulin pump therapy, will soon be available for commercial use. The objective of this study was to determine the preliminary safety and efficacy of initialization parameters with the Medtronic hybrid closed-loop controller by comparing percentage of time in range, 70-180 mg/dL (3.9-10 mmol/L), mean glucose values, as well as percentage of time above and below target range between sensor-augmented pump therapy and hybrid closed-loop, in adults and adolescents with type 1 diabetes. METHODS: We studied an initial cohort of 9 adults followed by a second cohort of 15 adolescents, using the Medtronic hybrid closed-loop system with the proportional-integral-derivative with insulin feed-back (PID-IFB) algorithm. Hybrid closed-loop was tested in supervised hotel-based studies over 4-5 days. RESULTS: The overall mean percentage of time in range (70-180 mg/dL, 3.9-10 mmol/L) during hybrid closed-loop was 71.8% in the adult cohort and 69.8% in the adolescent cohort. The overall percentage of time spent under 70 mg/dL (3.9 mmol/L) was 2.0% in the adult cohort and 2.5% in the adolescent cohort. Mean glucose values were 152 mg/dL (8.4 mmol/L) in the adult cohort and 153 mg/dL (8.5 mmol/L) in the adolescent cohort. CONCLUSIONS: Closed-loop control using the Medtronic hybrid closed-loop system enables adaptive, real-time basal rate modulation. Initializing hybrid closed-loop in clinical practice will involve individualizing initiation parameters to optimize overall glucose control.


Assuntos
Atividades Cotidianas , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose/metabolismo , Hiperglicemia/prevenção & controle , Pâncreas Artificial , Medicina de Precisão , Tela Subcutânea/efeitos dos fármacos , Adolescente , Comportamento do Adolescente , Adulto , Algoritmos , Glicemia/análise , Automonitorização da Glicemia , Calibragem , Estudos de Coortes , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/metabolismo , Cálculos da Dosagem de Medicamento , Monitoramento de Medicamentos , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Pâncreas Artificial/efeitos adversos , Tela Subcutânea/metabolismo , Adulto Jovem
13.
Hum Brain Mapp ; 37(11): 4034-4046, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27339089

RESUMO

Type 1 diabetes mellitus (T1D), one of the most frequent chronic diseases in children, is associated with glucose dysregulation that contributes to an increased risk for neurocognitive deficits. While there is a bulk of evidence regarding neurocognitive deficits in adults with T1D, little is known about how early-onset T1D affects neural networks in young children. Recent data demonstrated widespread alterations in regional gray matter and white matter associated with T1D in young children. These widespread neuroanatomical changes might impact the organization of large-scale brain networks. In the present study, we applied graph-theoretical analysis to test whether the organization of structural covariance networks in the brain for a cohort of young children with T1D (N = 141) is altered compared to healthy controls (HC; N = 69). While the networks in both groups followed a small world organization-an architecture that is simultaneously highly segregated and integrated-the T1D network showed significantly longer path length compared with HC, suggesting reduced global integration of brain networks in young children with T1D. In addition, network robustness analysis revealed that the T1D network model showed more vulnerability to neural insult compared with HC. These results suggest that early-onset T1D negatively impacts the global organization of structural covariance networks and influences the trajectory of brain development in childhood. This is the first study to examine structural covariance networks in young children with T1D. Improving glycemic control for young children with T1D might help prevent alterations in brain networks in this population. Hum Brain Mapp 37:4034-4046, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Encéfalo/diagnóstico por imagem , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Vias Neurais/diagnóstico por imagem
14.
Pediatr Diabetes ; 17(4): 237-43, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-25720763

RESUMO

OBJECTIVE: Prior studies examining beta-cell preservation in type 1 diabetes have predominantly assessed stimulated C-peptide concentrations approximately 10 wk after diagnosis. We examined whether earlier assessments might aid in prediction of beta cell function over time. METHODS: Using data from a multi-center randomized trial assessing the effect of intensive diabetes management initiated within 1 wk of diagnosis, we assessed which clinical factors predicted 90-min mixed-meal tolerance test (MMTT) stimulated C-peptide values obtained 2 and 6 wk after diagnosis. We also studied associations of these factors with C-peptide values at 1- and 2-year post-diagnosis. Data from intervention and control groups were pooled. RESULTS: Among 67 study participants (mean age 13.3 ± 5.7 yr, range 7.8-45.7 yr) in multivariable analyses, C-peptide increased from baseline to 2 wks and then 6 wk. C-peptide levels at these times were significantly correlated with 1- and 2-yr C-peptide concentrations (all p < 0.001), with the strongest observed associations between 6-wk C-peptide and the 1- and 2-yr values (r = 0.66 and r = 0.61, respectively). In multivariable analyses, greater baseline and 6-wk C-peptide, and older age independently predicted greater 1- and 2-yr C-peptide concentrations. CONCLUSIONS: C-peptide assessments close to diagnosis were predictive of subsequent C-peptide production. Our data demonstrate a clear increase in C-peptide over the initial 6 wk after diabetes diagnosis followed by a plateau. Our data do not suggest that MMTT assessments performed closer to diagnosis than 6 wk would improve prediction of subsequent residual beta cell function.


Assuntos
Peptídeo C/sangue , Diabetes Mellitus Tipo 1/sangue , Células Secretoras de Insulina/fisiologia , Adolescente , Adulto , Criança , Diabetes Mellitus Tipo 1/fisiopatologia , Humanos , Pessoa de Meia-Idade , Adulto Jovem
15.
Diabetologia ; 58(6): 1167-74, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25773405

RESUMO

AIMS/HYPOTHESIS: The aim of this work was to assess the association between continuous glucose monitoring (CGM) data, HbA1c, insulin-dose-adjusted HbA1c (IDAA1c) and C-peptide responses during the first 2 years following diagnosis of type 1 diabetes. METHODS: A secondary analysis was conducted of data collected from a randomised trial assessing the effect of intensive management initiated within 1 week of diagnosis of type 1 diabetes, in which mixed-meal tolerance tests were performed at baseline and at eight additional time points through 24 months. CGM data were collected at each visit. RESULTS: Among 67 study participants (mean age [± SD] 13.3 ± 5.7 years), HbA1c was inversely correlated with C-peptide at each time point (p < 0.001), as were changes in each measure between time points (p < 0.001). However, C-peptide at one visit did not predict the change in HbA1c at the next visit and vice versa. Higher C-peptide levels correlated with increased proportion of CGM glucose values between 3.9 and 7.8 mmol/l and lower CV (p = 0.001 and p = 0.02, respectively) but not with CGM glucose levels <3.9 mmol/l. Virtually all participants with IDAA1c < 9 retained substantial insulin secretion but when evaluated together with CGM, time in the range of 3.9-7.8 mmol/l and CV did not provide additional value in predicting C-peptide levels. CONCLUSIONS/INTERPRETATION: In the first 2 years after diagnosis of type 1 diabetes, higher C-peptide levels are associated with increased sensor glucose levels in the target range and with lower glucose variability but not hypoglycaemia. CGM metrics do not provide added value over the IDAA1c in predicting C-peptide levels.


Assuntos
Glicemia/análise , Peptídeo C/sangue , Diabetes Mellitus Tipo 1/sangue , Hemoglobinas Glicadas/metabolismo , Insulina/administração & dosagem , Adolescente , Adulto , Automonitorização da Glicemia , Criança , Teste de Tolerância a Glucose , Humanos , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
16.
Pediatr Radiol ; 44(2): 181-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24096802

RESUMO

BACKGROUND: The ability to lie still in an MRI scanner is essential for obtaining usable image data. To reduce motion, young children are often sedated, adding significant cost and risk. OBJECTIVE: We assessed the feasibility of using a simple and affordable behavioral desensitization program to yield high-quality brain MRI scans in sedation-free children. MATERIALS AND METHODS: 222 children (4-9.9 years), 147 with type 1 diabetes and 75 age-matched non-diabetic controls, participated in a multi-site study focused on effects of type 1 diabetes on the developing brain. T1-weighted and diffusion-weighted imaging (DWI) MRI scans were performed. All children underwent behavioral training and practice MRI sessions using either a commercial MRI simulator or an inexpensive mock scanner consisting of a toy tunnel, vibrating mat, and video player to simulate the sounds and feel of the MRI scanner. RESULTS: 205 children (92.3%), mean age 7 ± 1.7 years had high-quality T1-W scans and 174 (78.4%) had high-quality diffusion-weighted scans after the first scan session. With a second scan session, success rates were 100% and 92.5% for T1-and diffusion-weighted scans, respectively. Success rates did not differ between children with type 1 diabetes and children without diabetes, or between centers using a commercial MRI scan simulator and those using the inexpensive mock scanner. CONCLUSION: Behavioral training can lead to a high success rate for obtaining high-quality T1-and diffusion-weighted brain images from a young population without sedation.


Assuntos
Artefatos , Encéfalo/patologia , Dessensibilização Psicológica/métodos , Diabetes Mellitus Tipo 1/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/psicologia , Aumento da Imagem/métodos , Adolescente , Criança , Pré-Escolar , Sedação Consciente , Estudos de Viabilidade , Feminino , Humanos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
17.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494876

RESUMO

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

18.
Pediatr Diabetes ; 14(3): 168-73, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23107353

RESUMO

BACKGROUND AND OBJECTIVE: Subcutaneously injected rapid-acting insulin analogs do not replicate physiologic insulin action due to delays in their onset and peak action resulting in postprandial glucose excursions. The InsuPatch (IP) is a novel insulin infusion site warming device developed to accelerate insulin action by increasing blood flow to the area of insulin absorption. Thirteen adolescents with type 1 diabetes (T1D, mean age 14 ± 4 yr) were enrolled in this study to investigate the effect of the IP on the pharmacodynamics and pharmacokinetics of a 0.2 unit/kg bolus dose of aspart insulin using the euglycemic clamp technique. RESEARCH DESIGN AND METHODS: Each subject underwent two euglycemic clamp procedures on separate occasions: one with IP and one without IP activation in random order. RESULTS: When the insulin bolus was given with IP activation as compared to without IP activation, time to reach maximum insulin action (T(GIRmax)) and to reach 50% maximum action (T(50%GIRmax)) were 35 and 18 min earlier (125 ± 8 min vs. 90 ± 6 min, p = 0.002 and 58 ± 5 min. vs. 40 ± 3 min, p = 0.01, respectively), and the area under curve, AUC(GIR 0-90 min), reflecting early glucodynamic action, was significantly greater (p = 0.001). IP activation also accelerated the rise in plasma insulin levels after the bolus (p = 0.03) and resulted in a higher peak (p = 0.04) and greater overall increase (p = 0.02) in plasma insulin levels. CONCLUSIONS: Our results show that insulin infusion site warming with IP activation accelerates the time action profile of aspart insulin which may be of benefit to current open-loop and future closed-loop insulin delivery in patients with T1D.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina Aspart/administração & dosagem , Sistemas de Infusão de Insulina , Fluxo Sanguíneo Regional , Absorção , Adolescente , Glicemia/análise , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Feminino , Técnica Clamp de Glucose , Temperatura Alta , Humanos , Hipoglicemiantes/sangue , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/uso terapêutico , Infusões Subcutâneas , Insulina Aspart/sangue , Insulina Aspart/farmacocinética , Insulina Aspart/uso terapêutico , Masculino , Temperatura Cutânea
20.
Can J Diabetes ; 47(1): 66-72, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36184368

RESUMO

OBJECTIVES: Teens and young adults with type 1 diabetes (T1D) often demonstrate difficulty with diabetes management, as they struggle to navigate the impact of T1D on their identities---their self-concepts, bodies, social networks, life experiences and desired futures. Positively incorporating T1D into identity may benefit biomedical and psychosocial outcomes. We aimed to validate and assess psychometric properties of the Accepting Diabetes and Personal Treatment (ADAPT) survey, a new measure of incorporation of T1D into one's identity. METHODS: This cross-sectional study included 165 teens and young adults (13 to 25 years of age) with T1D (46% male, 87% Caucasian, 72% pump users, 67% on continuous glucose monitoring [CGM], age 18.5±3.2 years, diabetes duration 10.2±5.0 years, glycated hemoglobin [A1C] 8.5±1.3% [69±14 mmol/mol]). A1C was collected from medical records; participants completed the ADAPT survey and validated measures of fear of hypoglycemia, diabetes distress and quality of life. Internal consistency, reliability, validity and underlying factor structure were assessed. RESULTS: The 18-item ADAPT survey demonstrated excellent internal consistency (alpha=0.90) as well as criterion and construct validity. Greater incorporation of diabetes was associated with male sex, pump use, CGM use, lower A1C, less fear of hypoglycemia, less diabetes distress and improved quality of life (p<0.01 for all). Factor analysis identified 3 main contributors to incorporation: Stigma Management, Adjustment to Perceived Interference and Benefit-finding. CONCLUSIONS: The ADAPT survey is a valid and reliable measure of incorporation in teens and young adults with T1D that highlights the importance of identity in health outcomes. Diabetes device use and factors of incorporation (Stigma Management, Adjustment to Perceived Interference and Benefit-finding) offer targets for clinical intervention.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Autoimagem , Adolescente , Feminino , Humanos , Masculino , Adulto Jovem , Glicemia/metabolismo , Automonitorização da Glicemia/psicologia , Estudos Transversais , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/psicologia , Hemoglobinas Glicadas , Qualidade de Vida , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA