1.
J Shoulder Elbow Surg ; 33(7): 1465-1472, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38182025

RESUMO

BACKGROUND: Particle-induced osteolysis resulting from polyethylene wear remains a source of implant failure in anatomic total shoulder designs. Modern polyethylene components are irradiated in an oxygen-free environment to induce cross-linking, but reducing the resulting free radicals with melting or heat annealing can compromise the component's mechanical properties. Vitamin E has been introduced as an adjuvant to thermal treatments. Anatomic shoulder arthroplasty models with a ceramic head component have demonstrated that vitamin E-enhanced polyethylene show improved wear compared with highly cross-linked polyethylene (HXLPE). This study aimed to assess the biomechanical wear properties and particle size characteristics of a novel vitamin E-enhanced highly cross-linked polyethylene (VEXPE) glenoid compared to a conventional ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid against a cobalt chromium molybdenum (CoCrMo) head component. METHODS: Biomechanical wear testing was performed to compare the VEXPE glenoid to UHMWPE glenoid with regard to pristine polyethylene wear and abrasive endurance against a polished CoCrMo alloy humeral head in an anatomic shoulder wear-simulation model. Cumulative mass loss (milligrams) was recorded, and wear rate calculated (milligrams per megacycle [Mc]). Under pristine wear conditions, particle analysis was performed, and functional biologic activity (FBA) was calculated to estimate particle debris osteolytic potential. In addition, 95% confidence intervals for all testing conditions were calculated. RESULTS: The average pristine wear rate was statistically significantly lower for the VEXPE glenoid compared with the HXLPE glenoid (0.81 ± 0.64 mg/Mc vs. 7.00 ± 0.45 mg/Mc) (P < .05). Under abrasive wear conditions, the VEXPE glenoid had a statistically significant lower average wear rate compared with the UHMWPE glenoid comparator device (18.93 ± 5.80 mg/Mc vs. 40.47 ± 2.63 mg/Mc) (P < .05). The VEXPE glenoid demonstrated a statistically significant improvement in FBA compared with the HXLPE glenoid (0.21 ± 0.21 vs. 1.54 ± 0.49 (P < .05). CONCLUSIONS: A new anatomic glenoid component with VEXPE demonstrated significantly improved pristine and abrasive wear properties with lower osteolytic particle debris potential compared with a conventional UHMWPE glenoid component. Vitamin E-enhanced polyethylene shows early promise in shoulder arthroplasty components. Long-term clinical and radiographic investigation needs to be performed to verify if these biomechanical wear properties translate to diminished long-term wear, osteolysis, and loosening.


Assuntos
Artroplastia do Ombro , Teste de Materiais , Polietilenos , Desenho de Prótese , Falha de Prótese , Prótese de Ombro , Vitamina E , Humanos , Artroplastia do Ombro/métodos , Fenômenos Biomecânicos , Tamanho da Partícula , Osteólise/etiologia , Osteólise/prevenção & controle , Articulação do Ombro/cirurgia
2.
Arch Orthop Trauma Surg ; 144(5): 1925-1935, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38523239

RESUMO

BACKGROUND: Patients who undergo reverse total shoulder arthroplasty (RTSA) are getting younger with greater function expectations. This retrospective, longitudinal study of prospectively collected data compared perceived shoulder function and strength, active shoulder mobility, radiographic evidence of scapular notching, and implant survival over the initial 2-years post-RTSA among patient groups who received either standard central fixation point liner and glenoid baseplate implants, or lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants. MATERIALS AND METHODS: Patients who underwent primary RTSA using standard central fixation point liner and glenoid baseplate implants (Group 1, n = 180) were compared with patients who underwent primary RTSA using lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants (Group 2, n = 53) for active shoulder mobility, American Shoulder and Elbow Surgeons (ASES) score, perceived ability to lift 10 lbs (4.5 kg) overhead, radiographic evidence of scapular notching, and implant survival. Data was collected pre-surgery, 6-weeks, 6-months, 1-year, and 2-years post-RTSA (p ≤ 0.05). RESULTS: More Group 2 patients had more complex B or C Walch glenoid morphology, while Group 1 had more A1 or A2 types (p ≤ 0.001). Group 2 had greater active shoulder flexion at 6-months, 1-year, and 2-years (p ≤ 0.018) and external rotation (in adduction) at 6-months and 2-years (p ≤ 0.004) compared to Group 1, with higher ASES scores at 6-months and 2-years (p ≤ 0.026) (with small-to-medium effect sizes), and with more patients meeting or exceeding the minimal clinically important difference (MCID) at 2-years (p = 0.045) and patient acceptable symptomatic state (PASS) levels at 6-months, 1-year and 2-years (p ≤ 0.045). Scapular notching was identified in six of 53 (11.3%) Group 2 patients and in 32 of 180 (17.7%) Group 1 patients. Group 1 patients had more grade 2 or greater scapular notching grades compared to Group 2 (p = 0.04). Implant survival was comparable with Group 1 = eight of 180 (4.4%) and Group 2 = 1 of 53 (1.9%) of patients requiring removal for 95.6% and 98.1% implant survival, respectively. CONCLUSION: Limited scapular notching and excellent implant survival was observed in both groups. Despite including individuals with more complex glenoid deficiency, patients receiving the lower size profile implants generally displayed better active shoulder mobility and perceived shoulder function compared to those who received standard implants. These patients also more frequently met or exceeded the MCID by 2-years post-RTSA and PASS levels by 6-months, 1-year, and 2-years post-RTSA, with lower scapular notching grades. LEVEL OF EVIDENCE: Retrospective comparative study.


Assuntos
Artroplastia do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/instrumentação , Estudos Retrospectivos , Masculino , Idoso , Feminino , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Desenho de Prótese , Estudos Longitudinais , Úmero/cirurgia , Amplitude de Movimento Articular , Idoso de 80 Anos ou mais
3.
Eur J Orthop Surg Traumatol ; 34(2): 1045-1056, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37898968

RESUMO

BACKGROUND: Augmented glenoid baseplate and offset humeral tray reverse total shoulder arthroplasty (RTSA) implants may decrease the mechanical impingement that creates scapular notching and improve shoulder function. This study evaluated the clinical efficacy of three different RTSA glenoid baseplate and offset humeral tray combinations for patient-reported shoulder function, pain and instability, radiographic imaging evidence of glenoid baseplate or humeral stem subsidence and migration, bony changes associated with implant loosening, and scapular notching over the initial 2 years post-RTSA. Primary outcomes included active shoulder mobility, perceived function, pain, instability, scapular notching, and implant survival. METHODS: Sixty-seven patients from 6 research sites received one of three different glenoid baseplate and humeral tray combinations. Group 1 (n = 21) received a mini-augmented glenoid baseplate with a standard humeral tray; Group 2 (n = 23) received a standard glenoid baseplate and a mini-humeral tray with 3 trunnion offset options; Group 3 (n = 23) received both a mini-augmented glenoid baseplate and a mini-humeral tray with 3 trunnion offset options. Subjects underwent radiologic evaluation, completed the ASES scale, the EQ-5D-5L quality of life scale, VAS shoulder pain and instability questions, and active shoulder mobility measurements pre-operatively, and 6-weeks, 6-months, 1-2 years post-RTSA. RESULTS: Improved active shoulder mobility, quality of life, perceived function, decreased shoulder pain and instability, excellent implant survival and minimal scapular notching were observed for all groups. Group 3 had better overall active shoulder mobility than the other groups and better perceived function than Group 1. CONCLUSION: The group that received the mini-augmented glenoid baseplate and mini-humeral tray combination had better overall active shoulder flexion, external rotation at 90° abduction, and internal rotation. This group also had better perceived shoulder function compared to the group that received a mini-augmented glenoid baseplate with a standard humeral tray.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Prótese Articular , Articulação do Ombro , Prótese de Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Dor de Ombro/cirurgia , Qualidade de Vida , Úmero/cirurgia , Prótese Articular/efeitos adversos , Resultado do Tratamento , Amplitude de Movimento Articular , Estudos Retrospectivos , Cavidade Glenoide/cirurgia
4.
J Shoulder Elbow Surg ; 32(5): 1016-1021, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36565740

RESUMO

BACKGROUND: To assess the role of latissimus dorsi tendon transfer (LDT) concomitant with reverse total shoulder arthroplasty in patients with external rotation (ER) deficit secondary to severe rotator cuff deficiency with and without glenohumeral arthritis. METHODS: Patients with a positive external lag sign and <10° of active external rotation (aER) treated with reverse shoulder arthroplasty at a single institution with a minimum 12-month follow-up were retrospectively identified from a prospective database. Basic demographic information along with preoperative and postoperative range of motion (ROM) measures, American Shoulder and Elbow Surgeons score (ASES), Visual Analog Scale (VAS) pain, and Subjective Shoulder Value scores were obtained. Statistical analysis was performed to compare ROM and functional outcomes between patients who underwent concomitant LDT and those with no transfer (NT). RESULTS: The LDT (n = 31) and NT (n = 33) groups had similar age, sex distributions, and follow-up length average (24 vs. 30 months). No differences were found between groups at baseline, final follow-up, or magnitude of change for ASES, VAS pain, and Subjective Shoulder Value scores. Baseline ROM measures were similar, except for the LDT group having slightly less aER (-8° vs. 0°; P = .004). In addition, all postoperative ROM measures including aER were similar, except for a slight improvement in active internal rotation in the NT group. The majority of patients were satisfied with their outcome (LDT 84% (n = 26); NT 87% (n = 27); P = .72). CONCLUSION: Patients with ER deficit secondary to severe rotator cuff deficiency with and without glenohumeral arthritis undergoing reverse total shoulder arthroplasty do not have significantly improved ER or patient-reported outcome measures with LDT.


Assuntos
Artrite , Artroplastia do Ombro , Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Humanos , Transferência Tendinosa , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Músculos Superficiais do Dorso/cirurgia , Resultado do Tratamento , Lesões do Manguito Rotador/cirurgia , Artrite/cirurgia , Dor , Amplitude de Movimento Articular
5.
J Shoulder Elbow Surg ; 32(10): 1999-2007, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37209903

RESUMO

BACKGROUND: Shoulder arthroplasty procedures are widely indicated, and the number of shoulder arthroplasty procedures has drastically increased over the years. Rapid expansion of the utilization of reverse total shoulder arthroplasty has outpaced the more modest growth of anatomic total shoulder arthroplasty (aTSA) while shoulder hemiarthroplasty (HA) has trended down. Recently, shoulder prostheses have transitioned to increasingly modular systems offering more individualized options with the potential for decreased pain and increased range of motion. However, increased primary procedures has resulted in increased revision surgeries, with one potential cause being fretting and corrosion damage within these modular systems. METHODS: Following institutional review board approval, 130 retrieved aTSA and 135 HA explants were identified through database query. Humeral stem and head components were included in all 265 explants, whereas 108 included polyethylene glenoid liner components. All explanted components were macroscopically evaluated for standard damage modes, and taper junctions were microscopically examined for fretting/corrosion using a modified Goldberg-Cusick classification system that was 4-quadrant graded for both the male and female component. Medical records were reviewed for patient demographics and surgical information. RESULTS: In this series, 158 of explants were from female patients (male = 107), and 162 explants were from the right shoulder. Average age at implantation was 61 years (range: 24-83), average age at explanation was 66 years (range, 32-90), and average duration of implantation was 61.4 months (range, 0.5-240). Scratching, edge deformation, and burnishing were the most commonly observed standard damage modes. Of the 265 explants, 146 had a male stem component vs. 118 with a female stem component. Average summed fretting grades on male and female stem components were 8.3 and 5.9, respectively (P < .001). Average summed corrosion grades for male and female stem components were 8.2 and 6.2, respectively (P < .001). Wider male tapers (>11 mm) showed significantly less fretting and corrosion (P < .001). Lastly, mismatched metal compositions between the head and stem components showed greater fretting and corrosion damage (P = .002). CONCLUSION: In this series of 265 aTSA and HA explants, there was substantial damage present on the explanted components. All components demonstrated macroscopic damage. In this retrieval study, small-tapered male stems with small, thin female heads and mismatched metal composition between components were risk factors for increased implant wear. As shoulder arthroplasty volume increases, optimizing design is paramount for long-term success. Additional work could determine the clinical significance of these findings.


Assuntos
Artroplastia de Quadril , Artroplastia do Ombro , Prótese de Quadril , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prótese de Quadril/efeitos adversos , Artroplastia do Ombro/efeitos adversos , Cabeça do Fêmur , Falha de Prótese , Desenho de Prótese , Corrosão , Metais
6.
J Shoulder Elbow Surg ; 32(1): 201-212, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36202200

RESUMO

BACKGROUND: Morse taper junction tribocorrosion is recognized as an important failure mode in total hip arthroplasty. Although taper junctions are used in almost all shoulder arthroplasty systems currently available in the United States, with large variation in design, limited literature has described comparable analyses of taper damage in these implants. In this study, taper junction damage in retrieved reverse total shoulder arthroplasty (RTSA) implants was assessed and analyzed. METHODS: Fifty-seven retrieved RTSAs with paired baseplate and glenosphere components with Morse taper junctions were identified via database query; 19 of these also included paired humeral stems and trays or spacers with taper junctions. Components were graded for standard damage modes and for fretting and corrosion with a modified Goldberg-Cusick classification system. Medical records and preoperative radiographs were reviewed. Comparative analyses were performed assessing the impact of various implant, radiographic, and patient factors on taper damage. RESULTS: Standard damage modes were commonly found at the evaluated trunnion junctions, with scratching and edge deformation damage on 76% and 46% of all components, respectively. Fretting and corrosion damage was also common, observed on 86% and 72% of baseplates, respectively, and 23% and 40% of glenospheres, respectively. Baseplates showed greater moderate to severe (grade ≥ 3) fretting (43%) and corrosion (27%) damage than matched glenospheres (fretting, 9%; corrosion, 13%). Humeral stems showed moderate to severe fretting and corrosion on 28% and 30% of implants, respectively; matched humeral trays or spacers showed both less fretting (14%) and less corrosion (17%). On subgroup analysis, large-tapered implants had significantly lower summed fretting and corrosion grades than small-tapered implants (P < .001 for both) on glenospheres; paired baseplate corrosion grades were also significantly lower (P = .031) on large-tapered implants. Factorial analysis showed that bolt reinforcement of the taper junction was also associated with less fretting and corrosion damage on both baseplates and glenospheres. Summed fretting and corrosion grades on glenospheres with trunnions (male) were significantly greater than on glenospheres with bores (female) (P < .001 for both). CONCLUSIONS: Damage to the taper junction is commonly found in retrieved RTSAs and can occur after only months of being implanted. In this study, tribocorrosion predominantly occurred on the taper surface of the baseplate (vs. glenosphere) and on the humeral stem (vs. tray or spacer), which may relate to the flexural rigidity difference between the titanium and cobalt-chrome components. Bolt reinforcement and the use of large-diameter trunnions led to less tribocorrosion of the taper junction. The findings of this study provide evidence for the improved design of RTSA prostheses to decrease tribocorrosion.


Assuntos
Artroplastia de Quadril , Artroplastia do Ombro , Prótese de Quadril , Masculino , Feminino , Humanos , Falha de Prótese , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Corrosão
7.
J Shoulder Elbow Surg ; 31(8): e399-e404, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35121121

RESUMO

BACKGROUND: Staged bilateral shoulder arthroplasty procedures have been shown to have good functional outcomes. The next step is to explore the option of simultaneous bilateral shoulder arthroplasty (SBSA). We report on the first case series of SBSA in the United States. The purpose of this study was to examine the safety and postoperative complication profile of SBSA and provide a technique reference for surgeons considering performing or investigating this procedure. METHODS: We conducted a retrospective record review of all the SBSA procedures performed by the senior author between 2007 and 2020. Patient demographic characteristics, surgical information, and postoperative data were collected. Data were compiled, and means, standard deviations, and ranges were calculated. Any readmissions or postoperative complications requiring revision were noted. A cohort of patients matched for age, sex, and body mass index with staged (sequential) bilateral total shoulder arthroplasty was analyzed for comparison. RESULTS: Thirteen patients were identified in the simultaneous group (SBSA). The mean age was 64 ± 15 years, with 9 women (69%) and 4 men (31%); the mean body mass index was 29.1 ± 7.5. The mean American Society of Anesthesiologists score was 2.55 ± 0.7, average blood loss was 364 ± 170 mL (range, 50-600 mL), 5 of 13 patients (38%) underwent blood transfusions, and the mean surgical time was 183 ± 42 minutes. Postoperatively, the mean visual analog scale pain score on postoperative day 1 was 4 ± 2 (range, 0-7), and the mean length of stay was 3.3 days. Postoperative complications included urinary tract infections in 2 patients, urinary retention in 2 patients, and recurrence of paroxysmal atrial fibrillation in 1 patient. No patient was readmitted within 90 days of surgery. One patient underwent a reoperation 2 years postoperatively for symptomatic hardware removal (cerclage cables around the tuberosities). A matched cohort of staged bilateral total shoulder arthroplasty patients was analyzed for comparison. Postoperative complications in the staged group included 1 reverse total shoulder arthroplasty patient with subjective instability that was managed with additional physical therapy. There were no documented readmissions within 90 days or revision arthroplasty procedures in either cohort. CONCLUSIONS: SBSA is a reasonable procedure that can be useful in select patients, with promising short-term safety noted in this series. Prospective randomized studies are needed to assess the long-term safety and efficacy of the procedure.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Idoso , Artroplastia/efeitos adversos , Artroplastia do Ombro/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Reoperação/efeitos adversos , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Resultado do Tratamento
8.
J Shoulder Elbow Surg ; 31(5): 1083-1095, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35051541

RESUMO

BACKGROUND: The use of reverse total shoulder arthroplasty and stemless anatomic total shoulder replacement has been increasing in the United States every year. Stemless humeral components in reverse total shoulder arthroplasty are only approved for clinical trials in the United States with an investigational device exception with limited data. METHODS: A systematic review on stemless reverse total shoulder arthroplasty was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. A search was conducted on November 25, 2020, using the MEDLINE/PubMed, Cochrane, and Embase databases. All articles were reviewed by 2 independent evaluators, with any conflicts or issues resolved by consensus or a final decision by the senior author. The primary outcomes extracted were complications, radiographic results, and outcome scores. RESULTS: We evaluated 10 studies that used either the Total Evolutive Shoulder System (TESS) or Verso implant. There were 430 total patients and 437 total procedures; 266 patients in the TESS group underwent a total of 272 procedures, and 164 patients in the Verso group underwent a total of 165 procedures. The mean age at the time of surgery was 73.8 years (range, 38-93 years). The mean follow-up period ranged from 6.4 to 101.6 months per study. There was an overall trend of improved clinical outcome scores, a 0.2% humeral component loosening rate, and an 11.2% complication rate. CONCLUSIONS: This review shows that the clinical and functional outcomes following stemless or metaphyseal reverse total shoulder arthroplasty are quite promising, especially with the low rate of humeral-sided complications. There continues to be a need for additional long-term studies and randomized clinical trials.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Artroplastia do Ombro/métodos , Humanos , Desenho de Prótese , Articulação do Ombro/cirurgia , Resultado do Tratamento
9.
J Shoulder Elbow Surg ; 32(9): 1762, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37394055
10.
J Shoulder Elbow Surg ; 27(2): 350-356, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29198939

RESUMO

BACKGROUND: The glenoid track concept has been proposed to correlate shoulder stability with bone loss. Accurate assessment of Hill-Sachs lesion size preoperatively may affect surgical planning and postoperative outcomes; however, no measurement method has been universally accepted. This study aimed to assess the accuracy and reliability of measuring Hill-Sachs lesion sizes using 3-dimensional (3D) computed tomography (CT). METHODS: Nine polyurethane humerus bone substitutes were used to create Hill-Sachs lesions of varying sizes with a combination of lesion depth (shallow, intermediate, and deep) and width (small, medium, and large). Specimens were scanned with a clinical CT scanner for size measurements and a micro-CT scanner for measurement of true lesion size. Six evaluators repeated measurements twice in a 2-week interval. Scans were measured by use of 3D CT reconstructions for length, width, and Hill-Sachs interval and with use of 2D CT for depth. The interclass correlation coefficient evaluated interobserver and intraobserver variability and percentage error, and Student t-tests assessed measurement accuracy. RESULTS: Interclass correlation coefficient reliability demonstrated strong agreement for all variables measured (0.856-0.975). Percentage error between measured length and measured depth and the true measurement significantly varied with respect to both lesion depth (P = .003 and P = .005, respectively) and lesion size (P = .049 and P = .004, respectively). DISCUSSION AND CONCLUSIONS: The 3D CT imaging is effective and reproducible in determining lesion size. Determination of Hill-Sachs interval width is also reliable when it is applied to the glenoid track concept. Measured values on 3D and 2-dimensional imaging using a conventional CT scanner may slightly underestimate true measurements.


Assuntos
Lesões de Bankart/diagnóstico , Imageamento Tridimensional/métodos , Modelos Anatômicos , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Lesões de Bankart/cirurgia , Fixação de Fratura , Humanos , Variações Dependentes do Observador , Período Pós-Operatório , Reprodutibilidade dos Testes , Articulação do Ombro/cirurgia
11.
J Shoulder Elbow Surg ; 26(4): 723-731, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28111182

RESUMO

Use of total shoulder arthroplasty has significantly increased during the past decade. For anatomic total shoulder arthroplasty, controversy exists regarding the best technique for detachment and repair of the subscapularis tendon. Options include tendon tenotomy, peel, lesser tuberosity osteotomy, and even subscapularis-sparing techniques. Inadequate healing of the subscapularis tendon can lead to postoperative pain, weakness, and instability. This review discusses the subscapularis pathoanatomy, different techniques for releasing and repairing the tendon, and reports biomechanical and clinical outcomes for each technique after total shoulder arthroplasty.


Assuntos
Artroplastia do Ombro/métodos , Osteotomia/métodos , Manguito Rotador/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Tenotomia/métodos , Fenômenos Biomecânicos , Humanos , Cabeça do Úmero/cirurgia , Manguito Rotador/anatomia & histologia
12.
J Shoulder Elbow Surg ; 26(8): 1383-1389, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28162887

RESUMO

BACKGROUND: Patients undergoing reverse total shoulder arthroplasty (RTSA) are at risk of significant perioperative blood loss. To date, few studies have examined the effectiveness of tranexamic acid (TXA) to reduce blood loss in the setting of RTSA. METHODS: In a prospective, double-blinded, single-surgeon trial, we analyzed 102 patients undergoing primary RTSA who were randomized to receive intravenous TXA (n = 53) or placebo (n = 49). Calculated total blood loss, drain output, and hemoglobin (Hb) drop were measured. Postoperative transfusions were recorded. Complications were assessed out to 6 weeks postoperatively. RESULTS: Total blood loss was less for the TXA group (1122.4 ± 411.6 mL) than the placebo group (1472.6 ± 475.4 mL, P < .001). Total drain output was less for the TXA group (221.4 ± 126.2 mL) than the placebo group (371.9 ± 166.3 mL , P < .001). Total Hb loss was less in the TXA group (154.57 ± 60.29 g) compared with the placebo group (200.1 ± 65.5 g, P = .001). Transfusion rates differed significantly at postoperative day 1; however, overall transfusion rates did not vary significantly. Seven patients (14.3%) and 12 units were transfused in the placebo group compared with 3 patients (5.7%) and 3 units in the TXA group. DISCUSSION: In this cohort of patients undergoing primary RTSA, TXA was effective in reducing total drain output, total Hb loss, and total blood loss compared with a placebo control.


Assuntos
Antifibrinolíticos/uso terapêutico , Artroplastia do Ombro/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Hemorragia Pós-Operatória/prevenção & controle , Ácido Tranexâmico/uso terapêutico , Idoso , Antifibrinolíticos/administração & dosagem , Artroplastia do Ombro/métodos , Transfusão de Sangue , Volume Sanguíneo , Método Duplo-Cego , Feminino , Hemoglobinas/metabolismo , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/terapia , Período Pós-Operatório , Estudos Prospectivos , Ácido Tranexâmico/administração & dosagem
13.
J Shoulder Elbow Surg ; 26(11): 2029-2037, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28893545

RESUMO

BACKGROUND: Larger glenosphere diameters have been used recently to increase prosthesis stability and impingement-free range of motion in reverse total shoulder arthroplasty. The goal of this study was to evaluate the rate of polyethylene wear for 32-mm and 40-mm glenospheres. METHODS: Glenospheres (32 mm and 40 mm, n = 6/group) and conventional polyethylene humeral liners underwent a 5-million cycle (MC) wear simulation protocol. Abduction-adduction and flexion-extension motion profiles were alternated every 250,000 cycles. At each interval, mass loss was determined and converted to volume loss and wear rate. At 0, 2.5 MC, and 5 MC, liners were imaged using micro-computed tomography to determine surface deviation. White light interferometry was performed on liners and glenospheres at 0 and 5 MC to quantify surface roughness. Wear particle morphology was characterized by environmental scanning electron microscopy. RESULTS: Total volume loss was significantly higher in 40-mm liners from 1.5 MC onward (P < .05). Overall, volumetric wear rate was significantly higher in 40-mm liners compared with 32-mm glenospheres (81.7 ± 23.9 mm3/MC vs. 68.0 ± 18.9 mm3/MC; P < .001). However, micro-computed tomography surface deviation results demonstrated increased linear penetration on 32-mm glenospheres compared with 40-mm glenospheres (0.36 ± 0.03 µm vs. 0.28 ± 0.01 µm; P = .002). Surface roughness measurements showed no difference for liners; however, increased roughness was noted for 40-mm glenospheres at 5 MC compared with 32 mm (P < .05). CONCLUSION: Larger glenospheres underwent significantly greater polyethylene volume loss and volumetric wear rates, whereas smaller glenospheres underwent greater polyethylene surface deviations. The enhanced stability provided by larger glenospheres must be weighed against the potential for increased polyethylene wear.


Assuntos
Artroplastia do Ombro , Teste de Materiais , Desenho de Prótese , Falha de Prótese , Prótese de Ombro , Simulação por Computador , Análise de Falha de Equipamento , Humanos , Imageamento Tridimensional , Polietileno , Microtomografia por Raio-X
14.
Artigo em Inglês | MEDLINE | ID: mdl-27090008

RESUMO

This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at http://www.elsevier.com/locate/withdrawalpolicy.

15.
Clin Orthop Relat Res ; 473(2): 663-73, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25388633

RESUMO

BACKGROUND: Reverse total shoulder arthroplasty (RTSA) allows the deltoid to substitute for the nonfunctioning rotator cuff. To date, it is unknown whether preoperative deltoid and rotator cuff parameters correlate with clinical outcomes. QUESTIONS/PURPOSES: We asked whether associations exist between 2-year postoperative results (ROM, strength, and outcomes scores) and preoperative (1) deltoid size; (2) fatty infiltration of the deltoid; and/or (3) fatty infiltration of the rotator cuff. METHODS: A prospective RTSA registry was reviewed for patients with cuff tear arthropathy or massive rotator cuff tears, minimum 2-year followup, and preoperative shoulder MRI. Final analysis included 30 patients (average age, 71±10 years; eight males, 22 females). Only a small proportion of patients who received an RTSA at our center met inclusion and minimum followup requirements (30 of 222; 14%); however, these patients were found to be similar at baseline to the overall group of patients who underwent surgery in terms of age, gender, and preoperative outcomes scores. The cross-sectional area of the anterior, middle, and posterior deltoid was measured on axial proton density-weighted MRI. Fatty infiltration of the deltoid, supraspinatus, infraspinatus, teres minor, and subscapularis were quantitatively assessed on sagittal T1-weighted MR images. Patients were followed for Constant-Murley score, American Shoulder and Elbow Surgeons (ASES) scores, subjective shoulder value, pain, ROM, and strength. Correlations of muscle parameters with all outcomes measures were calculated. RESULTS: Preoperative deltoid size correlated positively with postoperative Constant-Murley score (67.27±13.07) (ρ=0.432, p=0.017), ASES (82.64±14.25) (ρ=0.377; p=0.40), subjective shoulder value (82.67±17.89) (ρ=0.427; p=0.019), and strength (3.72 pounds±2.99 pounds) (ρ=0.454; p=0.015). Quantitative deltoid fatty infiltration (7.91%±4.32%) correlated with decreased postoperative ASES scores (ρ=-0.401; p=0.047). Quantitative fatty infiltration of the infraspinatus (30.47%±15.01%) correlated with decreased postoperative external rotation (34.13°±16.80°) (ρ=-0.494; p=0.037). CONCLUSIONS: Larger preoperative deltoid size correlates with improved validated outcomes scores, whereas fatty infiltration of the deltoid and infraspinatus may have deleterious effects on validated outcomes scores and ROM after RTSA. The current study is a preliminary exploration of this topic; future studies should include prospective enrollment and standardized MRI with a multivariate statistical approach. Quantitative information attained from preoperative imaging not only holds diagnostic value, but, should future studies confirm our findings, also might provide prognostic value. This information may prove beneficial in preoperative patient counseling and might aid preoperative and postoperative decision-making by identifying subpopulations of patients who may benefit by therapy aimed at improving muscle properties. LEVEL OF EVIDENCE: Level III, prognostic study.


Assuntos
Tecido Adiposo/patologia , Artroplastia de Substituição , Músculo Deltoide/patologia , Manguito Rotador/patologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Substituição/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Amplitude de Movimento Articular , Estudos Retrospectivos , Articulação do Ombro/fisiopatologia , Resultado do Tratamento
16.
Instr Course Lect ; 64: 193-202, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25745905

RESUMO

The number of shoulder arthroplasty procedures performed in the United States is steadily increasing as a result of an expansion in implant options, clinical indications, and surgical experience. Available options include stemmed implants, short-stemmed or stemless prostheses, fracture-specific designs, resurfacing implants, partial surface replacement, metal-backed or polyethylene glenoid components designed for cementation or bone ingrowth, and reverse total shoulder arthroplasty. Efforts to re-create anatomy, improve outcomes, and avoid complications have resulted in many changes in prosthesis design. Despite these changes, failures still occur, and revision surgery is sometimes necessary. A thorough knowledge of current arthroplasty options, indications, and the principles of implantation is necessary to optimize outcomes after shoulder arthroplasty.


Assuntos
Artroplastia de Substituição/métodos , Artropatias/cirurgia , Prótese Articular , Articulação do Ombro/cirurgia , Humanos , Desenho de Prótese
17.
J Shoulder Elbow Surg ; 24(10): 1653-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26119632

RESUMO

BACKGROUND: With growing attention being paid to quality and cost-effectiveness in health care, outcome evaluations are becoming increasingly important. This determination can be especially difficult in reverse shoulder arthroplasty (RSA) given the complex pathology and extensive disabilities in this patient population. This study evaluated the use of 3 validated questionnaires used to assess outcomes for RSA. METHODS: Using a database of patients treated with RSA, we assessed preoperative and postoperative Constant-Murley Scores, American Shoulder and Elbow Surgeons Scores, and Subjective Shoulder Values in 148 shoulders. The outcomes at each scoring period were described, and the scores were compared with one another as well as with active range of motion. RESULTS: There were no significant differences in the mean improvement of any of the scores. Improvements in all of the outcome scales were correlated with each other and with improvement in forward elevation but not with external rotation. Multivariate regression analysis the 3 outcome measures was able to predict 38.9% of the variation in improvement in functional outcomes (forward elevation). This was only slightly greater than that provided by improvements in the outcome variable Constant-Murley score alone (36.7%). CONCLUSIONS: The 3 shoulder outcome scores evaluated, regardless of whether they were patient reported or physician based, appear to appropriately reflect improvements after RSA with equal validity. The objective physician-assessed Constant-Murley score had the strongest correlation with function of the arm, and use of a combination of all 3 outcome scores did not increase the ability to predict range of motion compared with using the Constant-Murley score alone.


Assuntos
Artroplastia de Substituição/métodos , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Inquéritos e Questionários , Humanos , Período Pós-Operatório , Período Pré-Operatório , Amplitude de Movimento Articular , Rotação , Resultado do Tratamento
18.
J Shoulder Elbow Surg ; 24(5): 814-22, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25487898

RESUMO

BACKGROUND: The "rocking horse" phenomenon is considered the main cause of glenoid component loosening by eccentric loading of the glenoid rim. This study aimed to investigate the influence of increasing glenohumeral implant mismatch on bone-implant interface micromotion in a cemented all-polyethylene pegged glenoid biomechanical model. METHODS: Five glenoid sizes, 40 mm, 44 mm, 48 mm, 52 mm, and 56 mm, representing +2 mm, +6 mm, +10 mm, +14 mm, and +18 mm glenohumeral mismatch, respectively, were cyclically loaded according to ASTM Standard F2028-08 at a constant frequency of 2 Hz to a size-dependent humeral head subluxation translation. Additional glenoid components were cyclically loaded to their subluxation translations at a constant humeral head rate of 4.4 mm/s. Component micromotion was characterized as compression, distraction, and superior-inferior translation measured by differential variable reluctance transducers. RESULTS: During constant frequency tests, 52-mm and 56-mm glenoids were unable to complete cyclic testing because of catastrophic failure of the glenoid-implant interface and permanent glenoid deformation, probably due to increasing severity of testing parameters. When tested at a constant humeral head speed, 48-mm, 52-mm, and 56-mm glenoids had significantly increased glenoid distraction and glenoid translation at cycle 50,000 compared with cycle 1. Distraction and translation measurements for 52-mm and 56-mm glenoids were significantly greater compared with 40-mm, 44-mm, and 48-mm glenoids at 50,000 cycles. CONCLUSIONS: In a biomechanical model, optimal glenohumeral mismatch in cemented pegged glenoid implants is multifactorial and has not been definitively established. However, our data suggest that a radial mismatch of less than +10 mm may decrease the risk of glenoid micromotion.


Assuntos
Artroplastia de Substituição/instrumentação , Prótese Articular , Desenho de Prótese , Falha de Prótese/etiologia , Articulação do Ombro/cirurgia , Fenômenos Biomecânicos , Cimentos Ósseos/uso terapêutico , Análise de Falha de Equipamento , Cavidade Glenoide , Humanos , Cabeça do Úmero , Teste de Materiais , Movimento (Física) , Polietileno/uso terapêutico
19.
J Shoulder Elbow Surg ; 24(9): 1372-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25842031

RESUMO

BACKGROUND: Although short-term outcomes of reverse total shoulder arthroplasty (rTSA) remain promising, the most commonly cited complication remains prosthetic instability. A retentive rTSA liner is commonly used to increase system constraint; however, no studies have evaluated the rate of polyethylene wear. Our hypothesis was that more constrained retentive liners would have higher wear rates than nonretentive liners. METHODS: Six nonretentive and six retentive rTSA non-cross-linked polyethylene liners were subjected to 4.5 million cycles of alternating cycles of abduction-adduction and flexion-extension motion loading profiles. The rTSA liners were assessed for gravimetric wear loss, 3-dimensional volumetric loss by novel micro-computed tomography analysis, and particulate wear debris analysis. RESULTS: Volumetric wear rates were significant at 7 specific time points (1.0, 2.0, 2.5, 3.25, 3.75, 4.0, and 4.5 million cycles) throughout testing between nonretentive and retentive liners; however, overall mean volumetric wear rate was not statistically significant (P = .076). Total volume loss between liner test groups was found to be significant starting after 3.5 million cycles of testing. Maximum and mean surface deviations were found to be larger for retentive liners vs. nonretentive liners by micro-computed tomography analysis across the entire articulation surface. DISCUSSION AND CONCLUSION: Retentive liners undergo significantly greater volume loss and greater surface deviation compared with nonretentive liners, most notably at later time points representing extended implantation times. Additional stability afforded by retentive liners should be balanced against the potential for increased wear and potential for subsequent polyethylene wear-induced aseptic loosening.


Assuntos
Artroplastia de Substituição/instrumentação , Falha de Prótese , Articulação do Ombro , Anatomia Transversal , Materiais Biocompatíveis , Simulação por Computador , Análise de Falha de Equipamento , Humanos , Polietileno , Desenho de Prótese , Articulação do Ombro/cirurgia , Microtomografia por Raio-X
20.
J Shoulder Elbow Surg ; 24(12): 1915-25, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26212759

RESUMO

BACKGROUND: The purpose of this study was to explore relationships between damage modes in explanted reverse total shoulder arthroplasty (RTSA) components, patient and radiographic risk factors, and functional data to elucidate trends in RTSA failure. METHODS: Fifty RTSA systems, retrieved from 44 patients, with 50 polyethylene (PE) liners, 30 glenospheres, 21 glenoid baseplates, 13 modular humeral metaphases, and 17 humeral stems, were examined for damage modes, including abrasion, burnishing, dishing, embedding, scratching, and pitting. PE liners were also analyzed for delamination and edge deformation. Charts were reviewed for patient, surgical, and functional data. Pre-revision radiographs were analyzed for scapular notching and loosening. RESULTS: Average term of implantation was 20 months (range, 0-81 months). Metallic components exhibited abrasion, burnishing, dishing, pitting, and scratching. PE liners displayed all damage modes. Damage was exhibited on 93% of glenospheres and 100% of PE liners. Of 29 aseptic shoulders, 13 showed evidence of scapular notching and 5 of humeral loosening. There was a moderate correlation between radiographically observed implant failure or dissociation and PE embedding (r = 0.496; P < .001). There were weak and moderate correlations between scapular notching severity and PE dishing (r = 0.496; P = .006), embedding (r = 0.468; P = .010), and delamination (r = 0.384; P = .040). CONCLUSIONS: To date, this is the largest series of retrieved RTSA components and the first to relate damage modes to radiographic and clinical data. Most damage was observed on the PE liners, on both the articular surface and rim, and glenosphere components. Correlation of retrieval findings with radiographic and clinical data may help establish predictors of prostheses at risk for failure.


Assuntos
Artroplastia de Substituição/efeitos adversos , Artropatias/cirurgia , Prótese Articular , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Artropatias/diagnóstico por imagem , Artropatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação/tendências , Fatores de Risco , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia