Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1209: 339837, 2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35569848

RESUMO

The SuperCam instrument, onboard the Perseverance rover (Mars 2020 mission) is designed to perform remote analysis on the Martian surface employing several spectroscopic techniques such as Laser Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman (TRR), Time-Resolved Fluorescence (TRF) and Visible and Infrared (VISIR) reflectance. In addition, SuperCam also acquires high-resolution images using a color remote micro-imager (RMI) as well as sounds with its microphone. SuperCam has three main subsystems, the Mast Unit (MU) where the laser for chemical analysis and collection optics are housed, the Body Unit (BU) where the different spectrometers are located inside the rover, and the SuperCam Calibration Target (SCCT) located on the rover's deck to facilitate calibration tests at similar ambient conditions as the analyzed samples. To perform adequate calibrations on Mars, the 22 mineral samples included in the complex SCCT assembly must have a very homogeneous distribution of major and minor elements. The analysis and verification of such homogeneity for the 5-6 replicates of the samples included in the SCCT has been the aim of this work. To verify the physic-chemical homogeneity of the calibration targets, micro Energy Dispersive X-ray Fluorescence (EDXRF) imaging was first used on the whole surface of the targets, then the relative abundances of the detected elements were computed on 20 randomly distributed areas of 100 × 100 µm. For those targets showing a positive Raman response, micro-Raman spectroscopy imaging was performed on the whole surface of the targets at a resolution of 100 × 100 µm. The %RSD values (percent of relative standard deviation of mean values) for the major elements measured with EDXRF were compared with similar values obtained by two independent LIBS set-ups at spot sizes of 300 µm in diameter. The statistical analysis showed which elements were homogeneously distributed in the 22 mineral targets of the SCCT, providing their uncertainty values for further calibration. Moreover, nine of the 22 targets showed a good Raman response and their mineral distributions were also studied. Those targets can be also used for calibration purposes of the Raman part of SuperCam using the wavenumbers of their main Raman bands proposed in this work.


Assuntos
Meio Ambiente Extraterreno , Marte , Calibragem , Meio Ambiente Extraterreno/química , Minerais/análise , Análise Espectral Raman/métodos
2.
J Med Chem ; 42(2): 213-20, 1999 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-9925726

RESUMO

The platelet P2T receptor plays a major role in platelet aggregation, and its antagonists are predicted to have significant therapeutic potential as antithrombotic agents. We have explored analogues of adenosine triphosphate (ATP), which is a weak, nonselective but competitive P2T receptor antagonist. Modification of the polyphosphate side chain to prevent breakdown to the agonist adenosine diphosphate (ADP) and substitution of the adenine moiety to enhance affinity and selectivity for the P2T receptor led to the identification of 10e (AR-C67085MX), having an IC50 of 2.5 nM against ADP-induced aggregation of human platelets. Compound 10e was the first very potent antagonist of the P2T receptor, with a selectivity for that subtype of the P2 receptor family of >1000-fold. Further modification of the structure produced compound 10l (AR-C69931MX) having an IC50 of 0.4 nM. In vivo, at maximally effective antithrombotic doses, there is little prolongation of bleeding time (1.4-fold), which is in marked contrast to the 5-6-fold found with GPIIb/IIIa antagonists.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Plaquetas/efeitos dos fármacos , Proteínas de Membrana , Inibidores da Agregação Plaquetária/farmacologia , Antagonistas do Receptor Purinérgico P2 , Trombose/tratamento farmacológico , Monofosfato de Adenosina/química , Monofosfato de Adenosina/farmacologia , Monofosfato de Adenosina/uso terapêutico , Plaquetas/metabolismo , Humanos , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Inibidores da Agregação Plaquetária/química , Inibidores da Agregação Plaquetária/uso terapêutico , Receptores Purinérgicos P2Y12 , Espectrometria de Massas de Bombardeamento Rápido de Átomos
4.
Nature ; 412(6847): 617-20, 2001 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-11493914

RESUMO

The drive towards the development of molecular electronics is placing increasing demands on the level of control that must be exerted on the electronic structure of materials. Proposed device architectures ultimately rely on tuning the interactions between individual electronic states, which amounts to controlling the detailed spatial structure of the electronic wavefunctions in the constituent molecules. Few experimental tools are available to probe this spatial structure directly, and the shapes of molecular wavefunctions are usually only known from theoretical investigations. Here we present scanning tunnelling spectroscopy measurements of the two-dimensional structure of individual wavefunctions in metallic single-walled carbon nanotubes; these measurements reveal spatial patterns that can be directly understood from the electronic structure of a single graphite sheet, and which represent an elegant illustration of Bloch's theorem at the level of individual wavefunctions. We also observe energy-dependent interference patterns in the wavefunctions and exploit these to directly measure the linear electronic dispersion relation of the metallic single-walled carbon nanotube.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA