1.
Artigo em Zh | MEDLINE | ID: mdl-12181794

RESUMO

OBJECTIVE: To study the difference between two internal fixation methods Kaneda and Z-plate in the operation of anterior surgical approach and decompression after thoracolumbar fractures. METHODS: The bio-mechanical structure of the internal fixture, install when operating, complications and time of the operation were compared in the cases by Kaneda and Z-plate. RESULTS: Z-plate method had the following characteristics: reasonable of the bio-mechanical structure; stability after internal fixture being installed; capability of completely propping up the injured centrum and keeping the height of middle-column; simple operation when installing internal fixture and shorter time of operation (1.1 hours, P < 0.05); fewer complications. CONCLUSION: Z-plate is an ideal internal fixation method in the operation of anterior surgical approach after thoracolumbar fractures.


Assuntos
Fixação Interna de Fraturas/métodos , Vértebras Lombares/lesões , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/lesões , Adolescente , Adulto , Placas Ósseas , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Fixadores Internos , Masculino , Pessoa de Meia-Idade