Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Clin Chem Lab Med ; 61(1): 78-85, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36279170

RESUMO

OBJECTIVES: Vitamin D-binding protein (VDBP), a serum transport protein for 25-hydroxyvitamin D [25(OH)D], has three common proteoforms which have co-localized amino acid variations and glycosylation. A monoclonal immunoassay was found to differentially detect VDBP proteoforms and methods using liquid chromatography-tandem mass spectrometry (LC-MS/MS) might be able to overcome this limitation. Previously developed multiple reaction monitoring LC-MS/MS methods for total VDBP quantification represent an opportunity to probe the potential effects of proteoforms on proteolysis, instrument response and quantification accuracy. METHODS: VDBP was purified from homozygous human donors and quantified using proteolysis or acid hydrolysis and LC-MS/MS. An interlaboratory comparison was performed using pooled human plasma [Standard Reference Material® 1950 (SRM 1950) Metabolites in Frozen Human Plasma] and analyses with different LC-MS/MS methods in two laboratories. RESULTS: Several shared peptides from purified proteoforms were found to give reproducible concentrations [≤2.7% coefficient of variation (CV)] and linear instrument responses (R2≥0.9971) when added to human serum. Total VDBP concentrations from proteolysis or amino acid analysis (AAA) of purified proteoforms had ≤1.92% CV. SRM 1950, containing multiple proteoforms, quantified in two laboratories resulted in total VDBP concentrations with 7.05% CV. CONCLUSIONS: VDBP proteoforms were not found to cause bias during quantification by LC-MS/MS, thus demonstrating that a family of proteins can be accurately quantified using shared peptides. A reference value was assigned for total VDBP in SRM 1950, which may be used to standardize methods and improve the accuracy of VDBP quantification in research and clinical samples.


Assuntos
Espectrometria de Massas em Tandem , Proteína de Ligação a Vitamina D , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Proteólise , Vitamina D , Proteínas Sanguíneas/metabolismo , Aminoácidos/metabolismo
2.
Anal Bioanal Chem ; 415(5): 809-821, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36507958

RESUMO

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.


Assuntos
Ácido Fólico , Espectrometria de Massas em Tandem , Humanos , Ácido Fólico/análise , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Ácido Ascórbico
3.
Anal Bioanal Chem ; 410(9): 2321-2329, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29435636

RESUMO

Dietary fatty acids can be both beneficial and detrimental to human health depending on the degree and type of saturation. Healthcare providers and research scientists monitor the fatty acid content of human plasma and serum as an indicator of health status and diet. In addition, both the Centers for Disease Control & Prevention (CDC) and the National Institutes of Health - Office of Dietary Supplements are interested in circulating fatty acids (FAs) because they may be predictive of coronary heart disease. The National Institute of Standards and Technology (NIST) provides a wide variety of reference materials (RMs) and Standard Reference Materials® (SRM®s) including blood, serum, plasma, and urine with values assigned for analytes of clinical interest. NIST SRM 2378 Fatty Acids in Frozen Human Serum was introduced in 2015 to help validate methods used for the analysis of FAs in serum, and consists of three different pools of serum acquired from (1) healthy donors who had taken fish oil dietary supplements (at least 1000 mg per day) for at least one month (level 1 material), (2) healthy donors who had taken flaxseed oil dietary supplements (at least 1000 mg per day) for at least one month (level 2 material), and (3) healthy donors eating "normal" diets who had not taken dietary supplements containing fish or plant oils (level 3 material). The use of dietary supplements by donors provided SRMs with natural endogenous ranges of FAs at concentrations observed in human populations. Results from analyses using two methods at NIST, including one involving a novel microwave-assisted acid hydrolysis procedure, and one at the CDC are presented here. These results and their respective uncertainties were combined to yield certified values with expanded uncertainties for 12 FAs and reference values with expanded uncertainties for an additional 18 FAs.


Assuntos
Cromatografia Gasosa/métodos , Suplementos Nutricionais , Ácidos Graxos/sangue , Ionização de Chama/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Preservação de Sangue , Cromatografia Gasosa/normas , Criopreservação , Suplementos Nutricionais/análise , Ácidos Graxos/normas , Ácidos Graxos Insaturados/sangue , Ácidos Graxos Insaturados/normas , Óleos de Peixe/administração & dosagem , Óleos de Peixe/sangue , Ionização de Chama/normas , Congelamento , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Óleos de Plantas/administração & dosagem , Óleos de Plantas/análise , Padrões de Referência
4.
Anal Bioanal Chem ; 410(4): 1265-1278, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29222652

RESUMO

A Standard Reference Material (SRM) of seaweed, SRM 3232 Kelp Powder (Thallus laminariae) has been developed to support food and dietary supplement measurements in compliance with the Food Safety Modernization Act (FSMA) and the Dietary Supplement Health and Education Act of 1994 (DSHEA). The material was characterized for nutritional minerals, arsenic species, isomers of vitamin K1, proximates, and toxic elements. Kelp is a rich source of vitamins and minerals, and it is an excellent source of dietary iodine. Kelp also contains a large amount of arsenic, which is toxic as inorganic species but much less so as organic species. To capture the dietary profile of kelp, certified values were issued for As, Ca, Cd, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, Na, Pb, and Zn. Reference values for proximates were assigned. For the first time, a certified value for iodine, reference values for isomers of vitamin K1, and reference values for arsenic species including arsenosugars were assigned in a seaweed. SRM 3232 fills a gap in Certified Reference Materials (CRMs) needed for quality assurance and method validation in the compositional measurements of kelp and similar seaweeds used as food and as dietary supplements. Graphical Absract Arsenic species and isomers of vitamin K1 were determined in the development of SRM 3232 Kelp Powder (Thallus laminariae).


Assuntos
Kelp/química , Pós , Cromatografia Líquida , Padrões de Referência , Espectrometria de Massas em Tandem
5.
Anal Chem ; 89(19): 10461-10467, 2017 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-28930436

RESUMO

A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, and volatiles. The constituents have been determined by multiple analytical methods with measurements at NIST and at the Centers for Disease Control and Prevention, and with confirmatory measurements by commercial laboratories. This effort highlights the development of the first SRM for reduced nicotine and reduced tobacco-specific nitrosamines with certified values for composition.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Produtos do Tabaco/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Congelamento , Cromatografia Gasosa-Espectrometria de Massas/normas , Nicotina/análise , Nicotina/normas , Nitrosaminas/análise , Nitrosaminas/normas , Transição de Fase , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Produtos do Tabaco/normas , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/normas
6.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28375002

RESUMO

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Espectrometria de Massas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Padrões de Referência , Valores de Referência , Estereoisomerismo , Estados Unidos , United States Government Agencies
7.
Anal Bioanal Chem ; 409(4): 949-960, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27832301

RESUMO

Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical Abstract Separation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate.


Assuntos
Cromatografia Líquida/métodos , Isoflavonas/análise , Alimentos de Soja/análise , Espectrofotometria Ultravioleta/métodos , Isótopos , Espectrometria de Massas , Espectroscopia de Prótons por Ressonância Magnética , Padrões de Referência
8.
Anal Chem ; 85(24): 11732-8, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24187941

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NIH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.


Assuntos
Análise Química do Sangue/normas , Metabolômica/normas , Adulto , Aminoácidos/sangue , Biomarcadores/sangue , Carotenoides/sangue , Ácidos Graxos/sangue , Feminino , Humanos , Masculino , National Institutes of Health (U.S.) , Padrões de Referência , Estados Unidos , Vitaminas/sangue
9.
Anal Bioanal Chem ; 405(13): 4539-48, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23529413

RESUMO

The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.


Assuntos
Ácido Ascórbico/normas , Cromatografia Líquida/normas , Suplementos Nutricionais/normas , Alimentos Formulados/normas , Ácido Ascórbico/análise , Suplementos Nutricionais/análise , Alimentos Formulados/análise , Humanos , Lactente , Controle de Qualidade , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes
10.
Anal Bioanal Chem ; 405(13): 4531-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23371533

RESUMO

As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed Standard Reference Material (SRM) 3274 Botanical Oils Containing Omega-3 and Omega-6 Fatty Acids and SRM 3275 Omega-3 and Omega-6 Fatty Acids in Fish Oil. SRM 3274 consists of one ampoule of each of four seed oils (3274-1 Borage (Borago officinalis), 3274-2 Evening Primrose (Oenothera biennis), 3274-3 Flax (Linium usitatissimum), and 3274-4 Perilla (Perilla frutescens)), and SRM 3275 consists of two ampoules of each of three fish oils (3275-1 a concentrate high in docosahexaenoic acid, 3275-2 an anchovy oil high in docosahexaenoic acid and eicosapentaenoic acid, and 3275-3 a concentrate containing 60% long-chain omega-3 fatty acids). Each oil has certified and reference mass fraction values for up to 20 fatty acids. The fatty acid mass fraction values are based on results from analyses using gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS). These SRMs will complement other reference materials currently available with mass fractions for similar analytes and are part of a series of SRMs being developed for dietary supplements.


Assuntos
Suplementos Nutricionais/normas , Ácidos Docosa-Hexaenoicos/normas , Ácido Eicosapentaenoico/normas , Óleos de Peixe/normas , Óleos de Plantas/normas , Cromatografia Gasosa , Suplementos Nutricionais/análise , Ácidos Docosa-Hexaenoicos/isolamento & purificação , Ácido Eicosapentaenoico/isolamento & purificação , Óleos de Peixe/química , Ionização de Chama , Humanos , Óleos de Plantas/química , Padrões de Referência , Valores de Referência
11.
J AOAC Int ; 96(6): 1281-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24645505

RESUMO

Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.


Assuntos
Química Farmacêutica/normas , Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Vitaminas/análise , Carotenoides/análise , Química Farmacêutica/métodos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Comprimidos , Estados Unidos , Vitaminas/química
12.
Anal Chem ; 84(2): 956-62, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22141317

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health's Office of Dietary Supplements (NIH-ODS), has developed a Standard Reference Material (SRM) for the determination of 25-hydroxyvitamin D [25(OH)D] in serum. SRM 972 Vitamin D in Human Serum consists of four serum pools with different levels of vitamin D metabolites and has certified and reference values for 25(OH)D(2), 25(OH)D(3), and 3-epi-25(OH)D(3). Value assignment of this SRM was accomplished using a combination of three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). Chromatographic resolution of the 3-epimer of 25(OH)D(3) proved to be essential for accurate determination of the metabolites.


Assuntos
Vitamina D/análogos & derivados , Cromatografia Líquida , Humanos , Espectrometria de Massas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vitamina D/análise , Vitamina D/sangue , Vitamina D/normas
13.
Anal Bioanal Chem ; 402(2): 749-62, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22015475

RESUMO

Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total ß-cryptoxanthin, total ß-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-ß-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.


Assuntos
Carotenoides/sangue , Colesterol/sangue , Vitaminas/sangue , Carotenoides/química , Colesterol/química , Cromatografia Líquida , Humanos , Estrutura Molecular , Padrões de Referência , Vitaminas/química
14.
J AOAC Int ; 94(3): 815-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21797009

RESUMO

The concentrations of selected fat-soluble vitamins and carotenoids in Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets have been determined by two independent LC methods, with measurements performed by the National Institute of Standards and Technology (NIST). This SRM has been prepared as part of a collaborative effort between NIST and the National Institutes of Health Office of Dietary Supplements. The SRM is also intended to support the Dietary Supplement Ingredient Database that is being established by the U.S. Department of Agriculture. The methods used at NIST to determine the concentration levels of vitamins A and E, and beta-carotene in the SRM used RPLC with absorbance detection. The relative precision of these methods ranged from 2 to 8% for the analytes measured. SRM 3280 is primarily intended for use in validating analytical methods for the determination of selected vitamins, carotenoids, and elements in multivitamin/multielement tablets and similar matrixes.


Assuntos
Carotenoides/química , Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Gorduras/química , Vitaminas/química , Absorciometria de Fóton , Suplementos Nutricionais/normas , Padrões de Referência , Sensibilidade e Especificidade , Comprimidos/química
15.
Anal Bioanal Chem ; 398(1): 425-34, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20582402

RESUMO

Nine organic acids (citric acid, galacturonic acid, glycolic acid, isocitric acid, malic acid, oxalic acid, quinic acid, shikimic acid, and tartaric acid) and two anions (phosphate and sulfate) were determined in a suite of Vaccinium berry-containing dietary supplement standard reference materials (SRMs). Following solvent extraction, three independent methods were utilized in the quantification of these compounds. The first method involved reversed-phase liquid chromatography with ultraviolet absorbance detection at 210 nm and isotope dilution mass spectrometry. The second method utilized ion chromatography with conductivity detection. Finally, gas chromatography with isotope dilution mass spectrometry detection was used following derivatization with N-methyl-N-trifluoroacetamide (MSTFA). The combined data from these methods was used for the assignment of organic acid levels in the seven candidate SRMs.


Assuntos
Ácidos/análise , Ácidos/normas , Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Frutas/química , Vaccinium/química , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Cromatografia Gasosa-Espectrometria de Massas , Marcação por Isótopo , Espectrometria de Massas , Padrões de Referência
16.
J AOAC Int ; 93(4): 1262-74, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20922961

RESUMO

Standard Reference Material (SRM) 1849 Infant/Adult Nutritional Formula has been issued by the National Institute of Standards and Technology (NIST) as a replacement for SRM 1846 Infant Formula, issued in 1996. Extraction characteristics of SRM 1846 have changed over time, as have NIST's analytical capabilities. While certified mass fraction values were provided for five constituents in SRM 1846 (four vitamins plus iodine), certified mass fraction values for 43 constituents are provided in SRM 1849 (fatty acids, elements, and vitamins) and reference mass fraction values are provided for an additional 43 constituents including amino acids and nucleotides, making it the most extensively characterized food-matrix SRM available from NIST.


Assuntos
Fórmulas Infantis/normas , Aminoácidos/análise , Comportamento Cooperativo , Ácidos Graxos/análise , Humanos , Lactente , Fórmulas Infantis/química , Padrões de Referência , Vitaminas/análise
17.
Clin Mass Spectrom ; 16: 11-17, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820515

RESUMO

Vitamin D plays a vital role in successful pregnancy outcomes for both the mother and fetus. Vitamin D is bound to vitamin D binding protein (VDBP) in blood and is carried to the liver, kidneys and other target tissues. Accurate measurements of the clinically measured metabolite of vitamin D, 25-hydroxyvitamin D [25(OH)D], depend on complete removal from the binding protein. It has been found that VDBP concentrations increase in maternal serum during pregnancy, obfuscating the accuracy of 25(OH)D concentration measurements in pregnant women. Additionally, measurements of VDBP concentrations during pregnancy have been performed using immunoassays, which suffer from variations due to differences in antibody epitopes, making clinical comparisons difficult. Quantification of VDBP is also of interest because changes in VDBP expression levels may indicate negative outcomes during pregnancy, such as preterm delivery and restricted fetal growth. To address the need for accurate measurement of VDBP during pregnancy, a method using liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was developed to quantify VDBP using isotopically labeled peptides as internal standards. This method was used to quantify VDBP in Standard Reference Material® (SRM) 1949 Frozen Human Prenatal Serum, which was prepared from separate serum pools of women who were not pregnant and women during each trimester of pregnancy. VDBP concentrations were found to be lowest in the serum pool from non-pregnant women and increased in each trimester. These data had good repeatability and were found to be suitable for reference value assignment of VDBP in SRM 1949.

18.
Anal Bioanal Chem ; 392(3): 427-38, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18677464

RESUMO

As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.


Assuntos
Frutas/química , Extratos Vegetais/análise , Extratos Vegetais/química , Serenoa/química , Ácidos Graxos/análise , Padrões de Referência , Esteróis/análise , Tocoferóis/química , beta Caroteno/análise
19.
J AOAC Int ; 100(5): 1294-1303, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28917261

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements and the Vitamin D Standardization Program, has recently issued a new serum-matrix Standard Reference Material (SRM): 2973 Vitamin D Metabolites in Frozen Human Serum (High Level). SRM 2973 was designed to provide a serum material with a total 25-hydroxyvitamin D [25(OH)D] concentration near 100 nmol/L to complement the existing serum-based SRMs with values assigned for total 25(OH)D between 20 and 80 nmol/L. Values were assigned for 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25(OH)D3, and total 25(OH)D [the sum of 25(OH)D2 + 25(OH)D3] using the NIST isotope dilution LC with tandem MS (MS/MS) reference measurement procedure (RMP) and related methods. SRM 2973 has a certified value of 98.4 ± 2.1 nmol/L for 25(OH)D3 and reference values of 1.59 ± 0.05 nmol/L for 25(OH)D2 and 5.23 ± 0.20 nmol/L for 3-epi-25(OH)D3. In addition, a candidate RMP for 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] based on LC-MS/MS was used to assign values to SRM 2973 and the existing SRM 972a Vitamin D Metabolites in Frozen Human Serum. Reference values for 24R,25(OH)2D3 were assigned to SRM 2973 (7.51 ± 0.26 nmol/L) and the four levels of SRM 972a: Level 1 (6.38 ± 0.23 nmol/L), Level 2 (3.39 ± 0.12 nmol/L), Level 3 (3.88 ± 0.013 nmol/L), and Level 4 (6.32 ± 0.22 nmol/L). The development of SRM 2973 [with a higher concentration of 25(OH)D3] and the addition of values for 24R,25(OH)2D3 assigned to both SRM 972a and SRM 2973 provide laboratories involved in vitamin D measurements with improved QA tools.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/normas , Calcifediol/sangue , Humanos , Espectrometria de Massas em Tandem/normas , Estados Unidos , Vitamina D
20.
Sci Total Environ ; 361(1-3): 249-66, 2006 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-16442152

RESUMO

Surface water samples from the Occoquan Watershed (Virginia, US) were collected during summer baseflow conditions and characterized by excitation-emission matrix (EEM) fluorescence spectroscopy and parallel factor analysis (PARAFAC). Based on 55 samples, PARAFAC identified three individual fluorophore moieties, which were attributed to humic-like, fulvic-like, and protein-like materials. The categorization of these seemingly universal fluorophore moieties in aqueous systems was consistent with expected analyte concentrations that were independently measured by traditional wet chemistry techniques. The relative distribution of the three fluorophore fractions varied among the different land use catchments, especially in locations of known anthropogenic activity. Distinctive relationships between the fulvic-like and protein-like materials were observed for catchments known to be influenced by anthropogenic activity and those believed to reflect more natural environments, suggesting that this technique could be used to monitor human impact on aquatic systems. Finally, PARAFAC can be used to provide estimates (+/-30%) of select analyte concentrations in surface water. The results of this study support the use of EEM and PARAFAC analyses by watershed managers and other personnel interested in understanding organic matter behavior in aquatic systems.


Assuntos
Monitoramento Ambiental/métodos , Modelos Teóricos , Benzopiranos/análise , Carbono/análise , Cloretos/análise , Substâncias Húmicas/análise , Metais/análise , Nitrogênio/análise , Fósforo/análise , Rios , Espectrometria de Fluorescência , Sulfatos/análise , Virginia , Poluentes Químicos da Água/análise , Abastecimento de Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA