Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Gene Ther ; 18(11): 1043-51, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21490685

RESUMO

Light-activated gene transduction (LAGT) is an approach to localize gene therapy via preactivation of cells with UV light, which facilitates transduction by recombinant adeno-associated virus vectors. Previous studies demonstrated that UVC induces LAGT secondary to pyrimidine dimer formation, whereas UVA induces LAGT secondary to reactive-oxygen species (ROS) generation. However, the empirical UVB boundary of these UV effects is unknown. Thus, we aimed to define the action spectra for UV-induced LAGT independent of DNA damage and determine an optimal wavelength to maximize safety and efficacy. UV at 288, 311 and 320 nm produced significant dose-dependent LAGT effects, of which the maximum (800-fold) was observed with 4 kJ m⁻² at 311 nm. Consistent with its robust cytotoxicity, 288 nm produced significantly high levels of DNA damage at all doses tested, whereas 311, 320 and 330 nm did not generate pyrimidine dimers and produced low levels of DNA damage detected by comet assay. Although 288 nm failed to induce ROS, the other wavelengths were effective, with the maximum (10-fold) effect observed with 30 kJ m⁻² at 311 nm. An in vivo pilot study assessing 311 nm-induced LAGT of rabbit articular chondrocytes demonstrated a significant 6.6-fold (P<0.05) increase in transduction with insignificant cytotoxicity. In conclusion, 311 nm was found to be the optimal wavelength for LAGT on the basis of its superior efficacy at the peak dose and its broad safety range that is remarkably wider than the other UV wavelengths tested.


Assuntos
Luz , Transdução Genética , Raios Ultravioleta , Animais , Morte Celular , Linhagem Celular , Ensaio Cometa , Dependovirus/genética , Feminino , Células HEK293 , Humanos , Camundongos , Coelhos , Espécies Reativas de Oxigênio/metabolismo
2.
J Invest Dermatol ; 113(3): 293-303, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10469324

RESUMO

In 1995, we reported the construction of a video-rate scanning laser confocal microscope for imaging human skin in vivo. Since then, we have improved the resolution, contrast, depth of imaging, and field of view. Confocal images of human skin are shown with experimentally measured lateral resolution 0.5-1.0 microm and axial resolution (section thickness) 3-5 microm at near-infrared wavelengths of 830 nm and 1064 nm; this resolution compares well to that of histology which is based on typically 5 microm thin sections. Imaging is possible to maximum depth of 350 microm over field of view of 160-800 microm. A mechanical skin-contact device was developed to laterally stabilize the imaging site to within +/- 25 microm in the presence of subject motion. Based on these results, we built a small, portable, and robust confocal microscope that is capable of imaging normal and abnormal skin morphology and dynamic processes in vivo, in both laboratory and clinical settings. We report advances in confocal microscope instrumentation and methods, an optimum range of parameters, improved images of normal human skin, and comparison of confocal images with histology.


Assuntos
Microscopia Confocal/instrumentação , Pele/ultraestrutura , Epiderme/ultraestrutura , Humanos
3.
Appl Opt ; 30(16): 2224-44, 1991 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20700199

RESUMO

A scalar scattering theory is developed that predicts the angular distribution of light scattered and the total integrated scatter from a randomly rough or inhomogeneous optical interference coating. Three types of random variation are considered: uncorrelated roughness, additive roughness, and uncorrelated index inhomogeneity. The scattering calculations are formulated so that the output of any conventional thin film analysis program along with a coating's surface or index statistics could be used to calculate the scattering distribution of a coating. The scattering calculations are compared to experimental measurements from a sixteen-layer high reflector coating with small additive roughness sigma = 2.4 A and large correlated roughness sigma = 93 A.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA