Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 32(10): 2884-2894, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34041815

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and results in significant morbidity and mortality. The Cox-Maze IV procedure (CMP-IV) has been shown to have excellent efficacy in returning patients to sinus rhythm, but there have been few reports of late follow-up in sizable cohorts of patients with longstanding persistent AF, the most difficult type of AF to treat. METHODS AND RESULTS: Between May 2003 and March 2020, 174 consecutive patients underwent a stand-alone CMP-IV for longstanding persistent AF. Rhythm outcome was assessed postoperatively for up to 10 years, primarily via prolonged monitoring (Holter monitor, pacemaker interrogation, or implantable loop recorder). Fine-Gray regression was used to investigate factors associated with atrial tachyarrhythmia (ATA) recurrence, with death as a competing risk. Median duration of preoperative AF was 7.8 years (interquartile range: 4.0-12.0 years), with 71% (124/174) having failed at least one prior catheter-based ablation. There were no 30-day mortalities. Freedom from ATAs was 94% (120/128), 83% (53/64), and 88% (35/40) at 1, 5, and 7 years, respectively. On regression analysis, preoperative AF duration and early postoperative ATAs were associated with late ATAs recurrence. CONCLUSION: Despite the majority of patients having a long-duration of preoperative AF and having failed at least one catheter-based ablation, the stand-alone CMP-IV had excellent late efficacy in patients with longstanding persistent AF, with low morbidity and no mortality. We recommend consideration of stand-alone CMP-IV for patients with longstanding persistent AF who have failed or are poor candidates for catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Humanos , Procedimento do Labirinto , Recidiva , Resultado do Tratamento
2.
Biochem Biophys Res Commun ; 518(4): 759-764, 2019 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-31472962

RESUMO

Intense nanosecond pulsed electric field (nsPEF) is a novel modality for cell activation and nanoelectroporation. Applications of nsPEF in research and therapy are hindered by a high electric field requirement, typically from 1 to over 50 kV/cm to elicit any bioeffects. We show how this requirement can be overcome by engaging temporal summation when pulses are compressed into high-rate bursts (up to several MHz). This approach was tested for excitation of ventricular cardiomyocytes and peripheral nerve fibers; for membrane electroporation of cardiomyocytes, CHO, and HEK cells; and for killing EL-4 cells. MHz compression of nsPEF bursts (100-1000 pulses) enables excitation at only 0.01-0.15 kV/cm and electroporation already at 0.4-0.6 kV/cm. Clear separation of excitation and electroporation thresholds allows for multiple excitation cycles without membrane disruption. The efficiency of nsPEF bursts increases with the duty cycle (by increasing either pulse duration or repetition rate) and with increasing the total time "on" (by increasing either pulse duration or number). For some endpoints, the efficiency of nsPEF bursts matches a single "long" pulse whose amplitude and duration equal the time-average amplitude and duration of the bursts. For other endpoints this rule is not valid, presumably because of nsPEF-specific bioeffects and/or possible modification of targets already during the burst. MHz compression of nsPEF bursts is a universal and efficient way to lower excitation thresholds and facilitate electroporation.


Assuntos
Potenciais de Ação/fisiologia , Permeabilidade da Membrana Celular/fisiologia , Eletroporação/métodos , Miócitos Cardíacos/fisiologia , Fibras Nervosas/fisiologia , Animais , Células CHO , Cálcio , Linhagem Celular Tumoral , Células Cultivadas , Cricetulus , Estimulação Elétrica/métodos , Células HEK293 , Humanos , Camundongos Endogâmicos DBA , Miócitos Cardíacos/citologia , Rana catesbeiana/fisiologia , Fatores de Tempo
3.
Biochim Biophys Acta ; 1848(10 Pt A): 2118-25, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26112464

RESUMO

Ca2+ activation and membrane electroporation by 10-ns and 4-ms electric pulses (nsEP and msEP) were compared in rat embryonic cardiomyocytes. The lowest electric field which triggered Ca2+ transients was expectedly higher for nsEP (36 kV/cm) than for msEP (0.09 kV/cm) but the respective doses were similar (190 and 460 mJ/g). At higher intensities, both stimuli triggered prolonged firing in quiescent cells. An increase of basal Ca2+ level by >10 nM in cells with blocked voltage-gated Ca2+ channels and depleted Ca2+ depot occurred at 63 kV/cm (nsEP) or 0.14 kV/cm (msEP) and was regarded as electroporation threshold. These electric field values were at 150-230% of stimulation thresholds for both msEP and nsEP, notwithstanding a 400,000-fold difference in pulse duration. For comparable levels of electroporative Ca2+ uptake, msEP caused at least 10-fold greater uptake of propidium than nsEP, suggesting increased yield of larger pores. Electroporation by msEP started Ca2+ entry abruptly and locally at the electrode-facing poles of cell, followed by a slow diffusion to the center. In a stark contrast, nsEP evoked a "supra-electroporation" pattern of slower but spatially uniform Ca2+ entry. Thus nsEP and msEP had comparable dose efficiency, but differed profoundly in the size and localization of electropores.


Assuntos
Permeabilidade da Membrana Celular/fisiologia , Eletroporação/métodos , Miócitos Cardíacos/fisiologia , Miócitos Cardíacos/efeitos da radiação , Propídio/farmacocinética , Animais , Permeabilidade da Membrana Celular/efeitos da radiação , Células Cultivadas , Relação Dose-Resposta à Radiação , Taxa de Depuração Metabólica/efeitos da radiação , Doses de Radiação , Ratos , Eletricidade Estática
4.
Phys Rev Lett ; 114(11): 118303, 2015 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-25839316

RESUMO

We explore the shape and the dynamics of scroll-wave filaments in excitable media with an abruptly changing diffusion tensor, important for cardiac applications. We show that, similar to a beam of light, the filament refracts at the boundary separating domains with different diffusion. We derive the laws of filament refraction and test their validity in computational experiments. We discovered that at small angles to the interface, the filament can become unstable and develop oscillations. The nature of the observed instabilities, as well as overall theoretical and experimental significance of the findings, is discussed.


Assuntos
Modelos Teóricos , Arritmias Cardíacas/fisiopatologia , Difusão , Coração/fisiologia , Modelos Cardiovasculares
5.
Artigo em Inglês | MEDLINE | ID: mdl-38908782

RESUMO

OBJECTIVE: To examine the effectiveness of a recently developed nonthermal technology, nanosecond pulse-field ablation (nsPFA), for surgical ablation of the atria in a beating heart porcine model. METHODS: Six pigs underwent sternotomy and ablation using an nsPFA parallel clamp. The ablation electrodes (53 mm long) were embedded in the jaws of the clamp. Nine lesions per pig were created in locations chosen to be representative of the Cox-maze procedure. Four lesions were intended to electrically isolate parts of the atrium: the right atrial appendage, left atrial appendage, right pulmonary veins, and left pulmonary veins. For these lesions, exit block testing was performed both after ablation and before euthanasia; the time between the 2 tests was 3.3 ± 0.5 hours (range, 2-4 hours). Using purse string sutures, 5 more lesions were created up to the superior vena cava, down to the inferior vena cava, across the right atrial free wall, and at 2 distinct locations on the left atrial free wall. The clamp delivered a train of nanosecond duration pulses, with a total duration of 2.5 seconds, independent of tissue thickness. The heart tissue was stained with 1% triphenyltetrazolium chloride after a dwelling period of 2 hours. Subsequently, each lesion was cross sectioned at 5-mm intervals to assess the ablation depth and transmurality. In some sections, transmurality could not be established on the basis of triphenyltetrazolium chloride staining alone; for these lesions, Gomori-trichrome stains were used, and the histologic sections were evaluated for transmurality. RESULTS: The ablation time was 2.5 seconds per lesion, for a total of only 22.5 seconds ablation time to create 9 lesions. A total of 53 lesions were created, resulting in 388 separate histologic sections. Transmurality was established in 386 sections (99.5%). Mean tissue thickness was 3.1 ± 1.5 mm (range, 0.2-8.6 mm). Exit block was confirmed in 23 of the 24 lesions (96%) postablation and 23 of 24 (96%) before the animals were humanely killed. Over the course of the procedure, neither pulse-induced arrhythmias nor any other complications were noted. CONCLUSIONS: The novel nsPFA clamp device was effective in creating acute conduction block and transmural lesions in both the right and left atria in an acute porcine model. This nonthermal energy source has great potential to both shorten procedural time and enable effective ablation in the beating heart.

6.
Cardiovasc Eng Technol ; 14(1): 52-59, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35705890

RESUMO

BACKGROUND: Myocardial tissue can be ablated by the application nanosecond pulsed fields (nsPEFs). The applied electric fields irreversibly permeabilize cell membranes and thereby kill myocytes while leaving the extracellular matrix intact. METHODS: In domestic pigs (n = 10), hearts were exposed via sternotomy and either ablated in vivo ([Formula: see text] = 5) or in excised, Langendorff-perfused hearts ([Formula: see text] = 5). The nsPEFs consisted of 6-36 pulses of 300 ns each, delivered at 3-6 Hz; the voltage applied varied from 10 to 12 kV. Atrial lesions were either created after inserting the bottom jaw of the bipolar clamp into the atrium via a purse string incision (2-3 lesions per atrium) or by clamping a double layer of tissue at the appendages (one lesion per atrium). Ventricular lesions were created after an incision at the apex. The transmurality of each lesion was determined at three points along the lesion using a triphenyl tetrazolium chloride (TTC) stain. RESULTS: All 27 atrial lesions were transmural. This includes 13/13 purse string lesions (39/39 sections, tissue thickness 2.5-4.5 mm) and 14/14 appendage lesions (42/42 sections, tissue thickness 8-12 mm). All 3 right ventricular lesions were transmural (9/9 sections, 18 pulses per lesion). Left ventricular lesions were always transmural for 36 pulses (3/3 lesions, 9/9 sections). All lesions have highly consistent width across the wall. There were no pulse-induced arrhythmias or other complications during the procedure. CONCLUSIONS: nsPEF ablation reliably created acute lesions in porcine atrial and ventricular myocardium. It has far better penetration and is faster than both radiofrequency ablation and cryoablation and it is free from thermal side effects.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Suínos , Animais , Ablação por Cateter/efeitos adversos , Átrios do Coração , Miocárdio/patologia , Sus scrofa
7.
Ann Thorac Surg ; 116(2): 307-313, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36935027

RESUMO

BACKGROUND: Bipolar radiofrequency (RF) clamps are commonly used during surgical ablation for atrial fibrillation (AF). This study examined the efficacy of an irrigated bipolar RF clamp to create transmural lesions in an ex vivo human heart model. METHODS: Ten donor hearts, turned down for transplantation, were explanted and arrested with cold cardioplegia. The ablations of the Cox Maze IV procedure were performed using the Cardioblate LP (Medtronic, Inc) irrigated bipolar RF clamp. In the first 5 hearts, each lesion was created with a single application of RF, whereas in the remaining 5 hearts, each lesion was created with a double application of RF without unclamping. Each lesion was cross-sectioned and stained with 2,3,5-triphenyl-tetrazolium chloride to assess ablation depth and transmurality. RESULTS: A total of 100 lesions were analyzed. In the single-ablation group, 222 of 260 sections (85%) and 37 of 50 lesions (74%) were transmural. The efficacy improved significantly in the double-ablation group, in which 348 of 359 sections (97%, P < .001) and 46 of 50 lesions (92%, P = .017) were transmural. Overall, in nontransmural lesions, the epicardial fat thickness was significantly greater (1.69 ± 0.70 mm vs 0.45 ±0.10 mm, P < .001) than the transmural lesions. CONCLUSIONS: A single ablation on human atrial tissue with an irrigated bipolar RF clamp was insufficient to reliably create transmural lesions, but a double ablation significantly increased the lesion and section transmurality. Nontransmural lesions were associated with significantly thicker layers of epicardial fat, which likely decreased tissue energy delivery due to the higher resistance of fat to current flow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Transplante de Coração , Ablação por Radiofrequência , Humanos , Ablação por Cateter/métodos , Doadores de Tecidos , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia
8.
Innovations (Phila) ; 18(6): 565-573, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38013234

RESUMO

OBJECTIVE: A right minithoracotomy (RMT) is a minimally invasive surgical approach that has been increasingly performed for the concomitant Cox maze IV procedure (CMP) and mitral valve surgery (MVS). Little is known regarding whether long-term rhythm and survival outcomes are affected by the RMT as compared with the traditional median sternotomy (MS) approach. METHODS: Between April 2004 and April 2021, 377 patients underwent the concomitant CMP and MVS, of whom 38% had RMT. Propensity score matching yielded 116 pairs. Freedom from atrial tachyarrhythmias (ATA) was assessed with prolonged monitoring annually for 8 years. Survival, rhythm, and perioperative outcomes were compared. RESULTS: The unmatched RMT cohort had a greater freedom from ATA recurrence at 1 year (99% vs 90%, P = 0.001) and 3 years (94% vs 86%, P = 0.045). The matched RMT cohort had longer cardiopulmonary bypass (median: 215 [199 to 253] vs 170 [136 to 198] min, P < 0.001) and aortic cross-clamp (110 [98 to 124] vs 86 [71 to 102] min, P < 0.001) times but shorter intensive care time (48 [24 to 95] vs 71 [26 to 144] h, P = 0.001) and length of stay (8 [6 to 11] vs 10 [7 to 14] h, P < 0.001). More pacemakers (18% vs 4%, P < 0.001) and postoperative transfusions (57% vs 41%, P = 0.014) occurred in the MS cohort. The 30-day mortality (P = 0.651) and 8-year survival (P = 0.072) was not significantly different between the cohorts. CONCLUSIONS: Early 1-year and 3-year freedom from ATA recurrence was better in the RMT cohort compared with the MS cohort. Despite longer operative times, the RMT cohort had shorter lengths of stay, fewer postoperative transfusions, and fewer pacemakers placed.


Assuntos
Valva Mitral , Esternotomia , Humanos , Esternotomia/métodos , Valva Mitral/cirurgia , Procedimento do Labirinto , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
9.
JTCVS Open ; 16: 292-302, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204711

RESUMO

Objectives: The mechanism by which mitral valve (MV) disease leads to atrial fibrillation (AF) remains poorly understood. Delayed-enhancement cardiac magnetic resonance imaging (DE-MRI) has been used to assess left atrial (LA) fibrosis in patients with lone AF before catheter ablation; however, few studies have used DE-MRI to assess MV-induced LA fibrosis in patients with or without AF undergoing MV surgery. Methods: Between March 2018 and September 2022, 38 subjects were enrolled; 15 age-matched controls, 14 patients with lone mitral regurgitation (MR), and 9 patients with MR and AF (MR + AF). Indexed LA volume, total LA wall, and regional LA posterior wall (LAPW) enhancement were defined by the DE-MRI. One-way analysis of variance was performed. Results: LA volume and LA enhancement were associated (r = 0.451, P = .004). LA volume differed significantly between controls (37.1 ± 10.6 mL) and patients with lone MR (71.0 ± 35.9, P = .020 and controls and patients with MR + AF (99.3 ± 47.4, P < .001). The difference in LA enhancement was significant between MR + AF (16.7 ± 9.6%) versus controls (8.3 ± 3.9%, P = .006) and MR + AF versus lone MR (8.0 ± 4.8%, P = .004). Similarly, the was significantly more LAPW enhancement in the MR + AF (17.5 ± 8.7%) versus control (9.2 ± 5.1%, P = .011) and MR + AF versus lone MR (9.8 ± 6.0%, P = .020). Conclusions: Patients with MR + AF had significantly more total and LAPW fibrosis compared with both controls and lone MR. Volume and delayed enhancement were associated, but there was no difference between MR and MR + AF.

10.
JTCVS Tech ; 20: 58-70, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37555041

RESUMO

Objective: To develop a minimally invasive, reproducible model of chronic severe mitral regurgitation (MR) that replicates the clinical phenotype of left atrial (LA) and left ventricular dilation and susceptibility to atrial fibrillation. Methods: Under transesophageal echocardiographic guidance, chordae tendinae were avulsed using endovascular forceps until the ratio of regurgitant jet area to LA area was ≥70%. Animals survived for an average of 8.6 ± 1.6 months (standard deviation) and imaged with monthly transthoracic echocardiography (TTE). Animals underwent baseline and preterminal magnetic resonance imaging. Terminal studies included TTE, transesophageal echocardiography, and rapid atrial pacing to test inducibility of atrial tachyarrhythmias. Results: Eight dogs underwent creation of severe MR and interval monitoring. Two were excluded-one died from acute heart failure, and the other had resolution of MR. Six dogs underwent the full experimental protocol; only one required medical management of clinical heart failure. MR remained severe over time, with a mean terminal regurgitant jet area to LA area of 71 ± 14% (standard deviation) and regurgitant fraction of 52 ± 11%. Mean LA volume increased over 130% (TTE: 163 ± 147%, P = .039; magnetic resonance imaging: 132 ± 54%, P = .011). Mean left ventricular end-diastolic volume increased by 38 ± 21% (P = .008). Inducible atrial tachyarrhythmias were seen in 4 of 6 animals at terminal surgery, and none at baseline. Conclusions: Within the 6 dogs that successfully completed the full experimental protocol, this model replicated the clinical phenotype of severe MR, which led to marked structural and electrophysiologic cardiac remodeling. This model allowed for precise measurements at repeated time points and will facilitate future studies to elucidate the mechanisms of atrial and ventricular remodeling secondary to MR and the pathophysiology of valvular atrial fibrillation.

11.
Phys Rev Lett ; 109(3): 038303, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861905

RESUMO

Anchoring of spiral and scroll waves in excitable media has attracted considerable interest in the context of cardiac arrhythmias. Here, by bombarding inclusions with drifting spiral and scroll waves, we explore the forces exerted by inclusions onto an approaching spiral and derive the equations of motion governing spiral dynamics in the vicinity of inclusion. We demonstrate that these forces nonmonotonically depend on distance and can lead to complex behavior: (a) anchoring to small but circumnavigating larger inclusions; (b) chirality-dependent anchoring.


Assuntos
Modelos Teóricos , Simulação por Computador , Fenômenos Eletrofisiológicos , Coração/fisiologia , Modelos Cardiovasculares
12.
Innovations (Phila) ; 17(5): 409-415, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36217760

RESUMO

OBJECTIVE: Expert consensus guidelines recommend surgical ablation (SA) for patients with symptomatic atrial fibrillation (AF), but less than half of patients with AF undergoing cardiac procedures receive concomitant SA. Complete isolation of the left atrial posterior wall (LAPW) has been shown to be the most critical part of the Cox maze procedure. The purpose of this study was to investigate the performance of a novel radiofrequency (RF) bipolar device, EnCompass™ (AtriCure, Inc., Mason, OH, USA), designed to isolate the LAPW in a single application. METHODS: Five adult pigs underwent SA in a beating heart model. After a single ablation, the heart was arrested, explanted, and stained with triphenyl-tetrazolium-chloride for histological assessment. Each lesion was sectioned, and the ablation depth, muscle, and fat thickness were determined. The lesion width, energy delivery, and ablation times were compared with those from a reference RF clamp (Synergy™, AtriCure). RESULTS: Transmurality was documented in 100% of lesions (5 of 5) and cross sections (160 of 160). Electrical isolation was documented in every instance. There was no evidence of clot, charring, or pulmonary vein stenosis. Compared with the reference clamp, the lesions created by the EnCompass™ clamp were 1.5 times wider on average. The average energy delivered was 5 times higher over a duration that was 4.5 times longer due to the increased volume of tissue ablated. CONCLUSIONS: The EnCompass™ clamp reproducibly created transmural isolation of the LAPW with a single application. This may allow for simplification of the SA strategy and increased adoption of AF treatment during concomitant surgery.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Suínos , Animais , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Resultado do Tratamento
13.
Artigo em Inglês | MEDLINE | ID: mdl-36642681

RESUMO

OBJECTIVE: The Cox-Maze IV procedure (CMP-IV) is the most effective treatment for atrial fibrillation. Increased left atrial (LA) size has been identified as a risk factor for failure to restore sinus rhythm. This has biased many surgeons against ablation in patients with giant left atrium (GLA), defined as LA diameter >6.5 cm. In this study we aimed to define the efficacy of the CMP-IV in patients with GLA. METHODS: From April 2004 through March 2020, 786 patients with a documented LA diameter underwent elective CMP-IV, 72 of whom had GLA. Median follow-up duration was 4 years (interquartile range, 1-7 years). Recurrence was defined as any documented atrial tachyarrhythmia (ATA) lasting 30 seconds. ATA recurrence and survival were analyzed across GLA versus non-GLA groups. RESULTS: Median age at surgery was 65 (interquartile range, 56-73) years. Median LA diameter within the GLA group was 7.0 (range, 6.6-10.0) cm. There were no differences in rates of postoperative complications for the 2 groups, including rate of postoperative stroke and pacemaker placement (GLA 14%; non-GLA 12%; P = .682). A trend toward increased 30-day mortality in the GLA group did not reach statistical significance (GLA 6%; non-GLA 2%; P = .051). Freedom from ATAs at 5 years postoperatively was comparable for the 2 groups (GLA 82%; non-GLA 84%). CONCLUSIONS: The CMP-IV had good efficacy in patients with GLA. Our results suggest that LA diameter >6.5 cm should not preclude a patient from undergoing surgical ablation for atrial fibrillation.

14.
Bioelectrochemistry ; 141: 107882, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34274877

RESUMO

While electrical stimulation with pulses of milli- or microsecond duration is possible without electroporation, stimulation with nanosecond pulses typically entails electroporation, and nanosecond pulses can even cause electroporation without stimulation. A recently proposed explanation for this intriguing finding is that stimulation requires not only that a threshold membrane potential is reached, but also that it is sustained for a certain time tmin, while electroporation occurs almost immediately after a higher threshold potential is reached. Here we analytically derive stimulation and electroporation thresholds for membranes that satisfy these assumptions. We analyze the safety factor, i.e. the ratio between electroporation and stimulation threshold and its dependence on pulse duration, membrane charging time constant, and tmin. We find that the safety factor is sharply reduced if both the pulse duration and the membrane charging time constant are below tmin. We discuss different approaches to get models with varying tmin that could be used to experimentally test this theory and cardiac applications.


Assuntos
Estimulação Elétrica , Eletroporação/métodos , Modelos Teóricos , Reprodutibilidade dos Testes , Segurança , Tempo
15.
PLoS One ; 16(9): e0257287, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34559811

RESUMO

AIMS: Recently, a new defibrillation modality using nanosecond pulses was shown to be effective at much lower energies than conventional 10 millisecond monophasic shocks in ex vivo experiments. Here we compare the safety factors of 300 nanosecond and 10 millisecond shocks to assess the safety of nanosecond defibrillation. METHODS AND RESULTS: The safety factor, i.e. the ratio of median effective doses (ED50) for electroporative damage and defibrillation, was assessed for nanosecond and conventional (millisecond) defibrillation shocks in Langendorff-perfused New Zealand white rabbit hearts. In order to allow for multiple shock applications in a single heart, a pair of needle electrodes was used to apply shocks of varying voltage. Propidium iodide (PI) staining at the surface of the heart showed that nanosecond shocks had a slightly lower safety factor (6.50) than millisecond shocks (8.69), p = 0.02; while PI staining cross-sections in the electrode plane showed no significant difference (5.38 for 300 ns shocks and 6.29 for 10 ms shocks, p = 0.22). CONCLUSIONS: In Langendorff-perfused rabbit hearts, nanosecond defibrillation has a similar safety factor as millisecond defibrillation, between 5 and 9, suggesting that nanosecond defibrillation can be performed safely.


Assuntos
Eletroporação/métodos , Coração/fisiologia , Preparação de Coração Isolado/métodos , Animais , Cardioversão Elétrica/métodos , Eletrodos , Eletrofisiologia , Feminino , Masculino , Propídio , Coelhos , Segurança , Fibrilação Ventricular
16.
Bioelectrochemistry ; 140: 107811, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33862549

RESUMO

Exposures to short-duration, strong electric field pulses have been utilized for stimulation, ablation, and the delivery of molecules into cells. Ultrashort, nanosecond duration pulses have shown unique benefits, but they require higher field strengths. One way to overcome this requirement is to use trains of nanosecond pulses with high repetition rates, up to the MHz range. Here we present a theoretical model to describe the effects of pulse trains on the plasma membrane and intracellular membranes modeled as resistively charged capacitors. We derive the induced membrane potential and the stimulation threshold as functions of pulse number, pulse duration, and repetition rate. This derivation provides a straightforward method to calculate the membrane charging time constant from experimental data. The derived excitation threshold agrees with nerve stimulation experiments, indicating that nanosecond pulses are not more effective than longer pulses in charging nerve fibers. The derived excitation threshold does not, however, correctly predict the nanosecond stimulation of cardiomyocytes. We show that a better agreement is possible if multiple charging time constants are considered. Finally, we expand the model to intracellular membranes and show that pulse trains do not lead to charge buildup, but can create significant oscillations of the intracellular membrane potential.


Assuntos
Estimulação Elétrica , Eletroporação , Animais , Cálcio/metabolismo , Membrana Celular/metabolismo , Permeabilidade da Membrana Celular , Modelos Biológicos , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo
17.
Biophys J ; 99(7): 2058-66, 2010 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-20923639

RESUMO

Despite major successes of biophysical theories in predicting the effects of electrical shocks within the heart, recent optical mapping studies have revealed two major discrepancies between theory and experiment: 1), the presence of negative bulk polarization recorded during strong shocks; and 2), the unexpectedly small surface polarization under shock electrodes. There is little consensus as to whether these differences result from deficiencies of experimental techniques, artifacts of tissue damage, or deficiencies of existing theories. Here, we take advantage of recently developed near-infrared voltage-sensitive dyes and transillumination optical imaging to perform, for the first time that we know of, noninvasive probing of field effects deep inside the intact ventricular wall. This technique removes some of the limitations encountered in previous experimental studies. We explicitly demonstrate that deep inside intact myocardial tissue preparations, strong electrical shocks do produce considerable negative bulk polarization previously inferred from surface recordings. We also demonstrate that near-threshold diastolic field stimulation produces activation of deep myocardial layers 2-6 mm away from the cathodal surface, contrary to theory. Using bidomain simulations we explore factors that may improve the agreement between theory and experiment. We show that the inclusion of negative asymmetric current can qualitatively explain negative bulk polarization in a discontinuous bidomain model.


Assuntos
Polarização de Fluorescência/métodos , Ventrículos do Coração/anatomia & histologia , Transiluminação/métodos , Potenciais de Ação/fisiologia , Animais , Simulação por Computador , Diástole/fisiologia , Especificidade de Órgãos , Sus scrofa , Função Ventricular/fisiologia
18.
J Mol Cell Cardiol ; 48(1): 238-45, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19486903

RESUMO

While ventricular gap junctions contain only Cx43, atrial gap junctions contain both Cx40 and Cx43; yet the functional consequences of this co-expression remain poorly understood. We quantitated the expression of Cx40 and Cx43 and their contributions to atrial gap junctional conductance (g(j)). Neonatal murine atrial myocytes showed similar abundances of Cx40 and Cx43 proteins, while ventricular myocytes contained at least 20 times more Cx43 than Cx40. Since Cx40 gap junction channels are blocked by 2 mM spermine while Cx43 channels are unaffected, we used spermine block as a functional dual whole cell patch clamp assay to determine Cx40 contributions to cardiac g(j). Slightly more than half of atrial g(j) and

Assuntos
Conexina 43/metabolismo , Conexinas/metabolismo , Junções Comunicantes/metabolismo , Átrios do Coração/citologia , Canais Iônicos/metabolismo , Miócitos Cardíacos/metabolismo , Animais , Animais Recém-Nascidos , Linhagem Celular , Células Cultivadas , Eletrofisiologia , Immunoblotting , Imuno-Histoquímica , Canais Iônicos/antagonistas & inibidores , Camundongos , Camundongos Endogâmicos C57BL , Microscopia de Fluorescência , Miócitos Cardíacos/efeitos dos fármacos , Reação em Cadeia da Polimerase , Espermina/farmacologia
19.
Physica D ; 238(11-12): 969-975, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20160895

RESUMO

Most commonly, atrial fibrillation is triggered by rapid bursts of electrical impulses originating in the myocardial sleeves of pulmonary veins (PVs). However, the nature of such bursts remains poorly understood. Here, we propose a mechanism of bursting consistent with the extensive empirical information about the electrophysiology of the PVs. The mechanism is essentially non-local and involves the spontaneous initiation of non-sustained spiral waves in the distal end of the muscle sleeves of the PVs. It reproduces the experimentally observed dynamics of the bursts, including their frequency, their intermittent character, and the unusual shape of the electrical signals in the pulmonary veins that are reminiscent of so-called early afterdepolarizations (EADs).

20.
Cardiovasc Res ; 79(3): 416-26, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18430749

RESUMO

AIMS: Rotigaptide is proposed to exert its anti-arrhythmic effects by improving myocardial gap-junction communication. To directly investigate the mechanisms of rotigaptide action, we treated cultured neonatal murine ventricular cardiomyocytes with clinical pharmacological doses of rotigaptide and directly determined its effects on gap-junctional currents. METHODS AND RESULTS: Neonatal murine ventricular cardiomyocytes were enzymatically isolated and cultured for 1-4 days. Primary culture cell pairs were subjected to dual whole cell patch-clamp procedures to directly measure gap-junctional currents (I(j)) and voltage (V(j)). Rotigaptide (0-350 nM) was applied overnight or acutely perfused into 35 mm culture dishes. Rotigaptide (35-100 nM) acutely and chronically increased the resting gap-junction conductance (g(j)), and normalized steady-state minimum g(j) (G(min)) by 5-20%. Higher concentrations produced a diminishing response, which mimics the observed therapeutic efficacy of the drug. The inactivation kinetics was similarly slowed in a therapeutic concentration-dependent manner without affecting the V(j) dependence of inactivation or recovery. The effects of 0-100 nM rotigaptide on ventricular g(j) during cardiac action potential propagation were accurately modelled by computer simulations which demonstrate that clinically effective concentrations of rotigaptide can partially reverse conduction slowing due to decreases in g(j) and inactivation. CONCLUSION: These results demonstrate that therapeutic concentrations of rotigaptide increase the resting gap-junction conductance and reduce the magnitude and kinetics of steady-state inactivation in a concentration-dependent manner. Rotigaptide may be effective in treating re-entrant forms of cardiac arrhythmias by improving conduction and preventing the formation of re-entrant circuits in partially uncoupled myocardium.


Assuntos
Antiarrítmicos/farmacologia , Comunicação Celular/efeitos dos fármacos , Junções Comunicantes/efeitos dos fármacos , Miócitos Cardíacos/efeitos dos fármacos , Oligopeptídeos/farmacologia , Potenciais de Ação , Animais , Animais Recém-Nascidos , Células Cultivadas , Simulação por Computador , Relação Dose-Resposta a Droga , Junções Comunicantes/metabolismo , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/metabolismo , Cinética , Camundongos , Camundongos Endogâmicos C57BL , Modelos Cardiovasculares , Miócitos Cardíacos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA