Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Thromb Thrombolysis ; 45(2): 225-233, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29170875

RESUMO

The long-term pharmacodynamic effects of Ticagrelor versus Clopidogrel in patients undergoing early percutaneous coronary intervention (PCI) after fibrinolytic therapy is unknown. From May 2014 to August 2016, 212 patients undergoing PCI within 24 h of Tenecteplase (TNK), Aspirin, and Clopidogrel for ST-elevated myocardial infarction (STEMI) were randomized at four Canadian sites to receive additional Clopidogrel or Ticagrelor initiated prior to PCI. The platelet reactivity units (PRU) were measured with the VerifyNow Assay before study drug administration (baseline), at 4 and 24 h post PCI, and follow-up appointment. A mixed-model analysis with time as the repeated measure and drug as the between-subjects factor was calculated using 2 separate 1 × 4 ANOVAs, with students t-tests used to compare drugs within each time point. Complete clinical follow-up data (median 115.0 days; IQR 80.3-168.8) was available in 50 patients (23.6%) randomized to either Clopidogrel (n = 23) or Ticagrelor (n = 27). Analyses revealed significant decreases in PRU from baseline to 4 h (261.4 vs. 71.7; Mdiff = - 189.7; p < 0.001) to 24 h (71.7 vs. 27.7; Mdiff = - 44.0; p < 0.001) to end of follow-up (27.7 vs.17.9; Mdiff = - 9.9. p = 0.016) for those randomized to Ticagrelor and significant decreases in PRU only from baseline to 4 h (271.3 vs. 200.8; Mdiff = - 70.5, p = < 0.001) in patients receiving Clopidogrel, and a significantly greater proportion of patients with adequate platelet inhibition (PRU < 208) on long-term follow-up (Clopidogrel, 82.6% vs. Ticagrelor, 100.0%; p = 0.038). Our results demonstrate that in patients undergoing PCI within 24 h of fibrinolysis for STEMI, Ticagrelor provides prolonged platelet inhibition compared with Clopidogrel.


Assuntos
Adenosina/análogos & derivados , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Ticlopidina/análogos & derivados , Adenosina/farmacocinética , Idoso , Clopidogrel , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/farmacocinética , Terapia Trombolítica , Ticagrelor , Ticlopidina/farmacocinética , Fatores de Tempo , Resultado do Tratamento
2.
Am Heart J ; 192: 105-112, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28938956

RESUMO

OBJECTIVES: Patients undergoing PCI early after fibrinolytic therapy are at high risk for both thrombotic and bleeding complications. We sought to assess the pharmacodynamic effects of ticagrelor versus clopidogrel in the fibrinolytic-treated STEMI patients undergoing early PCI. METHODS AND RESULTS: Patients undergoing PCI within 24 hours of tenecteplase (TNK), aspirin, and clopidogrel for STEMI were randomized to receive additional clopidogrel 300 mg followed by 75 mg daily or ticagrelor 180 mg followed by 90 mg twice daily. The platelet reactivity units (PRU) were measured with the VerifyNow Assay before study drug administration (baseline) at 4 and 24 hours post-PCI. The primary end point was PRU ≤208 at 4 hours. A total of 140 patients (74 in ticagrelor and 66 in clopidogrel group) were enrolled. The mean PRU values at baseline were similar for the 2 groups (257.8±52.9 vs 259.5±56.7, P=.85, respectively). Post-PCI, patients on ticagrelor, compared to those on clopidogrel, had significantly lower PRU at 4 hours (78.7±88 vs 193.6±86.5, respectively, P<.001) and at 24 hours (34.5±35.0 and 153.5±75.5, respectively, P<.001). The primary end point was observed in 87.8% (n=65) in the ticagrelor-treated patients compared to 57.6% (n=38) of clopidogrel-treated patients, P<.001. CONCLUSION: Fibrinolysis-treated STEMI patients who received clopidogrel and aspirin at the time of fibrinolysis and were undergoing early PCI frequently had PRU >208. In this high-risk population, ticagrelor provides more prompt and potent platelet inhibition compared with clopidogrel (Funded by Astra Zeneca; NCT01930591, https://clinicaltrials.gov/ct2/show/NCT01930591).


Assuntos
Adenosina/análogos & derivados , Plaquetas/efeitos dos fármacos , Intervenção Coronária Percutânea , Ativação Plaquetária/efeitos dos fármacos , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Terapia Trombolítica/métodos , Ticlopidina/análogos & derivados , Adenosina/administração & dosagem , Clopidogrel , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Cuidados Pré-Operatórios/métodos , Prognóstico , Estudos Prospectivos , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Ticagrelor , Ticlopidina/administração & dosagem , Fatores de Tempo
3.
Circ Cardiovasc Interv ; 16(5): e012892, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37125538

RESUMO

BACKGROUND: Deciphering which patients with low-gradient aortic valve disease have severe stenosis can be difficult. We aimed to correlate the postextrasystolic potentiation (PESP) with dobutamine stress echocardiography and multidetector computed tomography in patients with low-gradient aortic valve stenosis. METHODS: Patients with an aortic valve area ≤1 cm2 and a mean gradient <40 mm Hg were included. Aortic valve stenosis severity was assessed by a core lab with dobutamine stress echocardiography, followed by a multidetector computed tomography aortic valve score if indeterminate. A premature ventricular contraction was induced by intentional catheter contact with the myocardium within the left ventricle. PESP was calculated as a percent change of pre-to-post mean gradient. Multidetector computed tomography was used to measure the aortic valve calcification score, and subsequently, aortic valve calcification density. RESULTS: Twenty-eight patients (age, 77±10 years; 19 female) were included. Dobutamine stress echocardiography increased mean gradient from baseline of 25±7 mm Hg to 36±11 mm Hg; pre-premature ventricular contraction mean gradient was 25±7 mm Hg and increased to post-premature ventricular contraction mean gradient of 32±10 mm Hg, representing a PESP of 24±11%. A ≥20% in PESP resulted in 100% sensitivity, 77% specificity, 83% positive predictive value, and 100% negative predictive value for diagnosing severe aortic valve stenosis. There was a significant correlation between PESP and projected aortic valve area and aortic valve calcification density (R=-0.64, P=0.0003; R=0.057, P=0.014, respectively). CONCLUSIONS: In patients with low-gradient aortic valve stenosis, catheter-induced premature ventricular contractions during cardiac catheterization causing ≥20% PESP has a 100% sensitivity for severe aortic valve stenosis. Validation of this 20% cutoff in larger groups with correlation to clinical end points is required.


Assuntos
Estenose da Valva Aórtica , Complexos Ventriculares Prematuros , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Catéteres , Índice de Gravidade de Doença , Volume Sistólico
4.
CJC Open ; 3(9): 1125-1131, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33997751

RESUMO

BACKGROUND: As a result of the COVID-19 pandemic first wave, reductions in ST-elevation myocardial infarction (STEMI) invasive care, ranging from 23% to 76%, have been reported from various countries. Whether this change had any impact on coronary angiography (CA) volume or on mechanical support device use for STEMI and post-STEMI mechanical complications in Canada is unknown. METHODS: We administered a Canada-wide survey to all cardiac catheterization laboratory directors, seeking the volume of CA use for STEMI performed during the period from March 1 2020 to May 31, 2020 (pandemic period), and during 2 control periods (March 1, 2019 to May 31, 2019 and March 1, 2018 to May 31, 2018). The number of left ventricular support devices used, as well as the number of ventricular septal defects and papillary muscle rupture cases diagnosed, was also recorded. We also assessed whether the number of COVID-19 cases recorded in each province was associated with STEMI-related CA volume. RESULTS: A total of 41 of 42 Canadian catheterization laboratories (98%) provided data. There was a modest but statistically significant 16% reduction (incidence rate ratio [IRR] 0.84; 95% confidence interval 0.80-0.87) in CA for STEMI during the first wave of the pandemic, compared to control periods. IRR was not associated with provincial COVID-19 caseload. We observed a 26% reduction (IRR 0.74; 95% confidence interval 0.61-0.89) in the use of intra-aortic balloon pump use for STEMI. Use of an Impella pump and mechanical complications from STEMI were exceedingly rare. CONCLUSIONS: We observed a modest 16% decrease in use of CA for STEMI during the pandemic first wave in Canada, lower than the level reported in other countries. Provincial COVID-19 caseload did not influence this reduction.


INTRODUCTION: Après la première vague de la pandémie de COVID-19, de nombreux pays ont déclaré une réduction de 23 % à 76 % des soins invasifs de l'infarctus du myocarde avec élévation du segment ST (STEMI). On ignore si ce changement a entraîné des répercussions sur le volume d'angiographies coronariennes (AC) ou sur l'utilisation des dispositifs d'assistance mécanique lors de STEMI et des complications mécaniques post-STEMI au Canada. MÉTHODES: Nous avons réalisé un sondage pancanadien auprès de tous les directeurs de laboratoire de cathétérisme cardiaque pour obtenir le volume d'utilisation des AC lors des STEMI réalisées durant la période du 1er mars 2020 au 31 mai 2020 (période de pandémie) et durant 2 périodes témoins (1er mars 2019 au 31 mai 2019 et 1er mars 2018 au 31 mai 2018). Le nombre de dispositifs d'assistance ventriculaire gauche utilisés et le nombre de cas de communications interventriculaires et de ruptures du muscle papillaire diagnostiqués ont également été enregistrés. Nous avons aussi évalué si le nombre de cas de COVID-19 enregistrés dans chaque province était associé au volume d'AC liées aux STEMI. RÉSULTATS: Au total, 41 des 42 laboratoires canadiens de cathétérisme (98 %) ont fourni des données. Lors de la comparaison de la première vague de la pandémie aux périodes témoins, nous avons noté une réduction modeste, mais significative, sur le plan statistique de 16 % (ratio du taux d'incidence [RTI] 0,84; intervalle de confiance à 95 % 0,80-0,87) des AC lors de STEMI. Le RTI n'était pas associé au nombre provincial de cas de COVID-19. Nous avons observé une réduction de 26 % (RTI 0,74; intervalle de confiance à 95 % 0,61-0,89) de l'utilisation de pompes à ballonnet intra-aortique lors de STEMI. L'utilisation d'une pompe Impella et les complications mécaniques après les STEMI étaient extrêmement rares. CONCLUSIONS: Nous avons observé une diminution modeste de 16 % de l'utilisation des AC lors de STEMI durant la première vague de la pandémie au Canada, soit une diminution plus faible que ce que les autres pays ont signalé. Le nombre provincial de cas de COVID-19 n'a pas influencé cette réduction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA