Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Neth Heart J ; 29(7-8): 394-401, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33675521

RESUMO

INTRODUCTION: Circulatory extracorporeal life support (ECLS) has been performed at the University Medical Centre Utrecht for 12 years. During this time, case mix, indications, ECLS set-ups and outcomes seem to have substantially changed. We set out to describe these characteristics and their evolution over time. METHODS: All patients receiving circulatory ECLS between 2007 and 2018 were retrospectively identified and divided into six groups according to a 2-year period of time corresponding to the date of ECLS initiation. General characteristics plus data pertaining to comorbidities, indications and technical details of ECLS commencement as well as in-hospital, 30-day, 1­year and overall mortality were collected. Temporal trends in these characteristics were examined. RESULTS: A total of 347 circulatory ECLS runs were performed in 289 patients. The number of patients and ECLS runs increased from 8 till a maximum of 40 runs a year. The distribution of circulatory ECLS indications shifted from predominantly postcardiotomy to a wider set of indications. The proportion of peripheral insertions with or without application of left ventricular unloading techniques substantially increased, while in-hospital, 30-day, 1­year and overall mortality decreased over time. CONCLUSION: Circulatory ECLS was increasingly applied at the University Medical Centre Utrecht. Over time, indications as well as treatment goals broadened, and cannulation techniques shifted from central to mainly peripheral approaches. Meanwhile, weaning success increased and mortality rates diminished.

3.
Br J Anaesth ; 116(6): 750-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27199309

RESUMO

The validity of each new cardiac output (CO) monitor should be established before implementation in clinical practice. For this purpose, method comparison studies investigate the accuracy and precision against a reference technique. With the emergence of continuous CO monitors, the ability to detect changes in CO, in addition to its absolute value, has gained interest. Therefore, method comparison studies increasingly include assessment of trending ability in the data analysis. A number of methodological challenges arise in method comparison research with respect to the application of Bland-Altman and trending analysis. Failure to face these methodological challenges will lead to misinterpretation and erroneous conclusions. We therefore review the basic principles and pitfalls of Bland-Altman analysis in method comparison studies concerning new CO monitors. In addition, the concept of clinical concordance is introduced to evaluate trending ability from a clinical perspective. The primary scope of this review is to provide a complete overview of the pitfalls in CO method comparison research, whereas other publications focused on a single aspect of the study design or data analysis. This leads to a stepwise approach and checklist for a complete data analysis and data representation.


Assuntos
Débito Cardíaco/fisiologia , Monitorização Intraoperatória/métodos , Humanos , Reprodutibilidade dos Testes
4.
J Clin Monit Comput ; 30(4): 481-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26227160

RESUMO

Uncalibrated arterial waveform analysis enables dynamic preload assessment in a minimally invasive fashion. Evidence about the validity of the technique in patients with impaired left ventricular function is scarce, while adequate cardiac preload assessment would be of great value in these patients. The aim of this study was to investigate the diagnostic accuracy of stroke volume variation (SVV) measured with the FloTrac/Vigileo™ system in patients with impaired left ventricular function. In this prospective, observational study, 22 patients with a left ventricular ejection fraction of 40 % or less undergoing elective coronary artery bypass grafting were included. Patients were considered fluid responsive if cardiac output increased with 15 % or more after volume loading (7 ml kg(-1) ideal body weight). The following variables were calculated: area under the receiver operating characteristics (ROC) curve, ideal cut-off value for SVV, sensitivity, specificity, positive and negative predictive values, and overall accuracy. In addition, SVV cut-off points to obtain 90 % true positive and 90 % true negative predictions were determined. ROC analysis revealed an area under the curve of 0.70 [0.47; 0.92]. The ideal SVV cut-off value was 10 %, with a corresponding sensitivity and specificity of 56 and 69 % respectively. Overall accuracy was 64 %, positive and negative predictive values were 69 and 56 % respectively. SVV values to obtain more than 90 % true positive and negative predictions were 16 and 6 % respectively. The ability of uncalibrated arterial waveform analysis SVV to predict fluid responsiveness in patients with impaired LVF was low.


Assuntos
Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária , Feminino , Hidratação , Testes de Função Cardíaca/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Onda de Pulso/estatística & dados numéricos , Curva ROC
5.
Neth Heart J ; 23(3): 168-73, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25475514

RESUMO

Postoperative new-onset atrial fibrillation (PNAF) is very common after cardiac surgery and postoperative inflammation may contribute to PNAF by inducing atrial dysfunction. Corticosteroids reduce inflammation and may thus reduce atrial dysfunction and PNAF development. This study aimed to determine whether dexamethasone protects against left atrial dysfunction and PNAF in cardiac surgical patients. Cardiac surgical patients were randomised to a single dose of dexamethasone (1 mg.kg(-1)) or placebo after inducing anaesthesia. Transoesophageal echocardiography was performed in patients before and after surgery. Primary outcome was left atrial total ejection fraction (LA-TEF) after sternal closure; secondary outcomes included left atrial diameter and PNAF. 62 patients were included. Baseline characteristics were well balanced. Postoperative LA-TEF was 36.4 % in the dexamethasone group and 40.2 % in the placebo group (difference -3.8 %; 95 % confidence interval (CI) -9.0 to 1.4 %; P = 0.15). Postoperative left atrial diameter was 4.6 and 4.3 cm, respectively (difference 0.3; 95 % CI -0.2 to 0.7; P = 0.19). The incidence of PNAF was 30 % in the dexamethasone group and 39 % in the placebo group (P = 0.47). Intraoperative high-dose dexamethasone did not protect against postoperative left atrial dysfunction and did not reduce the risk of PNAF in cardiac surgical patients.

6.
Br J Anaesth ; 105(2): 131-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20538739

RESUMO

BACKGROUND: Epiaortic ultrasound scanning (EUS) is regarded as the reference standard for detecting atherosclerosis in the ascending aorta (AA). Combined with appropriate surgical modifications, EUS use can significantly reduce the incidence of postoperative stroke when detecting severe AA atherosclerosis. A recently introduced modification of conventional transoesophageal echocardiography (TOE), known as the A-View method, has proven capable of inspecting the distal AA. The objective of this study was to quantify the diagnostic accuracy of modified TOE in assessing atherosclerosis of the distal AA. METHODS: After approval by the institutional medical ethical committee and after obtaining written informed consent, 465 consecutive patients above 65 yr old, undergoing elective cardiac surgery with a median sternotomy, were included. The study followed a cross-sectional diagnostic design. All consecutive patients underwent modified TOE followed by EUS (reference standard) to assess the severity of distal AA atherosclerosis. We constructed contingency tables to compare the presence (and severity) of atherosclerosis, detected by the two techniques. RESULTS: The positive predictive value of modified TOE for the detection of clinically significant atherosclerosis was 67%, and the negative predictive value was 97%. The sensitivity was 95% and the specificity was 79%. One patient suffered a pulmonary haemorrhage, although he recovered without further sequelae. We did not observe any clinical significant haemodynamic or ventilatory effects. CONCLUSIONS: The high negative predictive value and sensitivity show that modified TOE yields adequate diagnostic accuracy for excluding clinically relevant aorta atherosclerosis without significant cardiopulmonary side-effects, provided that the A-View catheter is introduced carefully.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Aterosclerose/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Transesofagiana/efeitos adversos , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Esterno/cirurgia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
8.
Acta Anaesthesiol Scand ; 52(1): 65-72, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17976224

RESUMO

BACKGROUND: Pulmonary hypertension (PHT) is common in patients undergoing mitral valve surgery and is an independent risk factor for the development of acute right ventricular (RV) failure. Inhaled iloprost was shown to improve RV function and decrease RV afterload in patients with primary PHT. However, no randomized-controlled trials on the intraoperative use of iloprost in cardiac surgical patients are available. We therefore compared the effects of inhaled iloprost vs. intravenous standard therapy in cardiac surgical patients with chronic PHT. METHODS: Twenty patients with chronic PHT undergoing mitral valve repair were randomized to receive inhaled iloprost (25 microg) or intravenous nitroglycerine. Iloprost was administered during weaning from cardiopulmonary bypass (CPB). Systemic and pulmonary haemodynamics were assessed with pulmonary artery catheterization and transoesophageal echocardiography. Milrinone and/or inhaled nitric oxide were available as rescue medication in case of failure to wean from CPB. RESULTS: Inhaled iloprost selectively decreased the pulmonary vascular resistance index after weaning from CPB (208 +/- 108 vs. 422 +/- 62 dyn.s/cm(5)/m(2), P<0.05), increased the RV-ejection fraction (29 +/- 3% vs. 22 +/- 5%, P<0.05), improved the stroke volume index (27 +/- 7 vs. 18 +/- 6 ml/m(2), P<0.05) and reduced the transpulmonary gradient (10 +/- 4 vs. 16 +/- 3 mmHg, P<0.05). In all patients receiving inhaled iloprost, weaning from CPB was successful during the first attempt. In contrast, three patients in the control group required re-institution of CPB and had to be weaned from CPB using rescue medication. CONCLUSIONS: In patients with pre-existing PHT undergoing mitral valve surgery, inhaled iloprost is superior to intravenous nitrogylycerine by acting as a selective pulmonary vasodilator, reducing RV afterload and moderately improving RV-pump performance.


Assuntos
Hipertensão Pulmonar/tratamento farmacológico , Iloprosta/uso terapêutico , Insuficiência da Valva Mitral/cirurgia , Vasodilatadores/uso terapêutico , Administração por Inalação , Idoso , Baixo Débito Cardíaco/tratamento farmacológico , Baixo Débito Cardíaco/etiologia , Ponte Cardiopulmonar , Cateterismo de Swan-Ganz , Ecocardiografia Transesofagiana , Feminino , Humanos , Hipertensão Pulmonar/etiologia , Iloprosta/administração & dosagem , Iloprosta/farmacologia , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Milrinona/uso terapêutico , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Monitorização Intraoperatória , Nitroglicerina/administração & dosagem , Nitroglicerina/uso terapêutico , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Volume Sistólico/efeitos dos fármacos , Resistência Vascular/efeitos dos fármacos , Vasodilatadores/administração & dosagem , Vasodilatadores/farmacologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/prevenção & controle
10.
Acta Anaesthesiol Scand ; 51(9): 1258-67, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17714575

RESUMO

BACKGROUND: In addition to their well-known ability to predict fluid responsiveness, functional pre-load parameters, such as the left ventricular stroke volume variation (SVV) and pulse pressure variation (PPV), have been proposed to allow real-time monitoring of cardiac pre-load. SVV and PPV result from complex heart-lung interactions during mechanical ventilation. It was hypothesized that, under open-chest conditions, when cyclic changes in pleural pressures during positive-pressure ventilation are less pronounced, functional pre-load indicators may be deceptive in the estimation of ventricular pre-load. METHODS: Forty-five patients undergoing coronary artery bypass grafting participated in this prospective, observational study. PPV and SVV were assessed by pulse contour analysis. The thermodilution technique was used to measure the stroke volume index and global and right ventricular end-diastolic volume index. Trans-oesophageal echocardiography was used to determine the left ventricular end-diastolic area index. All parameters were assessed before and after sternotomy, and, in addition, after weaning from cardiopulmonary bypass before and after chest closure (pericardium left open). Patients were ventilated with constant tidal volumes (8 +/- 2 ml/kg) throughout the study period using pressure control. RESULTS: SVV and PPV decreased after sternotomy and increased after chest closure. However, these changes could not be related to concomitant changes in the ventricular pre-load. The stroke volume index was correlated with SVV and PPV in closed-chest conditions only, whereas volumetric indices reflected cardiac pre-load in both closed- and open-chest conditions. SVV and PPV were correlated with left and right ventricular pre-load in closed-chest-closed-pericardium conditions only (with the best correlation found for the right ventricular end-diastolic volume index). CONCLUSIONS: SVV and PPV may be misleading when estimating cardiac pre-load during open heart surgery.


Assuntos
Pressão Sanguínea/fisiologia , Ponte Cardiopulmonar , Monitorização Intraoperatória/métodos , Fluxo Pulsátil/fisiologia , Volume Sistólico/fisiologia , Idoso , Ecocardiografia Transesofagiana , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial , Termodiluição , Função Ventricular Direita/fisiologia
11.
Anaesthesist ; 55(6): 713-28; quiz 729-30, 2006 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-16775733

RESUMO

The indication for the use of the pulmonary artery catheter (PAC) in high-risk patients is still a matter of discussion. Observational studies suggested that the use of the PAC did not result in decreased mortality but may even lead to increased mortality and morbidity. Therefore, a number of randomized controlled trials have been performed throughout recent years in patients suffering from sepsis/ARDS, congestive heart failure, multi-organ failure and those undergoing high-risk non-cardiac surgery. The majority of recent randomized studies failed to demonstrate any benefit of the PAC with respect to mortality and morbidity. However, the use of the PAC was also regularly not associated with an increase in morbidity and/or mortality. This review gives an overview of measurement parameters obtained by the current generation of PACs, alternatives to the PAC and recent studies on the use of the PAC in clinical practice.


Assuntos
Anestesiologia , Cateterismo de Swan-Ganz , Cuidados Críticos , Débito Cardíaco/fisiologia , Cateterismo de Swan-Ganz/efeitos adversos , Hemodinâmica/fisiologia , Humanos , Circulação Pulmonar/fisiologia , Risco
12.
Paediatr Anaesth ; 13(1): 18-25, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12535034

RESUMO

BACKGROUND: Both mechanical and pharmacological effects may contribute to the haemodynamic consequences of carbon dioxide (CO2) pneumoperitoneum. The aim of the present study was to evaluate the haemodynamic effects of low-pressure pneumoperitoneum [intra-abdominal pressure (IAP) 5 mmHg] in young children (< 3 years). METHODS: Thirteen children, aged 6-36 months, ASA physical status I-III, who were scheduled for laparoscopic fundoplication for gastro-oesophageal reflux were investigated in the head-up position (10 degrees ). Noninvasive thoracic electrical bioimpedance cardiac index (CI), stroke volume index (SVI), heart rate (HR), mean arterial pressure (MAP) and peak inspiratory pressure (PIP) were recorded, together with PetCO2 and PaCO2 at five time points: before insufflation, 20, 35 and 70 min after start of CO2 insufflation and 12 min after desufflation. During insufflation, minute ventilation was not adjusted and the IAP was maintained at 5 mmHg. RESULTS: During insufflation, PetCO2 increased from 29 +/- 4 to 37 +/- 5 mmHg (P < 0.001) and PaCO2 increased from 31 +/- 4 to 39 +/- 5 mmHg (P < 0.01). CI increased from 2.39 +/- 0.86 to 2.92 +/- 0.94 l x min-1 x m2 (P < 0.01), HR increased from 108 +/- 10 to 126 +/- 22 b x min-1 (P < 0.01), MAP increased from 52 +/- 10 to 63 +/- 9 (P < 0.05) and PIP increased from 16 +/- 3 to 18 +/- 3 cm H2O (P < 0.001). There were no changes in SVI and arterial oxygen saturation. CONCLUSIONS: We conclude that low-pressure CO2 pneumoperitoneum (with IAPs not exceeding 5 mmHg) for laparoscopic fundoplication in infants and children does not decrease their cardiac index.


Assuntos
Dióxido de Carbono , Hemodinâmica , Pneumoperitônio Artificial , Cardiografia de Impedância , Pré-Escolar , Feminino , Fundoplicatura , Humanos , Lactente , Laparoscopia , Masculino , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA