Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.938
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Gynecol Oncol ; 184: 1-7, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38271772

RESUMO

OBJECTIVES: This study investigated the relationship between Denonvilliers' fascia (DF) and the pelvic plexus branches in women and explored the possibility of using the DF as a positional marker in nerve-sparing radical hysterectomy (RH). METHODS: This study included eight female cadavers. The DF, its lateral border, and the pelvic autonomic nerves running lateral to the DF were dissected and examined. The pelvis was cut into two along the mid-sagittal line. The uterine artery, deep uterine veins, vesical veins, and nerve branches to the pelvic organs were carefully dissected. RESULTS: The nerves ran sagitally, while the DF ran perpendicularly to them. The rectovaginal ligament was continuous with the DF, forming a single structure. The DF attached perpendicularly and seamlessly to the pelvic plexus. The pelvic plexus branches were classified into a ventral part branching to the bladder, uterus, and upper vagina and a dorsal part branching to the lower vagina and rectum as well as into four courses. Nerves were attached to the rectovaginal ligament and ran on its surface to the bladder ventral to the DF. The uterine branches split from the common trunk of these nerves. The most dorsal branch to the bladder primarily had a common trunk with the uterine branch, which is the most important and should be preserved in nerve-sparing Okabayashi RH. CONCLUSION: The DF can be used as a marker for nerve course, particularly in one of the bladder branches running directly superior to the DF, which can be preserved in nerve-sparing Okabayashi RH.


Assuntos
Cadáver , Fáscia , Bexiga Urinária , Feminino , Humanos , Bexiga Urinária/inervação , Fáscia/anatomia & histologia , Fáscia/inervação , Idoso , Histerectomia , Pessoa de Meia-Idade , Plexo Hipogástrico/anatomia & histologia
2.
Int J Legal Med ; 138(3): 1179-1186, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38191742

RESUMO

The identification of hypothermia death (HD) is difficult for cadavers, especially the distinction from death due to alternative causes. A large number of studies have shown that brown adipose tissue (BAT) plays critical roles in thermoregulation of mammals. In this study, BAT of mice was used for the discrimination of HD using attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR). A modified mouse HD model conducted by Feeney DM was used in this study to obtain infrared spectra of BAT. Principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA), and orthogonal partial least squares discriminant analysis (OPLS-DA) were used to establish discrimination models. The PLS-DA and OPLS-DA models exhibit prominent discriminative efficiency, and the accuracy of HD identification using fingerprint regions and ratios of absorption intensity is near 100% in both the calibration and validation sets. Our preliminary study suggests that BAT may be an extremely effective target tissue for identification of cadavers of HD, and ATR-FTIR spectra combined with chemometrics have also shown potential for cadaver identification in forensic practice in a fast and accurate manner.


Assuntos
Hipotermia , Animais , Camundongos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Discriminante , Análise dos Mínimos Quadrados , Cadáver , Mamíferos
3.
Br J Anaesth ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39117476

RESUMO

BACKGROUND: As few anaesthetists provide lumbar erector spinae block for disc surgery, there is a need to provide training to enable a randomised controlled trial investigating analgesia after painful spinal surgery (NIHR153170). The primary objective of the study was to develop and measure the construct validity of a checklist for assessment of skills in performing lumbar and thoracic erector spinae fascial plane injection using soft-embalmed Thiel cadavers. METHODS: Twenty-four UK consultant regional anaesthetists completed two iterations of a Delphi questionnaire. The final checklist consisted of 11 steps conducive to best practice. Thereafter, we validated the checklist by comparing the performance of 12 experts with 12 novices, each performing lumbar and thoracic erector spinae plane injections or fascia iliaca, serrato-pectoral (PEC II) and serratus injections, randomly allocated to the left and right sides of six soft-embalmed Thiel cadavers. Six expert, trained raters blinded to operator and site of block examined 120 videos each. RESULTS: The mean (95% confidence interval) internal consistency of the 11-item checklist for erector spinae plane injection was 0.72 (0.63-0.79) and interclass correlation was 0.88 (0.82-0.93). The checklist showed construct validity for lumbar and thoracic erector spinae injection, experts vs novices {median (interquartile range [range]) 8.0 (7.0-10.0 [1-11]) vs 7.0 (5.0-9.0 [4-11]), difference 1.5 (1.0-2.5), P<0.001}. Global rating scales showed construct validity for lumbar and thoracic erector spinae injection, 28.0 (24.0-31.0 [7-35]) vs 21.0 (17.0-24.0 [7-35]), difference 7.5 (6.0-8.5), P<0.001. The most difficult items to perform were identifying the needle tip before advancing and always visualising the needle tip. Instrument handling and flow of procedure were the areas of greatest difficulty on the global rating scale (GRS). Checklists and GRS scores correlated. There was homogeneity of regression slopes controlling for status, type of injection, and rater. Generalisability analysis showed a high reliability using the checklist and GRS for all fascial plane blocks (Rho [ρ2] 0.93-0.96: Phi [ϕ] 0.84-0.87). CONCLUSIONS: An 11-point checklist developed through a modified Delphi process to provide best practice guidance for fascial plane injection showed construct validity in performing lumbar and thoracic erector spinae fascial plane injection in soft-embalmed Thiel cadavers.

4.
Br J Anaesth ; 132(5): 1146-1152, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38336519

RESUMO

BACKGROUND: Erector spinae plane (ESP) block spread can be unpredictable. We previously improved the spread of ESP injection by addition of retrolaminar (RL) injection. However, it is not clear whether spread at high thoracic levels is similar to spread at midthoracic levels. Our primary objective was to demonstrate that craniocaudal dye spread was equivalent after combined ESP and RL injection using a 19 G Tuohy needle at the third (T3) and sixth (T6) vertebrae in soft embalmed Thiel cadavers. METHODS: We randomised 20 combined ESP and RL injections to the T3 and T6 vertebral levels on both sides of 10 prone Thiel cadavers. A 3-8 MHz transducer was placed in the paramedian sagittal plane and a single anaesthetist injected 10 ml dye onto the transverse process, then 10 ml dye onto the laminae of T3 or T6. Cadavers were dissected 24 h later. RESULTS: Mean (sd) craniocaudal spread of dye after combined ESP + RL injection at T3 and T6 vertebral levels was equivalent: 8.6 (1.8) vs 8.7 (2.3) levels, respectively; difference (90% confidence interval): -0.1 (-1.4 to 1.6), P=0.904. Dye extended uniformly, cranially and caudally, from the point of injection. A 3D prosection created from a Thiel cadaver confirmed that the dorsal ramus emerges from the costotransverse foramen deep to the intertransverse ligament within the retro-superior costotransverse ligament space. Combined ESP and RL block in six patients before mastectomy achieved extensive anterior, lateral, and posterior chest wall paraesthesia over four to six dermatomes. CONCLUSIONS: Combined ESP and RL injections showed equivalent and consistent spread at T3 and T6 injection sites. A pilot study confirmed translation to patients.


Assuntos
Neoplasias da Mama , Bloqueio Nervoso , Humanos , Feminino , Vértebras Torácicas/diagnóstico por imagem , Projetos Piloto , Mastectomia , Cadáver , Ultrassonografia de Intervenção
5.
Artigo em Inglês | MEDLINE | ID: mdl-38837465

RESUMO

AIM: The aim of this study on native human cadavers was to compare clinical, sonographic, and radiological measurements of fenestrations, dehiscences, and 3-wall bone defects on implants. MATERIALS AND METHODS: The examination was carried out on five human mandibles. After the insertion of 27 implants, dehiscences (n = 14), fenestrations (n = 7) and 3-wall bone defects (n = 6) were prepared in a standardized manner. The direct measurement of the bone defects was carried out with a periodontal probe and the radiological examination was carried out using digital volume tomography (DVT). The ultrasound examination (US) was performed using a clinical 24-MHz US imaging probe. Means and standard deviations of the direct, US, and DVT measurements were calculated. Measurements were statistically compared using the Pearson correlation coefficient and Bland-Altman analysis. RESULTS: Bone defects were on average 3.22 ± 1.58 mm per direct measurement, 2.90 ± 1.47 mm using US, and 2.99 ± 1.52 mm per DVT assessment. Pairwise correlations of these measurements were R = .94 (p < .0001) between direct and US, R = .95 (p < .0001) between DVT and US, and R = .96 (p < .0001) between direct and DVT. The mean differences of the measurements (and 95% CI) between direct and US was 0.41 (-0.47 to 1.29), US and DVT 0.33 (-0.30 to 0.97), and direct and DVT 0.28 (-0.50 to 1.07). CONCLUSION: All peri-implant bone defects could be identified and sonographically measured. US measurements showed a strong correlation with direct and DVT measurements. The sonographic measurement accuracy was highest for dehiscences, followed by fenestrations and 3-wall bone defects.

6.
Lasers Surg Med ; 56(4): 382-391, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38570914

RESUMO

BACKGROUND AND OBJECTIVES: Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open-angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. MATERIALS AND METHODS: An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 µm wide by 200 µm high) in human cadaver eyes using pulse energies of 10, 15, and 20 µJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. RESULTS: Pulse energies of 15 and 20 µJ had a 100% success rate in creating full-thickness FLT channels as imaged by OCT. A pulse energy of 10 µJ resulted in no channels (n = 6), a partial-thickness channel (n = 2), and a full-thickness FLT channel (n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 µJ groups (p < 0.0001), as well as between the 10 and 20 µJ groups (p < 0.0001). However, there was no statistically significant difference between the 15 and 20 µJ groups (p = 0.416). CONCLUSIONS: Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Lasers , Cadáver
7.
Neurosurg Rev ; 47(1): 190, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658446

RESUMO

OBJECTIVE: We assessed types of cadaveric head and brain tissue specimen preparations that are used in a high throughput neurosurgical research laboratory to determine optimal preparation methods for neurosurgical anatomical research, education, and training. METHODS: Cadaveric specimens (N = 112) prepared using different preservation and vascular injection methods were imaged, dissected, and graded by 11 neurosurgeons using a 21-point scale. We assessed the quality of tissue and preservation in both the anterior and posterior circulations. Tissue quality was evaluated using a 9-point magnetic resonance imaging (MRI) scale. RESULTS: Formalin-fixed specimens yielded the highest scores for assessment (mean ± SD [17.0 ± 2.8]) vs. formalin-flushed (17.0 ± 3.6) and MRI (6.9 ± 2.0). Cadaver assessment and MRI scores were positively correlated (P < 0.001, R2 0.60). Analysis showed significant associations between cadaver assessment scores and specific variables: nonformalin fixation (ß = -3.3), preservation within ≤72 h of death (ß = 1.8), and MRI quality score (ß = 0.7). Formalin-fixed specimens exhibited greater hardness than formalin-flushed and nonformalin-fixed specimens (P ≤ 0.006). Neurosurgeons preferred formalin-flushed specimens injected with colored latex. CONCLUSION: For better-quality specimens for neurosurgical education and training, formalin preservation within ≤72 h of death was preferable, as was injection with colored latex. Formalin-flushed specimens more closely resembled live brain parenchyma. Assessment scores were lower for preparation techniques performed > 72 h postmortem and for nonformalin preservation solutions. The positive correlation between cadaver assessment scores and our novel MRI score indicates that donation organizations and institutional buyers should incorporate MRI as a screening tool for the selection of high-quality specimens.


Assuntos
Encéfalo , Cadáver , Imageamento por Ressonância Magnética , Neurocirurgia , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neurocirurgia/educação , Procedimentos Neurocirúrgicos/métodos
8.
J Biomech Eng ; 146(10)2024 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-38683101

RESUMO

Understanding the biomechanical impact of injuries and reconstruction of the anterior cruciate ligament (ACL) is vital for improving surgical treatments that restore normal knee function. The purpose of this study was to develop a technique that enables parametric analysis of the effect of the ACL reconstruction (ACLR) in cadaver knees, by replacing its contributions with that of a specimen-specific virtual ACLR that can be enabled, disabled, or modified. Twelve ACLR reconstructed knees were mounted onto a motion simulator. In situ ACLR graft forces were measured using superposition, and these data were used to design specimen-specific virtual ACLRs that would yield the same ligament force-elongation behaviors. Tests were then repeated using the virtual ACLR in place of the real ACLR and following that in ACL deficient knee by disabling the virtual ACLR. In comparison to the ACL deficient state, the virtual ACLRs were able to restore knee stability to the same extent as real ACLRs. The average differences between the anterior tibial translation (ATT) of the virtual ACLR versus the real ACLR were +1.6 ± 0.9 mm (p = 0.4), +2.1 ± 0.4 mm (p = 0.4), and +1.0 ± 0.9 mm (p = 0.4) during Anterior drawer, Lachman and Pivot-shift tests, respectively, which is small in comparison to the full ATT range of motion (ROM) of these knees. Therefore, we conclude that a virtual ACLR can be used in place of real ACLR during biomechanical testing of cadaveric knees. This capability opens the door for future studies that can leverage parameterization of the ACLR for surgical design optimization.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Articulação do Joelho , Fenômenos Mecânicos , Humanos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Amplitude de Movimento Articular
9.
J Ultrasound Med ; 43(6): 999-1011, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38369775

RESUMO

OBJECTIVES: Teaching ultrasound imaging is on the rise in undergraduate medical anatomy education. However, there is little research exploring the use of ultrasound in preparatory graduate programs. The purpose of this study is to identify the effects of ultrasound imaging inclusion in a graduate gross anatomy course. METHODS: Master of Medical Sciences students were enrolled in a prosection-based anatomy course that included pinned cadaver stations and an ultrasound station. Using ultrasound, teaching assistants imaged volunteers demonstrating anatomical structures students previously learned at cadaver stations. Students answered one ultrasound image question on each practical exam and were asked to participate in a pre- and post-course survey. Student practical and lecture exam scores and final course grades from the 2022 cohort were compared to a historical control cohort from 2021 via statistical analysis, including a survey administered to the 2022 cohort. RESULTS: Two hundred students from the 2021 cohort and 164 students from the 2022 cohort participated in this study. Students in the 2022 cohort had significantly higher scores in 1 of the 5 practical exams (P < .05, d = .289), and 2 of the 5 written exams (P < .05, d = .207), (P < .05, d = .311). Survey data revealed increased (P < .05, d = 1.203) learning outcome achievement from pre-survey to post-survey in the intervention cohort. Students who correctly answered the ultrasound question performed significantly better on practical's 3 (P < .05) and 4 (P < .05) than those who missed the ultrasound question. CONCLUSIONS: These findings suggest that ultrasound imaging in a cadaver lab is beneficial to graduate students' learning and understanding of gross anatomy.


Assuntos
Anatomia , Currículo , Avaliação Educacional , Estudantes de Medicina , Ultrassonografia , Humanos , Anatomia/educação , Ultrassonografia/métodos , Estudantes de Medicina/estatística & dados numéricos , Avaliação Educacional/estatística & dados numéricos , Feminino , Masculino , Educação de Pós-Graduação em Medicina/métodos , Estudos de Coortes , Inquéritos e Questionários
10.
J Korean Med Sci ; 39(20): e159, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38804009

RESUMO

Anatomy is a foundational subject in medicine and serves as its language. Hippocrates highlighted its importance, while Herophilus pioneered human dissection, earning him the title of the founder of anatomy. Vesalius later established modern anatomy, which has since evolved historically. In Korea, formal anatomy education for medical training began with the introduction of Western medicine during the late Joseon Dynasty. Before and after the Japanese occupation, anatomy education was conducted in the German style, and after liberation, it was maintained and developed by a small number of domestic anatomists. Medicine in Korea has grown alongside the country's rapid economic and social development. Today, 40 medical colleges produce world-class doctors to provide the best medical care service in the country. However, the societal demand for more doctors is growing in order to proactively address to challenges such as public healthcare issues, essential healthcare provision, regional medical service disparities, and an aging population. This study examines the history, current state, and challenges of anatomy education in Korea, emphasizing the availability of medical educators, support staff, and cadavers for gross anatomy instruction. While variations exist between Seoul and provincial medical colleges, each manages to deliver adequate education under challenging conditions. However, the rapid increase in medical student enrollment threatens to strain existing anatomy education resources, potentially compromising educational quality. To address these concerns, we propose strategies for training qualified gross anatomy educators, ensuring a sustainable cadaver supply, and enhancing infrastructure.


Assuntos
Anatomia , Educação Médica , Humanos , Anatomia/educação , Cadáver , Educação Médica/história , Educação Médica/métodos , Educação Médica/tendências , História do Século XX , República da Coreia , Faculdades de Medicina/história , Faculdades de Medicina/tendências
11.
J Hand Surg Am ; 49(3): 212-221, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38069954

RESUMO

PURPOSE: Despite modern advancements in the treatment of late stages of wrist joint degeneration, few reliable options exist for patients requiring motion-preserving reconstruction of their radiocarpal and midcarpal joints. Vascularized composite allotransplantation (VCA) could be considered an option for wrist reconstruction in the future. The goal of this study was to describe the relevant anatomy and design a potential surgical technique for wrist VCA. METHODS: Anatomic studies were performed on 17 human upper extremities. The arterial system of each cadaver was injected with latex dye or radiographic contrast. After injecting a contrast medium visible on a computerized tomography (CT) scan, the initial three specimens were examined using microCT. This confirmed joint vascular patency and allowed for the dissection of the other specimens that were injected with latex for the study of joint vascularization and the design of the wrist VCA. We then outlined a donor and recipient surgical technique for transplant based on recipient CT scans. Customized cutting guides were designed for the transplant procedure. After the procedure, we performed angiography of the VCA to determine the vascularity of the transplant. RESULTS: Using a combined volar and dorsal approach, we were able to perform a complete wrist VCA procedure. After the completed transplant procedure, angiographic imaging of the specimens demonstrated that the flap dissection and transplantation preserved the nutrient endosteal supply to the distal end of the radius and ulna, as well as to the carpal bones and the metacarpal bases. CONCLUSIONS: The dissection of the donor, recipient, and the entire vascularized joint transplant procedure served to illustrate the anatomical feasibility of the cadaveric surgical technique. This establishes an anatomic basis for the possibility of future human clinical applications. CLINICAL RELEVANCE: This study helps investigate the anatomical feasibility of a wrist VCA.


Assuntos
Látex , Alotransplante de Tecidos Compostos Vascularizados , Humanos , Estudos de Viabilidade , Articulação do Punho/cirurgia , Meios de Contraste , Cadáver
12.
Clin Anat ; 37(4): 376-382, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37283304

RESUMO

Smile reconstruction using the branches that supply the zygomaticus major muscle as a motor source is an established procedure in facial reanimation surgery for facial paralysis. However, the anatomy of the nerve to the muscle remains unclear. Therefore, we herein examined the topographical anatomy of the nerve to the zygomaticus major muscle to obtain more detailed information on donor nerve anatomy. Preserved cadaver dissection was performed under a microscope on 13 hemifaces of 8 specimens. The branches that innervate the zygomaticus major muscle and their peripheral routes medial to the muscle were traced and examined. A median of four (ranges 2-4) branches innervated the zygomaticus major muscle. The proximal two branches (near the muscle origin) arose from the zygomatic branch, the second of which was the major branch. The distal branches (near the oral commissure) arose from the buccal branch or zygomaticobuccal plexus. The vertical distance from the caudal margin of the zygomatic arch to the major branch intersecting point was 19 ± 4.0 mm, while the horizontal distance parallel to the Frankfort plane was 29 ± 5.2 mm. The proximal two branches innervating the zygomaticus major muscle were detected in the majority of specimens. The anatomical findings obtained herein on the nerve to the zygomaticus major muscle will allow for more reliable donor selection in facial reanimation surgery.


Assuntos
Nervo Facial , Paralisia Facial , Humanos , Nervo Facial/cirurgia , Nervo Facial/anatomia & histologia , Face/inervação , Músculos Faciais/cirurgia , Músculos Faciais/inervação , Paralisia Facial/cirurgia , Sorriso/fisiologia , Cadáver
13.
Clin Anat ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38845406

RESUMO

This study aimed to evaluate the superficial medial collateral ligament distal tibial attachment (sMCL-dTA) morphologically and morphometrically. Seventeen unpaired formalin-fixed cadaveric knees were used. The sMCL was divided into anterior and posterior sections in the paracoronal plane along the midline of the sMCL. The distance from the medial edge of the tibial plateau and the joint line to the proximal margin, center, and distal margin of the sMCL-dTA and the length of the sMCL-dTA were measured in the anterior section, respectively. The sMCL-dTA was histologically observed in the posterior section with hematoxylin and eosin and Masson's trichrome staining. The distance from the medial edge of the tibial plateauto the proximal margin, center, and distal margin of the sMCL-dTA were 38.1 ± 4.2, 49.7 ± 4.4, and 61.5 ± 5.1 mm, respectively. The perpendicular distance from the joint line to the proximal margin, center, and distal margin of the sMCL-dTA were 36.1 ± 4.0, 47.4 ± 4.2, and 59.1 ± 4.8 mm, respectively. The length of the sMCL-dTA was 23.6 ± 3.2 mm. Histologically, the sMCL-dTA was formed by two layers of collagen fibers: the unidirectional fibrous layer and the multidirectional fibrous layer. The respective thicknesses of the two layers both decreased distally. The anatomical location, the length, and the attachment morphology of sMCL-dTA have been clarified using human cadaveric knees. Anatomical data in the present study contribute to the quality of surgery associated with sMCL-dTA.

14.
Clin Anat ; 37(5): 555-562, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38469731

RESUMO

Histological observation under light microscopy has long been used in human cadaveric studies. However, it can distort the interpretations of findings if not used appropriately; there is no guide for its proper use. The aim of this article is to revisit and discuss the correct use of histology in human cadaveric studies, following discussions with experts in multiple fields of medicine, and to create the first guide for such usage. We reached a consensus with the experts, agreeing that when this principle (structure, quantification, interaction, position: SQIP) is applied to histological observations, the findings will be interpreted correctly. Appropriate use of this recommendation can make human cadaveric studies more accurate and informative. This is the first histology guide for human cadaveric studies.


Assuntos
Cadáver , Microscopia , Humanos , Microscopia/métodos
15.
Clin Anat ; 37(1): 140-146, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37792451

RESUMO

The ligamentum arteriosum (LA) is the vestigial fibrous remnant of the ductus arteriosus (DA), a fetal vessel arising from the left dorsal segment of the sixth aortic arch that connects the left pulmonary artery to the aortic arch. Incomplete obliteration of the DA results in a patent ductus arteriosus (PDA), causing the shunting of oxygen-rich blood to recirculate to the lungs, which can lead to pulmonary hypertension. The current study aims to further elucidate the structural characteristics of the LA via histological analysis with data gathered from adult cadaveric specimens. The LA was harvested and histologically observed with Hematoxylin and Eosin, van Gieson, and Masson's trichrome staining. Fibrous and muscle tissues were observed in all 25 specimens. The LA was categorized into three types based on the morphological features of the LA. Type I (vessel-like structure), type II (fibrotic tissue with duct-like structure), and type III (no duct-like structure) were found in 4.0%, 80.0%, and 16.0%, respectively. Finally, the remnant of a valve in the LA was also observed at the junction between the AA and LA. We suggest that this valve be called the "pulmonary-aortic valve." In the majority of the adult LAs, a duct-like structure was still present. These data could better elucidate our understanding of the pathology and etiology of a PDA.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Humanos , Adulto , Permeabilidade do Canal Arterial/patologia , Aorta Torácica , Artéria Pulmonar , Canal Arterial/patologia , Aorta/patologia
16.
Clin Anat ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075749

RESUMO

The silicone rubber injection technique was first described in 1999 and has been used in the vascular study of neurology and head and neck dissection. Silicone rubber is durable, flexible, and inexpensive. However, the original silicone rubber injection formula perfuses poorly into the pelvis and extremities. We present a simple modification to the silicone rubber injection technique, showcasing its effectiveness in studying the vascular structures in the pelvis and extremities. We used an ordinary mold-making silicone rubber. The new formula involves mixing the silicone rubber with silicone thinner, acetone, catalyst, and resin color. The mixture is then injected into the artery until the color becomes visible under the skin. The specimen is left at room temperature for 0.5-1 h for the silicone rubber to harden. With our technique, the silicone rubber substance perfuses adequately into small arterial perforators and can penetrate into the subdermal plexus. The smallest subdermal arteries identified under a light microscope measured 6 µm. The modified silicone rubber injection technique has proven to be a valuable tool in anatomical education and surgical training.

17.
Clin Anat ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38938222

RESUMO

Design thinking (DT) is a five-stage process (empathize, define, ideate, prototype, and test) that guides the creation of user-centered solutions to complex problems. DT is in common use outside of science but has rarely been applied to anatomical education. The use of DT in this study identified the need for flexible access to anatomical specimens outside of the anatomy laboratory and guided the creation of a digital library of three-dimensional (3D) anatomical specimens (3D Anatomy Viewer). To test whether the resource was fit for purpose, a mixed-methods student evaluation was undertaken. Student surveys (n = 46) were employed using the system usability scale (SUS) and an unvalidated acceptability questionnaire. These verified that 3D Anatomy Viewer was usable (SUS of 72%) and acceptable (agreement range of 77%-93% on all Likert-type survey statements, Cronbach's alpha = 0.929). Supplementary interviews (n = 5) were analyzed through content analysis and revealed three main themes: (1) a credible online supplementary learning resource; (2) learning anatomy with 3D realism and interactivity; (3) user recommendations for expanding the number of anatomical models, test questions, and gamification elements. These data demonstrate that a DT framework can be successfully applied to anatomical education for creation of a practical learning resource. Anatomy educators should consider employing a DT framework where student-centered solutions to learner needs are required.

18.
Clin Anat ; 37(5): 563-570, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38501651

RESUMO

Learning human anatomy is essential for Doctor of Physical Therapy (DPT) education. Body donors are traditionally utilized to understand content, but in a hybrid learning environment, students have limited time to use body donors. To improve body donor access and learning, we created online synchronous pre-body donor activities. The impact of these online strategies on students' subsequent exams and final grade were investigated in a non-randomized, observational study. These activities were hypothesized to positively influence students' anatomy performance. In a 16-week semester, DPT students (case [n = 91], control [n = 22]) participated in a hybrid program of asynchronous/synchronous online learning and two in-person immersions. Measures included student course grades and teaching surveys. Spearman's rho correlations analyzed the relationship between four pre-body donor quizzes to body donor exams, written exams, and final course grade. Mann-Whitney U tests assessed differences in grades between cohorts. A linear regression model examined the influence of pre-body donor quizzing on exams/final grades. Correlation tests revealed a strong relationship between the average pre-body donor quiz score and both the first written exam and final course grade (p = 0.0001). The case group achieved significantly higher scores than the control group on the first in-person body donor exam (p = 0.011), the second written exam (p = 0.0001), and the final grade (p = 0.004). The pre-body donor quizzes predicted performance on the subsequent in-person body donor exams, written exams, and the final grade. Implementation of online pre-body donor learning activities was associated with increased academic performance among hybrid DPT students and may aid in learning anatomy concepts for clinical practice.


Assuntos
Anatomia , Avaliação Educacional , Humanos , Anatomia/educação , Doadores de Tecidos , Masculino , Feminino
19.
Aesthetic Plast Surg ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951229

RESUMO

PURPOSE: The exit points of the supraorbital nerve and its branches hold significant importance in various medical procedures, including supraorbital endoscopic surgeries, forehead-facial aesthetic plastic surgeries, medical aesthetic applications and maxillofacial surgeries. Therefore, the primary objective of the present study was to precisely define the dimension, location and clinical significance of the supraorbital foramen/notch. By doing so, we aimed to enhance our understanding of this anatomical structure and its implications for surgical and aesthetic interventions in the supraorbital region. METHODS: For our study, we conducted anatomical dissections and bone measurements to assess the significance of anatomical variations of the supraorbital foramen/notch. We utilized a sample consisting of 28 cadavers and 38 skulls. The supraorbital foramen/notch was bilaterally analyzed in all 28 cadavers and 38 dry bones. We morphometrically analyzed the distance between the supraorbital foramen/notch and various anatomical landmarks, including the nasion, supraorbital margin, infraorbital margin, temporal crest, glabella, frontal cavity and midline of the face. Additionally, we measured the distance between the supraorbital foramen/notches and the frontal foramen/notches, and the width of the supraorbital foramen/notch and the distance between both supraorbital foramina/notches. RESULTS: There are 32 (57.14%) supraorbital  foramina, and the remaining are 24 (42.86%) supraorbital notches in cadavers and there are 36 (47.37%) supraorbital foramina, and the remaining are 40 (52.63%) supraorbital notches in skulls. We observed consistency in the dimension and location values of anatomical measurement parameters between cadavers and dry skulls on both right and left sides, with the exception of the parameter "distance from temporal crest" (p=0.042). Furthermore, our correlation analysis revealed a significant positive relationship between the right and left sides across all parameters, except for the following instances: in dry skulls, "distance from supraorbital margin" and in cadaver parameters, "distance from temporal crest, " "distance from frontal cavity" and "width." CONCLUSION: In our study, we observed that the distributions of supraorbital foramina and notches were nearly similar. Furthermore, our findings indicated comparable measurements between the right and left sides in both cadavers and skulls. These results suggest a degree of consistency in supraorbital anatomy within our study sample, regardless of the specimen type (cadavers or skulls) or laterality (right or left side). NO LEVEL ASSIGNED: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

20.
Aesthetic Plast Surg ; 48(11): 2042-2049, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38528126

RESUMO

PURPOSE: The aim of this study is to investigate the origin and course of the orbital fat arterial supply in the lower eyelid using traditional anatomy and three-dimensional computed tomography (CT). METHODS: Twenty-seven cadaver heads were infused with mercury sulfide contrast media through the ophthalmic artery, maxillary artery, transverse facial artery, and facial artery. CT images were obtained after contrast agent injection, three-dimensional CT scans were reconstructed, and the cadaver heads were dissected. RESULTS: Forty-five qualified hemifaces showed that the orbital fat arterial supply in the lower eyelid originates primarily from the inferomedial muscular trunk (IMT) of the ophthalmic artery and the orbital branch of the infraorbital artery. The medial branch of the IMT terminated at the medial fat pad (35.6%) or the orbital floor (64.4%). The lateral branch terminated at the inferior oblique (IO) muscle (28.9%) or the central and lateral fat pads (17.8%). In 53.3%, the lateral branch extended to the anterior part of the lateral fat pad and terminated in the orbital wall or the zygomaticoorbital foramina. The orbital branch of the infraorbital artery coursed between the orbital floor and the orbital fat, providing supply to the IO muscle, inferior rectus (IR) muscle, nasolacrimal duct, and orbital fat. CONCLUSION: This study elucidated the origin and course of the orbital fat arterial supply in the lower eyelid, which may help to avoid reducing the blood supply of the orbital fat pedicles during surgery. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Tecido Adiposo , Cadáver , Pálpebras , Órbita , Tomografia Computadorizada por Raios X , Humanos , Pálpebras/irrigação sanguínea , Pálpebras/anatomia & histologia , Pálpebras/diagnóstico por imagem , Feminino , Tecido Adiposo/irrigação sanguínea , Tecido Adiposo/anatomia & histologia , Órbita/irrigação sanguínea , Órbita/diagnóstico por imagem , Órbita/anatomia & histologia , Masculino , Imageamento Tridimensional , Pessoa de Meia-Idade , Adulto , Relevância Clínica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA