1.
COPD ; 21(1): 2321379, 2024 12.
Artigo em Inglês | MEDLINE | ID: mdl-38655897

RESUMO

INTRODUCTION: Spirometry is the gold standard for COPD diagnosis and severity determination, but is technique-dependent, nonspecific, and requires administration by a trained healthcare professional. There is a need for a fast, reliable, and precise alternative diagnostic test. This study's aim was to use interpretable machine learning to diagnose COPD and assess severity using 75-second carbon dioxide (CO2) breath records captured with TidalSense's N-TidalTM capnometer. METHOD: For COPD diagnosis, machine learning algorithms were trained and evaluated on 294 COPD (including GOLD stages 1-4) and 705 non-COPD participants. A logistic regression model was also trained to distinguish GOLD 1 from GOLD 4 COPD with the output probability used as an index of severity. RESULTS: The best diagnostic model achieved an AUROC of 0.890, sensitivity of 0.771, specificity of 0.850 and positive predictive value (PPV) of 0.834. Evaluating performance on all test capnograms that were confidently ruled in or out yielded PPV of 0.930 and NPV of 0.890. The severity determination model yielded an AUROC of 0.980, sensitivity of 0.958, specificity of 0.961 and PPV of 0.958 in distinguishing GOLD 1 from GOLD 4. Output probabilities from the severity determination model produced a correlation of 0.71 with percentage predicted FEV1. CONCLUSION: The N-TidalTM device could be used alongside interpretable machine learning as an accurate, point-of-care diagnostic test for COPD, particularly in primary care as a rapid rule-in or rule-out test. N-TidalTM also could be effective in monitoring disease progression, providing a possible alternative to spirometry for disease monitoring.


Assuntos
Capnografia , Aprendizado de Máquina , Doença Pulmonar Obstrutiva Crônica , Índice de Gravidade de Doença , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Capnografia/métodos , Idoso , Modelos Logísticos , Sensibilidade e Especificidade , Volume Expiratório Forçado , Algoritmos , Valor Preditivo dos Testes , Área Sob a Curva , Estudos de Casos e Controles , Espirometria/instrumentação
2.
Acta Paediatr ; 112(5): 919-923, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36843232

RESUMO

AIM: The aim of this review was to give an overview of available data on end-tidal CO2 (etCO2 ) monitoring, also called capnometry, during neonatal transport. METHODS: Pubmed/MEDLINE database was searched using research question (capno* OR etCO2 OR detCO2 OR (['end tidal' OR 'end-tidal'] AND [CO2 OR 'carbon dioxide']) AND (neonat* OR infant* OR newborn*) AND transport*). All articles relevant to the topic were reviewed and summarised. RESULTS: The lack of studies relevant to neonatal transport prompted us to extend the search to capnometry in a neonatal intensive care setting. The published studies are showing conflicting results. The different study populations, technologies used to measure etCO2 , types of etCO2 sampling and the diverse sites of blood gas tests make the data unsuitable for systematic comparison. CONCLUSION: Further research to obtain more data on capnometry during neonatal transport will be necessary to define precisely under what circumstances can end-tidal monitoring of CO2 be reliably used in neonates during transport and also how to interpret the measured values.


Assuntos
Capnografia , Dióxido de Carbono , Humanos , Lactente , Recém-Nascido , Capnografia/métodos , Terapia Intensiva Neonatal , Transporte de Pacientes , Respiração Artificial
3.
Sensors (Basel) ; 23(13)2023 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-37447945

RESUMO

The development of a capnometry wristband is of great interest for monitoring patients at home. We consider a new architecture in which a non-dispersive infrared (NDIR) optical measurement is located close to the skin surface and is combined with an open chamber principle with a continuous circulation of air flow in the collection cell. We propose a model for the temporal dynamics of the carbon dioxide exchange between the blood and the gas channel inside the device. The transport of carbon dioxide is modeled by convection-diffusion equations. We consider four compartments: blood, skin, the measurement cell and the collection cell. We introduce the state-space equations and the associated transition matrix associated with a Markovian model. We define an augmented system by combining a first-order autoregressive model describing the supply of carbon dioxide concentration in the blood compartment and its inertial resistance to change. We propose to use a Kalman filter to estimate the carbon dioxide concentration in the blood vessels recursively over time and thus monitor arterial carbon dioxide blood pressure in real time. Four performance factors with respect to the dynamic quantification of the CO2 blood concentration are considered, and a simulation is carried out based on data from a previous clinical study. These demonstrate the feasibility of such a technological concept.


Assuntos
Capnografia , Dióxido de Carbono , Humanos , Difusão , Monitorização Fisiológica/métodos
4.
J Clin Monit Comput ; 37(1): 311-317, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35896757

RESUMO

Isocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I-II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O2/air (40% inspired O2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle system, while increasing ventilation to a target PETCO2 of 4.7-4.9% by adjusting respiratory rate during controlled mechanical ventilation. Pa-ETCO2 gradients were determined after a 15 min equilibration period at each PICO2 level and compared using ANOVA. Mean (standard deviation) age, height, and weight were 66 (6) years, 171 (6) cm, and 75 (8) kg, respectively. Capnograms were normal and hemodynamic parameters remained stable. PETCO2 could be maintained within 4.7-4.9% in all subjects at all times except in 1 subject with 1.5% PICO2 and 5 subjects with 2.0% PICO2; data from the one subject in whom both 1.5 and 2.0% PICO2 resulted in PETCO2 > 5.1% were excluded from analysis. Pa-ETCO2 gradients did not change when PICO2 increased. The effect of a modest rise of PICO2 up to 1.5% on PETCO2 during RARP can be readily overcome by increasing ventilation without altering the Pa-ETCO2 gradients. At higher PICO2, airway pressures may become a limiting factor, which requires further study.


Assuntos
Dióxido de Carbono , Hiperventilação , Masculino , Humanos , Idoso , Respiração , Respiração Artificial , Pulmão
5.
Eur J Pediatr ; 181(2): 629-636, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34494159

RESUMO

This study aimed to determine whether a specific portable capnometer (EMMA™) can facilitate the maintenance of an appropriate partial pressure of arterial carbon dioxide (PaCO2) in intubated preterm infants in the delivery room. This study included preterm infants with a gestational age of 26 + 0 to 31 + 6 weeks who required intubation in the delivery room. We prospectively identified 40 infants who underwent the EMMA™ monitoring intervention group and 43 infants who did not undergo monitoring (historical control group). PaCO2 was evaluated either at admission in the neonatal intensive care unit or at 2 h after birth. The proportion of infants with an appropriate PaCO2 (35-60 mmHg) was greater in the intervention group than in the control group (80% vs. 42%; p = 0.001). There were no significant differences in the rate of accidental extubation (5.0% vs. 7.0%, p = 1.00) or in the proportion of infants with an appropriate PaCO2 among infants whose birth weight was < 1000 g (54% vs. 40%, p = 0.49). However, among infants whose birth weight was ≥ 1000 g, the PaCO2 tended to be more appropriate in the intervention group than in the control group (93% vs. 44%; p < 0.001).Conclusion: The EMMA™ facilitated the maintenance of an appropriate PaCO2 for mechanically ventilated preterm infants, especially infants with birth weight ≥1000 g, in the delivery room. What is Known: • An inappropriate partial pressure of arterial carbon dioxide has been associated with intraventricular hemorrhage in preterm infants. • There is a need to appropriately control the partial pressure of arterial carbon dioxide in preterm infants. What is New: • This is the first report regarding the feasibility of a portable capnometer, the EMMA™, in the delivery room. • The EMMA™ may be considered a feasible monitoring device in the delivery room for intubated preterm infants, especially infants with birth weight ≥1000 g.


Assuntos
Salas de Parto , Respiração Artificial , Dióxido de Carbono , Estudos de Viabilidade , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Gravidez
6.
J Clin Monit Comput ; 36(3): 809-816, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33928469

RESUMO

The use of clinical scoring to assess for severity of respiratory distress and respiratory failure is challenging due to subjectivity and interrater variability. Transcutaneous Capnography (TcpCO2) can be used as an objective tool to assess a patient's ventilatory status. This study was designed to assess for any correlation of continuous monitoring of TcpCO2 with the respiratory clinical scores and deterioration in children admitted for acute respiratory distress. A prospective observational study over one year on children aged 2 weeks to 5 years admitted with acute respiratory distress or failure secondary to Bronchiolitis and Reactive airway disease was performed. Continuous TcpCO2 monitoring for upto 48 h was recorded. Investigators, bedside physicians, respiratory therapists, and nurses were blinded from the transcutaneous trends at the time of data collection. Total of 813 TcpCO2 measurements at standard intervals of 30 min were obtained on 38 subjects. Subjects with abnormal TcpCO2 (> 45 mmHg) were younger (6.9 ± 5.2 vs. 23.05 ± 17.7 months,) and were more likely to be on higher oxygen flow rate (0.52 L/min/kg vs 0.46 lier/min/kg, p = 0.004) and higher FiO2 (38.4 vs 33.6, p < 0.001 using heated high flow nasal cannula. No difference was found in bronchiolitis score or PEW score in subjects with normal and abnormal TcpCO2. A small but statistically significant increase in TcpCO2 was observed at the escalation of care. Even though odds of escalation of care are higher with abnormal TcpCO2 (OR 1.92), this difference did not reach statistical significance. pCO2 can provide additive information for non-invasive clinical monitoring of children requiring varying respiratory support; however, it does not provide predictive value for escalation or de-escalation of care.


Assuntos
Asma , Bronquiolite , Síndrome do Desconforto Respiratório , Monitorização Transcutânea dos Gases Sanguíneos , Dióxido de Carbono , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica
7.
Int J Nurs Pract ; 28(2): e13049, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35285146

RESUMO

AIM: To determine the effectiveness of auscultatory, colorimetric capnometry and pH measurement methods for confirmation of correct nasogastric tube placement in critically ill patients. BACKGROUND: Incorrect nasogastric tube placement causes serious complications. DESIGN: This was a methodological and comparative study. METHODS: The study sample consisted of 88 new insertions of nasogastric feeding tubes between April 2018-2019. Results from the 'auscultatory', 'pH' and 'colorimetric capnometry' methods were compared with the location of the nasogastric tube as determined through radiography. Descriptive statistics, Eta analysis and the Cohen kappa compliance test as well as sensitivity and specificity were conducted. RESULTS: There was a weak agreement (26.3%) between the auscultation and radiological evaluation for confirming nasogastric tube placement. The pH measurement and colorimetric capnometry methods were not correlated with radiological evaluation. Stomach pH increased as patient age increased and use of the colorimetric capnometry method failed to confirm the oesophageal and duodenal location. The specificity of the auscultation was low, and both the specificity and sensitivity pH methods were low. CONCLUSION: It was determined that auscultation, measuring pH and colorimetric capnometry were unreliable methods for confirming placement of nasogastric tubes. It is recommended to confirm initial placement of the nasogastric tube with radiography and to develop effective and reliable non-radiological measurement methods that can be performed at the bedside.


Assuntos
Colorimetria , Intubação Gastrointestinal , Auscultação , Capnografia , Humanos , Concentração de Íons de Hidrogênio
8.
BMC Pulm Med ; 21(1): 198, 2021 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112130

RESUMO

BACKGROUND: Patients undergoing bronchoscopy in spontaneous breathing are prone to hypoxaemia and hypercapnia. Sedation, airway obstruction, and lung diseases impair respiration and gas exchange. The restitution of normal respiration takes place in the recovery room. Nonetheless, there is no evidence on the necessary observation time. We systematically reviewed current guidelines on bronchoscopy regarding sedation, monitoring and recovery. METHODS: This review was registered at the PROSPERO database (CRD42020197476). MEDLINE and awmf.org were double-searched for official guidelines, recommendation or consensus statements on bronchoscopy from 2010 to 2020. The PICO-process focussed on adults (Patients), bronchoscopy with maintained spontaneous breathing (Interventions), and recommendations regarding the intra- and postprocedural monitoring and sedation (O). The guideline quality was graded. A catalogue of 54 questions was answered. Strength of recommendation and evidence levels were recorded for each recommendation. RESULTS: Six guidelines on general bronchoscopy and three expert statements on special bronchoscopic procedures were identified. Four guidelines were evidence-based. Most guidelines recommend sedation to improve the patient's tolerance. Midazolam combined with an opioid is preferred. The standard monitoring consists of non-invasive blood pressure, and pulse oximetry, furthermore electrocardiogram in cardiac patients. Only one guideline discusses hypercapnia and capnometry, but without consensus. Two guidelines discuss a recovery time of two hours, but a recommendation was not given because of lack of evidence. CONCLUSION: Evidence for most issues is low to moderate. Lung-diseased patients are not represented by current guidelines. Capnometry and recovery time lack evidence. More primary research in these fields is needed so that future guidelines may address these issues, too.


Assuntos
Broncoscopia , Guias como Assunto , Adulto , Analgésicos Opioides/administração & dosagem , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Dióxido de Carbono/química , Sedação Consciente/métodos , Humanos , Hipercapnia/prevenção & controle , Midazolam/administração & dosagem , Segurança do Paciente
9.
Vet Anaesth Analg ; 47(4): 537-546, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32381351

RESUMO

OBJECTIVE: To evaluate agreement with PaCO2 of two low sampling rate sidestream capnometers and a mainstream capnometer in rabbits and the effect of using high fresh gas flow from a Bain coaxial breathing system. STUDY DESIGN: Prospective, crossover study. ANIMALS: A total of 10 New Zealand White rabbits weighing 3.4 ± 0.3 kg [mean ± standard deviation (SD)]. METHODS: Two sidestream analyzers (Viamed VM-2500-S and Capnostream 35) with a sampling rate of 50 mL minute-1 and a mainstream capnometer (Capnostat 5) were tested. All capnometers used infrared spectroscopy and advanced microprocessor technology. Rabbits were anesthetized and intubated with noncuffed endotracheal tubes of 3 mm internal diameter and adequate seal. A sidestream sampling adapter or the mainstream capnometer was attached to the endotracheal tube and connected to a Bain coaxial breathing system. Oxygen (1.5 L minute-1) delivered sevoflurane to maintain anesthesia. An auricular artery catheter allowed blood sampling for PaCO2 analysis corrected to rectal temperature. Inspired and end-tidal carbon dioxide (Pe'CO2) measurements were recorded during blood sample withdrawal. From each rabbit, 10 paired PaCO2/Pe'CO2 measurements were obtained. Each rabbit was recovered from anesthesia and was anesthetized again with an alternate capnometer after 1 week. Data were analyzed using Bland-Altman and two-way anova for repeated measures. RESULTS: Analysis included 100 paired samples. Negative bias reflects underestimation of PaCO2. Bland-Altman mean (±1.95 SD) was -16.7 (-35.2 to 1.8) mmHg for Capnostat 5, -27.9 (-48.6 to -7.2) mmHg for Viamed, and -18.1 (-34.3 to -1.9) mmHg for Capnostream. Viamed PaCO2-Pe'CO2 gradient was greater than other two capnometers. CONCLUSIONS: All three capnometers underestimated PaCO2. Capnostat 5 and Capnostream performed similarly. CLINICAL RELEVANCE: These capnometers underestimated PaCO2 in spontaneously breathing rabbits anesthetized using a Bain coaxial breathing system with high fresh gas flows.


Assuntos
Capnografia/veterinária , Anestesia/veterinária , Animais , Capnografia/instrumentação , Estudos Cross-Over , Feminino , Intubação Intratraqueal/veterinária , Estudos Prospectivos , Coelhos
10.
Sleep Breath ; 23(3): 899-906, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31025273

RESUMO

PURPOSE: Severe manifestations of facioscapulohumeral dystrophy (FSHD) may be associated with sleep-disordered breathing (SDB), including obstructive sleep apnea (OSA) and nocturnal hypoventilation (NH), but prevalence data are scarce. In patients with respiratory muscle weakness, detection of NH can be facilitated by transcutaneous capnometry, but respective data derived from FSHD patients have not yet been published. METHODS: We collected sleep studies and capnometry recordings from 31 adult patients with genetically confirmed FSHD who were admitted to our sleep laboratory for first-ever evaluation of sleep-related breathing. Indications for admission included non-restorative sleep, morning headache, or excessive daytime sleepiness. In addition, sleep studies were initiated if symptoms or signs of respiratory muscle weakness were present. Thirty-one subjects with insomnia served as controls for comparison of respiratory measures during sleep. RESULTS: In the FSHD group, 17/31 (55%) patients showed OSA and 8 (26%) had NH. NH would have been missed in 7/8 patients if only oximetry criteria of hypoventilation had been applied. Capnography results were correlated with disease severity as reflected by the Clinical Severity Score (CSS). Non-invasive ventilation (NIV) was started in 6 patients with NH and 3 individuals with OSA. Nocturnal continuous positive airway pressure was administered to 2 patients, and positional therapy was sufficient in 4 individuals. In patients initiated on NIV, nocturnal gas exchange already improved in the first night of treatment. CONCLUSIONS: SDB is common in adult patients with FSHD complaining of sleep-related symptoms. It may comprise OSA, NH, and most often, the combination of both. Sleep-related hypercapnia is associated with disease severity. Transcutaneous capnometry is superior to pulse oximetry for detection of NH.


Assuntos
Distrofia Muscular Facioescapuloumeral/epidemiologia , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/epidemiologia , Apneia Obstrutiva do Sono/epidemiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Prevalência
11.
Appl Psychophysiol Biofeedback ; 44(2): 97-102, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30539503

RESUMO

Capnometry guided respiratory interventions have shown promising results in the treatment of panic disorder, but mechanisms of change are not yet well-understood. The current study examined changes in end-tidal carbon dioxide (ETCO2), anxiety sensitivity, and perceived control as mediators of panic symptom change. Sixty-nine adults with panic disorder received 4 weeks of respiratory training, and panic symptom severity and potential mediators were assessed at Pre-treatment, Mid-treatment, Post-treatment, 2-month follow-up, and 12-month follow-up. Multilevel mediation analyses showed that changes in perceived control significantly mediated changes in panic disorder severity and that for individuals who were hypocapnic at pre-treatment, ETCO2 was a significant mediator of symptom outcome. Findings provide further evidence that changes in perceived control, and improvements in respiratory dysregulation for hypocapnic individuals specifically, underlie symptom improvement from capnometry guided respiratory intervention for panic disorder.


Assuntos
Exercícios Respiratórios , Hipocapnia/terapia , Transtorno de Pânico/terapia , Adulto , Idoso , Transtornos de Ansiedade/terapia , Escalas de Graduação Psiquiátrica Breve , Dióxido de Carbono/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
J Clin Monit Comput ; 31(1): 153-158, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26628269

RESUMO

Hyper or hypoventilation may have serious clinical consequences in critically ill patients and should be generally avoided, especially in neurosurgical patients. Therefore, monitoring of carbon dioxide partial pressure by intermittent arterial blood gas analysis (PaCO2) has become standard in intensive care units (ICUs). However, several additional methods are available to determine PCO2 including end-tidal (PETCO2) and transcutaneous (PTCCO2) measurements. The aim of this study was to compare the accuracy and reliability of different methods to determine PCO2 in mechanically ventilated patients on ICU. After approval of the local ethics committee PCO2 was determined in n = 32 ICU consecutive patients requiring mechanical ventilation: (1) arterial PaCO2 blood gas analysis with Radiometer ABL 625 (ABL; gold standard), (2) arterial PaCO2 analysis with Immediate Response Mobile Analyzer (IRMA), (3) end-tidal PETCO2 by a Propaq 106 EL monitor and (4) transcutaneous PTCCO2 determination by a Tina TCM4. Bland-Altman method was used for statistical analysis; p < 0.05 was considered statistically significant. Statistical analysis revealed good correlation between PaCO2 by IRMA and ABL (R2 = 0.766; p < 0.01) as well as between PTCCO2 and ABL (R2 = 0.619; p < 0.01), whereas correlation between PETCO2 and ABL was weaker (R2 = 0.405; p < 0.01). Bland-Altman analysis revealed a bias and precision of 2.0 ± 3.7 mmHg for the IRMA, 2.2 ± 5.7 mmHg for transcutaneous, and -5.5 ± 5.6 mmHg for end-tidal measurement. Arterial CO2 partial pressure by IRMA (PaCO2) and PTCCO2 provided greater accuracy compared to the reference measurement (ABL) than the end-tidal CO2 measurements in critically ill in mechanically ventilated patients patients.


Assuntos
Gasometria/métodos , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Unidades de Terapia Intensiva , Monitorização Fisiológica/métodos , Respiração Artificial/métodos , Adulto , Idoso , Dióxido de Carbono/sangue , Análise Custo-Benefício , Cuidados Críticos , Estado Terminal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Parcial , Testes Imediatos , Reprodutibilidade dos Testes , Tamanho da Amostra , Fatores de Tempo
14.
J Clin Monit Comput ; 30(5): 737-41, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26264607

RESUMO

An end-tidal CO2 monitor (capnometer) is used most often as a noninvasive substitute for PaCO2 in anesthesia, anesthetic recovery, and intensive care. Additionally, the wide spread on-site use of portable capnometers in emergency and trauma situations is now observed. This study was conducted to compare PaCO2 measurement between the EMMA™ portable-capnometer and sidestream capnometry. End-tidal CO2 (portable capnometer: EMMA™ capnograph, side stream capnometry module: Datex-Ohmeda S5 Anesthesia Monitor) levels were recorded at the time of arterial blood gas sampling of patients undergoing general anesthesia. Data were compared using the Bland and Altman method, and by evaluating the clinical significance performed by calculating the percent error (%). A total of 100 data were obtained from 35 patients. The bias of PaCO2 and portable capnometer was 6.0 mmHg, where the upper and lower limits of the agreement were 11.8 and 0.3 mmHg, respectively. The percent error was 18.0 %. The bias of side stream capnometry and portable capnometer was 2.2 mmHg, where the upper and the lower limits of the agreement were 6.0 and -1.6 mmHg, respectively. The percent error was 13.0 %. Significant differences between the PETCO2 and PaCO2 values of the EMMA™ portable-capnometer were not observed for patients undergoing general anesthesia. ClinicalTrials.gov identifier NCT02184728.


Assuntos
Gasometria , Capnografia/métodos , Dióxido de Carbono/sangue , Monitorização Fisiológica/métodos , Volume de Ventilação Pulmonar , Adulto , Idoso , Anestesia Geral/métodos , Cuidados Críticos/métodos , Feminino , Humanos , Hipercapnia/diagnóstico , Hipocapnia/diagnóstico , Masculino , Pessoa de Meia-Idade , Pressão Parcial , Reprodutibilidade dos Testes
15.
J Anesth ; 30(4): 644-52, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27130212

RESUMO

PURPOSE: The availability of difficult airway management (DAM) resources and the extent of capnometry use in Japanese intensive care units (ICUs) remained unclear. The purpose of this study was to clarify whether: (1) DAM resources were adequate, and (2) capnometry was routinely applied in Japanese ICUs. METHODS: This nationwide cross-sectional study was conducted from September 2015 to February 2016. All ICUs received a mailed questionnaire about their DAM resources and use of capnometry. Outcome measures were availability of: (1) 24-h in-house backup coverage; (2) a supraglottic airway device (SGA); (3) a dedicated DAM cart; and (4) surgical airway devices, and (5) routine use of capnometry to verify tube placement and for continuous monitoring of ventilator-dependent patients. The association between these outcomes and ICU type (academic, high-volume, closed, surgical) was also analyzed. RESULTS: Of the 289 ICUs, 196 (67.8 %) returned completed questionnaires. In-house backup coverage and surgical airway devices were highly available (89.3 and 95.9 %), but SGAs and dedicated DAM carts were not (60.2 and 60.7 %). The routine use of capnometry to confirm tube placement was reported by 55.6 % of the ICUs and was highest in closed ICUs (67.2 %, p = 0.03). The rate of continuous capnography monitoring was also 55.6 % and was highest in academic ICUs (64.5 %, p = 0.04). CONCLUSION: In Japanese ICUs, SGAs and dedicated DAM carts were less available, and capnometry was not universally applied either to confirm tube placement, or for continuous monitoring of ventilated patients. Our study revealed areas in need of improvement.


Assuntos
Manuseio das Vias Aéreas/métodos , Unidades de Terapia Intensiva , Intubação Intratraqueal/métodos , Capnografia , Estudos Transversais , Feminino , Humanos , Monitorização Fisiológica , Inquéritos e Questionários
16.
Heart Lung Circ ; 24(11): 1053-61, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26150002

RESUMO

Although high quality cardiopulmonary resuscitation is one of the most significant factors related to favourable outcome, its quality depends on many components, such as airway management, compression depth and chest recoil, hands-off time, and early defibrillation. The most common way of controlling the resuscitation efforts is monitoring of end-tidal carbon dioxide. The International Liaison Committee on Resuscitation suggests this method both for in-hospital and out-of-hospital cardiac arrest. However, despite the abundant human and animal studies supporting the usefulness of end-tidal carbon dioxide, its optimal values during cardiopulmonary resuscitation remain controversial. In this review, the advantages and effectiveness of end-tidal carbon dioxide during cardiopulmonary resuscitation are discussed and specific target values are suggested based on the available literature.


Assuntos
Capnografia/métodos , Dióxido de Carbono/sangue , Reanimação Cardiopulmonar/métodos , Monitorização Fisiológica/métodos , Adulto , Humanos
17.
Toxicol Appl Pharmacol ; 278(1): 85-90, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24747805

RESUMO

In non-smokers, ozone (O3) inhalation causes decreases in forced expiratory volume (FEV1) and dead space (VD) and increases the slope of the alveolar plateau (SN). We previously described a population of smokers with a limited smoking history that had enhanced responsiveness to brief O3 boluses and aimed to determine if responsiveness to continuous exposure was also enhanced. Thirty smokers (19M, 11F, 24±4 years, 6±4 total years smoking,4±2 packs/week) and 30 non-smokers (17M, 13F, 25±6 years) exercised for 1h on a cycle ergometer while breathing 0.30ppm O3. Smokers and non-smokers were equally responsive in terms of FEV1 (-9.5±1.8% vs -8.7±1.9%). Smokers alone were responsive in terms of VD (-6.1±1.2%) and SN (9.1±3.4%). There was no difference in total delivered dose. Dead space ventilation (VD/VT) was not initially different between the two groups, but increased in the non-smokers (16.4±2.8%) during the exposure, suggesting that the inhaled dose may be distributed more peripherally in smokers. We also conclude that these cigarette smokers retain their airway responsiveness to O3 and, uniquely, experience changes in VD that lead to heterogeneity in airway morphometry and an increase in SN.


Assuntos
Pulmão/efeitos dos fármacos , Ozônio/efeitos adversos , Respiração/efeitos dos fármacos , Fumar/efeitos adversos , Adulto , Capnografia , Estudos de Casos e Controles , Exercício Físico , Teste de Esforço , Feminino , Volume Expiratório Forçado , Humanos , Exposição por Inalação/efeitos adversos , Pulmão/fisiopatologia , Masculino , Espaço Morto Respiratório , Fumar/fisiopatologia , Espirometria , Volume de Ventilação Pulmonar , Fatores de Tempo , Capacidade Vital , Adulto Jovem
18.
J Am Coll Emerg Physicians Open ; 5(3): e13170, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38680203

RESUMO

Objective: The bias of capnometry (ETCO2) and venous carbon dioxide (vpCO2) among pediatric emergency department (PED) patients triaged to critical care areas is unknown. We aimed to explore correlations and bias between ETCO2 and vpCO2¸and identify predictors of bias. Methods: This was an observational, video-based, retrospective study comparing ETCO2 and vpCO2. Pediatric patients with simultaneous ETCO2 and vpCO2 data were included. Our primary aim utilized linear regressions to determine correlations and Bland-Altman analysis to assess bias. Our secondary aim utilized multiple regression to identify clinical covariates contributing to bias. Covariates included age, respiratory rate, heart rate, mean arterial blood pressure, capnometry interface, PED diagnosis, and PED disposition. Results: A total of 200 PED patients with ETCO2 and vpCO2 data were included. The median (interquartile range [IQR]) ETCO2, vpCO2, and ΔCO2 in mmHg were 38 (32, 46), 49 (41, 61), and 11 (4, 20), respectively. ETCO2 (r = 0.76) and ΔCO2 (r = 0.71) were highly correlated with vpCO2. The mean bias between ETCO2 and vpCO2 was -14.1 mmHg (95% confidence interval [CI], -41.9 -13.7). The bias between ETCO2 and vpCO2 increased at higher values of each measure. ETCO2 sampling interface was the only independent predictor of vpCO2 in our multivariate analysis. Patients requiring bag-valve mask (BVM) ventilation had the highest median bias between ETCO2 and vpCO2 (29 mmHg, IQR 15, 37). Conclusion: ETCO2 and vpCO2 were highly correlated. However, bias increased at higher levels of both ETCO2 and vpCO2. Among PED patients, ETCO2's ability to approximate vpCO2 diminishes with worsening hypercarbic respiratory failure.

19.
Resuscitation ; 189: 109863, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302687

RESUMO

AIM: To analyse the association between donor capnometry data and the short-term evolution of kidney grafts in cases of uncontrolled donation after circulatory death (uDCD). METHOD: We used an ambispective observational study design, conducted in the Community of Madrid between January and December 2019, inclusive. Patients who suffered out-of-hospital cardiac arrest (CA) with no response to advanced cardiopulmonary resuscitation (CPR) were selected as potential donors. Donor capnometry levels were measured at the start, midpoint and transfer to hospital then compared with indicators of renal graft evolution. RESULTS: The initial selection included 34 possible donors, of which 12 (35.2%) were viable donors from whom 22 (32.3%) kidneys were recovered. There was a correlation between the highest capnometry values and less need for post-transplant dialysis (≥24 mmHg, p < 0.017), fewer dialysis sessions and fewer days to recover correct renal function (Rho -0.47, p < 0.044). There was a significant inverse correlation between the capnometry values at transfer and 1-month post-transplant creatinine levels (Rho -0.62, p < 0.033). There were no significant differences between the capnometry values at transfer and primary nonfunction (PNF) or warm ischaemia time. One-year patient survival was 100% for patient receiving organ donation, while graft survival was 95%. CONCLUSIONS: Capnometry levels at transfer are a useful predictor of the short-term function and viability of kidney transplants from uncontrolled donations after circulatory death.


Assuntos
Transplante de Rim , Transplante de Órgãos , Obtenção de Tecidos e Órgãos , Humanos , Rim , Doadores de Tecidos , Sobrevivência de Enxerto , Morte
20.
Resuscitation ; 174: 83-90, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35101599

RESUMO

AIMS: The end-tidal carbon dioxide (ETCO2) is frequently measured in cardiac arrest (CA) patients, for management and for predicting survival. Our goal was to study the PaCO2 and ETCO2 in hypothermic cardiac arrest patients. METHODS: We included patients with refractory CA assessed for extracorporeal cardiopulmonary resuscitation. Hypothermic patients were identified from previously prospectively collected data from Poland, France and Switzerland. The non-hypothermic CA patients were identified from two French cohort studies. The primary parameters of interest were ETCO2 and PaCO2 at hospital admission. We analysed the data according to both alpha-stat and pH-stat strategies. RESULTS: We included 131 CA patients (39 hypothermic and 92 non-hypothermic). Both ETCO2 (p < 0.001) and pH-stat PaCO2 (p < 0.001) were significantly lower in hypothermic compared to non-hypothermic patients, which was not the case for alpha-stat PaCO2 (p = 0.15). The median PaCO2-ETCO2 gradient was greater for hypothermic compared to non-hypothermic patients when using the alpha-stat method (46 mmHg vs 30 mmHg, p = 0.007), but not when using the pH-stat method (p = 0.10). Temperature was positively correlated with ETCO2 (p < 0.01) and pH-stat PaCO2 (p < 0.01) but not with alpha-stat PaCO2 (p = 0.5). The ETCO2 decreased by 0.5 mmHg and the pH-stat PaCO2 by 1.1 mmHg for every decrease of 1° C of the temperature. The proportion of survivors with an ETCO2 ≤ 10 mmHg at hospital admission was 45% (9/25) for hypothermic and 12% (2/17) for non-hypothermic CA patients. CONCLUSIONS: Hypothermic CA is associated with a decrease of the ETCO2 and pH-stat PaCO2 compared with non-hypothermic CA. ETCO2 should not be used in hypothermic CA for predicting outcome.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Hipotermia Induzida , Hipotermia , Dióxido de Carbono , Humanos , Concentração de Íons de Hidrogênio , Hipotermia/terapia