RESUMO
Interpretive artificial intelligence (AI) tools are poised to change the future of radiology. However, certain pitfalls may pose particular challenges for optimal AI interpretative performance. These include anatomic variants, age-related changes, postoperative changes, medical devices, image artifacts, lack of integration of prior and concurrent imaging examinations and clinical information, and the satisfaction-of-search effect. Model training and development should account for such pitfalls to minimize errors and optimize interpretation accuracy. More broadly, AI algorithms should be exposed to diverse and complex training datasets to yield a holistic interpretation that considers all relevant information beyond the individual examination. Successful clinical deployment of AI tools will require that radiologist end users recognize these pitfalls and other limitations of the available models. Furthermore, developers should incorporate explainable AI techniques (e.g., heat maps) into their tools, to improve radiologists' understanding of model outputs and to enable radiologists to provide feedback for guiding continuous learning and iterative refinement. In this article, we provide an overview of common pitfalls that radiologists may encounter when using interpretive AI products in daily practice. We present how such pitfalls lead to AI errors and offer potential strategies that AI developers may use for their mitigation.
RESUMO
This study demonstrates that GPT-4V outperforms GPT-4 across radiology subspecialties in analyzing 207 cases with 1312 images from the Radiological Society of North America Case Collection.
Assuntos
Radiologia , Radiologia/métodos , Radiologia/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/métodosRESUMO
Prenatal exposure to environmental factors may play an important role in the aetiopathogenesis of autism spectrum disorder (ASD). We aim to investigate the potential effects of low-dose x-rays from dental diagnostic x-rays on neurodevelopment and molecular mechanisms associated with ASD in developing zebrafish embryos. Zebrafish embryos were divided into four groups and exposed using a dental x-ray unit: control, 0.08, 0.15 and 0.30 seconds, which are exemplary exposure settings for periapical imaging. These exposure times were measured as 7.17, 23.17 and 63.83 mSv using optical stimulated luminescence dosimeters. At the end of 72 hours post-fertilization, locomotor activity, oxidant-antioxidant status, and acetylcholine esterase (AChE) activity were analyzed. Expression of genes related to apoptosis (bax, bcl2a, p53), neurogenesis (α1-tubulin, syn2a, neurog1, elavl3) and ASD (eif4eb, adsl2a, shank3) was determined by RT-PCR. Even at reduced doses, developmental toxicity was observed in three groups as evidenced by pericardial edema, yolk sac edema and scoliosis. Deleterious effects of dental x-rays on neurogenesis through impaired locomotor activity, oxidative stress, apoptosis and alterations in genes associated with neurogenesis and ASD progression were more pronounced in the 0.30s exposure group. Based on these results we suggest that the associations between ASD and low-dose ionizing radiation need a closer look.
RESUMO
Medical imaging instrumentation design and construction is based on radiation sources and radiation detectors/sensors. This review focuses on the detectors and sensors of medical imaging systems. These systems are subdivided into various categories depending on their structure, the type of radiation they capture, how the radiation is measured, how the images are formed, and the medical goals they serve. Related to medical goals, detectors fall into two major areas: (i) anatomical imaging, which mainly concerns the techniques of diagnostic radiology, and (ii) functional-molecular imaging, which mainly concerns nuclear medicine. An important parameter in the evaluation of the detectors is the combination of the quality of the diagnostic result they offer and the burden of the patient with radiation dose. The latter has to be minimized; thus, the input signal (radiation photon flux) must be kept at low levels. For this reason, the detective quantum efficiency (DQE), expressing signal-to-noise ratio transfer through an imaging system, is of primary importance. In diagnostic radiology, image quality is better than in nuclear medicine; however, in most cases, the dose is higher. On the other hand, nuclear medicine focuses on the detection of functional findings and not on the accurate spatial determination of anatomical data. Detectors are integrated into projection or tomographic imaging systems and are based on the use of scintillators with optical sensors, photoconductors, or semiconductors. Analysis and modeling of such systems can be performed employing theoretical models developed in the framework of cascaded linear systems analysis (LCSA), as well as within the signal detection theory (SDT) and information theory.
Assuntos
Diagnóstico por Imagem , Humanos , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Razão Sinal-Ruído , Medicina Nuclear/instrumentaçãoRESUMO
Radiomics represents the science of extracting and analyzing a multitude of quantitative features from medical imaging, revealing the quantitative potential of radiologic images. This scientific review aims to provide radiologists with a comprehensive understanding of radiomics, emphasizing its principles, applications, challenges, limits, and prospects. The limitations of standardization in current scientific production are analyzed, along with possible solutions proposed by some of the referenced papers. As the continuous evolution of medical imaging is ongoing, radiologists must be aware of new perspectives to play a central role in patient management.
RESUMO
Immediate and strategic action is needed to improve environmental sustainability and reduce the detrimental effects of climate change. Climate change is already adversely affecting the health of Canadians related to worsening air pollution and wildfire smoke, increasing frequency and intensity of extreme weather events, and expansion of vector-borne and infectious illnesses. On one hand, radiology contributes to the climate crisis by generating greenhouse gas emissions and waste during the production, manufacture, transportation, and use of medical imaging equipment and supplies. On the other hand, radiology departments are also susceptible to equipment and infrastructure damage from flooding, extreme temperatures, and power failures, as well as workforce shortages due to injury and illness, potentially disrupting radiology services and increasing costs. The Canadian Association of Radiologists' (CAR) advocacy for environmentally sustainable radiology in Canada encompasses both minimizing the detrimental effects that delivery of radiology services has on the environment and optimizing the resilience of radiology departments to increasing health needs and changing patterns of disease on imaging related to climate change. This statement provides specific recommendations and pathways to help guide radiologists, medical imaging leadership teams, industry partners, governments, and other key stakeholders to transition to environmentally sustainable, net-zero, and climate-resilient radiology organizations. Specific consideration is given to unique aspects of medical imaging in Canada. Finally, environmentally sustainable radiology programs, policies, and achievements in Canada are highlighted.
RESUMO
BACKGROUND: Acute myeloid leukemia (AML) is the most common type of acute leukemia in adults. Bone marrow computed tomography (CT) attenuation may increase in patients with myeloproliferative disorders; however, the actual threshold CT attenuation value predictive of myeloproliferative has not been reported. PURPOSE: To determine whether the unenhanced CT attenuation value of the bone marrow may be useful for predicting AML. MATERIAL AND METHODS: We retrospectively analyzed patients with AML (n = 56) who underwent unenhanced CT before treatment, and age- and sex-matched controls without any hematologic disease. For each patient, the CT attenuation value (HU) of the iliac bone was measured and compared between the two groups. Receiver operating characteristic (ROC) curve analysis was used to define the cutoff value for predicting AML on all patients, and only on late elderly patients (aged ≥75 years). RESULTS: Patients with AML showed higher bone marrow CT attenuation value (131.4 ± 58.3 vs. 53.9 ± 67.2 HU; P < 0.001), compared to the controls. The sensitivity and specificity for the diagnosis of AML in all patients were 78.6% and 80.4%, respectively, at a threshold value of 90 HU, whereas they were 83.3% and 91.7%, respectively, at 40 HU in late elderly patients. CONCLUSION: The iliac bone CT attenuation value was elevated in patients with AML and may be useful for predicting AML.
Assuntos
Medula Óssea , Leucemia Mieloide Aguda , Adulto , Idoso , Humanos , Medula Óssea/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Sensibilidade e Especificidade , Leucemia Mieloide Aguda/diagnóstico por imagemRESUMO
PURPOSE OF THE STUDY: To compare the relationships between two CT derived sarcopenia assessment methods, and compare their relationship with inter-rater and intrarater validations and colorectal surgical outcomes. STUDY DESIGN: 157 CT scans were identified across Leeds Teaching Hospitals National Health Service Trust for patients undergoing colorectal cancer surgery. 107 had body mass index data available, required to determine sarcopenia status. This work explores the relationship between sarcopenia, as measured by both total cross sectional-area (TCSA) and psoas-area (PA) and surgical outcomes. All images were assessed for inter-rater and intrarater variability for both TCSA and PA methods of sarcopenia identification. The raters included a radiologist, an anatomist and two medical students. RESULTS: Prevalence of sarcopenia was different when measured by PA (12.2%-22.4%) in comparison to TCSA (60.8%-70.1%). Strong correlation exists between muscle areas in both TCSA and PA measures, however, there were significant differences between methods after the application of method-specific cut-offs. There was substantial agreement for both intrarater and inter-rater comparisons for both TCSA and PA sarcopenia measures. Outcome data were available for 99/107 patients. Both TCSA and PA have poor association with adverse outcomes following colorectal surgery. CONCLUSIONS: CT-determined sarcopenia can be identified by junior clinicians, those with anatomical understanding and radiologists. Our study identified sarcopenia to have a poor association with adverse surgical outcomes in a colorectal population. Published methods of identifying sarcopenia are not translatable to all clinical populations. Currently available cut-offs require refinement for potential confounding factors, to provide more valuable clinical information.
Assuntos
Neoplasias Colorretais , Sarcopenia , Humanos , Sarcopenia/diagnóstico por imagem , Sarcopenia/epidemiologia , Sarcopenia/complicações , Estudos Retrospectivos , Variações Dependentes do Observador , Estudos Transversais , Medicina Estatal , Tomografia Computadorizada por Raios X/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgiaRESUMO
BACKGROUND: As functional changes precede structural changes in dementia, we aimed to elucidate changes on cerebral perfusion CT (PCT) for early diagnosis of dementia; and to differentiate Alzheimer's disease (AD) from vascular dementia (VaD). We also aimed to study correlation between Montreal Cognitive Assessment (MOCA) score and PCT parameters. METHODS: We conducted a prospective case-control study enrolling 25 dementia patients (15 cases of VaD, 10 cases of AD) and 25 age-matched controls. PCT was performed on a 256-slice CT scanner. Using perfusion software, colour maps were generated for cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time and time-to-peak. These colour maps were first visually inspected for any abnormalities. Subsequently, quantitative assessment of perfusion parameters was done using symmetrical freehand region of interests drawn in bilateral frontal, temporal, parietal regions, basal ganglia and hippocampi. RESULTS: Strategic infarcts were present in 93.3% cases and white matter ischaemic changes in 100% cases of VaD. A global reduction in CBF and CBV was also observed in cases of VaD; whereas these parameters were significantly lower mainly in temporoparietal regions and hippocampi of patients with AD. There was significant positive correlation between MOCA score and various perfusion parameters in both forms of dementia. CONCLUSION: PCT is a reliable imaging modality for early diagnosis of dementia and in differentiating VaD from AD. As perfusion parameters show positive correlation with MOCA score, they could be used as a surrogate marker of cognitive status in the follow-up of patients with dementia.
Assuntos
Doença de Alzheimer , Encéfalo , Humanos , Encéfalo/diagnóstico por imagem , Estudos de Casos e Controles , Prognóstico , Tomografia Computadorizada por Raios X/métodos , Doença de Alzheimer/diagnóstico por imagem , PerfusãoRESUMO
MRI is an important and widely used imaging modality for clinical diagnosis. This article provides a concise discussion of the basic principles of MRI physics for non-radiology clinicians, with a general explanation of the fundamentals of signal generation and image contrast mechanisms. Common pulse sequences, tissue suppression techniques and use of gadolinium contrast with relevant clinical applications are presented. Knowledge of these concepts would provide an appreciation of how MR images are acquired and interpreted to facilitate interdisciplinary understanding between radiologists and referring clinicians.
Assuntos
Imageamento por Ressonância Magnética , Física , Humanos , Imageamento por Ressonância Magnética/métodosRESUMO
The human liver exhibits variable characteristics and anatomical information, which is often ambiguous in radiological images. Machine learning can be of great assistance in automatically segmenting the liver in radiological images, which can be further processed for computer-aided diagnosis. Magnetic resonance imaging (MRI) is preferred by clinicians for liver pathology diagnosis over volumetric abdominal computerized tomography (CT) scans, due to their superior representation of soft tissues. The convenience of Hounsfield unit (HoU) based preprocessing in CT scans is not available in MRI, making automatic segmentation challenging for MR images. This study investigates multiple state-of-the-art segmentation networks for liver segmentation from volumetric MRI images. Here, T1-weighted (in-phase) scans are investigated using expert-labeled liver masks from a public dataset of 20 patients (647 MR slices) from the Combined Healthy Abdominal Organ Segmentation grant challenge (CHAOS). The reason for using T1-weighted images is that it demonstrates brighter fat content, thus providing enhanced images for the segmentation task. Twenty-four different state-of-the-art segmentation networks with varying depths of dense, residual, and inception encoder and decoder backbones were investigated for the task. A novel cascaded network is proposed to segment axial liver slices. The proposed framework outperforms existing approaches reported in the literature for the liver segmentation task (on the same test set) with a dice similarity coefficient (DSC) score and intersect over union (IoU) of 95.15% and 92.10%, respectively.
Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Abdome/diagnóstico por imagem , Fígado/diagnóstico por imagemRESUMO
The relationship between various factors predisposing to the formation of spondylolisthesis, including degenerative spondylolisthesis, has been analyzed by many authors. However, not all observations are consistent. In this review, we identified factors whose impact on the prevalence of spondylolisthesis was most often mentioned in the literature. These included gender, age, bone mineral density, ethnic origin, and oophorectomy. The results were inclusive in terms of physical activity, pregnancy status, and use of hormone replacement therapy. Associations between diabetes and smoking were very poorly marked. The literature so far has identified a number of factors significantly affecting the incidence of degenerative spondylolisthesis. These include age, gender, body weight, ethnic origin, bone mineral density, and hormonal balance. Radiological parameters, which include iliac crest, pelvic tilt, pelvic incidence, sacral slope, and lumbar lordosis, may also be of great importance for assessing changes in the occurrence and progression. However, the authors do not agree on the real significance of individual factors. The aim of this review was to identify the factors predisposing to the formation of degenerative spondylolisthesis, the importance of which has been suggested in the current literature. The systematization of knowledge in this field can allow a more accurate adjustment of the treatment plan for each patient affected by this condition.
Assuntos
Espondilolistese , Animais , Feminino , Humanos , Gravidez , Espondilolistese/complicações , Espondilolistese/epidemiologia , Peso Corporal , Densidade Óssea , Etnicidade , Exercício FísicoRESUMO
BACKGROUND: Most women undergoing screening examinations in the U.S. do not receive immediate results and for many this results in increased stress, inconvenience, delayed diagnosis, and potential loss to follow-up. OBJECTIVE: To study the impact of same appointment mammogram results on breast cancer screening experience and patient satisfaction. MATERIALS AND METHODS: A 6-question survey with questions focused on breast cancer screening experience with our new service of same appointment mammogram results was distributed to 200 patients, with 185 patients returning their responses. Patients evaluated their current experience on receiving their screening results during the same appointment with their prior breast cancer screening experience. Patients who did not respond to their satisfaction score either before or after same appointment results were excluded from the patient cohort analyzing satisfaction score. Remaining questions were analyzed separately as additional satisfaction assessment tools. RESULTS: About 48% of the patients indicated an improvement in their screening experience with same appointment mammography results service, while 47% of the patients reported no significant difference in their experience. CONCLUSION: Although not statistically significant, same appointment mammogram results were able to make a positive impact on breast cancer screening experience among 48% of the patients. Further research elucidating barriers to screening and other ways to improve patient satisfaction will be required to increase breast cancer screening compliance.
Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/prevenção & controle , Feminino , Humanos , Mamografia , Programas de Rastreamento , Satisfação Pessoal , Melhoria de QualidadeRESUMO
BACKGROUND: This study determines the diagnostic utility of lung ultrasonography (LUS) in a medical ward in a developing country. In a low resource country like India, we hope that use of lung ultrasound in primary and secondary hospitals will assist in earlier and better bedside diagnosis. METHODS: This prospective diagnostic study was done to test the diagnostic accuracy of LUS against a composite reference standard, which included clinical history and examination, basic laboratory investigations, imaging and the diagnosis at discharge. We evaluated 321 consecutive patients, admitted in our medical wards with an LUS within 24 hours of the chest radiograph being done. FINDINGS: Between August 2016 and August 2017, we enrolled 321 patients. The sensitivity and specificity of the LUS for all pathologies were found to be 82.5% (76.50 to 87.20) and 78.2% (69.09 to 85.26) respectively. A subgroup analysis including the patients in whom CT was part of the composite reference standard showed sensitivity and specificity of 87.9% and 92.9% for all lung pathologies. It was found that there was superior sensitivity and specificity of LUS compared with chest radiograph in a subgroup analysis of pulmonary oedema and acute respiratory distress syndrome (ARDS). INTERPRETATION: We found that the LUS was better than chest radiograph and as good as CT in most pathologies, especially pulmonary oedema and ARDS. We believe that training in the basics of bedside LUS must be part of the medical curriculum and a low-cost ultrasound machine must be made available in medical wards, so that clinical diagnosis can be supplemented with this tool. In a low resource setting like India, where access to chest radiograph and CT may be difficult particularly in a rural setup, expertise in LUS would be helpful in easy bedside diagnosis and saving cost on a CT scan.
RESUMO
BACKGROUND: As functional changes precede structural changes in dementia, we aimed to elucidate changes on cerebral perfusion CT (PCT) for early diagnosis of dementia; and to differentiate Alzheimer's disease (AD) from vascular dementia (VaD). We also aimed to study correlation between Montreal Cognitive Assessment (MOCA) score and PCT parameters. METHODS: We conducted a prospective case-control study enrolling 25 dementia patients (15 cases of VaD, 10 cases of AD) and 25 age-matched controls. PCT was performed on a 256-slice CT scanner. Using perfusion software, colour maps were generated for cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time and time-to-peak. These colour maps were first visually inspected for any abnormalities. Subsequently, quantitative assessment of perfusion parameters was done using symmetrical freehand region of interests drawn in bilateral frontal, temporal, parietal regions, basal ganglia and hippocampi. RESULTS: Strategic infarcts were present in 93.3% cases and white matter ischaemic changes in 100% cases of VaD. A global reduction in CBF and CBV was also observed in cases of VaD; whereas these parameters were significantly lower mainly in temporoparietal regions and hippocampi of patients with AD. There was significant positive correlation between MOCA score and various perfusion parameters in both forms of dementia. CONCLUSION: PCT is a reliable imaging modality for early diagnosis of dementia and in differentiating VaD from AD. As perfusion parameters show positive correlation with MOCA score, they could be used as a surrogate marker of cognitive status in the follow-up of patients with dementia.
RESUMO
INTRODUCTION: The superior labial artery (SLA) is a facial artery (FA) that drains into the peri-oral region (dangerous area of face). Owing to the recent rise in the demand for reconstructive procedures and filler injections in this region, it is important to understand its arterial topography. This paper aims to study the embranchment pattern of the labial arteries in the eastern Indian population. METHOD: An observational study using conventional dissection and dry dye injection methods was conducted to visualize the facial and superior labial arteries in 56 hemifaces. The origin, morphometry (length and diameter), branching pattern, and termination of the arteries were recorded and compared with the existing data. RESULTS: Two hemifaces were excluded from analysis (vessels damaged in dissection); in the remaining 54, a single SLA was present in all samples originating at a mean distance of 1.29 ± 0.32 cm from oral commissure (68.51% originating above). Lee type II (independent SLA giving off alar branch) was the predominant pattern (56.2%), followed by type I (independent SLA and alar branches, 33%) and type III (FA terminating as SLA, 10.8%). The average length of SLA was 4.75 ± 1.28 cm and 4.56 ± 0.78 cm on the right and left sides, respectively. CONCLUSION: The SLA is highly variable in occurrence, course, and depth, sometimes even occurring unilaterally; therefore, any intervention in this region should be done with caution. Since the SLA was not found subcutaneously at the vermillion border, the intradermal and the subcutaneous injections used here are relatively safer. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Artérias , Lábio , Humanos , Lábio/cirurgia , Cadáver , Artérias/anatomia & histologia , Face/irrigação sanguínea , Injeções SubcutâneasRESUMO
BACKGROUND: Patients presenting with acute abdominal pain often undergo a computed tomography (CT) scan as part of their diagnostic workup. We investigated the relationship between availability, timeliness, and interpretation of CT imaging and outcomes for life-threatening intra-abdominal diseases or "acute abdomen," in older Americans. METHODS: Data from a 2015 national survey of 2811 hospitals regarding emergency general surgery structures and processes (60.1% overall response, n = 1690) were linked to 2015 Medicare inpatient claims data. We identified beneficiaries aged ≥65 admitted emergently with a confirmatory acute abdomen diagnosis code and operative intervention on the same calendar date. Multivariable regression models adjusted for significant covariates determined odds of complications and mortality based on CT resources. RESULTS: We identified 9125 patients with acute abdomen treated at 1253 hospitals, of which 78% had ≥64-slice CT scanners and 85% had 24/7 CT technicians. Overnight CT reads were provided by in-house radiologists at 14% of hospitals and by teleradiologists at 66%. Patients were predominantly 65-74 y old (43%), white (88%), females (60%), and with ≥3 comorbidities (67%) and 8.6% died. STAT radiology reads by a board-certified radiologist rarely/never available in 2 h was associated with increased odds of systemic complication and mortality (adjusted odds ratio 2.6 [1.3-5.4] and 2.3 [1.1-4.8], respectively). CONCLUSIONS: Delays obtaining results are associated with adverse outcomes in older patients with acute abdomen. This may be due to delays in surgical consultation and time to source control while waiting for imaging results. Processes to ensure timely interpretation of CT scans in patients with abdominal pain may improve outcomes in high-risk patients.
Assuntos
Abdome Agudo/diagnóstico por imagem , Abdome Agudo/mortalidade , Complicações Pós-Operatórias/epidemiologia , Radiologia/estatística & dados numéricos , Tomografia Computadorizada por Raios X , Abdome Agudo/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estados Unidos/epidemiologiaRESUMO
Psoriasis (PsO) is a chronic skin disease. This study aims to evaluate clinical and subclinical response to calcipotriol+betamethasone foam, in patients with PsO, comparing, for the first time, data from microvascular ultrasound (MicroV) and shear wave elastography (SWE) with Psoriasis Area and Severity Index (PASI). METHODS: Between November 2018 and April 2019 in Tor Vergata Hospital (Roma, Italy), we enrolled 26 patients with PsO who were ageds 20-75 years, with PASI score ≥4, candidated for calcipotriol+betamethasone foam treatment. They underwent MicroV and SWE evaluation at baseline (T0) and after 4 weeks of treatment (T4). Clinical follow-up was carried on at T4, T8 and T12. Student's t-test (p values<0.05 statistically significant) was used to compare SWE and PASI values. RESULTS: At T0, SWE stiffness values of target plaques (61.5% on elbows, 23% knees, 7.7% sacrum,7.7% legs) were significantly higher than values under healthy skin. At T4, all patients showed a significant reduction of PASI; MicroV showed reduction in vascularisation of responsive plaques in 85% of cases, only in 15%, the vascularisation degree remained stable; and SWE values of target plaques were significantly lower compared with T0. Only in 7.7%, there was a relapse at T12. CONCLUSIONS: Calcipotriol+betamethasone foam is a very effective topical treatment in a short-medium term follow-up in patients with PsO. MicroV and SWE evaluate response to treatment (in term of plaque vascularisation and stiffness), so they could represent promising early indicators of therapeutic response and help the physician to establish a better clinical-therapeutic management of patients with PsO.
Assuntos
Anti-Inflamatórios/uso terapêutico , Betametasona/uso terapêutico , Calcitriol/análogos & derivados , Fármacos Dermatológicos/uso terapêutico , Psoríase/diagnóstico por imagem , Psoríase/tratamento farmacológico , Administração Tópica , Adulto , Idoso , Calcitriol/uso terapêutico , Quimioterapia Combinada , Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia , Adulto JovemRESUMO
The environmental impact of training has been poorly recognised for many years. With the emergence of high-profile climate activists and a wider appreciation of the need for sustainable healthcare, training within radiology can no longer be excused from its responsibility to consider the environment in its actions. In this paper, we aim to evaluate the environmental impact of the travel undertaken by trainees within the Peninsula training programme, with the aim of developing practices and providing suggestions (evidence-based where possible) on how to improve the impact on the environment of trainee travel. We envisage that many of the lessons and suggestions may be transferrable to other training schemes in the UK and further afield. During the early months of 2020, in addition to the environmental crisis, COVID-19 escalated to a pandemic resulting in the alteration of working practices across the UK (and the rest of the world). This led to many environmentally beneficial working practices being adopted in Radiology in the South West Peninsula Deanery, and throughout this paper we have evaluated these changes and used our collective experience of these to inform our suggestions on how to improve the environmental sustainability of Medical and Radiological training.
Assuntos
Educação de Pós-Graduação em Medicina/organização & administração , Meio Ambiente , Radiologia/educação , Viagem , COVID-19/epidemiologia , COVID-19/prevenção & controle , COVID-19/transmissão , Controle de Doenças Transmissíveis/organização & administração , Educação a Distância , Humanos , Telerradiologia , Reino UnidoRESUMO
For technical and radioprotection reasons, it has become essential to develop new dosimetric tools adapted to the specificities of computed tomography (CT) to ensure precise and efficient dosimetry since the current standards are not suitable for clinical use and for new CT technological evolution. Thanks to its many advantages, plastic scintillating fibers (PSF) is a good candidate for more accurate and personalized real-time dosimetry in computed tomography, and the company Fibermetrix has developed a new device named IVISCAN® based on this technology. In this study, we evaluated performances of IVISCAN® and associated uncertainties in terms of dose-rate dependence, angular dependence, stability with cumulative dose, repeatability, energy dependence, length dependence, and special uniformity in reference and clinical computed tomography beam qualities. For repeatability, the standard deviation is less than 0.039%, and the absolute uncertainty of repeatability lies between 0.017% and 0.025%. The deviation between IVISCAN® and the reference regarding energy dependence is less than 1.88% in clinical use. Dose rate dependence results show a maximum deviation under ±2%. Angular dependence standard deviation σ is 0.8%, and the absolute uncertainty was 1.6%. We observed 1% of variation every 50 Gy steps up to a cumulative dose of 500 Gy. Probe response was found to be independent of the PSF length with a maximum deviation ΔDsize < 2.7% between the IVISCAN® probe and the 1 cm PSF probe. The presented results demonstrated that IVISCAN® performances are in accordance with metrology references and the international standard IEC61674 relative to dosemeters used in X-ray diagnostic imaging and then make it an ideal candidate for real-time dosimetry in CT applications.