Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmology ; 131(2): 240-248, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069944

RESUMO

PURPOSE: To evaluate the current published literature on the utility of the 10-2 visual field (VF) testing strategy for the evaluation and management of early glaucoma, defined here as mean deviation (MD) better than -6 decibels (dB). METHODS: A search of the peer-reviewed literature was last conducted in June 2023 in the PubMed database. Abstracts of 986 articles were examined to exclude reviews and non-English-language articles. After inclusion and exclusion criteria were applied, 26 articles were selected, and the panel methodologist rated them for strength of evidence. Thirteen articles were rated level I, and 8 articles were rated level II. The 5 level III articles were excluded. Data from the 21 included articles were abstracted and reviewed. RESULTS: The central 12 locations on the 24-2 VF test grid lie within the central 10 degrees covered by the 10-2 VF test. In early glaucoma, defects detected within the central 10 degrees generally agree between the 2 tests. Defects within the central 10 degrees of the 24-2 VF test can predict defects on the 10-2 VF test, although the 24-2 may miss defects detected on the 10-2 VF test. In addition, results from the 10-2 VF test show better association with findings from OCT scans of the macular ganglion cell complex. Modifications of the 24-2 test that include extra test locations within the central 10 degrees improve detection of central defects found on 10-2 VF testing. CONCLUSIONS: Evidence to date does not support routine testing using 10-2 VF for patients with early glaucoma. However, early 10-2 VF testing may provide sufficient additional information for some patients, particularly those with a repeatable defect within the central 12 locations of the standard 24-2 VF test or who have inner retinal layer thinning on OCT scans of the macula. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Glaucoma , Oftalmologia , Humanos , Estados Unidos , Campos Visuais , Escotoma/diagnóstico , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual , Glaucoma/diagnóstico , Glaucoma/complicações , Pressão Intraocular
2.
Int Ophthalmol ; 44(1): 394, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39320616

RESUMO

PURPOSE: To evaluate the difference in ganglion cell layer (GCL) thickness on optical coherence tomography (OCT) and waveform on pattern electroretinography (PERG) among glaucoma suspects and healthy controls. METHODS: An analytical, cross-sectional study was done on 100 eyes of 50 subjects, equally divided in the glaucoma suspect and control group. Subjects with an asymmetrically increased vertical cup-to-disc ratio and without any perimetric change were taken as suspects, and subjects with normal findings were taken as controls. GCL thickness was evaluated on spectral domain OCT at 3 mm, 3.45 mm, and 6 mm centering the foveola, and P50, N95 wave forms were recorded according to the standard PERG protocol. RESULTS: In this study, we observed that the average GCL thickness is significantly less in glaucoma suspects at 3.45 mm (p = 0.045) and at 6 mm (p < 0.001) circle zone. On PERG, P50 amplitude was significantly low in glaucoma suspects in comparison to controls (p = 0.007). There was significantly increased implicit time for both P50 and N95 in glaucoma suspects (p < 0.001). For N95 amplitude, a non-significant (p = 0.127) difference was observed among the two groups. At 3.45 mm, average GCL thickness showed a weak negative correlation with N95 implicit time (r = - 0.286, p = 0.044), a weak positive correlation with P50 amplitude (r = 0.349, p = 0.013), and at 6 mm, a weak positive correlation with P50 amplitude (r = 0.311, p = 0.028) in glaucoma suspects. CONCLUSIONS: Analysing GCL thickness can help in the structural assessment of preperimetric glaucoma. PERG can be used as a valuable tool for the detection of ganglion cell dysfunction, even before cell loss.


Assuntos
Eletrorretinografia , Pressão Intraocular , Hipertensão Ocular , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Células Ganglionares da Retina/patologia , Estudos Transversais , Masculino , Feminino , Tomografia de Coerência Óptica/métodos , Eletrorretinografia/métodos , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/diagnóstico , Fibras Nervosas/patologia , Campos Visuais/fisiologia , Adulto , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Idoso
3.
Clin Exp Ophthalmol ; 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38093486

RESUMO

BACKGROUND: To appraise the quality of clinical practice guidelines for glaucoma suspects, and to assess their consistency for how a 'glaucoma suspect' is defined and their recommendations for treatment initiation for such individuals. METHODS: This study included all documents that self-identified as a 'guideline' and provided recommendation(s) for the clinical care of glaucoma suspects. The quality of eligible guidelines was assessed using the Appraisal of Guidelines for Research and Evaluation (AGREE) II instrument. RESULTS: From 1196 records retrieved from comprehensive searches and two records manually included, 20 clinical practice guidelines were deemed eligible. Based on an appraisal using the AGREE II instrument, 16 (80%) guidelines had ≤2 domains with scores >66%. Overall, the lowest scoring domains were for applicability, editorial independence and stakeholder involvement. There was relatively poor agreement across the guidelines for what defines a 'glaucoma suspect' or 'primary open angle glaucoma [POAG] suspect', as well as the recommendations and criteria for treatment initiation in these populations. There was better agreement for the definition and recommendations for treatment initiation for 'primary angle closure suspects'. CONCLUSIONS: There is substantial room to improve the methodological quality of most current international clinical guidelines for glaucoma suspects. Clinicians should consider this finding when using such guidelines to inform their care of glaucoma suspects. Substantial variation in the definition of a POAG suspect and recommendations for treatment initiation underscores important gaps in the current evidence for the accurate prediction of glaucoma development and treatment effectiveness in these individuals.

4.
Medicina (Kaunas) ; 59(2)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36837582

RESUMO

Background and objectives: We aimed to evaluate the effects of the water drinking test (WDT) on several systemic and ocular parameters, including choroidal thickness, which was assessed through optical coherence tomography angiography (OCTA), in glaucoma suspects. Materials and Methods: A total of 40 eyes from 20 glaucoma suspects without any systemic or ocular diseases were included in this prospective observational study. All the participants undertook the WDT, which required the drinking of 1 L of table water in 5 min. The outcome measures included IOP, systolic and diastolic blood pressure (SBP and DBP), mean arterial pressure (MAP), mean ocular perfusion pressure (MOPP), ocular pulse amplitude (OPA), and subfoveal and peripapillary choroidal thickness, which were assessed at baseline and at four 15 min intervals after the WDT. Generalized least squares models and mixed model analyses that take into account repeated measurements were used to assess the changes over time of these parameters. Results: All the ocular and systemic parameters showed statistically significant changes at all time points compared to baseline apart from choroidal thickness. The peak changes were an IOP of 20.1 mmHg versus 17.3 mmHg at 45 min, an SBP of 137.6 mmHg versus 125 mmHg at 30 min, a DBP of 95.9 mmHg versus 85.7 mmHg at 15 min, and an MOP of 53.51 mmHg versus 48.89 mmHg at 15 min. Conclusions: Despite elevations in IOP and significant changes in all the assessed systemic parameters, the WDT was not associated with changes in choroidal thickness in glaucoma suspects.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Humanos , Tonometria Ocular , Corioide , Água , Tomografia de Coerência Óptica
5.
BMC Ophthalmol ; 22(1): 414, 2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36316681

RESUMO

BACKGROUND: Optical coherence tomography (OCT) angiography (OCTA) provides a quantitative assessment of the microcirculation of the retina and choroid. It may precede the retinal nerve layer (RNFL) and optic disc head defects. Retinal nerve fiber layer defects and reduced central corneal thickness (CCT) are important parameters in the assessment of a glaucoma suspect patients. The aim of this study is to investigate any possible relationship between the reduced central corneal thickness and the radial peripapillary capillary (RPC) density defect in glaucoma suspect. METHODS: In this cross sectional study, 92 eyes were incorporated. Peripapillary OCT angiography (4.5 mm) and Anterior segment OCT for corneal pachymetry were done. C/D Ratio, thickness of nerve fiber layer, the blood flow indices and central corneal thickness also were evaluated. RESULTS: In eyes of glaucoma suspect patients; a significant positive correlation between CCT and total RPC density was detected (r = 0.38, P < 0.001). A strong positive correlation was also found between total RPC and peripapillary RNFL thickness (r = 0.55, P < 0.001). CONCLUSION: Reduced central corneal thickness and peripapillary capillary density are two screening parameters for glaucoma suspect patients. The radial peripapillary capillary density is a valid diagnostic tool for glaucoma.


Assuntos
Glaucoma , Hipertensão Ocular , Humanos , Angiofluoresceinografia/métodos , Fibras Nervosas , Células Ganglionares da Retina , Vasos Retinianos , Densidade Microvascular , Campos Visuais , Estudos Transversais , Pressão Intraocular , Tomografia de Coerência Óptica/métodos , Glaucoma/diagnóstico
6.
Ophthalmology ; 128(7): 993-1004, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33245936

RESUMO

PURPOSE: To investigate corneal stiffness parameters (SPs) as predictors of future progression risk in glaucoma suspect eyes. DESIGN: Prospective, longitudinal study. PARTICIPANTS: Three hundred seventy-one eyes from 228 primary open-angle glaucoma suspects, based on optic disc appearance, with normal baseline Humphrey Visual Field (HVF; Carl Zeiss Meditec) results. METHODS: Baseline corneal SPs were measured using Corvis ST (Oculus Optikgeräte GmbH). Participants were followed up every 6 months with clinical examination, HVF testing, and OCT. The baseline SP at first applanation (SP-A1) and highest concavity predicted the prospective outcome measures. MAIN OUTCOME MEASURES: Structural progression was measured by the OCT rate of thinning of the retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL). Functional progression was assessed by permutation analysis of pointwise linear regression criteria on HVF testing. RESULTS: Stiffness parameters correlated positively with central corneal thickness (CCT), which was adjusted for in all analyses. A higher SP-A1, suggestive of a stiffer cornea, was associated with a faster rate of RNFL thinning (P < 0.001), synergistic with thinner CCT (P = 0.004) over a mean follow-up of 4.2 years. Eyes with higher SP-A1 and thinner CCT (thin and stiff corneas) showed accelerated RNFL thinning by 0.72 µm/year relative to eyes with lower SP-A1 and thicker CCT (95% confidence interval [CI], 0.17-1.28; P = 0.011) and were at 2.9-fold higher likelihood of fast RNFL progression of more than 1 µm/year (95% CI, 1.4-6.1; P = 0.006). Consistent results also were observed with GCIPL thinning. Furthermore, a higher SP-A1 was associated with a greater risk of visual field progression (P = 0.002), synergistic with thinner CCT (P = 0.010). Eyes with higher SP-A1 and thinner CCT were at 3.7-fold greater risk of visual field progression relative to eyes with thicker CCT and lower SP-A1 (95% CI, 1.3-10.5; P = 0.014). CONCLUSIONS: Glaucoma suspect eyes with higher corneal SPs and lower CCT, suggestive of thin and stiff corneas, are at greater risk of progression. Corneal SPs seem to act synergistically with CCT as risk factors for glaucoma progression.


Assuntos
Córnea/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Tomografia de Coerência Óptica/métodos , Córnea/diagnóstico por imagem , Progressão da Doença , Elasticidade , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Campos Visuais/fisiologia
7.
Graefes Arch Clin Exp Ophthalmol ; 254(8): 1599-1608, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27255459

RESUMO

PURPOSE: To investigate retinal vessel diameter in patients classified as bilateral glaucoma suspects who showed unilateral glaucomatous conversion. METHODS: This retrospective study included 21 patients who had initially been diagnosed as bilateral glaucoma suspects but showed unilateral glaucomatous conversion during a follow-up period of more than 2 years. Conversion to glaucoma was determined either by documentation of a new retinal nerve fiber layer defect on red-free photography or a reproducible glaucomatous visual field defect. The central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) were measured from fundus photographs taken at baseline and at the point of glaucoma conversion. RESULTS: The mean CRAE of the converted eyes was significantly lower than that of the non-converted eyes at baseline (164.9 ± 13.2 µm vs 175.2 ± 15.6 µm; p = 0.001), but no significant difference was observed in the mean CRVE (p = 0.108). The mean CRAE of the converted eyes was also lower than in the non-converted eyes at the point of glaucoma conversion (158.6 ± 13.5 µm vs 168.0 ± 17.2 µm; p = 0.011). CONCLUSION: In bilateral glaucoma suspects, there was a significant inter-eye difference in CRAE at baseline between eyes that converted to glaucoma and those that did not. These findings suggest that measurement of retinal arteriolar diameter may help clinicians when evaluating the risk of conversion in glaucoma suspects.


Assuntos
Glaucoma/diagnóstico , Gonioscopia/métodos , Pressão Intraocular , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Progressão da Doença , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
8.
BMC Ophthalmol ; 16: 62, 2016 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-27225333

RESUMO

BACKGROUND: To investigate the incidence and risk factors of glaucoma in normal-tension glaucoma (NTG) suspect patients who had been lost-to-follow-up for at least 24 months. METHODS: Seventy-two eyes of 72 NTG suspect patients who returned to the hospital after at least 24 months of follow-up loss were enrolled in this study between January 2009 and June 2013. The data were collected retrospectively. The incidence of glaucoma was investigated using a comprehensive glaucoma evaluation in lost-to-follow-up NTG suspect patients. The patients were classified into the glaucoma group, who developed glaucoma during the study period, and the glaucoma suspect group, who did not, to analyse the risk factors for glaucoma. RESULTS: The number of patients who developed glaucoma was 7 (9.7 %) out of the 72 NTG suspect patients who had been mean lost-to-follow-up for 44 months. The rate of progression from suspected to glaucoma was 2.6 %/year. In the glaucoma group, the baseline intraocular pressure (IOP) was 18.43 ± 2.44 mmHg, and the average retinal nerve fiber layer (RNFL) thickness was 78.14 ± 7.60 µm; in the glaucoma suspect group, the baseline IOP was 14.95 ± 2.47 mmHg, and the average RNFL thickness was 92.55 ± 7.65 µm. The study results showed that the glaucoma group had higher baseline IOP and a thinner average RNFL (p = 0.003; p < 0.001). The results of the multivariable logistic regression analysis showed that the risk factors for glaucoma were high baseline IOP (OR = 1.63; p = 0.037) and a thin average RNFL (OR = 0.841; p = 0.004). CONCLUSIONS: The incidence of glaucoma in the lost-to-follow-up NTG suspect patients was 9.7 % for approximately 44 months, at a rate of 2.6 %/year. The risk factors for glaucoma in these patients were high baseline IOP and a thin average RNFL.


Assuntos
Glaucoma/epidemiologia , Glaucoma de Baixa Tensão/epidemiologia , Adulto , Idoso , Feminino , Seguimentos , Glaucoma/etiologia , Glaucoma/patologia , Glaucoma/fisiopatologia , Humanos , Incidência , Pressão Intraocular/fisiologia , Modelos Logísticos , Perda de Seguimento , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Retina/patologia , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
9.
Ophthalmic Epidemiol ; 31(2): 145-151, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37198948

RESUMO

PURPOSE: The utility of screening for early diagnosis of glaucoma remains a widely debated topic in the care of ophthalmic patients. There are currently no population-based guidelines regarding screening for glaucoma. The purpose of this study is to determine the utility of optical coherence tomography (OCT) for early glaucoma screening in a population of diabetic patients. The results of this study may inform future screening practices. METHODS: The current study is a post hoc analysis of OCT data collected from diabetic patients screened for eye disease over 6 months. Glaucoma suspects (GS) were identified based on abnormal retinal nerve fiber layer (RNFL) thickness on OCT. Fundus photographs of GS were graded by two independent raters for vertical cup-to-disc ratio (CDR) and other signs of glaucomatous changes. RESULTS: Of the 807 subjects screened, 50 patients (6.2%) were identified as GS. The mean RNFL thickness for GS was significantly lower than the mean RNFL in the total screening population (p < .001). Median CDR for GS was 0.44. Twenty-eight eyes of 17 GS were marked as having optic disc notching or rim thinning by at least one grader. Cohen's kappa statistic for inter-rater reliability was 0.85. Racial differences showed that mean CDR was significantly higher in non-whites (p < .001). Older age was associated with thinner RNFL (r = -0.29, p = .004). CONCLUSIONS: Results of this study suggest that in a sample of diabetic patients, a small but clinically significant minority may be flagged as GS based on OCT. Nearly one-third of GS eyes were found to have glaucomatous changes on fundus photography by at least one grader. These results suggest screening with OCT may be useful in detecting early glaucomatous changes in high-risk populations, particularly older, non-white patients with diabetes.


Assuntos
Diabetes Mellitus , Glaucoma , Hipertensão Ocular , Humanos , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Pressão Intraocular , Células Ganglionares da Retina , Glaucoma/diagnóstico , Hipertensão Ocular/diagnóstico
10.
Cureus ; 16(6): e63052, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39050330

RESUMO

This clinical report discusses the interplay of various pathologies that may present similar clinical manifestations, with uncertainty about the distinct impact of each one of them. The patient is a 43-year-old young Asian female with no known medical conditions. She was 33 weeks pregnant when she was admitted for an urgent c-section because of preeclampsia with HELLP syndrome. While hospitalized, she complained about the visual field's loss. A comprehensive ophthalmological examination revealed a severe concentric visual field defect along with well-reduced visual acuity and impaired color vision. Her OCT revealed a bilateral serous macular detachment related to pre-eclampsia. A brain MRI revealed a microstroke at the temporo-parieto-occipital junction (TPO), although it did not fully account for the severity of the visual field deficit. Despite the macular pathology being resolved, the visual field remained deeply impacted. A thorough and complete investigation yielded negative results, leaving the cause of the patient's deficit unknown. The patient likely had a normal pressure glaucoma. Additionally, multifactorial bilateral microvascular ischemic neuropathy (caused especially by high myopia) has significantly affected her visual field. Furthermore, it is also probable that the patient had genetic neuropathy. Initial genetic testing was negative; however, due to the high suspicion of a genetic component, a retest was conducted, and the results were not conclusive. This case represents a highly unusual case of a profoundly affected visual field with no apparent identified cause. This is a notable example of the potential interaction of various local and systemic pathologies that can manifest with similar clinical presentations.

11.
Ophthalmol Glaucoma ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38959998

RESUMO

PURPOSE: To examine social factors associated with the 5-year risk of glaucoma suspects (GS) converting to open-angle glaucoma (OAG). DESIGN: Retrospective cohort analysis. SUBJECTS: We screened for participants diagnosed with GS in the All of Us database. Cases that converted to OAG within 5 years of GS diagnosis (the "conversion group") were compared with control cases that did not convert. METHODS: Demographic, socioeconomic and health-care utilization data of the cases were extracted and compared between the conversion group and the control group. Multivariable Cox proportional hazards modeling was used to identify potential factors associated with the risk of conversion. MAIN OUTCOME MEASURES: Hazard ratios (HRs) of significant factors associated with the risk of conversion. RESULTS: A total of 5274 GS participants were identified, and 786 (15%) cases converted to OAG within 5-year follow-up. The 2 groups showed significant differences in age, race, gender, employment status, income/education level, history of intraocular surgery, and health-care utilization patterns. In the multivariable model, African American/Black race (HR : 1.70 [95% confidence interval (CI) 1.44-2.00]), older age at GS diagnosis (1.17 [95% CI 1.09-1.25]), male gender (1.30 [95% CI 1.13-1.50], no history of recreational drug use (1.23 [1.07-1.42]), history of intraocular surgery (1.60 [95% CI 1.02-1.53]), and having more reasons for delayed health-care access (2.27 [95% CI 1.23-4.18]) were associated with a greater hazard of conversion, while being employed (0.71 [95% CI 0.60-0.86]) was associated with a smaller hazard of conversion (P < 0.05 for all). CONCLUSIONS: Several social factors were associated with the conversion from GS to OAG, which may help to identify patients at higher risk of disease progression. Future studies are needed to examine the basis for these findings and the potential interventions that could address them. FINANCIAL DISCLOSURES: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

12.
J Clin Med ; 13(1)2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38202211

RESUMO

We aimed to characterize and compare the occurrence of peripapillary microvasculature dropout (MvD) between glaucoma suspects and patients with glaucoma. In addition, the factors related to the development of parapapillary MvD in glaucoma suspects and patients with glaucoma were investigated. Of a total 150 eyes, 68 eyes of glaucoma suspects and 82 eyes of glaucoma patients were analyzed in this study. Univariate and multivariate logistic regression analyses were used to identify factors associated with MvD development. The classification of glaucoma patients or glaucoma suspects was not significantly associated with MvD development (beta 1.368, 95% CI, 0.718-2.608, p = 0.341). In the regression analysis of the glaucoma suspect group, greater axial length (beta 1.520, 95% CI, 1.008-2.291, p = 0.046) and baseline cup volume (beta 3.993, 95% CI, 1.292-12.345, p = 0.035) among the baseline factors and the slope of ganglion cell-inner plexiform layer (GCIPL) thickness (beta 0.027, 95% CI, 0.072-0.851, p = 0.027) and central visual field (VF) progression (beta 7.040, 95% CI, 1.781-16.306, p = 0.014) among follow-up factors were significantly associated with MvD development. In the glaucoma group, central VF progression (beta 5.985, 95% CI, 1.474-24.083, p = 0.012) and ONH depression (beta 3.765, 95% CI, 1.301-10.895, p = 0.014) among follow-up elements were observed as significant factors and the baseline factor had little relationship. MvD appears not only as a result of the progression of axonal loss of RGC in glaucoma but may also be developed due to structural changes and mechanical susceptibility of the ONH associated with baseline characteristics. Analyzing the structural susceptibility of the ONH can predict the occurrence of MvD, which can be helpful in predicting the progression of glaucoma.

13.
Ophthalmol Sci ; 3(4): 100322, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37334035

RESUMO

Topic: To provide standardized confidence limits of the transient pattern electroretinogram (tPERG) P50 and N95 and steady state pattern electroretinogram (ssPERG) amplitudes in normal controls as compared to ocular hypertension (OHT), glaucoma suspect (GS), or early manifest glaucoma (EMG) eyes. Clinical Relevance: The identification of standardized confidence limits in the context of pattern electroretinogram (PERG) might overcome the high intrinsic variability of the measure, and it might lead to a more intuitive understanding of the results as well as to an easier comparison of data from multiple tests, sites, and operators. Methods: The study protocol was prospectively registered on the International Prospective Register of Systematic Reviews (ID: CRD42022370032). A literature search was conducted on PubMed, Web of Science, and Scopus. Studies comparing PERG raw data in normal control eyes as compared to OHT, GS, or EMG were included. The risk of bias was assessed using the National Institute for Health and Clinical Excellence quality assessment tool. The main outcome was the P50, N95, and ssPERG amplitude difference between the control and the study groups' eyes. The standardized mean difference was calculated as a measure of the effect size for the primary outcome. A subanalysis was conducted based on the type of electrodes adopted for the PERG measurements (invasive vs. noninvasive). Results: Of the 4580 eligible papers, only 23 were included (1754 eyes). Statistically significant amplitude differences were found in the P50, N95, and ssPERG amplitudes between normal controls and OHT, GS, and EMG eyes. The highest standardized mean difference values were observed in the ssPERG amplitude in all 3 sets of comparison. The subanalysis did not reveal any statistically significant differences between invasive and noninvasive recording strategies. Conclusions: The use of standardized values as the main outcome measures in the context of the PERG data analysis is a valid approach, normalizing several confounding factors which have affected the clinical utility of PERG both for individual patients and in clinical trials. Steady state PERG apparently better discriminates diseased eyes compared to tPERG. The adoption of skin-active electrodes is able to adequately discriminate between healthy and diseased statuses. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

14.
J Clin Med ; 12(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37568492

RESUMO

To explore various parameters that can evaluate the central visual impairment in patients with early-stage glaucoma, we included patients into a study with central visual impairments with an MD value greater than -6.0 dB on the 24-2 VF test. A possible association between structural parameters acquired by OCT and functional parameters of VF and PERG was determined. A total of 70 eyes of patients with suspected glaucoma or NTG underwent VF, OCT, and PERG examinations. The patients were classified into two groups according to the MD of the 24-2 VF test. We used Pearson correlation analysis to evaluate the relationships between GCIPL thickness/RNFL thickness and visual functional parameters, such as PERG and perimetry. Linear regression analyses were conducted to evaluate the significant factors affecting the PSD of VF 10-2. In the low MD group, the P50 amplitude presented significant correlations (r = 0.346, p = 0.048) with GCIPL thickness. In the correlation analysis of the high MD group, it was found that only the PSD of 10-2 uniquely presented borderline significant correlations with GCIPL thickness (r = -0.327, p = 0.055), and no other functional parameter showed significant correlation. Univariate and multivariate analyses revealed that GCIPL thickness was significantly associated with a PSD of 10-2 VF (p < 0.001 and 0.013, respectively). Among various parameters, the P50 amplitude and 10-2 PSD demonstrated statistically borderline significant structure-function relationships with GCIPL thickness in early-stage glaucoma.

15.
Clin Ophthalmol ; 17: 3011-3021, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37850048

RESUMO

Purpose: To assess the ability of vascular perfusion parameters determined by optical coherence tomography angiography (OCTA) to detect and monitor glaucoma. Methods: This prospective study included healthy, glaucoma suspect and glaucomatous eyes. All eyes underwent comprehensive glaucoma examination, including visual field tests and ocular imaging scans by OCTA. Parameters measured included retinal nerve fiber layer (RNFL) thickness, ganglion cell analysis (GCA), vascular perfusion density (VPD) and flux index (FI) of the optic nerve and peri-papillary area. Ocular parameters in healthy, glaucoma suspect, and glaucomatous eyes were compared by generalized estimating equations (GEE) with adjustments for age, with their relationships analyzed by Pearson's correlation coefficient. Rates of change per year were compared in glaucomatous eyes with and without glaucoma progression. Results: This study enrolled 238 eyes, including 56 healthy, 79 glaucoma suspect, and 103 glaucomatous eyes. After adjustments for age, the average VPD (45.40 ± 0.19% vs 45.05 ± 0.22% vs 42.89 ± 0.32%, p < 0.001) and FI (0.4210 ± 0.0055 vs 0.4105 ± 0.0039 vs 0.3801 ± 0.0048, p < 0.001) in these three groups differed significantly. Average VPD in the glaucoma group was inversely associated with the severity of glaucoma, being 43.99 ± 0.32%, 42.63 ± 0.43% and 39.27 ± 0.48% in eyes with early, moderate and severe glaucoma, respectively (p < 0.001). Average VPD, as well as VPD in the superior and inferior quadrants correlated well with both OCT determined RNFL and visual field parameters. The decreases per year in both superior (-0.012 vs -0.001, p = 0.002) and inferior (-0.008 vs -0.003, p = 0.007) FI were significantly greater in glaucomatous eyes with than without glaucoma progression. Conclusion: Both VPD and FI as measured by OCTA are promising ocular parameters that can distinguish between normal and glaucomatous eyes. VPD is sensitive in comparing eyes at different glaucoma stages, whereas FI can detect rates of glaucoma progression. Trial Registration: Thai Clinical Trial Registry, TCTR20181031002.

16.
J Curr Glaucoma Pract ; 17(3): 157-165, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37920372

RESUMO

Aims and background: Practice guidelines assert that high-risk glaucoma suspects should be treated. Yet, there is ambiguity regarding what constitutes a high enough risk for treatment. The purpose of this study was to determine which factors contribute to the decision to treat glaucoma suspects and ocular hypertensive patients in an academic ophthalmology practice. Materials and methods: Retrospective cohort study of glaucoma suspects or ocular hypertensives at an academic ophthalmology practice from 2014 to 2020. Demographics, comorbidities, intraocular pressure (IOP), optical coherence tomography (OCT) findings, and visual field measurements were compared between treated and untreated patients. A multivariable logistic regression model assessed predictors of glaucoma suspected treatment. Results: Of the 388 patients included, 311 (80%) were untreated, and 77 (20%) were treated. There was no statistical difference in age, race/ethnicity, family history of glaucoma, central corneal thickness (CCT), or any visual field parameters between the two groups. Treated glaucoma suspects had higher IOP, thinner retinal nerve fiber layers (RNFL), more RNFL asymmetry, thinner ganglion cell-inner plexiform layers (GCIPL), and a higher prevalence of optic disc drusen, disc hemorrhage, ocular trauma, and proliferative diabetic retinopathy (PDR) (p < 0.05 for all). In the multivariable model, elevated IOP {odds ratio [OR] 1.16 [95% confidence interval (CI) 1.04-1.30], p = 0.008}, yellow temporal [5.76 (1.80-18.40), p = 0.003] and superior [3.18 (1.01-10.0), p = 0.05] RNFL quadrants, and a history of optic disc drusen [8.77 (1.96-39.34), p = 0.005] were significant predictors of glaucoma suspect treatment. Conclusion: Higher IOP, RNFL thinning, and optic disc drusen were the strongest factors in the decision to treat a glaucoma suspect or ocular hypertensive patient. RNFL asymmetry, GCIPL thinning, and ocular comorbidities may also factor into treatment decisions. Clinical significance: Understanding the clinical characteristics that prompt glaucoma suspect treatment helps further define glaucoma suspect disease status and inform when treatment should be initiated. How to cite this article: Ciociola EC, Anderson A, Jiang H, et al. Decision Factors for Glaucoma Suspects and Ocular Hypertensive Treatment at an Academic Center. J Curr Glaucoma Pract 2023;17(3):157-165.

17.
Photodiagnosis Photodyn Ther ; 43: 103746, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37595654

RESUMO

PURPOSE: To determine the diagnostic value of optic nerve head (ONH) topographic parameters measured by swept-source optical coherence tomography (SS-OCT) in differentiating between early glaucoma cases, glaucoma suspects (GSs), and healthy eyes. METHODS: The files of GSs, those with an early primary open angle glaucoma (POAG) diagnosis, and healthy eyes were retrospectively screened. Demographic characteristics, retinal nerve fibre measurements, visual field examinations, and ONH topographic parameters, including rim area, disc area, vertical and horizontal cup-to-disc ratios (CDRs), and cup volume, were compared between the groups. A receiver operating characteristic (ROC) curve analysis was performed on the ONH parameters. RESULTS: A total of 170 eyes from 85 GSs, 114 eyes from 57 patients with a diagnosis of early POAG, and 70 healthy eyes from 48 subjects were included in the study. The median age was 52.1 ± 0.9 years for the POAG group, 60.2 ± 1.1 years for the GS group, and 60.5 ± 1.6 for the controls. In the comparison of the ONH parameters between the groups, only rim area statistically significantly differed between the POAG and GS groups. However, all ONH parameters statistically significantly differed between the GS and control groups (p< 0.05). The mean rim areas of the GS, POAG, and control groups were 1.278 ± 0.055 mm2, 1.073 ± 0.065 mm2, and 1.446 ± 0.055 mm2, respectively, being statistically significantly higher in the controls and lower in the POAG group (p < 0.001). The highest area under the curve (AUC) value belonged to vertical CDR for the discrimination of the eyes with POAG from healthy eyes [0.806 (0.728-0.869, p < 0.001] and rim area for the discrimination of POAG cases and GSs [0.728 (0.650-0.797, p < 0.001]. CONCLUSION: There are significant differences in all ONH parameters between the eyes of GSs and healthy eyes. For the discrimination of early POAG and GS cases, topographic disc parameters may have value. In this study, rim area significantly differed between the GS and POAG groups, and it had the highest AUC value amongst the evaluated ONH parameters in the discrimination of early POAG cases S GSs.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Fotoquimioterapia , Humanos , Pessoa de Meia-Idade , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Retrospectivos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Disco Óptico/diagnóstico por imagem
18.
Cureus ; 14(8): e28121, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35990564

RESUMO

Ophthalmologic care is inaccessible to many people due to a variety of factors, including the availability of providers, cost of equipment for ophthalmologic care, and transportation to clinics and appointments. Because many causes of blindness are both highly prevalent and preventable once identified, it is essential to address gaps in care for underserved populations. We developed a novel 3D-printed mobile retinal camera. In this study, we organized recurring student-run screening events around New York City that took place in community centers and churches, at which we utilized our device to take retinal images. Our screening events reached a diverse population of New Yorkers, disproportionately those with lower household income, many of whom had not had recent eye exams. To validate the device for use in telehealth ophthalmologic visits, we transmitted the images to a remote ophthalmologist for evaluation and compared the result with an on-site attending physician's dilated eye exam. The subjective assessment indicated that 97% of images captured with the mobile retinal camera were acceptable for telehealth analysis. Remote image assessment by achieved 92% sensitivity and 83% specificity in detecting optic disc cupping, compared to the gold-standard on-site dilated eye exam. In addition, the device was portable, affordable, and able to be used by those with relatively little ophthalmologic training. We have demonstrated the utility of this affordable mobile retinal camera for telehealth ophthalmologic evaluation during community screening events that reached an underserved population to detect disease and connect with long-term care.

19.
J Curr Glaucoma Pract ; 16(1): 11-16, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36060045

RESUMO

Purpose: Using demographic, clinical, visual field, and optical coherence tomography (OCT) variables to study the association of 5-year glaucomatous progression in glaucoma suspect eyes. Patients and methods: This is a retrospective longitudinal clinical study. Inclusion criteria consisted of glaucoma suspect eyes (i.e., concerning cup-to-disk ratio and/or intraocular pressure (IOP) >21 mm Hg), age ≥ 30 years old, follow-up time of 5 years, best-corrected visual acuity (BCVA) of 20/100 or better, spherical equivalent (SE) higher than 8 diopters and an astigmatism less than 3 diopters. Eyes with glaucoma-determined by two consecutive, reliable visual field tests-were excluded, as well as any eyes with any clinically significant retinal or neurological disease. The percentage of glaucoma suspect eyes, which progressed to glaucoma within a 5-year period, was calculated. Study subjects were divided into the following groups: eyes that progressed to glaucoma and those that did not. Results: In the 288 patients which we looked at, 365 total eyes, 323 eyes had concerning cup-to-disk ratio and 42 had ocular hypertension. Bivariate analysis showed that the eyes which progressed to glaucoma had significantly worse mean deviation, increased pattern standard deviation (PSD), and less visual field index (VFI). Our bivariate analysis also showed a thinner average, superior and inferior retinal nerve fiber layer thickness (RNFL), and more severe average, superior, and inferior RNFL damages (i.e., color grading scale) at baseline. Logistic regression analysis showed that only PSD and severe inferior RNFL damage (i.e., red color) to be significantly associated with 5-year glaucomatous progression. Conclusion: Segmental RNFL damage and pattern standard deviation are associated with 5-year glaucomatous progression in glaucoma suspect eyes. How to cite this article: Nassiri N, Das S, Patel V, et al. Factors Associated with 5-year Glaucomatous Progression in Glaucoma Suspect Eyes: A Retrospective Longitudinal Study. J Curr Glaucoma Pract 2022;16(1):11-16.

20.
J Curr Glaucoma Pract ; 16(2): 96-104, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128077

RESUMO

Aim: To investigate whether steady state pattern electroretinogram (ssPERG) could identify retinal ganglion cell (RGC) dysfunction, and to assess the relationship between ssPERG with optical coherence tomography (OCT) measurements in glaucoma suspects (GS). Materials and methods: This was a prospective cohort study of GS, identified based on suspicious optic disk appearance and glaucoma risk factors. Complete eye exam, Standard automated perimetry, OCT, and ssPERG were performed. Magnitude (Mag), Magnitude D (MagD), and MagD/Mag ratio were subsequently used in the correlation and linear regression analyses between ssPERG parameters and the RNFL, GCL/IPL, and macular thicknesses measurements. Results: Forty-nine eyes of 26 patients were included. Mag and MagD were significantly correlated with the superior, inferior, and average RNFL thicknesses (avRNFLT). All ssPERG parameters were significantly correlated with the average and minimum GCL/IPL thicknesses and the inner macular sector thicknesses. Mag and MagD significantly predicted the superior, inferior, and avRNFLT in the regression analysis. All ssPERG parameters were predictive of GCL/IPL thickness in all sectors as well as the average and minimum GCL/IPL thicknesses. All ssPERG parameters were predictive of all inner macular sector thicknesses and MagD was also predictive of some outer macular sector thicknesses as well. Conclusion: ssPERG has significant correlations with and is predictive of RNFL, GCL/IPL, and macular thicknesses in glaucoma suspects. Clinical significance: ssPERG may serve as a useful objective functional tool for identifying and following the progression of disease in glaucoma suspects. How to cite this article: Tirsi A, Wong A, Zhu D, et al. Pattern Electroretinogram Parameters and their Associations with Optical Coherence Tomography in Glaucoma Suspects. J Curr Glaucoma Pract 2022;16(2):96-104.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA