Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
World J Urol ; 42(1): 517, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39259253

RESUMO

PURPOSE: Robot-assisted laparoscopic radical prostatectomy (RARP) is the most common robotic procedures performed in urologic oncology. The Hugo Robot-Assisted Surgery (RAS) System (Medtronic, USA©) has recently been launched on the market and is characterized by the modularity of four different independent arm carts. The aim of this study is to describe and evaluate safety and feasibility of three-arms setting for RARP using the Hugo RAS™ System in a large case series. METHODS: Between October 2022 and December 2023, a large case series of patients from two tertiary referral center who underwent RARP through HUGO™ RAS were prospectively enrolled. Informed written consent was obtained before the procedure and a three-arms setting was used in every case. Follow-up was scheduled according to EAU guidelines. RESULTS: A total of 86 patients were included in this study and underwent RARP with Hugo™ RAS System. Median Console time time was 114 min (IQR, 75-150), median docking time 4 min (IQR, 3-5). Lymphadenectomy was successfully performed when indicated in 19 patients (22.1%). A vesicourethral anastomosis using the modified Van Velthoven technique was successfully achieved in all cases. No post-operative complications > Clavien II up to 30 post-operative days were reported. In all patients, catheter was removed on the 7th postoperative day. CONCLUSION: We conducted the first large case series of RARP through the novel Hugo™ RAS System using a three-arms configuration. This innovative robotic platform showed an easily accessible docking system, providing excellent perioperative outcomes.


Assuntos
Estudos de Viabilidade , Prostatectomia , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Prostatectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Pessoa de Meia-Idade , Idoso , Neoplasias da Próstata/cirurgia , Estudos Prospectivos , Desenho de Equipamento , Laparoscopia/métodos
2.
World J Urol ; 42(1): 336, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762627

RESUMO

PURPOSE: To evaluate Hugo RAS against the Da Vinci system for Robot-Assisted Radical Prostatectomy (RARP) in prostate cancer treatment. METHODS: We compared outcomes of 150 patients with prostate cancer undergoing RARP with either Hugo or Da Vinci systems. Our analysis included operative, postoperative, pathological, and functional outcomes. RESULTS: Both groups had 75 patients. Baseline characteristics and tumor features were similar. Intraoperatively, Da Vinci had a shorter docking time (10.45 vs. 18.62 min, p = 0.02), but total operative times were comparable (145.34 vs 138.95, p = 0.85). Hugo outperformed in neck dissection and lymphadenectomy times (22 vs 13.67 min, p = 0.027 and 37.82 vs 45.77 min, p = 0.025). Postoperative metrics like stay duration, catheter time, and complications showed no significant difference. Functional results, using IPSS and IIEF5, were similar between systems. Six Da Vinci patients (8%) and nine Hugo patients (12%) experienced social incontinence (p = 0.072). Pathological outcomes like T stage, Gleason Score, and nodes removed were alike. However, Hugo had more positive surgical margins (20% vs. 10.67%, p = 0.034). CONCLUSIONS: RARP outcomes using Hugo RAS were similar to the Da Vinci system in our study. More research and extended follow-up are required to ascertain long-term oncological and functional results.


Assuntos
Prostatectomia , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Humanos , Prostatectomia/métodos , Masculino , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Resultado do Tratamento
3.
Int J Colorectal Dis ; 39(1): 158, 2024 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-39384631

RESUMO

PURPOSE: The aim of the study was to compare the perioperative outcomes of patients affected by inflammatory bowel disease (IBD) who underwent surgery performed through laparoscopy or using the Medtronic Hugo™ RAS. METHODS: This is a retrospective study from a prospectively maintained database comparing laparoscopic vs. robotic-assisted surgery for IBD from 01/11/2017 to 15/04/2024. All procedures were performed by a single surgeon robotic-naïve with a large experience in laparoscopic surgery for IBD. The robotic procedures were performed using the Medtronic Hugo™ RAS platform. Outcomes were 30-day postoperative complications, operative time, conversion rate, intraoperative complications, length of hospital stay, and readmission rate. RESULTS: Among 121 consecutive patients, 80 underwent laparoscopic (LG) and 41 robotic-assisted surgery (RG). Baseline, preoperative and disease-specific characteristics were comparable except for older age (50 [38-56] vs. 38 [28-54] years; p = 0.05) and higher albumin level (42 [40-44] vs. 40 [38-42] g/L, p = 0.006) in the RG. The intracorporeal anastomosis was more frequent in the RG (80% vs. 6%; p < 0.001) with longer operative time (240 vs. 205 min; p = 0.006), while the conversion rate was not different (5% vs. 10%, p = 0.49). Surgical procedure types were equally distributed between the two groups, and the rate of intra-abdominal septic complication (IASC) was comparable across the different procedures. Postoperative complications were similar, including the rate of IASC (5% vs. 5%, p = 1), postoperative ileus (5% vs. 7.5%, p = 0.71), bleeding (2% vs. 5%, p = 0.66), and Clavien-Dindo > 2 complications (7% vs. 6%; p = 1). CONCLUSION: IBD surgery performed using the Medtronic Hugo™ RAS is safe and feasible, with similar postoperative outcomes when compared to the laparoscopic approach.


Assuntos
Doenças Inflamatórias Intestinais , Laparoscopia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Doenças Inflamatórias Intestinais/cirurgia , Adulto , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Laparoscopia/efeitos adversos , Duração da Cirurgia , Tempo de Internação , Readmissão do Paciente , Estudos Retrospectivos
4.
Int J Colorectal Dis ; 39(1): 154, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39349880

RESUMO

INTRODUCTION: In June 2023, our institution adopted the Medtronic Hugo RAS system for colorectal procedures. This system's independent robotic arms enable personalized docking configurations. This study presents our refined multi-docking strategy for robotic low anterior resection (LAR) and deep pelvic procedures, designed to maximize the Hugo RAS system's potential in rectal surgery, and evaluates the associated learning curve. METHODS: This retrospective analysis included 31 robotic LAR procedures performed with the Hugo RAS system using our novel multi-docking strategy. Docking times were the primary outcome. The Mann-Kendall test, Spearman's correlation, and cumulative sum (CUSUM) analysis were used to assess the learning curve and efficiency gains associated with the strategy. RESULTS: Docking times showed a significant negative trend (p < 0.01), indicating improved efficiency with experience. CUSUM analysis confirmed a distinct learning curve, with proficiency achieved around the 15th procedure. The median docking time was 6 min, comparable to other robotic platforms after proficiency. CONCLUSION: This study demonstrates the feasibility and effectiveness of a multi-docking strategy in robotic LAR using the Hugo RAS system. Our personalized approach, capitalizing on the system's unique features, resulted in efficient docking times and streamlined surgical workflow. This approach may be particularly beneficial for surgeons transitioning from laparoscopic to robotic surgery, facilitating a smoother adoption of the new technology. Further research is needed to validate the generalizability of these findings across different surgical settings and experience levels.


Assuntos
Procedimentos Cirúrgicos Robóticos , Centros de Atenção Terciária , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Pelve/cirurgia , Curva de Aprendizado , Idoso , Adulto , Estudos Retrospectivos
5.
Surg Endosc ; 38(3): 1180-1190, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38082007

RESUMO

BACKGROUND: Achalasia is a rare disorder of the esophagus characterized by motor dysfunction in the esophagus and relaxation failure of the lower esophageal sphincter (LES). Currently, surgical myotomy procedures are considered the standard of care. Robotic Heller's myotomy (RHM) with fundoplication has been gaining popularity due to documented advantages in the precision of myotomy as well as avoiding the potential reflux following per-oral endoscopic myotomy (POEM). To the best of our knowledge, RHM has thus far has been performed exclusively by the da Vinci surgical system. The new Hugo RAS™ system offers a unique modular design and an open console which offers better maneuverability and docking options. In this study, we present the first worldwide series of patients undergoing RHM using the new Hugo RAS™ platform. Our objective is to propose optimal operating configuration and setup to fully harness the advantages of the unique modular design of this system. METHODS: Ten consecutive achalasia patients underwent Robotic Heller's myotomy (RHM) with the Hugo RAS™ system. We prospectively collected patient data, including demographics, comorbidities, ASA class, Eckardt scores, pre-operative manometric data, and EndoFlip parameters. Additionally, we recorded the docking and total operative times. RESULTS: Between December 2022 and August 2023, 10 patients underwent RHM with the Hugo™ RAS system. Patients had a median age of 42.5 years, 60% were female, and mean BMI was 23.2. Fifty percent had achalasia type 2 and 50% type 1. The median pre-operative integrated relaxation pressure (IRP) was 24.9. Median docking time was 10 min and overall operative time was 129.5 min. All patients, except one with acute coronary syndrome, had an uneventful peri-operative course and were discharged on post-operative day 2. CONCLUSION: The Hugo™ RAS system is well designed for robotic Heller myotomy. The operative and clinical results are similar to the currently used robotic system; however, the modular design of the system has some differences. These translate to better docking angles and maneuverability as well as console surgeon's ergonomics. Further experience is needed to explore the advantages of the system's modular design and function.


Assuntos
Acalasia Esofágica , Miotomia de Heller , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Adulto , Masculino , Acalasia Esofágica/cirurgia , Resultado do Tratamento , Laparoscopia/métodos , Esfíncter Esofágico Inferior/cirurgia
6.
Surg Endosc ; 38(6): 3395-3404, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38719985

RESUMO

BACKGROUND: Transversus abdominis release (TAR) is an effective technique for treating large midline and off-midline hernias. Recent studies have demonstrated that robotic TAR (rTAR) is technically feasible and associated with improved outcomes compared to open surgery. There is no published experience to date describing abdominal wall reconstruction using the novel robotic platform HUGO RAS System (Medtronic®). METHODS: All consecutive patients who underwent a rTAR in our institution were included. Three of the four arm carts of the HUGO RAS System were used at any given time. Each arm configuration was defined by our team in conjunction with Medtronic® personnel. rTAR was performed as previously described. Upon completion of the TAR on one side, a redocking process with different, mirrored arms angles was performed to continue with the contralateral TAR. Operative variables and early morbidity were recorded. RESULTS: Ten patients were included in this study. The median BMI was 31 (21-40.6) kg/m2. The median height was 1.6 m (1.5-1.89 m). A trend of decreased operative time, console time, and redocking time was seen in these consecutive cases. No intraoperative events nor postoperative morbidity was reported. The median length of stay was 3 (1-6) days. CONCLUSION: Robotic TAR utilizing the HUGO RAS system is a feasible and safe procedure. The adoption of this procedure on this novel platform for the treatment of complex abdominal wall hernias has been successful for our team.


Assuntos
Músculos Abdominais , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Adulto , Idoso , Herniorrafia/métodos , Tempo de Internação/estatística & dados numéricos , Hérnia Ventral/cirurgia
7.
World J Urol ; 41(4): 1085-1091, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36847815

RESUMO

PURPOSE: Hugo™ RAS system is one of the most promising new robotic platforms introduced in the field of urology. To date, no data have been provided on robot-assisted partial nephrectomy (RAPN) performed with Hugo™ RAS system. The aim of the study is to describe the setting and report the performance of the first series of RAPN performed with Hugo™ RAS system. METHODS: Ten consecutive patients who underwent RAPN at our Institution between February and December 2022 were prospectively enrolled. All RAPN were performed transperitoneally with a modular four-arm configuration. The main outcome was to describe the operative room setting, trocar placement and the performance of this novel robotic platform. Pre, intra and post-operative, variables were recorded. A descriptive analysis was performed. RESULTS: Seven patients underwent RAPN for right-side and three for left-side masses. Median tumor size and PADUA score were 3 (2.2-3.7) cm and 9 (8-9), respectively. Median docking and console time were 9.5 (9-14) and 138 (124-162) minutes, respectively. Median warm ischemia time was 13 (10-14) minutes, and one case was performed clamp-less. Median estimated blood loss was 90 (75-100) mL. One major complication (Clavien-Dindo 3a) occurred. No case of positive surgical margin was recorded. CONCLUSION: This is the first series to prove the feasibility of Hugo™ RAS system in the setting of RAPN. These preliminary results may help new adopters of this surgical platform to identify critical steps of robotic surgery with this platform and explore solutions before in-vivo surgery.


Assuntos
Neoplasias Renais , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Nefrectomia/métodos , Resultado do Tratamento
8.
Sensors (Basel) ; 23(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37631641

RESUMO

The advent of robotic surgical systems had a significant impact on every surgical area, especially urology, gynecology, and general and cardiac surgery. The aim of this article is to delineate robotic surgery, particularly focusing on its historical background, its evolution, its present status, and its future perspectives. A comprehensive literature review was conducted upon PubMed/MEDLINE, using the keywords "robotic surgical system", "robotic surgical device", "robotics AND urology". Additionally, the retrieved articles' reference lists were investigated. Analysis concentrated on urological surgical systems for laparoscopic surgery that have been given regulatory approval for use on humans. From the late 1980s, before daVinci® Era in 2000s, ancestor platform as Probot® and PUMA 560 were described to outline historical perspective. Thus, new robotic competitors of Intuitive Surgical such as Senhance®, Revo-I®, Versius®, Avatera®, Hinotori®, and HugoTM RAS were illustrated. Although daVinci® had high level competitiveness, and for many years represented the most plausible option for robotic procedures, several modern platforms are emerging in the surgical market. Growing competition through unique features of the new robotic technologies might extend applications fields, improve diffusion, and increase cost-effectiveness procedures. More experiences are needed to identify the role of these new advancements in surgical branches and in healthcare systems.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Urologia , Humanos , Difusão , PubMed
9.
Sensors (Basel) ; 23(17)2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37687810

RESUMO

The use of robotic surgery (RS) in urology has grown exponentially in the last decade, but RS training has lagged behind. The launch of new robotic platforms has paved the way for the creation of innovative robotics training systems. The aim of our study is to test the new training system from Hugo™ RAS System-Medtronic. Between July 2020 and September 2022, a total of 44 residents from urology, gynaecology and general surgery at our institution participated in advanced robotic simulation training using the Hugo™ RAS simulator. Information about sex, age, year of residency, hours spent playing video games, laparoscopic or robotic exposure and interest in robotics (90.9% declared an interest in robotics) was collected. The training program involved three robotic exercises, and the residents performed these exercises under the guidance of a robotics tutor. The residents' performance was assessed based on five parameters: timing, range of motion, panoramic view, conflict of instruments and exercise completion. Their performance was evaluated according to an objective Hugo system form and a subjective assessment by the tutor. After completing the training, the residents completed a Likert scale questionnaire to gauge their overall satisfaction. The rate of the residents' improvement in almost all parameters of the three exercises between the first and the last attempts was statistically significant (p < 0.02), indicating significant progress in the residents' robotic surgical skills during the training. The mean overall satisfaction score ± standard deviation (SD) was 9.4 ± 1.2, signifying a high level of satisfaction among the residents with the training program. In conclusion, these findings suggest that the training program utilizing the Hugo™ RAS System is effective in enhancing robotic surgical skills among residents and holds promise for the development of standardized robotics training programs in various surgical specialties.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Terapia por Exercício , Simulação por Computador , Exercício Físico
13.
Updates Surg ; 76(1): 315-318, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38070071

RESUMO

This study describes the first reported treatment of a benign gynecological disease with the Medtronic's Hugo™ RAS System, the first robot-assisted device used in the field of gynecology in Japan. Patients who underwent robot-assisted total laparoscopic hysterectomy with the Hugo™ RAS System at the Tottori University Hospital between March 2023 and June 2023 were included in this study. In the first case, the patient was in her 40 s and had uterine fibroids. We describe our experience and compare the device with the conventional da Vinci surgical system. We discuss the key features of the Hugo system (including the independent arms, open console, and pistol-shaped handle), the convenience of robotic surgery, the potential to improve quality of life, and how this technology could revolutionize the field of surgery.


Assuntos
Laparoscopia , Leiomioma , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Qualidade de Vida , Histerectomia
14.
Asian J Endosc Surg ; 17(3): e13321, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38741376

RESUMO

In May 2023, the Hugo RAS system obtained pharmaceutical approval for use in gastroenterological surgery in Japan. It is expected to be particularly effective in rectal cancer surgery, which require the manipulation of the deep pelvic cavity and communication with surgeons operating from the intraperitoneal and anal approaches. A 68-year-old woman presented to our hospital with bloody stools and was diagnosed with cStage I (cT2N0M0) rectal cancer and underwent abdominoperineal resection employing the Hugo RAS system. Two arm carts were placed on the left and right lateral sides with an interleg space, and trocars were placed in a straight line between the right superior iliac spine and umbilicus. Herein, we report the first abdominoperineal resection for rectal cancer using the Hugo RAS system.


Assuntos
Protectomia , Neoplasias Retais , Humanos , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Feminino , Idoso , Protectomia/métodos , Adenocarcinoma/cirurgia , Adenocarcinoma/patologia
15.
J Clin Med ; 13(7)2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38610903

RESUMO

(1) Background: Laparoscopic partial nephrectomy (LPN) is still performed in many referred urological institutions, representing a valid alternative to robot-assisted partial nephrectomy (RAPN). We aimed to compare trifecta outcomes of LPN and RAPN with the Hugo™ RAS System. (2) Methods: Between October 2022 and September 2023, eighty-nine patients underwent minimally invasive partial nephrectomy (group A, RAPN = 27; group B, Laparoscopic PN = 62) for localized renal tumors at our Institution. Continuous variables were presented as median and IQR and compared by means of the Mann-Whitney U test, while categorical variables were presented as frequencies (%) and compared by means of the χ2 test. (3) Results: Group A showed a higher rate of male patients (81.5% vs. 59.7%, p = 0.04) and a higher trend towards larger clinical tumor size (34 vs. 29 mm, p = 0.14). All the other baseline variables were comparable between the two groups (all p > 0.05). Regarding post-operative data, group A displayed a lower operative time (92 vs. 149.5 min, p = 0.005) and a shorter hospital stay (3 vs. 5, p = 0.002). A higher rate of malignant pathology was evidenced in group A (77.8% vs. 58.1%, p = 0.07) as well as a lower trend towards positive surgical margins (3.7% vs. 4.8%, p = 0.82), even if not statistically significant. (4) Conclusions: The rate of trifecta achievement was 92.6% and 82.3% for group A and B (p = 0.10), respectively. In terms of trifecta outcomes, RAPN using the Hugo™ RAS System showed comparable results to LPN performed by the same experienced surgeon.

16.
ANZ J Surg ; 94(3): 387-390, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37984555

RESUMO

BACKGROUND: The Hugo RAS™ system (Medtronic, Minneapolis, MN, USA), approved for gynaecological and urological procedures, has been recently certified for the use in few general surgeries. Only bariatric and colorectal procedures have been described so far. METHODS: Here, we report the first worldwide experience with three cases of full-robotic cholecystectomies with the Hugo RAS™ system. RESULTS: A description of the operative room setup, of the docking angles and details of the procedures is reported. Docking time was 12, 10, and 6 min, respectively. The total operative time was 105 min in the first case, 100 min in the second and 88 in the third case. Intra- and post-operative courses were uneventful. CONCLUSIONS: With this pre-defined set up, the innovative conformation of Hugo RAS™ system can safely allow performing full robotic cholecystectomy avoiding the need for additional ports.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Colecistectomia/métodos , Robótica/métodos , Tempo , Duração da Cirurgia
17.
Updates Surg ; 76(5): 2043-2049, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38856924

RESUMO

The HUGO™ robotic-assisted surgery system (RAS, Medtronic, CA) consists of a 3D open console, four independent carts, and an integrated laparoscopic and robotic tower. Approved in 2021, it represents a novel alternative platform for robotic procedures. The aim of our study is to report the first-year experience with this system for gynecological procedures at two tertiary referral robotic centers. We prospectively collected and retrospectively analyzed data from patients underwent gynecological robot-assisted surgery with the HUGO™ RAS, at San Paolo University Hospital (Milan, Italy), and Onze Lieve Vrouw (OLV) Hospital (Aalst, Belgium), March 2022-April 2023. Demographic characteristics, intraoperative settings, and perioperative outcomes were investigated. A total of 32 procedures were performed: 20 (62.5%) hysterectomies, 7 (21.9%) adnexal surgeries, and 5 (15.6%) pelvic floor reconstructive surgeries. In 2022 and 2023, 13 (40.6%) and 19 (59.4%) procedures were carried out, respectively. The median docking time was 8 min (IQR 5.8-11.5). The median console and skin-to-skin time was 52.5 min (IQR 33.8-94.2) and 108.5 min (IQR 81.5-157.2), respectively. No intraoperative complications occurred. Two conversions to laparoscopy managed without any additional complications were needed. To the best of our knowledge, this is the first global series of gynecological procedures performed with the HUGO™ RAS. Our preliminary findings showed the system's feasibility reporting promising results. The observed upward trend in the total number of procedures during the analyzed period is encouraging. Further studies are needed to assess a standardized method in the gynecological field with the novel platform.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Procedimentos Cirúrgicos Robóticos , Centros de Atenção Terciária , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Procedimentos Cirúrgicos Robóticos/tendências , Feminino , Procedimentos Cirúrgicos em Ginecologia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Laparoscopia/métodos , Bélgica , Histerectomia/métodos , Idoso , Duração da Cirurgia , Itália
18.
J Robot Surg ; 18(1): 343, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39312046

RESUMO

Because of the increasing popularity of Hugo RAS as a surgical platform, a comparison examination of intraoperative and oncological outcomes across DaVinci and Hugo RAS robotic surgery platforms is urgently needed. We carried out a comprehensive review and meta-analysis of the literature of current research, comprehensively searching PubMed, Cochrane and Embase for eligible studies comparing the results between the DaVinci and Hugo RAS. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria were followed in the conduct of this study, with language restricted to English and a final search date of June 2024. We excluded articles composed solely of conference abstracts and irrelevant content. Composite outcomes were assessed using weighted mean differences (WMD) and odds ratios (ORs). The risk of bias in individual research was assessed using the Newcastle-Ottawa Scale (NOS), and heterogeneity and bias risk were controlled for using a sensitivity analysis. Six studies in all were considered, comprising 1025 patients, including 626 DaVinci patients and 399 Hugo RAS patients. Review Manager V5.4.1 software (Cochrane Collaboration, Oxford, UK) was utilized to conduct the meta-analysis, including 6 trials, which demonstrated that compared to Hugo RAS, DaVinci was associated with statistically significant differences in several outcomes: a reduction in operative time (OT) (WMD - 8.46, 95% CI - 13.56 to 3.36; p = 0.001), an increase in estimated blood loss (EBL) (WMD 41.68, 95% CI 23.59 to 59.77; p < 0.00001), and an increased pelvic lymphadenectomy ratio (OR 1.5, 95% CI 1.05-2.05; p = 0.01). On the contrary, there were no statistically noteworthy differences in the length of hospital stay (LOS) between the two teams (WMD - 0.05, 95% CI - 0.14 to 0.04; p = 0.25), nerve sparing (unilateral or bilateral) (OR 0.96, 95% CI 0.68-1.35; p = 0.8), postoperative complications (OR 1.15, 95% CI 0.50-2.64; p = 0.75), or positive surgical margins (PSM) (OR 1.08, 95% CI 0.76-1.54; p = 0.68). Although DaVinci offers shorter operating times (OT) and increased pelvic lymph node dissection rates, Hugo RAS demonstrates lower estimated blood loss (EBL). Overall, Hugo RAS Robot-Assisted Radical Prostatectomy (RARP) results seem to be similar to those obtained with the DaVinci system. Further research and long-term follow-up are necessary to ascertain durable oncological and functional outcomes, allowing doctors to switch between robotic systems and use their skills. These findings are crucial for patients, surgeons, and healthcare policymakers and warrant future studies with extended follow-up.


Assuntos
Duração da Cirurgia , Prostatectomia , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Excisão de Linfonodo/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Prostatectomia/efeitos adversos , Prostatectomia/instrumentação , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento
19.
Int J Gynaecol Obstet ; 166(1): 258-265, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38299809

RESUMO

OBJECTIVE: To evaluate the safety and feasibility of the new surgical robot HUGO robotic assisted surgery (RAS) in a series of gynecologic surgical procedures. METHODS: Between March and October 2022, 138 patients treated at Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy were enrolled in the study. All patients suitable for a minimally-invasive approach were prospectively included and divided into two groups: Group 1 (78 patients) made up of patients operated on for uterine and/or adnexal pathologies, and Group 2 (60 patients) made up of patients treated for pelvic organ prolapse. RESULTS: In Group 1, median docking time (DT) was 5 min and median console time (CT) was 90 min. In two patients (2.6%) redocking was necessary. In two patients (2.6%), the surgeon continued the surgery laparoscopically. Intraoperative complications occurred in two surgeries (2.6%). In Group 2, median DT was 4 min and median CT was 134.5 min. In three patients (5%), redocking was necessary. In all patients, the surgery was successfully completed robotically without intraoperative complications. CONCLUSIONS: The present study demonstrates that the new HUGO RAS system for gynecologic surgery is safe with good results in terms of surgical efficacy and perioperative outcomes. Further studies are needed to investigate its use in other technical and surgical aspects.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Pessoa de Meia-Idade , Procedimentos Cirúrgicos em Ginecologia/métodos , Procedimentos Cirúrgicos em Ginecologia/instrumentação , Adulto , Idoso , Estudos Prospectivos , Duração da Cirurgia , Laparoscopia/métodos , Laparoscopia/instrumentação , Estudos de Viabilidade , Prolapso de Órgão Pélvico/cirurgia , Itália , Complicações Intraoperatórias/epidemiologia , Idoso de 80 Anos ou mais
20.
ANZ J Surg ; 94(7-8): 1299-1304, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38553884

RESUMO

BACKGROUNDS: Rectal robotic surgery gained momentum in the last decade, but it is still associated with not-negligible costs. In order to reduce costs, recently different robotic systems have received approval for clinical use. This study aims to present the first case series of rectal resection with the novel cost-effective platform Robotic Assisted Surgery (RAS) Hugo™. Tips for effective set up of the system and detailed configuration of tilt and docking angles are also provided. METHODS: Three cases of rectal resection with Hugo RAS™ system are reported. After the first two cases of resection with partial mesorectal excision in which surgeries were performed with the setup proposed by the vendor company, in the third case we tested a novel setup that allowed a full robotic low rectal resection performing vascular ligations, TME and colonic splenic flexure mobilization without the need of any de-docking. RESULTS: Our first three robotic rectal resections with the Hugo RAS™ system were completed without complications with a median docking time of 12 min (range 8-15) and a median console time of 345 minutes (range 271-475). In the first two cases, hybrid robotic and laparoscopic surgeries were performed to obtain an adequate haemostasis and traction during the pelvic phase. In the third case, a full robotic TME was successfully accomplished. CONCLUSION: Our experience demonstrates that a full robotic low rectal resection with TME with Hugo™ RAS system is feasible, safe and associated with satisfactory postoperative outcomes.


Assuntos
Neoplasias Retais , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias Retais/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Laparoscopia/métodos , Reto/cirurgia , Protectomia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA