Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 519
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 24(1): 89-96, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-37939013

RESUMO

The ability to target specific tissues and to be internalized by cells is critical for successful nanoparticle-based targeted drug delivery. Here, we combined "stealthy" rod-shaped poly(2-oxazoline) (POx) nanoparticles of different lengths with a cancer marker targeting nanobody and a fluorescent cell internalization sensor via a heat-induced living crystallization-driven self-assembly (CDSA) strategy. A significant increase in association and uptake driven by nanobody-receptor interactions was observed alongside nanorod-length-dependent kinetics. Importantly, the incorporation of the internalization sensor allowed for quantitative differentiation between cell surface association and internalization of the targeted nanorods, revealing unprecedented length-dependent cellular interactions of CDSA nanorods. This study highlights the modularity and versatility of the heat-induced CDSA process and further demonstrates the potential of POx nanorods as a modular nanomedicine platform.


Assuntos
Nanopartículas , Nanotubos , Sistemas de Liberação de Medicamentos , Membrana Celular
2.
Small ; 20(27): e2310300, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38299477

RESUMO

Glutathione (GSH) is the primary antioxidant in cells, and GSH consumption will break the redox balance in cells. Based on this, a method that uses high concentrations of GSH in the tumor microenvironment to trigger the redox reaction of Cu(II) to generate copper nanoprobes with fluorescence and tumor growth inhibition properties is proposed. The nanoprobe mainly exists in the form of Cu(I) and catalyzes the decomposition of hydrogen peroxide into hydroxyl radicals. At the same time, a simple and controllable carbon micro-nano electrode is used to construct a single-cell sensing platform, which enable the detection of glutathione content in single living cells after Cu(II) treatment, providing an excellent example for detecting single-cell biomolecules.


Assuntos
Cobre , Glutationa , Glutationa/metabolismo , Cobre/química , Humanos , Neoplasias/metabolismo , Técnicas Biossensoriais/métodos , Linhagem Celular Tumoral , Animais , Oxirredução , Espaço Intracelular/metabolismo
3.
Chembiochem ; 25(14): e202400254, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38757240

RESUMO

In this work, a highly sensitive and selective method for detecting folic acid (FA) was developed using D-penicillamine (DPA) stabilized Ag/Cu alloy nanoclusters (DPA@Ag/Cu NCs). The yellow emission of DPA@Ag/Cu NCs was found to be quenched upon the addition of FA to the system. The fluorescence intensity quenching value demonstrated a linear relationship with FA concentrations ranging from 0.01 to 1200 µM, with a limit of detection (LOD) of 5.3 nM. Furthermore, the detection mechanism was investigated through various characterization analyses, including high resolution transmission electron microscopy, fluorescence spectra, ultraviolet-visible absorption spectra, and fluorescence lifetime. The results indicated that the fluorescence quenching induced by FA was a result of electron transfer from FA to the ligands of DPA@Ag/Cu NCs. The selectivity of the FA sensor was also evaluated, showing that common amino acids and inorganic ions had minimal impact on the detection of FA. Moreover, the standard addition method was successfully applied to detect FA in human serum, chewable tablets and FA tablets with promising results. The use of DPA@Ag/Cu NCs demonstrates significant potential for detecting FA in complex biological samples.


Assuntos
Ligas , Cobre , Corantes Fluorescentes , Ácido Fólico , Penicilamina , Prata , Espectrometria de Fluorescência , Penicilamina/análise , Penicilamina/química , Penicilamina/sangue , Cobre/química , Ácido Fólico/análise , Ácido Fólico/química , Ácido Fólico/sangue , Prata/química , Humanos , Ligas/química , Corantes Fluorescentes/química , Limite de Detecção , Nanopartículas Metálicas/química , Comprimidos/análise
4.
New Phytol ; 242(2): 453-465, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38413216

RESUMO

The water status of the living tissue in leaves is critical in determining plant function and global exchange of water and CO2. Despite significant advances in the past two decades, persistent questions remain about the tissue-specific origins of leaf hydraulic properties and their dependence on water status. We use a fluorescent nanoparticle reporter that provides water potential in the mesophyll apoplast adjacent to the epidermis of intact leaves to complement existing methods based on the Scholander Pressure Chamber (SPC). Working in tomato leaves, this approach provides access to the hydraulic conductance of the whole leaf, xylem, and outside-xylem tissues. These measurements show that, as stem water potential decreases, the water potential in the mesophyll apoplast can drop below that assessed with the SPC and can fall significantly below the turgor loss point of the leaf. We find that this drop in potential, dominated by the large loss (10-fold) of hydraulic conductance of the outside-xylem tissue, is not however strong enough to significantly limit transpiration. These observations highlight the need to reassess models of water transfer through the outside-xylem tissues, the potential importance of this tissue in regulating transpiration, and the power of new approaches for probing leaf hydraulics.


Assuntos
Solanum lycopersicum , Folhas de Planta/fisiologia , Água/fisiologia , Xilema/fisiologia , Transpiração Vegetal
5.
Artigo em Inglês | MEDLINE | ID: mdl-38961530

RESUMO

The incidence of thyroid tumors has been increasing yearly over the past decade, making it the fourth highest tumor in women. This places various biological burdens on those affected. Currently, thyroid tumors are primarily diagnosed using percutaneous fine needle aspiration and ultrasound. However, these methods are complex, expensive, and less accurate, and they may fail to detect some thyroid nodules. As an alternative, researchers are focusing on blood-based biomarkers in addition to the traditional diagnostic methods, assisted predominantly by nanomaterials. Early identification of thyroid cancer is crucial as it is highly treatable. Various sensing systems have been developed using nanomaterial-mediated approaches to enhance the detection system. Nanomaterials are effectively applied in biosensors for surface functionalization and are conjugated with biomolecules to improve the interaction with the target analyte. This review discusses nanomaterial-assisted thyroid tumor detection, with a special focus on nanomaterial-based biosensors.

6.
Proc Natl Acad Sci U S A ; 118(14)2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33795516

RESUMO

The ability to monitor the release of neurotransmitters during synaptic transmission would significantly impact the diagnosis and treatment of neurological diseases. Here, we present a DNA-based enzymatic nanosensor for quantitative detection of acetylcholine (ACh) in the peripheral nervous system of living mice. ACh nanosensors consist of DNA as a scaffold, acetylcholinesterase as a recognition component, pH-sensitive fluorophores as signal generators, and α-bungarotoxin as a targeting moiety. We demonstrate the utility of the nanosensors in the submandibular ganglia of living mice to sensitively detect ACh ranging from 0.228 to 358 µM. In addition, the sensor response upon electrical stimulation of the efferent nerve is dose dependent, reversible, and we observe a reduction of ∼76% in sensor signal upon pharmacological inhibition of ACh release. Equipped with an advanced imaging processing tool, we further spatially resolve ACh signal propagation on the tissue level. Our platform enables sensitive measurement and mapping of ACh transmission in the peripheral nervous system.


Assuntos
Acetilcolina/metabolismo , Técnicas Biossensoriais/métodos , Gânglios Parassimpáticos/metabolismo , Nanotecnologia/métodos , Acetilcolina/análise , Acetilcolinesterase/química , Acetilcolinesterase/metabolismo , Animais , Bungarotoxinas/farmacologia , Carbocianinas/química , Antagonistas Colinérgicos/farmacologia , DNA/química , Feminino , Corantes Fluorescentes/química , Gânglios Parassimpáticos/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Receptores Colinérgicos/metabolismo
7.
Mikrochim Acta ; 191(9): 525, 2024 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120793

RESUMO

A dual-emission ratiometric fluorescence sensor (CDs@CdTe@MIP) with a self-calibration function was successfully constructed for AMO detection. In the CDs@CdTe@MIP system, non-imprinted polymer-coated CDs and molecule-imprinted polymer-coated CdTe quantum dots were used as the reference signal and response elements, respectively. The added AMO quenched the fluorescence of the CdTe quantum dots, whereas the fluorescence intensity of the CDs remained almost unchanged. The AMO concentration was monitored using the fluorescence intensity ratio (log(I647/I465)0/(I647/I465)) to reduce interference from the testing environment. The sensor with a low detection limit of 0.15 µg/L enabled detection of the AMO concentration within 6 min. The ratiometric fluorescence sensor was used to detect AMO in spiked pork samples; it exhibited a high recovery efficiency and relative standard deviation (RSD) of 97.94-103.70% and 3.77-4.37%, respectively. The proposed highly sensitive and selective platform opens avenues for sensitive, reliable, and rapid determination of pharmaceuticals in the environment and food safety monitoring using ratiometric sensors.


Assuntos
Amoxicilina , Compostos de Cádmio , Limite de Detecção , Impressão Molecular , Pontos Quânticos , Espectrometria de Fluorescência , Telúrio , Pontos Quânticos/química , Compostos de Cádmio/química , Telúrio/química , Espectrometria de Fluorescência/métodos , Amoxicilina/análise , Amoxicilina/química , Corantes Fluorescentes/química , Sulfetos/química , Animais , Contaminação de Alimentos/análise , Polímeros Molecularmente Impressos/química , Suínos
8.
Mikrochim Acta ; 191(9): 551, 2024 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-39167235

RESUMO

Photon-upconversion nanoparticles (UCNP) have already been established as labels for affinity assays in analog and digital formats. Here, advanced, or smart, systems based on UCNPs coated with active shells, fluorescent dyes, and metal and semiconductor nanoparticles participating in energy transfer reactions are reviewed. In addition, switching elements can be embedded in such assemblies and provide temporal and spatial control of action, which is important for intracellular imaging and monitoring activities. Demonstration and critical comments on representative approaches demonstrating the progress in the use of such UCNPs in bioanalytical assays, imaging, and monitoring of target molecules in cells are reported, including particular examples in the field of cancer theranostics.


Assuntos
Nanopartículas , Fótons , Humanos , Nanopartículas/química , Corantes Fluorescentes/química , Animais , Neoplasias/diagnóstico por imagem , Neoplasias/diagnóstico , Imagem Óptica
9.
Mikrochim Acta ; 191(4): 225, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557876

RESUMO

An intelligent fluorescent nanoprobe (lignite-CDs-Eu) was constructed by an effective and facile method based on lignite-derived carbon dots (CDs) and lanthanide europium ions (Eu3+), which exhibited high sensitivity, low detection limit (13.35 nM) and visual color variation (from blue to red) under ultraviolet light towards tetracycline (TC) detection. Significantly, portable and economical sensors were developed using lignite-CDs-Eu immobilized fiber material of filter paper and wearable glove with the aid of color extracting and image processing application (APP) in the smartphone. Facile, fast and real-time visual detection of TC in food samples was realized. Moreover, logic gate circuit was also designed to achieve intelligent and semi-quantitative inspection of TC. To some extent, this study extended the cross-application of intelligent computer software in food analytical science, and provided a certain reference for the development of small portable detection sensors which were suitable for convenience and non-professional use in daily life.


Assuntos
Elementos da Série dos Lantanídeos , Tetraciclina , Antibacterianos , Európio , Carvão Mineral
10.
Mikrochim Acta ; 191(4): 199, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483615

RESUMO

An innovative triple optical sensor is presented that utilizes gold nanoclusters (GNCs) stabilized with ciprofloxacin (CIP) and bovine serum albumin (BSA). The sensor is designed to identify three critical metal ions, namely Cu2+, Al3+, and Hg2+. Under 360 nm excitation, the synthesized CIP-BSA-GNCs demonstrate dual fluorescence emission with peaks at 448 nm (blue) and 612 nm (red). The red emission is associated with the interior of the CIP-BSA-GNCs, whereas the blue emission results from the surface-bound CIP molecules. The sensitive and selective fluorescent nanosensor CIP-BSA-GNCs were employed to detect Cu2+, Al3+, and Hg2+ ions. Cu2+ effectively quenched the fluorescence intensity of the CIP-BSA-GNCs at both peaks via the internal charge transfer mechanism (ICT). Cu2+ could be detected within the concentration range 1.13 × 10-3 to 0.05 µM, with a detection limit of 0.34 nM. Al3+ increased the intensity of CIP fluorescence at 448 nm via the chelation-induced fluorescence enhancement mechanism. The fluorescence intensity of the core CIP-BSA-GNCs at 612 nm was utilized as a reference signal. Thus, the ratiometric detection of Al3+ succeeded with a limit of detection of 0.21 nM within the dynamic range 0.69 × 10-3 to 0.07 µM. Hg2+ effectively quenched the fluorescence intensity of the CIP-BSA-GNCs at 612 nm via the metallophilic interaction mechanism. The fluorescence intensity of CIP molecules at 448 nm was utilized as a reference signal. This allowed for the ratiometric detection of Hg2+ with a detection limit of 0.7 nM within the concentration range 2.3 × 10-3 to 0.1 µM.


Assuntos
Mercúrio , Nanopartículas Metálicas , Ouro , Ciprofloxacina , Espectrometria de Fluorescência/métodos , Corantes Fluorescentes , Soroalbumina Bovina , Íons
11.
Mikrochim Acta ; 191(6): 299, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709371

RESUMO

Gold nanoclusters are a smart platform for sensing potassium ions (K+). They have been synthesized using bovine serum albumin (BSA) and valinomycin (Val) to protect and cap the nanoclusters. The nanoclusters (Val-AuNCs) produced have a red emission at 616 nm under excitation with 470 nm. In the presence of K+, the valinomycin polar groups switch to the molecule's interior by complexing with K+, forming a bracelet structure, and being surrounded by the hydrophobic exterior conformation. This structure allows a proposed fluorometric method for detecting K+ by switching between the Val-AuNCs' hydrophilicity and hydrophobicity, which induces the aggregation of gold nanoclusters. As a result, significant quenching is seen in fluorescence after adding K+. The quenching in fluorescence in the presence of K+ is attributed to the aggregation mechanism. This sensing technique provides a highly precise and selective sensing method for K+ in the range 0.78 to 8 µM with LOD equal to 233 nM. The selectivity of Val-AuNCs toward K+ ions was investigated compared to other ions. Furthermore, the Val-AuNCs have novel possibilities as favorable sensor candidates for various imaging applications. Our detection technique was validated by determining K+ ions in postmortem vitreous humor samples, which yielded promising results.


Assuntos
Corantes Fluorescentes , Ouro , Nanopartículas Metálicas , Potássio , Soroalbumina Bovina , Valinomicina , Ouro/química , Valinomicina/química , Potássio/análise , Potássio/química , Nanopartículas Metálicas/química , Soroalbumina Bovina/química , Corantes Fluorescentes/química , Espectrometria de Fluorescência/métodos , Limite de Detecção , Animais , Interações Hidrofóbicas e Hidrofílicas , Bovinos
12.
Mikrochim Acta ; 191(8): 494, 2024 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-39073465

RESUMO

Hyperproliferative  diseases are the first step for tumor formation; thymidine kinase 1 (TK1) mRNA is closely related to cell proliferation. Therefore, the risk of malignant proliferation can be identified by sensitively detecting the variance in TK1 mRNA concentration, which can be used for tumor auxiliary diagnosis and monitoring tumor treatment. Owing to the low abundance and instability of TK1 mRNA in real samples, the development of a sensitive and fast mRNA detection method is necessary. A DNA nanosensor that can be used for detecting TK1 mRNA based on bipedal 3D DNA walker-driven proximal catalytic hairpin assembly (P-CHA) was developed. P-CHA hairpins were hybridized to a linker DNA strand coupled with magnetic nanoparticles to increase their local concentrations. The bipedal DNA walking on the surface of NPs accelerates reaction kinetics using the proximity effect. Taking advantage of the signal amplification of P-CHA as well as the rapid reaction rate of the DNA walker in 80 min, the proposed sensor detects TK1 mRNA with a low detection limit of 14 pM and may then be applied to clinical diagnosis.


Assuntos
Técnicas Biossensoriais , DNA , Limite de Detecção , RNA Mensageiro , Timidina Quinase , RNA Mensageiro/genética , RNA Mensageiro/química , Timidina Quinase/genética , Humanos , Técnicas Biossensoriais/métodos , DNA/química , DNA/genética , Hibridização de Ácido Nucleico , Nanopartículas de Magnetita/química
13.
Sensors (Basel) ; 24(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38676201

RESUMO

This paper presents an enhanced version of our previously developed bio-optical transceiver, presenting a significant advancement in nanosensor technology. Using self-assembled polymers, this nanodevice is capable of electron detection while maintaining biocompatibility, an essential feature for in vivo medical biosensors. This enhancement finds significance in the field of infectious disease control, particularly in the early detection of respiratory viruses, including high-threat pathogens such as SARS-CoV-2. The proposed system harnesses bioluminescence by converting electric signaling to visible blue light, effectively opening the path of linking nano-sized mechanisms to larger-scale systems, thereby pushing the boundaries of in vivo biomedical sensing. The performance evaluation of our technology is analytical and is based on the use of Markov chains, through which we assess the bit error probability. The calculated improvements indicate that this technology qualifies as a forerunner in terms of supporting the communication needs of smaller, safer, and more efficient manufactured sensor technologies for in vivo medical applications.


Assuntos
Técnicas Biossensoriais , COVID-19 , SARS-CoV-2 , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Humanos , Desenho de Equipamento , Polímeros/química , Cadeias de Markov
14.
Nano Lett ; 23(3): 916-924, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36651830

RESUMO

Gibberellins (GAs) are a class of phytohormones, important for plant growth, and very difficult to distinguish because of their similarity in chemical structures. Herein, we develop the first nanosensors for GAs by designing and engineering polymer-wrapped single-walled carbon nanotubes (SWNTs) with unique corona phases that selectively bind to bioactive GAs, GA3 and GA4, triggering near-infrared (NIR) fluorescence intensity changes. Using a new coupled Raman/NIR fluorimeter that enables self-referencing of nanosensor NIR fluorescence with its Raman G-band, we demonstrated detection of cellular GA in Arabidopsis, lettuce, and basil roots. The nanosensors reported increased endogenous GA levels in transgenic Arabidopsis mutants that overexpress GA and in emerging lateral roots. Our approach allows rapid spatiotemporal detection of GA across species. The reversible sensor captured the decreasing GA levels in salt-treated lettuce roots, which correlated remarkably with fresh weight changes. This work demonstrates the potential for nanosensors to solve longstanding problems in plant biotechnology.


Assuntos
Arabidopsis , Nanotubos de Carbono , Giberelinas/química , Giberelinas/metabolismo , Reguladores de Crescimento de Plantas/metabolismo , Arabidopsis/metabolismo , Nanotubos de Carbono/química , Fluorescência , Corantes
15.
Nano Lett ; 23(10): 4548-4556, 2023 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-37133308

RESUMO

Real-time fluorescence sensing can provide insight into biodynamics. However, few fluorescent tools are available to overcome the tissue scattering and autofluorescence interference for high-contrast in vivo sensing with high spatiotemporal resolution. Here, we develop a molecular-based FRET nanosensor (MFN) capable of producing a dynamic ratiometric NIR-IIb (1500-1700 nm) fluorescence signal under a frequency-modulated dual-wavelength excitation bioimaging system. The MFN provides reliable signals in highly scattering tissues and enables in vivo real-time imaging at micrometer-scale spatial resolution and millisecond-scale temporal resolution. As a proof of concept, a physiological pH-responsive nanosensor (MFNpH) was designed as a nanoreporter for intravital real-time monitoring of the endocytosis dynamics of nanoparticles in the tumor microenvironment. We also show that MFNpH allows the accurate quantification of pH changes in a solid tumor through video-rate ratiometric imaging. Our study offers a powerful approach for noninvasive imaging and sensing of biodynamics with micrometer-scale spatial resolution and millisecond-scale temporal resolution.


Assuntos
Corantes Fluorescentes , Nanopartículas , Transferência Ressonante de Energia de Fluorescência , Diagnóstico por Imagem , Imagem Óptica
16.
Nano Lett ; 23(10): 4142-4151, 2023 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-37134017

RESUMO

Natural killer (NK) cells undergo multiple DNA genomic alterations, especially methylation-based modifications that affect activation and function. Several epigenetic modifier markers have been targeted for immunotherapy to date, but the possibility of cancer diagnosis using NK cell's DNA has been overlooked. Here, we investigated the potential use of NK cell DNA genome modifications as markers for the diagnosis of colorectal cancer (CRC) and validated their efficacy in CRC patients. Using Raman spectroscopy as the detection methodology, we identified CRC-specific methylation signatures by comparing CRC-interacted NK cells to healthy circulating NK cells. Subsequently, we identified methylation-dependent alterations in these NK cell populations. These markers were then utilized by a machine learning algorithm to develop a diagnostic model with predictive capabilities. The diagnostic prediction model accurately differentiated CRC patients from normal controls. Our findings demonstrated the utility of NK DNA markers in the diagnosis of CRC.


Assuntos
Neoplasias Colorretais , Metilação de DNA , Humanos , Neoplasias Colorretais/genética , Células Matadoras Naturais , DNA/genética , Biomarcadores Tumorais/genética
17.
Anal Biochem ; 679: 115285, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37586674

RESUMO

Inadequate folic acid intake is linked to diseases such as megaloblastic anemia, neural tube defects, and hyperhomocysteinemia, increasing the risk of vascular disease and thrombosis. Folic acid, a cofactor in various enzymes, can be produced by plants and bacteria, but not by humans and other animals. L-5-methyl-tetrahydrofolate (L-5-methyl-THF) is the primary dietary folate form, transported in circulation for cellular metabolism. Traditional methods of determining folic acid levels are unreliable and time-consuming. SenFol (Sensor for folic acid) is a fluorescence resonance energy transfer (FRET)-based nanosensor that we have developed by inserting folic acid-binding protein (FolT) as the folate detecting domain between the pair of enhanced cyan fluorescent protein (ECFP) and Venus. The developed sensor is highly specific, produces a quick signal, which is pH stable, and delivers precise, ratiometric readings in cell-based experiments. The projected affinity score of folic acid with FolT was -7.4 kcal/mol. The apparent affinity (Kd) of SenFol for folic acid is 28.49 × 10-9 M, with a detection range of 5 × 10-9 M to 5 × 10-7 M, and a maximum FRET ratio change of 0.45. WT SenFol, a highly efficient folic acid nanosensor, can dynamically detect intracellular folic acid content in E. coli, yeast, and HEK-293 T cells, confirming its potential.


Assuntos
Escherichia coli , Ácido Fólico , Humanos , Animais , Escherichia coli/química , Transferência Ressonante de Energia de Fluorescência/métodos , Células HEK293 , Diagnóstico por Imagem , Saccharomyces cerevisiae/metabolismo
18.
Anal Biochem ; 677: 115268, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37524223

RESUMO

A polymer-based nanosensor and electrochemical methods were developed for the quantitative analysis of vanillin. The sample preparation was done using nano solid phase micro membrane tip extraction (NSPMMTE). A novel poly(phenylalanine)/TiO2/CPE sensor was built as the working electrode for the first time for the analysis of the vanillin substance. The electrochemical behavior and analytical performance of vanillin were examined in detail by cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV) techniques via the oxidation process. The optimized modules of the DPSV technique that affected the vanillin peak current and peak potential were pH, pulse amplitude, step potential, and deposition time. The electroactive surface areas of bare CPE, TiO2/CPE, and poly(phenylalanine)/TiO2/CPE electrodes were found to be 0.135 cm2, 0.155 cm2, and 0.221 cm2, respectively. The limit of detection (LOD) was 32.6 µg/L in the 0.25-15.0 mg/L working range at pH 7.0. The selectivity of the proposed DPSV method for the determination of vanillin on the modified electrode was investigated in the presence of various organic and inorganic substances, and the determination of vanillin with high recovery was achieved with less than 5% relative error. The analytical application was applied in chocolate samples and the DPSV method was found highly efficient, reproducible, and selective.


Assuntos
Chocolate , Titânio/química , Polímeros/química , Técnicas Eletroquímicas/métodos , Eletrodos , Carbono/química
19.
J Fluoresc ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37976022

RESUMO

In this study, salicylaldehyde (SA) conjugated gold nanoclusters were synthesized, characterized, and applied for the fluorescent turn-on sensing of Cd2+. The trypsin-stabilized fluorescent gold nanocluster (Tryp-AuNCs, λem = 680 nm) was modified with SA to form the spherical-shaped SA_Tryp-AuNCs. After modification, the red-emitting Tryp-AuNCs turned to green-emitting SA_Tryp-AuNCs because of the formation of imine linkage between the -CHO group of SA with the -NH2 group of functionalized trypsin. The modified SA_Tryp-AuNCs selectively interacted with Cd2+ and exhibited a fluorescence enhancement at 660 nm. The Cd2+ detection with SA_Tryp-AuNCs is simple and rapid with an estimated nanomolar detection limit of 98.1 nM. The practical utility of SA_Tryp-AuNCs was validated by quantifying Cd2+ in real environmental water samples.

20.
J Fluoresc ; 33(2): 653-661, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36480126

RESUMO

Accurate monitoring of intracellular pH in living cells is critical for developing a better understanding of cellular activities. In the current study, label-free carbon dots (p-CDs), which were fabricated using a straightforward one-pot solvothermal treatment of p-phenylenediamine and urea, were employed to create a new ratiometric pH nanosensor. Under single-wavelength excitation (λex = 500 nm), the p-CDs gave dual emission bands at 525 and 623 nm. The fluorescent intensity ratio (I525/I623) was linearly related to pH over the range 4.0 to 8.8 in buffer solutions, indicating that the ratiometric fluorescence nanoprobe may be useful for pH sensing. In pH measurements, the p-CDs also demonstrated outstanding selectivity, reversibility, and photostability. Owing to the advantages outlined above, the nanoprobe was used to monitor the pH of HeLa cells effectively. The label-free CD-based ratiometric nanoprobe features comparatively easy manufacturing and longer excitation and emission wavelengths than the majority of previously reported CD-based ratiometric pH sensors, which is ultimately beneficial for applications in biological imaging.


Assuntos
Pontos Quânticos , Humanos , Células HeLa , Carbono , Corantes Fluorescentes , Concentração de Íons de Hidrogênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA