Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 625
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(49): e2302903120, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38015852

RESUMO

Uncontrolled type 2 immunity by type 2 helper T (Th2) cells causes intractable allergic diseases; however, whether the interaction of CD4+ T cells shapes the pathophysiology of allergic diseases remains unclear. We identified a subset of Th2 cells that produced the serine proteases granzyme A and B early in differentiation. Granzymes cleave protease-activated receptor (Par)-1 and induce phosphorylation of p38 mitogen-activated protein kinase (MAPK), resulting in the enhanced production of IL-5 and IL-13 in both mouse and human Th2 cells. Ubiquitin-specific protease 7 (USP7) regulates IL-4-induced phosphorylation of STAT3, resulting in granzyme production during Th2 cell differentiation. Genetic deletion of Usp7 or Gzma and pharmacological blockade of granzyme B ameliorated allergic airway inflammation. Furthermore, PAR-1+ and granzyme+ Th2 cells were colocalized in nasal polyps from patients with eosinophilic chronic rhinosinusitis. Thus, the USP7-STAT3-granzymes-Par-1 pathway is a potential therapeutic target for intractable allergic diseases.


Assuntos
Hipersensibilidade , Células Th2 , Humanos , Animais , Camundongos , Granzimas/genética , Granzimas/metabolismo , Interleucina-5/metabolismo , Peptidase 7 Específica de Ubiquitina/metabolismo , Inflamação/metabolismo , Diferenciação Celular , Fator de Transcrição STAT3/genética , Fator de Transcrição STAT3/metabolismo
2.
J Biol Chem ; 299(6): 104819, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37187292

RESUMO

Severe fever with thrombocytopenia syndrome virus (SFTSV), which has been reported in China, Korea, Japan, Vietnam, and Taiwan, is a causative agent of severe fever thrombocytopenia syndrome. This virus has a high mortality and induces thrombocytopenia and leukocytopenia in humans, cats, and aged ferrets, whereas immunocompetent adult mice infected with SFTSV never show symptoms. Anti-SFTSV antibodies have been detected in several animals-including goats, sheep, cattle, and pigs. However, there are no reports of severe fever thrombocytopenia syndrome in these animals. Previous studies have reported that the nonstructural protein NSs of SFTSV inhibits the type I interferon (IFN-I) response through the sequestration of human signal transducer and activator of transcription (STAT) proteins. In this study, comparative analysis of the function of NSs as IFN antagonists in human, cat, dog, ferret, mouse, and pig cells revealed a correlation between pathogenicity of SFTSV and the function of NSs in each animal. Furthermore, we found that the inhibition of IFN-I signaling and phosphorylation of STAT1 and STAT2 by NSs depended on the binding ability of NSs to STAT1 and STAT2. Our results imply that the function of NSs in antagonizing STAT2 determines the species-specific pathogenicity of SFTSV.


Assuntos
Interferon Tipo I , Phlebovirus , Febre Grave com Síndrome de Trombocitopenia , Proteínas não Estruturais Virais , Idoso , Animais , Bovinos , Cães , Humanos , Camundongos , Furões , Interferon Tipo I/metabolismo , Phlebovirus/fisiologia , Febre Grave com Síndrome de Trombocitopenia/virologia , Ovinos , Transdução de Sinais , Suínos , Trombocitopenia/metabolismo , Proteínas não Estruturais Virais/metabolismo
3.
J Vasc Res ; : 1-8, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39074454

RESUMO

INTRODUCTION: Current microvascular assessments may not be practical or accessible requiring experienced personnel and/or ongoing equipment costs. Piezoelectric transducers can reliably obtain finger blood pressure waves, similar to peripheral arterial tonometry devices; thus, they could be used to estimate microvascular function. We aimed to validate piezoelectric transducers as an alternative measure of microvascular function compared to EndoPAT. METHODS: Twenty-five adults (aged 20-64 years) completed reactive hyperemia (5 min forearm circulatory occlusion and 3 min recovery) with piezoelectric transducers on the middle fingers and EndoPAT probes on the index fingers. Average area under the curve (AUC) of the pulse wave signal for the occluded and control arms was determined at baseline, every 30 s post-occlusion, and 10 s around the peak response. Microvascular function index (MFI) was calculated as the ratio of AUC post-occlusion to AUC baseline in the test arm, then normalized to the same ratio in the control arm. MFI at each time point was correlated with the reactive hyperemia index (RHI) from the EndoPAT. RESULTS: The greatest significance was found between RHI and MFI at 10 s around the peak response (Spearman's r = 0.67, p = 0.0002; Pearson's r = 0.76, p = 0.00001). CONCLUSION: MFI is a reusable and user-friendly microvascular function assessment that could provide better access to vascular health screening.

4.
Pediatr Radiol ; 54(5): 737-742, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38418631

RESUMO

BACKGROUND: Ultrasound is the modality of choice for the diagnosis of hypertrophic pyloric stenosis (HPS). The evolution of high-frequency transducers in ultrasound has led to inconsistent ways of measuring the pylorus. OBJECTIVE: To standardize the measurements and evaluate the appearance of the normal and hypertrophied pylorus with high-frequency transducers. MATERIALS AND METHODS: We retrospectively analyzed abdominal ultrasounds of infants with suspected HPS from January 2019-December 2020. We classified the layers of the pylorus while assessing the stratified appearance. Two pediatric radiologists measured the muscle thickness of the pylorus independently by two methods for interrater agreement. Measurement (a) includes the muscularis propria and muscularis mucosa. Measurement (b) includes only the muscularis propria. We also evaluated the echogenicity of the muscularis propria. The interrater agreement, mean, range of the muscle thickness, and the diagnostic accuracy of the two sets of measurements were calculated. RESULTS: We included 300 infants (114 F:186 M), 59 with HPS and 241 normal cases. There was a strong agreement between the readers assessed in the first 100 cases, and ICC was 0.99 (95% CI, 0.98-0.99). Measurement (a), median thickness is 2.4 mm in normal cases and 4.8 mm in HPS. Measurement (b), median thickness is 1.4 mm in normal cases and 4.0 mm in HPS. Measurement (a) has an accuracy of 89.7% (95% CI, 85.7-92.8%) with 98.3% sensitivity and 87.6% specificity. Measurement (b) has an accuracy of 98.0% (95% CI, 95.7-99.3%) with 89.8% sensitivity and 100.0% specificity. The pylorus stratification is preserved in all normal cases and 31/59 (52.5%) cases of HPS. There was complete/partial loss of stratification in 28/59 (47.5%) cases of HPS. In all HPS cases, the muscularis propria was echogenic. CONCLUSION: Measuring the muscularis propria solely has a better diagnostic accuracy, decreasing the overlap of negative and positive cases. The loss of pyloric wall stratification and echogenic muscularis propria is only seen in HPS.


Assuntos
Estenose Pilórica Hipertrófica , Piloro , Transdutores , Ultrassonografia , Humanos , Estudos Retrospectivos , Masculino , Feminino , Ultrassonografia/métodos , Piloro/diagnóstico por imagem , Lactente , Estenose Pilórica Hipertrófica/diagnóstico por imagem , Recém-Nascido , Sensibilidade e Especificidade
5.
Neurocrit Care ; 40(2): 391-394, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37697130

RESUMO

Intracranial pressure is routinely monitored in most intensive care units caring for patients with severe neurological insults and, together with continuous arterial blood pressure measurement, allows for monitoring of cerebral perfusion pressure (CPP). CPP is the driving pressure of blood flow to the brain and is used to guide therapy. However, there is considerable inconsistency in the literature regarding how CPP is technically measured and, more specifically, the appropriate placement of the arterial pressure transducer. Depending on patient positioning and where the arterial pressure transducer is placed, the mean arterial pressure used for CPP calculation can vary widely by up to 15 mm Hg, which is greater than the acceptable variation in target ranges used clinically. Physiologically, the arterial pressure transducer should be placed at the level of the foramen of Monro for CPP measurement, but it is commonly set at the level of the right atrium for systematic measurement. Mean arterial pressure measurement at the level of the right atrium can lead to overestimation and potentially critically low actual CPP levels when the head is elevated, and measurement at the level of the foramen of Monro will underestimate systemic pressures, increasing the risk of excessive and unnecessary use of vasopressors and fluid. At the Karolinska University Hospital neurointensive care unit, we have used a split dual-transducer system, measuring arterial pressure both at the level of the foramen of Monro and at the level of the right atrium from a single arterial source. In doing so, we work with constants and can monitor and target optimum arterial pressures to better secure perfusion to all organs, with potentially less risk of cerebral ischemia or overuse of vasopressors and fluids, which may affect outcome.


Assuntos
Pressão Arterial , Circulação Cerebrovascular , Humanos , Circulação Cerebrovascular/fisiologia , Pressão Arterial/fisiologia , Pressão Intracraniana/fisiologia , Posicionamento do Paciente , Unidades de Terapia Intensiva , Vasoconstritores/uso terapêutico , Pressão Sanguínea/fisiologia , Monitorização Fisiológica
6.
Sensors (Basel) ; 24(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38544220

RESUMO

In the process of activating non-conductive smart-structures using piezoelectric patches, one possible method is to add a conductive layer to ensure electrical contact of both electrodes of the ceramic. Therefore, depending on the stiffness and the thickness of this layer, changes in the overall piezoelectric properties lead to a loss in the electromechanical coupling that can be implemented. The purpose of this work is to study the impact of this added electrode layer depending on its thickness. A model of the effect of this layer on the piezoelectrical coefficients has been derived from the previous approach of Hashimoto and Yamagushi and successfully compared to experimental data. This global model computes the variation of all the piezoelectric coefficients, and more precisely of k31 or d31 for various brass electrode volumes relative to the ceramic volume. A decrease in the lateral electromechanical coupling factor k31 was observed and quantified. NAVY II PZT piezoelectric transducers were characterized using IEEE standard methods, with brass electrode thicknesses ranging from 50 to 400 microns. The model fits very well as shown by the results, leading to good expectations for the use of this design approach for actuators or sensors embedded in smart-structures.

7.
Sensors (Basel) ; 24(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38475107

RESUMO

In the last two decades, many research works have been focused on enhancing the properties of gas sensors by utilising external triggers like temperature and light. Most interestingly, the light-activated gas sensors show promising results, particularly using visible light as an external trigger that lowers the power consumption as well as improves the stability, sensitivity and safety of the sensors. It effectively eliminates the possible damage to sensing material caused by high operating temperature or high energy light. This review summarises the effect of visible light illumination on both chemoresistors and heterostructure gas sensors based on inorganic and organic materials and provides a clear understanding of the involved phenomena. Finally, the fascinating concept of ambipolar gas sensors is presented, which utilised visible light as an external trigger for inversion in the nature of majority charge carriers in devices. This review should offer insight into the current technologies and offer a new perspective towards future development utilising visible light in light-assisted gas sensors.

8.
Sensors (Basel) ; 24(8)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38676124

RESUMO

Electric-field energy harvesters (EFEHs) have emerged as a promising technology for harnessing the electric field surrounding energized environments. Current research indicates that EFEHs are closely associated with Tribo-Electric Nano-Generators (TENGs). However, the performance of TENGs in energized environments remains unclear. This work aims to evaluate the performance of TENGs in electric-field energy harvesting applications. For this purpose, TENGs of different sizes, operating in single-electrode mode were conceptualized, assembled, and experimentally tested. Each TENG was mounted on a 1.5 HP single-phase induction motor, operating at nominal parameters of 8 A, 230 V, and 50 Hz. In addition, the contact layer was mounted on a linear motor to control kinematic stimuli. The TENGs successfully induced electric fields and provided satisfactory performance to collect electrostatic charges in fairly variable electric fields. Experimental findings disclosed an approximate increase in energy collection ranging from 1.51% to 10.49% when utilizing TENGs compared to simple EFEHs. The observed correlation between power density and electric field highlights TENGs as a more efficient energy source in electrified environments compared to EFEHs, thereby contributing to the ongoing research objectives of the authors.

9.
Sensors (Basel) ; 24(14)2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39065947

RESUMO

To investigate the effects of long-term prestress loss on concrete box girders strengthened with external prestressing, a large-span box girder, in service for over 20 years and strengthened with external prestressing, was monitored for four months. Prestress loss in the longitudinal, vertical, and transverse directions of the box girder was calculated according to Chinese code requirements. Magnetic flux rope force transducers were used to monitor the prestress loss in the external prestressing cables. Fiber Bragg Grating (FBG) sensors were used to monitor deflection changes at the mid-span of the bridge. Finally, the effect of prestress loss in the longitudinal, vertical, and transverse tendons on mid-span deflection was investigated through simulations using ABAQUS software. The results show that instantaneous prestress loss accounts for most of the total loss compared to long-term loss, and that longitudinal prestress loss has the most significant effect on mid-span deflection. The impact of longitudinal prestress loss on deflection before and after strengthening was also compared. The downward deflection and up-ward arch caused by longitudinal tendon prestress loss were reduced after strengthening, con-firming the effectiveness of the external prestressing method.

10.
Sensors (Basel) ; 24(14)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39066089

RESUMO

This study employs the transmitter part of an ultrasonic proximity sensor to generate a powerful ultrasonic field for medical humidification. This field is created using an arrangement of small ultrasonic transmitter transducers configured in an acoustic levitator-style setup. As droplets pass through this ultrasonic field, they undergo disintegration, leading to an accelerated evaporation process. The research findings highlight a significant change in droplet size distribution due to ultrasonics, resulting in a notable increase in the rate of evaporation. As a result, this study presents a conceptual framework for reimagining humidification devices for lung therapeutic purposes through the utilization of simple sensor technology.

11.
Sensors (Basel) ; 24(13)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-39000971

RESUMO

Pipelines are an important transportation form in industry. However, pipeline corrosion, particularly that occurring internally, poses a significant threat to safe operations. To detect the internal corrosion of a pipeline, a method utilizing piezoelectric sensors alongside singular spectrum analysis is proposed. Two piezoelectric patches are affixed to the exterior surface of the pipeline, serving the roles of an actuator and a sensor, respectively. During the detection, the signals excited by the actuator are transmitted through the pipeline's wall and are received by PZT2 through different paths, and the corresponding piezoelectric sensor captures the signals. Then, the response signals are denoised by singular spectrum analysis, and the first several wave packets in the response signals are selected to establish a feature for pipeline corrosion detection. At last, the envelope area of the selected packets is calculated as a feature to detect corrosion. To validate the proposed method, corrosion monitoring experiments are performed. The experimental results indicate that the envelope area of the first several wave packets from the response signals, following singular spectrum analysis, can serve as a feature to assess the degree of pipeline corrosion, and the index has a monotonic relationship with the corrosion depth of the pipeline. This method provides an effective way for pipeline corrosion monitoring.

12.
Sensors (Basel) ; 24(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39001073

RESUMO

In this work, we have verified how non-destructive ultrasonic evaluation allows for acoustically characterizing different varieties of wine. For this, a 3.5 MHz transducer has been used by means of an immersion technique in pulse-echo mode. The tests were performed at various temperatures in the range 14-18 °C. The evaluation has been carried out studying, on the one hand, conventional analysis parameters (velocity and attenuation) and, on the other, less conventional parameters (frequency components). The experimental study comprised two stages. In the first, the feasibility of the study was checked by inspecting twelve samples belonging to six varieties of red and white wine. The results showed clearly higher ultrasonic propagation velocity values in the red wine samples. In the second, nine samples of different monovarietal wine varieties (Grenache, Tempranillo and Cabernet Sauvignon) were analyzed. The results show how ultrasonic velocity makes it possible to unequivocally classify the grape variety used in winemaking with the Cabernet Sauvignon variety having the highest values and the Grenache the lowest. In addition, the wines of the Tempranillo variety are those that present higher values of the attenuation coefficient, and those from the Grenache variety transmit higher frequency waves.

13.
Sensors (Basel) ; 24(13)2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-39000861

RESUMO

Ultrasonic focusing transducers have broad prospects in advanced ultrasonic non-destructive testing fields. However, conventional focusing methods that use acoustic concave lenses can disrupt the acoustic impedance matching condition, thereby adversely affecting the sensitivity of the transducers. In this paper, an active focusing planar ultrasonic transducer is designed and presented to achieve a focusing effect with a higher sensitivity. An electrode pattern consisting of multiple concentric rings is designed, which is inspired by the structure of Fresnel Zone Plates (FZP). The structural parameters are optimized using finite element simulation methods. A prototype of the transducer is manufactured with electrode patterns made of conductive silver paste using silk screen-printing technology. Conventional focusing transducers using an acoustic lens and an FZP baffle are also manufactured, and their focusing performances are comparatively tested. The experimental results show that our novel transducer has a focal length of 16 mm and a center frequency of 1.16 MHz, and that the sensitivity is improved by 23.3% compared with the conventional focusing transducers. This research provides a new approach for the design of focusing transducers.

14.
Sensors (Basel) ; 24(6)2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38544191

RESUMO

The early detection of small cracks in large metal structures is a crucial requirement for the implementation of a structural health monitoring (SHM) system with a low transducers density. This work tackles the challenging problem of the early detection of submillimeter notch-type defects with a semielliptical shape and a groove at a constant width of 100 µm and 3 mm depth in a 4.1 mm thick aluminum plate. This defect is investigated with an ultrasonic guided wave (UGW) A0 mode at 550 kHz to investigate the long range in thick metal plates. The mode selection is obtained by interdigital transducers (IDTs) designed to operate with a 5 mm central wavelength. The novel contribution is the validation of the detection by pulse-echo and pitch and catch with UGW transducers to cover a distance up to 70 cm to reduce the transducers density. The analysis of scattering from this submillimeter defect at different orientations is carried out using simulations with a Finite Element Model (FEM). The detection of the defect is obtained by comparing the scattered signals from the defect with baseline signals of the pristine laminate. Finally, the paper shows that the simulated results are in good agreement with the experimental ones, demonstrating the possible implementation in an SHM system based on the efficient propagation of an antisymmetric mode by IDTs.

15.
Sensors (Basel) ; 24(11)2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38894377

RESUMO

Reliable testing of aviation components depends on the quality and configuration flexibility of measurement systems. In a typical approach to test instrumentation, there are tens or hundreds of sensors on the test head and test facility, which are connected by wires to measurement cards in control cabinets. The preparation of wiring and the setup of measurement systems are laborious tasks requiring diligence. The use of smart wireless transducers allows for a new approach to test preparation by reducing the number of wires. Moreover, additional functionalities like data processing, alarm-level monitoring, compensation, or self-diagnosis could improve the functionality and accuracy of measurement systems. A combination of low power consumption, wireless communication, and wireless power transfer could speed up the test-rig instrumentation process and bring new test possibilities, e.g., long-term testing of moving or rotating components. This paper presents the design of a wireless smart transducer dedicated for use with sensors typical of aviation laboratories such as thermocouples, RTDs (Resistance Temperature Detectors), strain gauges, and voltage output integrated sensors. The following sections present various design requirements, proposed technical solutions, a study of battery and wireless power supply possibilities, assembly, and test results. All presented tests were carried out in the Components Test Laboratory located at the Lukasiewicz Research Network-Institute of Aviation.

16.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732819

RESUMO

In this paper, we present a novel three-dimensional (3D) coupled configuration of piezoelectric micromachined ultrasound transducers (pMUTs) by combing a curved and an annular diaphragm for transmit performance optimization in biomedical applications. An analytical equivalent circuit model (EQC) is developed with varied excitation methods to incorporate the acoustic-structure coupling of the curved and annular diaphragm-coupled pMUTs (CAC-pMUTs). The model-derived results align well with the reference simulated by the finite element method (FEM). Using this EQC model, we optimize the key design parameters of the CAC-pMUTs in order to improve the output sound pressure, including the width of the annular membrane, the thickness of the passive layer, and the phase difference of the driving voltage. In the anti-phase mode, the designed CAC-pMUTs demonstrate a transmit efficiency 285 times higher than that of single annular pMUTs. This substantial improvement underscores the potential of CAC-pMUTs for large array applications.

17.
Int Immunol ; 34(6): 303-312, 2022 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-35192696

RESUMO

Jak3, a member of the Janus kinase family, is essential for the cytokine receptor common gamma chain (γc)-mediated signaling. During activation of Jak3, tyrosine residues are phosphorylated and potentially regulate its kinase activity. We identified a novel tyrosine phosphorylation site within mouse Jak3, Y820, which is conserved in human Jak3, Y824. IL-2-induced tyrosine phosphorylation of Jak3 Y824 in human T cell line HuT78 cells was detected by using a phosphospecific, pY824, antibody. Mutation of mouse Jak3 Y820 to alanine (Y820A) showed increased autophosphorylation of Jak3 and enhanced signal transducer and activator of transcription 5 (STAT5) tyrosine phosphorylation and transcriptional activation. Stably expressed Jak3 Y820A in F7 cells, an IL-2 responsive mouse pro-B cell line Ba/F3, exhibited enhanced IL-2-dependent cell growth. Mechanistic studies demonstrated that interaction between Jak3 and STAT5 increased in Jak3 Y820A compared to wild-type Jak3. These data suggest that Jak3 Y820 plays a role in negative regulation of Jak3-mediated STAT5 signaling cascade upon IL-2-stimulation. We speculate that this occurs through an interaction promoted by the tyrosine phosphorylated Y820 or a conformational change by Y820 mutation with either the STAT directly or with the recruitment of molecules such as phosphatases via a SH2 interaction. Additional studies will focus on these interactions as Jak3 plays a crucial role in disease and health.


Assuntos
Fator de Transcrição STAT5 , Tirosina , Animais , Interleucina-2/metabolismo , Interleucina-2/farmacologia , Janus Quinase 3 , Camundongos , Proteínas do Leite/metabolismo , Fosforilação , Fator de Transcrição STAT5/metabolismo , Transdução de Sinais
18.
Anal Bioanal Chem ; 415(22): 5451-5462, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37389600

RESUMO

One of the most important reasons for an increased mortality rate of cancer is late diagnosis. Point-of-care (POC) diagnostic sensors can provide rapid and cost-effective diagnosis and monitoring of cancer biomarkers. Portable, disposable, and sensitive sarcosine solid-contact ion-selective potentiometric sensors (SC-ISEs) were fabricated as POC analyzers for the rapid determination of the prostate cancer biomarker sarcosine. Tungsten trioxide nanoparticles (WO3 NPs), polyaniline nanoparticles (PANI NPs), and PANI-WO3 nanocomposite were used as ion-to-electron transducers on screen-printed sensors. WO3 NPs and PANI-WO3 nanocomposite have not been investigated before as ion-to-electron transducer layers in potentiometric SC sensors. The designated sensors were characterized using SEM, XRD, FTIR, UV-VIS spectroscopy, and EIS. The inclusion of WO3 and PANI in SC sensors enhanced the transduction at the interface between the screen-printed SC and the ion-selective membrane, offering lower potential drift, a longer lifetime, shorter response time, and better sensitivity. The proposed sarcosine sensors exhibited Nernstian slopes over linear response ranges 10-3-10-7 M, 10-3-10-8 M, 10-5-10-9 M, and 10-7-10-12 M for control, WO3 NPs, PANI NPs, and PANI-WO3 nanocomposite-based sensors, respectively. From a comparative point of view between the four sensors, PANI-WO3 nanocomposite inclusion offered the lowest potential drift (0.5 mV h-1), the longest lifetime (4 months), and the best LOD (9.95 × 10-13 M). The proposed sensors were successfully applied to determine sarcosine as a potential prostate cancer biomarker in urine without prior sample treatment steps. The WHO ASSURED criteria for point-of-care diagnostics are met by the proposed sensors.


Assuntos
Nanocompostos , Neoplasias da Próstata , Masculino , Humanos , Biomarcadores Tumorais , Sarcosina , Próstata , Polímeros/química , Óxidos/química , Neoplasias da Próstata/diagnóstico , Testes Imediatos , Nanocompostos/química
19.
Sensors (Basel) ; 23(6)2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36991752

RESUMO

Piezoelectric transducers have numerous applications in a wide range of sensing and actuation applications. Such a variety has resulted in continuous research into the design and development of these transducers, including but not limited to their geometry, material and configuration. Among these, cylindrical-shaped piezoelectric PZT transducers with superior features are suitable for various sensor or actuator applications. However, despite their strong potential, they have not been thoroughly investigated and fully established. The aim of this paper is to shed light on various cylindrical piezoelectric PZT transducers, their applications and design configurations. Based on the latest literature, different design configurations such as stepped-thickness cylindrical transducers and their potential application areas will be elaborated on to propose future research trends for introducing new configurations that meet the requirements for biomedical applications, the food industry, as well as other industrial fields.

20.
Sensors (Basel) ; 23(3)2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36772448

RESUMO

Dynamic muscular workload assessments of tractor operators are rarely studied or documented, which is critical to improving their performance efficiency and safety. A study was conducted to assess and model dynamic load on muscles, physiological variations, and discomfort of the tractor operators arriving from the repeated clutch and brake operations using wearable non-invasive ergonomic transducers and data-run techniques. Nineteen licensed tractor operators operated three different tractor types of varying power ranges at three operating speeds (4-5 km/h), and on two common operating surfaces (tarmacadam and farm roads). During these operations, ergonomic transducers were utilized to capture the load on foot muscles (gastrocnemius right [GR] and soleus right [SR] for brake operation and gastrocnemius left [GL], and soleus left [SL] for clutch operation) using electromyography (EMG). Forces exerted by the feet during brake and clutch operations were measured using a custom-developed foot transducer. During the process, heart rate (HR) and oxygen consumption rates (OCR) were also measured using HR monitor and K4b2 systems, and energy expenditure rate (EER) was determined using empirical equation. Post-tractor operation cycle, an overall discomfort rating (ODR) for that operation was manually recorded on a 10-point psychophysical scale. EMG-based maximum volumetric contraction (%MVC) measurements revealed higher strain on GR (%MVC = 43%), GL (%MVC = 38%), and SR (%MVC = 41%) muscles which in normal conditions should be below 30%. The clutch and brake actuation forces were recorded in the ranges of 90-312 N and 105-332 N, respectively and were significantly affected by the operating speed, tractor type, and operating surface (p < 0.05). EERs of the operators were measured in the moderate-heavy to heavy ranges (9-24 kJ/min) during the course of trials, suggesting the need to refine existing clutch and brake system designs. Average operator ODR responses indicated 7.8% operations in light, 48.5% in light-moderate, 25.2% in moderate, 10.7% in moderate-high, and 4.9% operations in high discomfort categories. When evaluated for the possibility of minimizing the number of transducers for physical workload assessment, EER showed moderate-high correlations with the EMG signals (rGR = 0.78, rGL = 0.75, rSR = 0.68, rSL = 0.66). Similarly, actuation forces had higher correlations with EMG signals for all the selected muscles (r = 0.70-0.87), suggesting the use of simpler transducers for effective operator workload assessment. As a means to minimize subjectivity in ODR responses, machine learning algorithms, including K-nearest neighbor (KNN), random forest classifier (RFC), and support vector machine (SVM), predicted the ODR using body mass index (BMI), HR, EER, and EMG at high accuracies of 87-97%, with RFC being the most accurate. Such high-throughput and data-run ergonomic evaluations can be instrumental in reconsidering workplace designs and better fits for end-users in terms of agricultural tractors and machinery systems.


Assuntos
Ergonomia , Carga de Trabalho , Músculo Esquelético/fisiologia , Eletromiografia , Agricultura , Aprendizado de Máquina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA