Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 341
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Infect Dis ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39383212

RESUMO

Post-kala-azar dermal leishmaniasis (PKDL) is a skin condition that occurs in a small percentage of people who have been cured of visceral leishmaniasis (VL), and contributes to transmission of VL. The rK39 rapid test cannot decisively diagnose PKDL due to presence of antileishmanial antibodies from past VL episodes. CL Detect™ Rapid Test, an in-vitro diagnostic test that detects Leishmania antigen peroxidoxin, was assessed for diagnosing PKDL. The CL Detect RDT had 73.3% sensitivity and 100% specificity in the study. The test can be used as a primary screening tool to monitor PKDL in endemic regions and identify active Leishmania infection.

2.
J Infect Dis ; 230(2): 363-373, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38531685

RESUMO

BACKGROUND: SARS-CoV-2 antigen-detection rapid diagnostic tests (Ag-RDTs) have become widely utilized but longitudinal characterization of their community-based performance remains incompletely understood. METHODS: This prospective longitudinal study at a large public university in Seattle, WA utilized remote enrollment, online surveys, and self-collected nasal swab specimens to evaluate Ag-RDT performance against real-time reverse transcription polymerase chain reaction (rRT-PCR) in the context of SARS-CoV-2 Omicron. Ag-RDT sensitivity and specificity within 1 day of rRT-PCR were evaluated by symptom status throughout the illness episode and Orf1b cycle threshold (Ct). RESULTS: From February to December 2022, 5757 participants reported 17 572 Ag-RDT results and completed 12 674 rRT-PCR tests, of which 995 (7.9%) were rRT-PCR positive. Overall sensitivity and specificity were 53.0% (95% confidence interval [CI], 49.6%-56.4%) and 98.8% (95% CI, 98.5%-99.0%), respectively. Sensitivity was comparatively higher for Ag-RDTs used 1 day after rRT-PCR (69.0%), 4-7 days after symptom onset (70.1%), and Orf1b Ct ≤20 (82.7%). Serial Ag-RDT sensitivity increased with repeat testing ≥2 (68.5%) and ≥4 (75.8%) days after an initial Ag-RDT-negative result. CONCLUSIONS: Ag-RDT performance varied by clinical characteristics and temporal testing patterns. Our findings support recommendations for serial testing following an initial Ag-RDT-negative result, especially among recently symptomatic persons or those at high risk for SARS-CoV-2 infection.


Assuntos
Teste Sorológico para COVID-19 , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Estudos Prospectivos , Estudos Longitudinais , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Teste Sorológico para COVID-19/métodos , Antígenos Virais/análise , Teste de Ácido Nucleico para COVID-19/métodos , Idoso , Washington , Adulto Jovem , Adolescente
3.
Eur J Clin Microbiol Infect Dis ; 43(1): 195-201, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37981632

RESUMO

The aim of this study was to assess the reliability of rapid antigen detection tests (RADT) for Streptococcus pyogenes (GAS) and Streptococcus pneumoniae on pleural fluid samples for diagnosis of parapneumonic effusion/empyema (PPE) and their potential for improving pathogen identification rates. Sixty-three pleural samples were included from 54 patients on which GAS and S. pneumoniae RADT (BinaxNOW), culture, 16S rRNA PCR, and S. pneumoniae-specific PCR were performed. GAS RADT showed a sensitivity of 95.2% and a specificity of 100%. Pneumococcal RADT showed a sensitivity of 100% and specificity of 88.6%. Both RADT increased the pathogen identification rate in PPE compared to culture.


Assuntos
Empiema Pleural , Empiema , Derrame Pleural , Humanos , Streptococcus pneumoniae/genética , Streptococcus pyogenes/genética , RNA Ribossômico 16S , Reprodutibilidade dos Testes , Empiema/diagnóstico , Derrame Pleural/diagnóstico , Derrame Pleural/microbiologia , Empiema Pleural/diagnóstico , Empiema Pleural/microbiologia
4.
Nanotechnology ; 35(50)2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39321818

RESUMO

A simple and rapid system based on Raman nanosphere (R-Sphere) immunochromatography was developed in this study for the simultaneous detection of Influenza A, B virus antigens on a single test line (T-line). Two types of R-Sphere with different characteristic Raman spectrum were used as the signal source, which were labeled with monoclonal antibodies against FluA, FluB (tracer antibodies), respectively. A mixture of antibodies containing anti-FluA monoclonal antibody and anti-FluB monoclonal antibody (capture antibody) was sprayed on a single T-line and goat anti-chicken IgY antibody was coated as a C-line, and the antigen solution with known concentration was detected by the strip of lateral flow immunochromatography based on surface-enhanced Raman spectroscopy (SERS). The T-line was scanned with a Raman spectrometer and SERS signals were collected. Simultaneous specific recognition and detection of FluA and FluB were achieved on a single T-line by analyzing the SERS signals. The findings indicated that the test system could identify FluA and FluB in a qualitative manner in just 15 minutes, with a minimum detection threshold of 0.25 ng ml-1, excellent consistency, and specificity. There was no interference with the other four respiratory pathogens, and it exhibited 8 times greater sensitivity compared to the colloidal gold test strip method. The assay system is rapid, sensitive, and does not require repetitive sample pretreatment steps and two viruses can be detected simultaneously on a single T-line by titrating one sample, which improves detection efficiency, and provide a reference for developing multiplexed detection techniques for other respiratory viruses.


Assuntos
Antígenos Virais , Vírus da Influenza A , Vírus da Influenza B , Nanosferas , Análise Espectral Raman , Análise Espectral Raman/métodos , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza A/imunologia , Antígenos Virais/análise , Antígenos Virais/imunologia , Nanosferas/química , Vírus da Influenza B/imunologia , Vírus da Influenza B/isolamento & purificação , Cromatografia de Afinidade/métodos , Cromatografia de Afinidade/instrumentação , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/química , Animais , Humanos
5.
Anal Bioanal Chem ; 416(8): 1961-1970, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38349532

RESUMO

Controlling the spread of pathogen requires an efficient and accurate diagnosis. Compared with nucleic acid and antibody detection, antigen assays are more convenient to meet clinical diagnostic needs. However, antigen detection is often difficult to achieve high sensitivity in a limited time. In this work, a novel aptasensing method was designed for the purpose of SARS-CoV-2 antigen detection, using a dumbbell padlock probe-mediated circle-to-circle amplification (C2CA) approach. A sandwich complex of antibody-antigen-aptamer is first formed on the magnetic beads. Afterwards, the signal is amplified by a C2CA reaction involving two tandem rolling circle amplifications. Without special instruments or nanomaterials, a detection limit of 575 fg/mL for S1 protein can be achieved in less than 2 h. In the case of the spike pseudovirus SARS-CoV-2 in artificial saliva, the detection limit is 272 TU/µL, which is much lower than average viral load in patients. Therefore, our method provides a timely, efficient and accurate approach for the clinical diagnosis of SARS-CoV-2. It also opens up the application of C2CA in aptamer sensing and antigen detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2
6.
Appl Microbiol Biotechnol ; 108(1): 482, 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39377803

RESUMO

Porcine epidemic diarrhea (PED), a contagious intestinal disease caused by the porcine epidemic diarrhea virus (PEDV), has caused significant economic losses to the global pig farming industry due to its rapid course and spread and its high mortality among piglets. In this study, we prepared rabbit polyclonal antibody and monoclonal antibody 6C12 against the PEDV nucleocapsid (N) protein using the conserved and antigenic PEDV N protein as an immunogen. A double-antibody sandwich quantitative enzyme-linked immunosorbent assay (DAS-qELISA) was established to detect PEDV using rabbit polyclonal antibodies as capture antibodies and horseradish peroxidase (HRP)-labeled 6C12 as the detection antibody. Using DAS-qELISA, recombinant PEDV N protein, and virus titer detection limits were approximately 0.05 ng/mL and 103.02 50% tissue culture infective dose per mL (TCID50/mL), respectively. There was no cross-reactivity with porcine reproductive and respiratory syndrome virus (PRRSV), porcine rotavirus (PoRV), porcine pseudorabies virus (PRV), porcine deltacoronavirus (PDCoV), or porcine circovirus (PCV). The reproducibility of DAS-qELISA was verified, and the coefficient of variation (CV) for intra- and inter-batch replicates was less than 10%, indicating good reproducibility. When testing anal swab samples from PEDV-infected piglets using DAS-qELISA, the coincidence rate was 92.55% with a kappa value of 0.85 when using reverse transcription-polymerase chain reaction (RT-PCR) and 94.29% with a kappa value of 0.88 when using PEDV antigen detection test strips, demonstrating the reliability of the method. These findings provide fundamental material support for both fundamental and practical studies on PEDV and offer a crucial diagnostic tool for clinical applications. KEY POINTS: • A new anti-PEDV N protein monoclonal antibody strain was prepared • Establishment of a more sensitive double antibody sandwich quantitative ELISA • DAS-qELISA was found to be useful for controlling the PEDV spread.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais , Infecções por Coronavirus , Ensaio de Imunoadsorção Enzimática , Vírus da Diarreia Epidêmica Suína , Doenças dos Suínos , Animais , Vírus da Diarreia Epidêmica Suína/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Suínos , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/virologia , Doenças dos Suínos/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/veterinária , Infecções por Coronavirus/virologia , Infecções por Coronavirus/imunologia , Anticorpos Monoclonais/imunologia , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Proteínas do Nucleocapsídeo/imunologia , Proteínas do Nucleocapsídeo/genética
7.
Biotechnol Appl Biochem ; 71(5): 1025-1031, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38689530

RESUMO

Recently, concern has been raised about the spread of human mpox virus, and the demand for rapid detection reagents for mpox virus has increased. This study aims to establish a time-resolved fluorescence immunochromatography (TRFICO) method for qualitative/quantitative detection of mpox virus. A double-antibody sandwich TRFICO method was optimized and established using mpox recombinant fusion antigen and its paired monoclonal antibody. The test performance of the method was evaluated using mpox fusion antigen and control serum, including sensitivity, linearity range, specificity, precision, and reference interval. We successfully established a TRFICO method for qualitative/quantitative detection of mpox antigen, its linearity range 0-100 ng/mL, analytical sensitivity 0.017 ng/mL, and reference intervals greater than 0.045 ng/mL. No cross-reaction was detected with various poxvirus and clinical negative controls, with good specificity. All average recoveries of the intra- and inter-batch ranged from 81.33% to 97.83%, and all CVs were below 10%. Additionally, the TRFICO strips can be stably stored at 37°C for 7 days without significant changes in the fluorescence intensity. This TRFICO method, with high sensitivity, linearity range, specificity, precision, and stability with 16-min detection time, provides a new option for qualitative/quantitative and convenient testing of mpox virus.


Assuntos
Cromatografia de Afinidade , Humanos , Cromatografia de Afinidade/métodos , Antígenos Virais/análise , Antígenos Virais/imunologia , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/química , Fluorescência , Fatores de Tempo
8.
BMC Vet Res ; 20(1): 342, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095820

RESUMO

BACKGROUND: Porcine deltacoronavirus (PDCoV) is a swine enteropathogenic coronavirus that affects young pigs, causing vomiting, acute diarrhea, dehydration, and even death. There is growing evidence that PDCoV can undergo cross-species as well as zoonotic transmissions. Due to the frequent outbreaks of this deadly virus, early detection is essential for effective prevention and control. Therefore, developing a more convenient and reliable method for PDCoV detection is the need of the hour. RESULTS: This study utilized a high-affinity monoclonal antibody as the capture antibody and a horseradish peroxidase labeled polyclonal antibody as the detection antibody to develop an enzyme-linked immunosorbent assay (DAS-ELSA) for PDCoV detection.Both antibodies target the PDCoV nucleocapsid (N) protein. The findings of this study revealed that DAS-ELISA was highly specific to PDCoV and did not cross-react with other viruses to cause swine diarrhea. The limit of detection of the virus titer using this method was 103 TCID50/mL of PDCoV particles. The results of a parallel analysis of 239 known pig samples revealed a coincidence rate of 97.07% (κ = 0.922) using DAS-ELISA and reverse transcriptase PCR (RT-PCR). The DAS-ELISA was used to measure the one-step growth curve of PDCoV in LLC-PK cells and the tissue distribution of PDCoV in infected piglets. The study found that the DAS-ELISA was comparable in accuracy to the TCID50 method while measuring the one-step growth curve. Furthermore, the tissue distribution measured by DAS-ELISA was also consistent with the qRT-PCR method. CONCLUSION: The developed DAS-ELISA method can be conveniently used for the early clinical detection of PDCoV infection in pigs, and it may also serve as an alternative method for laboratory testing of PDCoV.


Assuntos
Deltacoronavirus , Ensaio de Imunoadsorção Enzimática , Doenças dos Suínos , Animais , Ensaio de Imunoadsorção Enzimática/veterinária , Ensaio de Imunoadsorção Enzimática/métodos , Suínos , Doenças dos Suínos/virologia , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/imunologia , Deltacoronavirus/isolamento & purificação , Infecções por Coronavirus/veterinária , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/virologia , Infecções por Coronavirus/imunologia , Anticorpos Monoclonais/imunologia , Sensibilidade e Especificidade , Antígenos Virais/análise , Antígenos Virais/imunologia , Anticorpos Antivirais/sangue
9.
Proc Natl Acad Sci U S A ; 118(20)2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-33947795

RESUMO

The urgency for the development of a sensitive, specific, and rapid point-of-care diagnostic test has deepened during the ongoing COVID-19 pandemic. Here, we introduce an ultrasensitive chip-based antigen test with single protein biomarker sensitivity for the differentiated detection of both severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A antigens in nasopharyngeal swab samples at diagnostically relevant concentrations. The single-antigen assay is enabled by synthesizing a brightly fluorescent reporter probe, which is incorporated into a bead-based solid-phase extraction assay centered on an antibody sandwich protocol for the capture of target antigens. After optimization of the probe release for detection using ultraviolet light, the full assay is validated with both SARS-CoV-2 and influenza A antigens from clinical nasopharyngeal swab samples (PCR-negative spiked with target antigens). Spectrally multiplexed detection of both targets is implemented by multispot excitation on a multimode interference waveguide platform, and detection at 30 ng/mL with single-antigen sensitivity is reported.


Assuntos
Antígenos Virais/isolamento & purificação , Vírus da Influenza A/isolamento & purificação , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Diagnóstico Molecular/métodos , SARS-CoV-2/isolamento & purificação , Antígenos Virais/imunologia , Técnicas Biossensoriais , COVID-19/diagnóstico , Fluorescência , Humanos , Vírus da Influenza A/imunologia , Influenza Humana/diagnóstico , Dispositivos Lab-On-A-Chip , Limite de Detecção , Nasofaringe/virologia , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia
10.
J Med Virol ; 95(1): e28189, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36177677

RESUMO

A novel automated mariPOC SARS-CoV-2 antigen test was evaluated in a Health Care Center Laboratory among symptomatic and asymptomatic individuals seeking SARS-CoV-2 testing. According to the national testing strategy, reverse transcription polymerase chain reaction (RT-PCR) was used as a reference method. A total of 962 subjects were included in this study, 4.8% (46/962) of their samples were SARS-CoV-2 RT-PCR-positive, and 87% (40/46) of these were from symptomatics. Among the symptomatics, the overall sensitivity of the mariPOC SARS-CoV-2 test was 82.5% (33/40), though the sensitivity increased to 97.1% (33/34) in samples with a Ct < 30. The mariPOC SARS-CoV-2 test detected two of six PCR-positive samples among the asymptomatics, four cases that remained antigen test negative had Ct values between 28 and 36. The specificity of the mariPOC SARS-CoV-2 test was 100% (916/916). The evaluation showed that the mariPOC SARS-CoV-2 rapid antigen test is very sensitive and specific for the detection of individuals who most probably are contagious.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Teste para COVID-19 , Instalações de Saúde , Testes Imunológicos , Sensibilidade e Especificidade , Antígenos Virais
11.
Eur J Clin Invest ; 53(11): e14058, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37424144

RESUMO

BACKGROUND: Rapid antigen detection tests (RADTs) for SARS-CoV-2 testing offer several advantages over molecular tests, but there is little evidence supporting an ideal testing algorithm. We aimed to examine the diagnostic test accuracy (DTA) and the effectiveness of different RADT SARS-CoV-2 testing strategies. METHODS: Following PRISMA DTA guidance, we carried out a living rapid review and meta-analysis. Searches were conducted in Ovid MEDLINE® ALL, Embase and Cochrane CENTRAL electronic databases until February 2022. Results were visualized using forest plots and included in random-effects univariate meta-analyses, where eligible. RESULTS: After screening 8010 records, 18 studies were included. Only one study provided data on incidence outcomes. Seventeen studies were DTA reports with direct comparisons of RADT strategies, using RT-PCR as the reference standard. Testing settings varied, corresponding to original SARS-CoV-2 or early variants. Strategies included differences in serial testing, the individual collecting swabs and swab sample locations. Overall, specificity remained high (>98%) across strategies. Although results were heterogeneous, the sensitivity for healthcare worker-collected samples was greater than for self-collected samples. Nasal samples had comparable sensitivity when compared to paired RADTs with nasopharyngeal samples, but sensitivity was much lower for saliva samples. The limited evidence for serial testing suggested higher sensitivity if RADTs were administered every 3 days compared to less frequent testing. CONCLUSIONS: Additional high-quality research is needed to confirm our findings; all studies were judged to be at risk of bias, with significant heterogeneity in sensitivity estimates. Evaluations of testing algorithms in real-world settings are recommended, especially for transmission and incidence outcomes.

12.
Infection ; 51(5): 1285-1291, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36592297

RESUMO

PURPOSE: In addition to existing gold standard qRT-PCR methods, there is a need to develop reliable rapid tests for infection control with early notification of COVID-19 cases to enable effective outbreak management. We evaluated the validity of the three Ag-RDT kits proposed by some companies in different countries by using qRT-PCR and analyzed its results. METHODS: Each of the three Ag-RDT kits (namely A, B, and C) was tested with 90 samples, consisting of samples with Ct ≤ 25, samples with Ct > 25, and negative SARS-CoV-2 PCR samples. RESULTS: This study showed that for samples with Ct > 25, all the three kits could not detect SARS-CoV-2 Ag (0% sensitivity) but showed 100% specificity. Meanwhile, for samples with Ct ≤ 25, kit C was the best (76.7% sensitivity and 100% specificity). The PPV of the three kits was 100%, but their NPV ranged 63-84.8%. Kit C showed the best accuracy (89.9%). Some factors might influence the results of evaluation, such as variation of virus proteins and transportation-storage of the kits. CONCLUSION: The overall specificity of the three kits for all samples was high; however, all of them have not met the minimum performance requirements of ≥ 80% sensitivity for samples with Ct ≤ 25. The validation test is much necessary to be carried out by the authority in national health care to ensure the feasibility of the kit for point-of-care testing (POCT) of COVID-19. Some factors that might influence should be anticipated to increase their sensitivities and specificities.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , Testes de Diagnóstico Rápido , SARS-CoV-2 , Testes Imediatos , Surtos de Doenças , Sensibilidade e Especificidade , Teste para COVID-19
13.
Clin Chem Lab Med ; 61(3): 510-520, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36480433

RESUMO

OBJECTIVES: Various comorbidities associated with COVID-19 add up in severity of the disease and obviously prolonged the time for viral clearance. This study investigated a novel ultrasensitive MAGLUMI® SARS-CoV-2 Ag chemiluminescent immunoassay assay (MAG-CLIA) for diagnosis and monitoring the infectivity of COVID-19 patients with comorbid conditions during the pandemic of 2022 Shanghai. METHODS: Analytical performances of the MAG-CLIA were evaluated, including precision, limit of quantitation, linearity and specificity. Nasopharyngeal specimens from 232 hospitalized patients who were SARS-CoV-2 RT-qPCR positive and from 477 healthy donors were included. The longitudinal studies were performed by monitoring antigen concentrations alongside with RT-qPCR results in 14 COVID-19 comorbid participants for up to 22 days. The critical antigen concentration in determining virus infectivity was evaluated at the reference cycle threshold (Ct) of 35. RESULTS: COVID-19 patients were well-identified using an optimal threshold of 0.64 ng/L antigen concentration, with sensitivity and specificity of 95.7% (95% CI: 92.2-97.9%) and 98.3% (95% CI: 96.7-99.3%), respectively, while the Wondfo LFT exhibited those of 34.9% (95% CI: 28.8-41.4%) and 100% (95% CI: 99.23-100%), respectively. The sensitivity of MAG-CLIA remained 91.46% (95% CI: 83.14-95.8%) for the samples with Ct values between 35 and 40. Close dynamic consistence was observed between MAG-CLIA and viral load time series in the longitudinal studies. The critical value of 8.82 ng/L antigen showed adequate sensitivity and specificity in evaluating the infectivity of hospitalized convalescent patients with comorbidities. CONCLUSIONS: The MAG-CLIA SARS-CoV-2 Ag detection is an effective and alternative approach for rapid diagnosis and enables us to evaluate the infectivity of hospitalized convalescent patients with comorbidities.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Centros de Atenção Terciária , Teste para COVID-19 , China , Nasofaringe , Pandemias , Sensibilidade e Especificidade
14.
Clin Chem Lab Med ; 61(12): 2237-2247, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37377068

RESUMO

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection is an indispensable tool for epidemic surveillance in the post-pandemic era. Faced with irregular performance, a comprehensive external quality assessment (EQA) scheme was conducted by the National Center for Clinical Laboratories (NCCL) to evaluate the analytical performance and status of SARS-CoV-2 antigen tests. METHODS: The EQA panel included ten lyophilized samples containing serial 5-fold dilutions of inactivated SARS-CoV-2-positive supernatants of the Omicron BA.1 and BA.5 strains and negative samples, which were classified into "validating" samples and "educational" samples. Data were analyzed according to qualitative results for each sample. RESULTS: A total of 339 laboratories in China participated in this EQA scheme, and 378 effective results were collected. All validating samples were correctly reported by 90.56 % (307/339) of the participants and 90.21 % (341/378) of the datasets. The positive percent agreement (PPA) was >99 % for samples with concentrations of 2 × 107 copies/mL but was 92.20 % (697/756) for 4 × 106 copies/mL and 25.26 % (382/1,512) for 8 × 105 copies/mL samples. Colloidal gold was the most frequently used (84.66 %, 320/378) but showed the lowest PPAs (57.11 %, 1,462/2,560) for positive samples compared with fluorescence immunochromatography (90 %, 36/40) and latex chromatography (79.01 %, 335/424). Among 11 assays used in more than 10 clinical laboratories, ACON showed a higher sensitivity than other assays. CONCLUSIONS: The EQA study can help to validate whether it's necessary to update antigen detection assays for manufacturers and provide participants with information about the performance of assays to take the first step toward routine post-market surveillance.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Laboratórios , Pandemias , Teste para COVID-19 , Sensibilidade e Especificidade
15.
Anal Bioanal Chem ; 415(25): 6155-6164, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37596347

RESUMO

Nucleocapsid protein (NP) is one of the structural proteins of SARS-CoV-2 which is stable, well-conserved, highly immunogenic, and abundantly expressed due to the host's adaptive immune response, making it a promising antigenic biomarker for the early and rapid identification and diagnosis of SARS-CoV-2. Traditional antigen analytical methods with NP as the detection marker often have insufficient sensitivity. To achieve rapid and highly sensitive detection of NP, we constructed a novel single-molecule (digital) fluorescence-linked immunosorbent assay (FLISA) based on streptavidin-modified transparent 96-well microplates. Streptavidin was immobilized on the microplate under optimized conditions with a 15 mM carbonate buffer solution (pH 9.6) as the coating solution, biotinylated antibodies conjugated with streptavidin as capture probes, and carboxylated fluorescent microsphere-conjugated monoclonal antibodies (FMs-mAbs) as fluorescent probes. Individual sandwich immunolabeled complexes of the SARS-CoV-2 diagnostic marker NP were detected and counted though wide-field inverted fluorescence microscopy (1.1 × 1.4 mm2). FLISA had a linear detection range of 0.2 pg/mL to 200 ng/mL and a limit of detection (LOD) of 0.73 fg/mL and 8 fg/mL for NP in phosphate buffer saline and spiked nasal swab samples, respectively. The sensitivity was much higher than commercial antigen detection kits, providing wide detection prospects in future clinical diagnosis, environmental monitoring, and other fields.

16.
Appl Microbiol Biotechnol ; 107(7-8): 2413-2422, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36809389

RESUMO

Swine acute diarrhea syndrome coronavirus (SADS-CoV) is an emerging swine enteric alphacoronavirus that can cause acute diarrhea, vomiting, dehydration, and death of newborn piglets. In this study, we developed a double-antibody sandwich quantitative enzyme-linked immunosorbent assay (DAS-qELISA) for detection of SADS-CoV by using an anti-SADS-CoV N protein rabbit polyclonal antibody (PAb) and a specific monoclonal antibody (MAb) 6E8 against the SADS-CoV N protein. The PAb was used as the capture antibodies and HRP-labeled 6E8 as the detector antibody. The detection limit of the developed DAS-qELISA assay was 1 ng/mL of purified antigen and 101.08TCID50/mL of SADS-CoV, respectively. Specificity assays showed that the developed DAS-qELISA has no cross-reactivity with other swine enteric coronaviruses, such as porcine epidemic diarrhea virus (PEDV), transmissible gastroenteritis virus (TGEV), and porcine deltacoronavirus (PDCoV). Three-day-old piglets were challenged with SADS-CoV and collected anal swab samples which were screened for the presence of SADS-CoV by using DAS-qELISA and reverse transcriptase PCR (RT-PCR). The coincidence rate of the DAS-qELISA and RT-PCR was 93.93%, and the kappa value was 0.85, indicating that DAS-qELISA is a reliable method for applying antigen detection of clinical samples. KEY POINTS: • The first double-antibody sandwich quantitative enzyme-linked immunosorbent assay for detection SADS-CoV infection. • The custom ELISA is useful for controlling the SADS-CoV spread.


Assuntos
Alphacoronavirus , Infecções por Coronavirus , Vírus da Diarreia Epidêmica Suína , Doenças dos Suínos , Animais , Suínos , Coelhos , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/veterinária , Infecções por Coronavirus/epidemiologia , Ensaio de Imunoadsorção Enzimática , Doenças dos Suínos/diagnóstico
17.
J Nanobiotechnology ; 21(1): 450, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38001482

RESUMO

The outbreak of the monkeypox virus (MPXV) worldwide in 2022 highlights the need for a rapid and low-cost MPXV detection tool for effectively monitoring and controlling monkeypox disease. In this study, we developed a flexible lateral flow immunoassay (LFIA) with strong colorimetric and enhanced fluorescence dual-signal output for the rapid, on-site, and highly sensitive detection of the MPXV antigen in different scenarios. A multilayered SiO2-Au core dual-quantum dot (QD) shell nanocomposite (named SiO2-Au/DQD), which consists of a large SiO2 core (~ 200 nm), one layer of density-controlled gold nanoparticles (AuNPs, 20 nm), and thousands of small QDs, was fabricated instead of a traditional colorimetric nanotag (i.e., AuNPs) and a fluorescent nanotag (QD nanobead) to simultaneously provide good stability, strong colorimetric ability and superior fluorescence intensity. With the dual-signal output LFIA, we achieved the specific screening of the MPXV antigen (A29L) in 15 min, with detection limits of 0.5 and 0.0021 ng/mL for the colorimetric and fluorometric modes, respectively. Moreover, the colorimetric mode of SiO2-Au/DQD-LFIA exhibits the same sensitivity as the traditional AuNP- LFIA, whereas the overall sensitivity of this method on the basis of the fluorescent signal can achieve 238- and 3.3-fold improvements in sensitivity for MPXV compared with the AuNP-based LFIA and ELISA methods, respectively, indicating the powerful performance and good versatility of the dual-signal method in the point-of-care testing of the MPXV.


Assuntos
Nanopartículas Metálicas , Monkeypox virus , Ouro , Dióxido de Silício , Imunoensaio/métodos , Limite de Detecção
18.
J Infect Chemother ; 29(6): 586-591, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36849098

RESUMO

BACKGROUND: In the context of the coronavirus disease 2019 (COVID-19) pandemic, a rapid and reliable point-of-care test is an essential tool for controlling the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In particular, an immunochromatography test (ICT) that uses saliva specimens for rapid antigen detection not only reduces the risk of secondary infections but also reduces the burden on medical personnel. METHODS: The newly developed salivary antigen test kit "Inspecter Kowa® SARS-CoV-2" is an ICT to which saliva specimens can be directly applied. We evaluated its usefulness in comparison with reverse transcription quantitative PCR (RT-qPCR) and the Espline® SARS-CoV-2 Kit for the detection of SARS-CoV-2 using nasopharyngeal swab specimens. In this study, 140 patients with suspected symptomatic COVID-19 who visited our hospital were enrolled, and nasopharyngeal swab and saliva specimens were collected after they consented to participate in the study. RESULTS: Inspector Kowa SARS-CoV-2 was positive in 45 of 61 (73.8%) saliva that were positive by RT-qPCR and the Espline® SARS-CoV-2 Kit was also positive in 56 of 60 (93.3%) Np swabs that were positive by RT-qPCR. Good antigen detection was achieved by ICT with saliva and nasopharyngeal swab specimens when viral load was ≥105 copies/mL, whereas detection sensitivity was low when viral load was <105 copies/mL, especially in saliva specimens. CONCLUSION: This ICT for the detection of SARS-CoV-2 salivary antigen is an attractive tool that does not require specialized equipment and allows patients to perform the entire process from sample collection to self-diagnose and to reduce the burden on medical care during a pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Técnicas de Laboratório Clínico/métodos , Manejo de Espécimes/métodos , Nasofaringe
19.
Scand J Prim Health Care ; 41(1): 91-97, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36880344

RESUMO

OBJECTIVE: The aim was to compare rapid antigen detection test (RADT) and throat culture for group A streptococci (GAS) among patients recently treated with penicillin V for GAS pharyngotonsillitis. DESIGN AND SETTING: The study was a secondary analysis within a randomized controlled trial comparing 5 versus 10 days of penicillin V for GAS pharyngotonsillitis. Patients were recruited at 17 primary health care centres in Sweden. SUBJECTS: We included 316 patients ≥ 6 years of age, having 3-4 Centor criteria, a positive RADT and a positive throat culture for GAS at inclusion, and also having a RADT and throat culture for GAS taken at a follow-up visit within 21 days. MAIN OUTCOME MEASURES: RADT and conventional throat culture for GAS. RESULTS: This prospective study showed 91% agreement between RADT and culture at follow-up within 21 days. Only 3/316 participants had negative RADT with a positive throat culture for GAS at follow-up, and 27/316 patients with positive RADT had a negative culture for GAS. Log rank test did not reveal any difference in the decline over time of positive tests between RADT and throat culture (p = 0.24). Agreement between RADT and throat culture for GAS at the follow-up was not associated with treatment duration, number of days from inclusion until follow-up, throat symptoms at follow-up, gender, or age. CONCLUSION: RADT and culture for GAS agreed to a high extent also after recent penicillin V treatment. RADT for GAS means a low risk for missing the presence of GAS.KEY POINTSTesting for group A streptococci (GAS) before antibiotic treatment can reduce antibiotic prescription for pharyngotonsillitis. It has been proposed that rapid antigen detection tests (RADT) for group A streptococci after recent penicillin V treatment may be falsely positive due to possible persisting antigens from non-viable bacteria.The decline of the presence of GAS was similar between RADT and conventional throat culture in patients who had recently completed penicillin V treatment for GAS pharyngotonsillitisRADT for GAS is useful in identifying the presence of GAS after recent penicillin V treatment.


Assuntos
Faringite , Infecções Estreptocócicas , Humanos , Recém-Nascido , Penicilina V , Faringite/diagnóstico , Faringite/tratamento farmacológico , Faringite/microbiologia , Estudos Prospectivos , Infecções Estreptocócicas/diagnóstico , Infecções Estreptocócicas/tratamento farmacológico , Infecções Estreptocócicas/microbiologia , Streptococcus pyogenes , Antibacterianos/uso terapêutico , Atenção Primária à Saúde
20.
Parasitol Res ; 122(1): 185-194, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36385307

RESUMO

Coproantigen immunoassays (IDEXX Fecal Dx® antigen tests) were evaluated for their ability to identify Toxocara cati and Ancylostoma tubaeforme infections in cats and Uncinaria stenocephala infection in dogs. Five cats were experimentally infected with 500 embryonated eggs of T. cati, eight cats with 500 third-stage larvae (L3) of A. tubaeforme and seven dogs with 500 L3 of U. stenocephala. In addition to the three coproantigen tests, the course of infection was monitored by a combined sedimentation-flotation method with ZnSO4 as flotation medium (specific gravity: 1.28-1.30) and a modified McMaster method in case of copromicroscopically positive samples. Eggs of T. cati were first observed between 28 and 54 days post infection (dpi) in four of the five infected cats. In these four cats, positive roundworm coproantigen signals were obtained between 16 and 44 dpi. Positive coproantigen signal always preceded egg observations, but the interval varied between 6 and 30 days. Hookworm-specific positive coproantigen signals were detected in seven of the eight A. tubaeforme infected cats between 10 and 52 dpi, while consecutive egg excretion was observed in three cats between day 26 and 54 pi. Of these three, coproantigen signal preceded egg observation by 12 to 24 days. Four cats had positive coproantigen results in the absence of egg excretion, and one cat never achieved a positive result for egg or coproantigen. In six of seven U. stenocephala infected dogs, infection was confirmed by copromicroscopy between 16 and 24 dpi as well as for hookworm coproantigen between 10 and 14 dpi. Coproantigen signal was detected prior to egg observation by 2 to 14 days. No cross-reactions between the roundworm, hookworm und whipworm tests occurred in study animals. The results of this study demonstrate the ability of the coproantigen tests to detect the common roundworm and hookworm infections in cats and U. stenocephala infections in dogs as well as the ability to detect the prepatent stage of infection.


Assuntos
Doenças do Gato , Doenças do Cão , Nematoides , Infecções por Nematoides , Gatos , Animais , Cães , Ancylostoma , Toxocara , Ancylostomatoidea , Imunoensaio , Fezes , Doenças do Gato/diagnóstico , Doenças do Cão/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA