Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.950
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(23): e1239-e1311, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38718139

RESUMO

AIM: The "2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy" provides recommendations to guide clinicians in the management of patients with hypertrophic cardiomyopathy. METHODS: A comprehensive literature search was conducted from September 14, 2022, to November 22, 2022, encompassing studies, reviews, and other evidence on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through May 23, 2023, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Hypertrophic cardiomyopathy remains a common genetic heart disease reported in populations globally. Recommendations from the "2020 AHA/ACC Guideline for the Diagnosis and Treatment of Patients With Hypertrophic Cardiomyopathy" have been updated with new evidence to guide clinicians.


Assuntos
American Heart Association , Cardiologia , Cardiomiopatia Hipertrófica , Humanos , Cardiologia/normas , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/diagnóstico , Gerenciamento Clínico , Estados Unidos
2.
Eur Heart J ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864173

RESUMO

BACKGROUND AND AIMS: In patients with de novo heart failure with reduced ejection fraction (HFrEF), improvement of left ventricular ejection fraction (LVEF) is expected to occur when started on guideline-recommended medical therapy. However, improvement may not be completed within 90 days. METHODS: Patients with HFrEF and LVEF ≤ 35% prescribed a wearable cardioverter-defibrillator between 2017 and 2022 from 68 sites were enrolled, starting with a registry phase for 3 months and followed by a study phase up to 1 year. The primary endpoints were LVEF improvement > 35% between Days 90 and 180 following guideline-recommended medical therapy initiation and the percentage of target dose reached at Days 90 and 180. RESULTS: A total of 598 patients with de novo HFrEF [59 years (interquartile range 51-68), 27% female] entered the study phase. During the first 180 days, a significant increase in dosage of beta-blockers, renin-angiotensin system inhibitors, and mineralocorticoid receptor antagonists was observed (P < .001). At Day 90, 46% [95% confidence interval (CI) 41%-50%] of study phase patients had LVEF improvement > 35%; 46% (95% CI 40%-52%) of those with persistently low LVEF at Day 90 had LVEF improvement > 35% by Day 180, increasing the total rate of improvement > 35% to 68% (95% CI 63%-72%). In 392 patients followed for 360 days, improvement > 35% was observed in 77% (95% CI 72%-81%) of the patients. Until Day 90, sustained ventricular tachyarrhythmias were observed in 24 wearable cardioverter-defibrillator carriers (1.8%). After 90 days, no sustained ventricular tachyarrhythmia occurred in wearable cardioverter-defibrillator carriers. CONCLUSIONS: Continuous optimization of guideline-recommended medical therapy for at least 180 days in HFrEF is associated with additional LVEF improvement > 35%, allowing for better decision-making regarding preventive implantable cardioverter-defibrillator therapy.

3.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
4.
BMC Med ; 22(1): 130, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519982

RESUMO

BACKGROUND: Comprehensive data on patients at high risk of sudden cardiac death (SCD) in emerging countries are lacking. The aim was to deepen our understanding of the SCD phenotype and identify risk factors for death among patients at high risk of SCD in emerging countries. METHODS: Patients who met the class I indication for implantable cardioverter-defibrillator (ICD) implantation according to guideline recommendations in 17 countries and regions underrepresented in previous trials were enrolled. Countries were stratified by the WHO regional classification. Patients were or were not implanted with an ICD at their discretion. The outcomes were all-cause mortality and SCD. RESULTS: We enrolled 4222 patients, and 3889 patients were included in the analysis. The mean follow-up period was 21.6 ± 10.2 months. There were 433 (11.1%) instances of all-cause mortality and 117 (3.0%) cases of SCD. All-cause mortality was highest in primary prevention (PP) patients from Southeast Asia and secondary prevention (SP) patients from the Middle East and Africa. The SCD rates among PP and SP patients were both highest in South Asia. Multivariate Cox regression modelling demonstrated that in addition to the independent predictors identified in previous studies, both geographic region and ICD use were associated with all-cause mortality in patients with high SCD risk. Primary prophylactic ICD implantation was associated with a 36% (HR = 0.64, 95% CI 0.531-0.802, p < 0.0001) lower all-cause mortality risk and an 80% (HR = 0.20, 95% CI = 0.116-0.343, p < 0.0001) lower SCD risk. CONCLUSIONS: There was significant heterogeneity among patients with high SCD risk in emerging countries. The influences of geographic regions on patient characteristics and outcomes were significant. Improvement in increasing ICD utilization and uptake of guideline-directed medical therapy in emerging countries is urgent. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02099721.


Assuntos
Desfibriladores Implantáveis , Humanos , Fatores de Risco , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , África , Oriente Médio
5.
Magn Reson Med ; 2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38852175

RESUMO

PURPOSE: Wideband phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) enables myocardial scar imaging in implantable cardioverter defibrillators (ICD) patients, mitigating hyperintensity artifacts. To address subendocardial scar visibility challenges, a 2D breath-hold single-shot electrocardiography-triggered black-blood (BB) LGE sequence was integrated with wideband imaging, enhancing scar-blood contrast. METHODS: Wideband BB, with increased bandwidth in the inversion pulse (0.8-3.8 kHz) and T2 preparation refocusing pulses (1.6-5.0 kHz), was compared with conventional and wideband PSIR, and conventional BB, in a phantom and sheep with and without ICD, and in six patients with cardiac devices and known myocardial injury. ICD artifact extent was quantified in the phantom and specific absorption rate (SAR) was reported for each sequence. Image contrast ratios were analyzed in both phantom and animal experiments. Expert radiologists assessed image quality, artifact severity, and scar segments in patients and sheep. Additionally, histology was performed on the sheep's heart. RESULTS: In the phantom, wideband BB reduced ICD artifacts by 62% compared to conventional BB while substantially improving scar-blood contrast, but with a SAR more than 24 times that of wideband PSIR. Similarly, the animal study demonstrated a considerable increase in scar-blood contrast with wideband BB, with superior scar detection compared with wideband PSIR, the latter confirmed by histology. In alignment with the animal study, wideband BB successfully eliminated severe ICD hyperintensity artifacts in all patients, surpassing wideband PSIR in image quality and scar detection. CONCLUSION: Wideband BB may play a crucial role in imaging ICD patients, offering images with reduced ICD artifacts and enhanced scar detection.

6.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
7.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383981

RESUMO

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Sistema de Registros , Desfibriladores Implantáveis/efeitos adversos
8.
J Cardiovasc Electrophysiol ; 35(3): 592-600, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38013210

RESUMO

Continuous flow left ventricular assist devices (CF-LVADs) have been shown to reduce mortality and morbidity in patients with advanced heart failure with reduced ejection fraction. However, ventricular arrhythmias (VA) are common, are mostly secondary to underlying myocardial scar, and have a higher incidence in patients with pre-LVAD VA. Sustained VA is well tolerated in the LVAD patient but can result in implantable defibrillator (ICD) shocks, right ventricular failure, hospitalizations, and reduced quality of life. There is limited data regarding best practices for the medical management of VA as well as the role for procedural interventions in patients with uncontrolled VA and/or ICD shocks. Vast majority of CF-LVAD patients have a preexisting cardiovascular implantable electronic device (CIED) and ICD and/or cardiac resynchronization therapies are continued in many. Several questions, however, remain regarding the efficacy of ICD and CRT following CF-LVAD. Moreover, optimal CIED programming after CF-LVAD implantation. Therefore, the primary objective of this review article is to provide the most up-to-date evidence and to provide guidance on the clinical significance, pathogenesis, predictors, and management strategies for VA and ICD therapies in the CF-LVAD population. We also discuss knowledge gaps as well as areas for future research.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Desfibriladores Implantáveis/efeitos adversos , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
9.
J Cardiovasc Electrophysiol ; 35(7): 1382-1392, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38725252

RESUMO

INTRODUCTION: Reports of comparison with procedural outcomes for implantable cardioverter defibrillator (ICD) and pacemaker (PM) transvenous lead extraction (TLE) are old and limited. We sought to compare the safety, efficacy, and procedural properties of ICD and PM TLE and assess the impact of lead age. METHODS: The study cohort included all consecutive patients with ICD and PM TLE in the Cleveland Clinic Prospective TLE Registry between 2013 and 2022. Extraction success, complications, and failure employed the definitions described in the HRS 2017 TLE guidelines. RESULTS: A total of 885 ICD leads, a median implant duration of 8 (5-11) years in 810 patients, and 1352 PM leads of 7 (3-13) years in 807 patients were included. Procedural success rates in ICD patients were superior to those of PM in >20 years leads but similar in ≤20 years leads. In the PM group, the complete success rate of TLE decreased significantly according to the increase of lead age, but not in the ICD group. ICD TLE required more extraction tools compared with PM TLE but cases with older leads required non-laser sheath extraction tools in both groups. The most common injury site in major complication cases differed between ICD and PM TLE, although major complication rates showed no difference in both groups (2.7% vs. 1.6%, p = .12). CONCLUSION: The procedural success rate by TLE is greater for ICD patients than PM patients with leads >20 years old but requires more extraction tools. Common vascular complication sites and the impact of lead age on procedural outcomes and required tools differed between ICD and PM TLE.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Remoção de Dispositivo/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Ohio , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Hospitais com Alto Volume de Atendimentos , Idoso de 80 Anos ou mais , Medição de Risco
10.
J Cardiovasc Electrophysiol ; 35(3): 601-607, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38287171

RESUMO

The subcutaneous implantable cardioverter defibrillator (S-ICD) was developed as an alternative to the traditional transvenous implantable cardioverter defibrillator (TV-ICD), aiming to provide easier implantation, simplified detection algorithm of malignant ventricular arrhythmias and prevention from placing components in the cardiovascular system. The S-ICD is implanted subcutaneously or intramuscularly with the generator placed in the left midaxillary line and the lead tunneled subcutaneously in the left para-sternal region. Preimplant electrocardiogram screening is recommended to prevent implantation in patients at high risk of T wave over-sensing. Currently, the S-ICD is unsuitable for patients requiring pacing or cardiac resynchronization. Since the beginning, the S-ICD underwent extensive preclinical investigation until the first prospective multicentre trial demonstrating high efficacy and safety led to market release. While earlier studies focused on younger patients with higher ejection fraction, more recent studies showed favorable outcomes even in patients with comorbidities similar to those typically observed in patients receiving TV-ICD. The development of second and third generation devices has contributed to reduce inappropriate shocks and overcome previous limitations. The aim of this paper is to review the evidence in the literature over the past decade supporting S-ICD as a valid alternative to TV-ICD in terms of safety and efficacy, highlighting the improvements in technology, as well as outcomes.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Morte Súbita Cardíaca/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Estudos Multicêntricos como Assunto
11.
J Cardiovasc Electrophysiol ; 35(4): 794-801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38384108

RESUMO

INTRODUCTION: Several implantable cardioverter defibrillators (ICD) programming strategies are applied to minimize ICD therapy, especially unnecessary therapies from supraventricular arrhythmias (SVA). However, it remains unknown whether these optimal programming recommendations only benefit those with SVAs or have any detrimental effects from delayed therapy on those without SVAs. This study aims to assess the impact of SVA on the outcomes of ICD programming based on 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement and 2019 focused update on optimal ICD programming and testing guidelines. METHODS: Consecutive patients who underwent ICD insertion for primary prevention were classified into four groups based on SVA status and ICD programming: (1) guideline-concordant group (GC) with SVA, (2) GC without SVA, (3) nonguideline concordant group (NGC) with SVA, and (4) NGC without SVA. Cox proportional hazard models were analyzed for freedom from ICD therapies, shock, and mortality. RESULTS: Seven hundred and seventy-two patients (median age, 64 years) were enrolled. ICD therapies were the most frequent in NGC with SVA (24.0%), followed by NGC without SVA (19.9%), GC without SVA (11.6%), and GC with SVA (8.1%). Guideline concordant programming was associated with 68% ICD therapy reduction (HR 0.32, p = .007) and 67% ICD shock reduction (HR 0.33, p = .030) in SVA patients and 44% ICD therapy reduction in those without SVA (HR 0.56, p = .030). CONCLUSION: Programming ICDs in primary prevention patients based on current guidelines reduces therapy burden without increasing mortality in both SVA and non-SVA patients. A greater magnitude of reduced ICD therapy was found in those with supraventricular arrhythmias.


Assuntos
Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Arritmias Cardíacas , Morte Súbita Cardíaca/prevenção & controle
12.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
13.
Artigo em Inglês | MEDLINE | ID: mdl-38946066

RESUMO

The use of CRT-D devices with left ventricular (LV) sensing has created controversy about programming various parameters especially the left ventricular T wave protection (LVTP) designed to prevent the delivery of a pacing stimulus into the LV vulnerable period. Such devices are available from two manufacturers. This review focuses only on those provided by Biotronik. As the LVTP controls LV sensing, some investigators have advocated turning off the LVTP to prevent episodic desynchronization known a CRT pacing interrupt. However, LVTP off reduces but does not eliminate this type of desynchronization if triggering of an LV stimulus upon right ventricular sensing (RVs) is programmed on. Deactivation of the LVTP incurs loss of diagnostic data provided by CRT pacing interrupt itself. By choice, the occurrence of CRT pacing interrupt can be totally eliminated by appropriate programming of the LV upper rate interval, LVTP and triggering of an LV pacing event upon RVs. Various programmability options are available according to clinical circumstances. As a rule, clinical judgement must weigh the potential diagnostic benefit of preserving the LVTP capable of recording of episodic CRT pacing interrupt against the loss of diagnostic benefit when LVTP is programmed off (with or without triggering of an LV stimulus upon RVs).

14.
J Cardiovasc Electrophysiol ; 35(4): 821-831, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38424678

RESUMO

INTRODUCTION: Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP in comparison with conventional ATP is unknown. We aim to compare the termination rate of VT between iATP and conventional ATP in patients with implantable cardioverter-defibrillators using a unique setting of different sequential orders of both ATP algorisms. METHODS: Patients with the iATP algorithm were assigned to iATP-first and conventional ATP-first groups sequentially. In the iATP-first group, a maximum of seven iATP sequences were delivered, followed by conventional burst and ramp pacing. In contrast, in the conventional ATP-first group, two bursts and ramp pacing were initially programmed, followed by iATP sequences. We compared the success rates of VT termination in the first and secondary programmed ATP zones between the two groups. RESULTS: Fifty-eight and 56 patients were enrolled in the iATP-first and conventional ATP-first groups, and 67 and 44 VTs were analyzed in each group, respectively. At the first single ATP therapy, success rates were 64% and 70% in the iATP and conventional groups, respectively. At the end of the first iATP treatment zone, the success rate increased from 64% to 85%. Moreover, secondary iATP therapy following the failure of conventional ATPs increased the success rate from 80% to 93%. There was a significant benefit of alternative iATP for VT termination compared to secondary conventional ATP (100% vs. 33%, p = .028). CONCLUSIONS: iATP may be beneficial as a secondary therapy after failure of conventional ATP to terminate VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento , Estimulação Cardíaca Artificial/efeitos adversos , Trifosfato de Adenosina
15.
J Card Fail ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38750689

RESUMO

BACKGROUND: The Heart Failure Collaboratory (HFC) score integrates types and dosages of guideline-directed pharmacotherapies for heart failure (HF) with reduced ejection fraction (HFrEF). We examined the effects of cardioverter-defibrillator (ICD) implantation according to the modified HFC (mHFC) score in 1116 patients with nonischemic HFrEF from the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic HF on Mortality (DANISH). METHODS AND RESULTS: Patients were assigned scores for renin-angiotensin-system inhibitors, beta-blockers and mineralocorticoid receptor antagonists (0, no use; 1, < 50% of maximum dosage; 2, ≥ 50% of maximum dosage). The maximum score was 6, corresponding to ≥ 50% of maximum dosage for all therapies. The median baseline mHFC score was 4, and the median follow-up was 9.5 years. Compared with an mHFC score of 3-4, an mHFC score of 1-2 was associated with a higher rate of all-cause death (mHFC = 1-2: adjusted HR 1.67 [95% CI, 1.23-2.28]; mHFC = 3-4, reference; mHFC = 5-6: adjusted HR 1.07 [95% CI, 0.87-1.31]). ICD implantation did not reduce all-cause death compared with control (reference) (HR 0.89 [95% CI, 0.74-1.08]), regardless of mHFC score (mHFC = 1-2: HR 0.98 [95% CI, 0.56-1.71]; mHFC = 3-4: HR 0.89 [95% CI,0.66-1.20]; mHFC = 5-6: HR 0.85 [95% CI, 0.64-1.12]; Pinteraction, 0.65). Similarly, ICD implantation did not reduce cardiovascular death (HR 0.87 [95% CI, 0.70-1.09]), regardless of mHFC score (Pinteraction, 0.59). The ICD group had a lower rate of sudden cardiovascular death (HR, 0.60 [95% CI,0.40-0.92]); this association was not modified by mHFC score (Pinteraction, 0.35). CONCLUSIONS: Lower mHFC scores were associated with higher rates of all-cause death. ICD implantation did not result in an overall survival benefit in patients with nonischemic HFrEF, regardless of mHFC score.

16.
Cardiovasc Diabetol ; 23(1): 18, 2024 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184588

RESUMO

BACKGROUND: Increased risk of severe tachyarrhythmias is reported in patients with type 2 diabetes mellitus (T2DM). The aim of this study was to explore if treatment with cardiac implantable electronic device (CIED) such as implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy- pacemaker and -defibrillator (CRT-P/CRT-D) differed in patients with vs. without T2DM. A secondary aim was to identify patient characteristics indicating an increased CIED treatment. METHOD: 416 162 adult patients with T2DM from the Swedish National Diabetes Registry and 2 081 087 controls from the Swedish population, matched for age, sex and living area, were included between 1/1/1998 and 31/12/2012 and followed until 31/12/2013. They were compared regarding prevalence of ventricular tachycardia (VT) at baseline and the risk of receiving a CIED during follow-up. Multivariable Cox regression analysis was performed to estimate the risk of CIED-treatment and factors identifying patients with such risk. RESULTS: Ventricular fibrillation (VF) (0.1% vs 0.0004%) and (VT) (0.2% vs. 0.1%) were more frequent among patients with T2DM compared to controls. CIED-treatment was significantly increased in patients with T2DM both in unadjusted and adjusted analyses. HR and 95% CI, after adjustment for sex, age, marital status, income, education, country of birth, coronary artery disease and congestive heart failure, were 1.32 [1.21-1.45] for ICD, 1.74 [1.55-1.95] for CRT-P and 1.69 [1.43-1.99] for CRT-D. Blood-pressure and lipid lowering therapies were independent risk factors associated to receiving CIED, while female sex was protective. CONCLUSIONS: Although the proportion of VT/VF was low, patients with T2DM had a higher prevalence of these conditions and increased risk for treatment with CIED compared to controls. This underlines the importance of recognizing that T2DM patients have an increased need of CIED.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Diabetes Mellitus Tipo 2 , Taquicardia Ventricular , Adulto , Humanos , Feminino , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Coração , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular
17.
Infection ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38446279

RESUMO

BACKGROUND: Listeria monocytogenes is a bacterial pathogen known for causing listeriosis, a foodborne illness with a wide spectrum of clinical presentations ranging from mild gastroenteritis to severe invasive disease, particularly affecting immunocompromised individuals, pregnant women, newborns, and the elderly. Successful treatment of patients with recurring listeria episodes due to colonised foreign material is often challenging, typically requiring a combination of antimicrobial treatment and surgical removal. CASE PRESENTATION: Here, we present a particularly complex case of chronic invasive listeriosis with a total of six relapses. After extensive investigations, the patient's ICD device was identified as the focus of infection. CONCLUSION: The confirmation of relapses through cgMLST analysis highlights the persistence of Listeria monocytogenes and the potential for recurrence even after apparent resolution of symptoms in patients with foreign material. It emphasises the necessity for a comprehensive assessment to identify and mitigate the risk of relapses, thereby ensuring optimal management and outcomes.

18.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
19.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38657209

RESUMO

AIMS: Primary prevention patients with ischaemic cardiomyopathy and chronic total occlusion of an infarct-related coronary artery (CTO) are at a particularly high risk of implantable cardioverter-defibrillator (ICD) therapy occurrence. The trial was designed to evaluate the efficacy of preventive CTO-related substrate ablation strategy in ischaemic cardiomyopathy patients undergoing primary prevention ICD implantation. METHODS AND RESULTS: The PREVENTIVE VT study was a prospective, multicentre, randomized trial including ischaemic patients with ejection fraction ≤40%, no documented ventricular arrhythmias (VAs), and evidence of scar related to the coronary CTO. Patients were randomly assigned 1:1 to a preventive substrate ablation before ICD implantation or standard therapy with ICD implantation only. The primary outcome was a composite of appropriate ICD therapy or unplanned hospitalization for VAs. Secondary outcomes included the primary outcome's components, the incidence of appropriate ICD therapies, cardiac hospitalization, electrical storm, and cardiovascular (CV) mortality. Sixty patients were included in the study. During the mean follow-up of 44.7 ± 20.7 months, the primary outcome occurred in 5 (16.7%) patients undergoing preventive substrate ablation and in 13 (43.3%) patients receiving only ICD [hazard ratio (HR): 0.33; 95% confidence interval (CI): 0.12-0.94; P = 0.037]. Patients in the preventive ablation group also had fewer appropriate ICD therapies (P = 0.039) and the electrical storms (Log-rank: P = 0.01). While preventive ablation also reduced cardiac hospitalizations (P = 0.006), it had no significant impact on CV mortality (P = 0.151). CONCLUSION: Preventive ablation of the coronary CTO-related substrate in patients undergoing primary ICD implantation is associated with the reduced risk of appropriate ICD therapy or unplanned hospitalization due to VAs.


Assuntos
Ablação por Cateter , Oclusão Coronária , Desfibriladores Implantáveis , Isquemia Miocárdica , Prevenção Primária , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Oclusão Coronária/mortalidade , Oclusão Coronária/terapia , Oclusão Coronária/prevenção & controle , Oclusão Coronária/complicações , Resultado do Tratamento , Estudos Prospectivos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/mortalidade , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/terapia , Taquicardia Ventricular/mortalidade , Cardiomiopatias/mortalidade , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Infarto do Miocárdio/complicações , Doença Crônica , Fatores de Tempo
20.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38861398

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Sistema de Registros , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Incidência , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Idoso , Europa (Continente)/epidemiologia , Falha de Equipamento/estatística & dados numéricos , Estados Unidos/epidemiologia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA