Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.231
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Emerg Infect Dis ; 30(9): 1770-1778, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38985536

RESUMO

Spread of the Anopheles stephensi mosquito, an invasive malaria vector, threatens to put an additional 126 million persons per year in Africa at risk for malaria. To accelerate the early detection and rapid response to this mosquito species, confirming its presence and geographic extent is critical. However, existing molecular species assays require specialized laboratory equipment, interpretation, and sequencing confirmation. We developed and optimized a colorimetric rapid loop-mediated isothermal amplification assay for molecular An. stephensi species identification. The assay requires only a heat source and reagents and can be used with or without DNA extraction, resulting in positive color change in 30-35 minutes. We validated the assay against existing PCR techniques and found 100% specificity and analytical sensitivity down to 0.0003 ng of genomic DNA. The assay can successfully amplify single mosquito legs. Initial testing on samples from Marsabit, Kenya, illustrate its potential as an early vector detection and malaria mitigation tool.


Assuntos
Anopheles , Malária , Mosquitos Vetores , Técnicas de Amplificação de Ácido Nucleico , Animais , Anopheles/parasitologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Malária/transmissão , Malária/diagnóstico , Mosquitos Vetores/parasitologia , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Humanos , Quênia
2.
Trends Genet ; 37(4): 299-302, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33402270

RESUMO

The emergence of a mutant strain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) with an amino acid change from aspartate to a glycine residue at position 614 (D614G) has been reported and this mutant appears to be now dominant in the pandemic. Efficient detection of the SARS-CoV-2 D614G mutant by biosensing technologies is therefore crucial for the control of the pandemic.


Assuntos
Técnicas Biossensoriais , Mutação , SARS-CoV-2/genética , Glicoproteína da Espícula de Coronavírus/genética , Substituição de Aminoácidos
3.
Small ; : e2402446, 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39194585

RESUMO

The loop-mediated isothermal amplification (LAMP) is widely used in the laboratory to facilitate rapid DNA or RNA detection with a streamlined operational process, whose properties are greatly dependent on the uniformity and rise rate of temperature in the reaction chambers and the design of the primers. This paper introduces a planar micro-heater equipped with an embedded micro-temperature sensor to realize temperature tunability at a low energy cost. Moreover, a control system, based on the Wheatstone bridge and proportional, integral, and derivative (PID) control, is designed to measure and adjust the temperature of the micro-heater. The maximum temperature rise rate of the designed micro-heater is ≈8 °C s-1, and it only takes ≈60 s to reach the target temperature. Furthermore, a designed plasmid, containing the B646L gene of African Swine Fever Virus (ASFV), and a set of specific primers, are used to combine with the designed micro-heating system to implement the LAMP reaction. Finally, the lateral flow assay is used to interpret the amplification results visually. This method can achieve highly sensitive and efficient detection of ASFV within 40 min. The sensitivity of this on-chip gene detection method is 8.4 copies per reaction, holding great potential for applications in DNA and RNA amplification.

4.
Small ; 20(24): e2311764, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38506607

RESUMO

The development of novel method for drug-resistant bacteria detection is imperative. A simultaneous dual-gene Test of methicillin-resistant Staphylococcus aureus (MRSA) is developed using an Argonaute-centered portable biosensor (STAR). This is the first report concerning Argonaute-based pathogenic bacteria detection. Simply, the species-specific mecA and nuc gene are isothermally amplified using loop-mediated isothermal amplification (LAMP) technique, followed by Argonaute-based detection enabled by its programmable, guided, sequence-specific recognition and cleavage. With the strategy, the targeted nucleic acid signals gene are dexterously converted into fluorescent signals. STAR is capable of detecting the nuc gene and mecA gene simultaneously in a single reaction. The limit of detection is 10 CFU/mL with a dynamic range from 10 to 107 CFU/mL. The sample-to-result time is <65 min. This method is successfully adapted to detect clinical samples, contaminated foods, and MRSA-infected animals. This work broadens the reach of Argonaute-based biosensing and presents a novel bacterial point-of-need (PON) detection platform.


Assuntos
Técnicas Biossensoriais , Staphylococcus aureus Resistente à Meticilina , Técnicas de Amplificação de Ácido Nucleico , Staphylococcus aureus Resistente à Meticilina/genética , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Técnicas Biossensoriais/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Proteínas Argonautas/metabolismo , Proteínas Argonautas/genética , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Proteínas de Ligação às Penicilinas/genética , Animais , Nuclease do Micrococo/metabolismo , Nuclease do Micrococo/genética
5.
BMC Microbiol ; 24(1): 68, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38413863

RESUMO

OBJECTIVES: In the current study, for the first time, we reported a novel HCV molecular diagnostic approach termed reverse transcription loop-mediated isothermal amplification integrated with a gold nanoparticles-based lateral flow biosensor (RT-LAMP-AuNPs-LFB), which we developed for rapid, sensitive, specific, simple, and visual identification of HCV. METHODS: A set of LAMP primer was designed according to 5'untranslated region (5'UTR) gene from the major HCV genotypes 1b, 2a, 3b, 6a, and 3a, which are prevalent in China. The HCV-RT-LAMP-AuNPs-LFB assay conditions, including HCV-RT-LAMP reaction temperature and time were optimized. The sensitivity, specificity, and selectivity of our assay were evaluated in the current study. The feasibility of HCV-RT-LAMP-AuNPs-LFB was confirmed through clinical serum samples from patients with suspected HCV infections. RESULTS: An unique set of HCV-RT-LAMP primers were successfully designed targeting on the 5'UTR gene. The optimal detection process, including crude nucleic acid extraction (approximately 5 min), RT-LAMP reaction (67℃, 30 min), and visual interpretation of AuNPs-LFB results (~ 2 min), could be performed within 40 min without specific instruments. The limit of detection was determined to be 20 copies per test. The HCV-RT-LAMP-AuNPs-LFB assay exhibited high specificity and anti-interference. CONCLUSIONS: These preliminary results confirmed that the HCV-RT-LAMP-AuNPs-LFB assay is a sensitive, specific, rapid, visual, and cost-saving assay for identification of HCV. This diagnostic approach has great potential value for point-of-care (POC) diagnostic of HCV, especially in resource-challenged regions.


Assuntos
Técnicas Biossensoriais , Hepatite C , Nanopartículas Metálicas , Humanos , Hepacivirus/genética , Ouro , Sensibilidade e Especificidade , Regiões 5' não Traduzidas , Hepatite C/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas Biossensoriais/métodos
6.
J Med Virol ; 96(6): e29721, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899377

RESUMO

Globally, hepatitis B virus (HBV) affects over 250 million people, whereas hepatitis C virus (HCV) affects approximately 70 million people, posing major public health challenges. Despite the availability of vaccines and treatments, a lack of comprehensive diagnostic coverage has left many cases undiagnosed and untreated. To address the need for sensitive, specific, and accessible diagnostics, this study introduced a multiplex loop-mediated isothermal amplification assay with lateral flow detection for simultaneous HBV and HCV testing. This assay achieved exceptional sensitivity and was capable of detecting HBV and HCV concurrently in a single tube and on a single strip within 25 min, achieving the required clinical sensitivity (10 and 103 genomic copies/reaction for HBV and HCV, respectively). The method was validated in clinical samples of various viral genotypes, achieving an equivalent limit of detection. Additionally, a custom portable heating device was developed for field use. The assay developed here, capable of direct viral detection on the strip, shows promise in supplanting current methods that solely identify antibodies and necessitate additional qPCR for viral activity assessment. This economical and rapid assay aligns with point-of-care testing needs, offering significant advancements in enhancing viral hepatitis diagnostics in settings with limited resources.


Assuntos
Hepacivirus , Vírus da Hepatite B , Hepatite B , Hepatite C , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico/métodos , Humanos , Hepatite B/diagnóstico , Hepatite B/virologia , Vírus da Hepatite B/genética , Vírus da Hepatite B/isolamento & purificação , Hepacivirus/genética , Hepacivirus/isolamento & purificação , Hepatite C/diagnóstico , Hepatite C/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Genótipo
7.
Anal Biochem ; 688: 115480, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38331373

RESUMO

Isothermal nucleic acid amplification methods have many advantages for use at the point of care. However, there is a lack of multiplexed isothermal amplification tests to detect multiple targets in a single reaction, which would be valuable for many diseases, such as infection with high-risk human papillomavirus (hrHPV). In this study, we developed a multiplexed loop-mediated isothermal amplification (LAMP) reaction to detect the three most common hrHPV types that cause cervical cancer (HPV16, HPV18, and HPV45) and a cellular control for sample adequacy. First, we characterized the assay limit of detection (LOD) in a real-time reaction with fluorescence readout; after 30 min of amplification the LOD was 100, 10, and 10 copies/reaction of HPV16, HPV18, and HPV45, respectively, and 0.1 ng/reaction of human genomic DNA (gDNA). Next, we implemented the assay on lateral flow strips, and the LOD was maintained for HPV16 and HPV18, but increased to 100 copies/reaction for HPV45 and to 1 ng/reaction for gDNA. Lastly, we used the LAMP test to evaluate total nucleic acid extracted from 38 clinical samples; compared to qPCR, the LAMP test had 89% sensitivity and 95% specificity. When integrated with sample preparation, this multiplexed LAMP assay could be useful for point-of-care testing.


Assuntos
Papillomavirus Humano 18 , Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Papillomavirus Humano , Sensibilidade e Especificidade , Infecções por Papillomavirus/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Papillomavirus Humano 16/genética , Papillomaviridae/genética , DNA Viral/genética
8.
Anal Biochem ; 684: 115376, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37924966

RESUMO

Nucleic acids amplification is a widely used technique utilized for different manipulations with DNA and RNA. Although, polymerase chain reaction (PCR) remains the most popular amplification method, isothermal approaches are gained more attention last decades. Among these, loop-mediated isothermal amplification (LAMP) became an excellent alternative to PCR. LAMP requires an increased number of primers and, therefore, is considered a highly specific amplification reaction compared to PCR. LAMP primers design is still a non-trivial task, and all niceties should be taken into account during their selection. Here, we report on a new program called LAMPrimers iQ destined for high-quality LAMP primers design. LAMPrimers iQ is based on an original algorithm considering rigorous criteria for primers selection. Unlike alternative programs, LAMPrimers iQ can process long DNA or RNA sequences, and completely avoid primers that can form homo- and heterodimers. The quality of the primers designed was checked using SARS-CoV-2 coronavirus RNA as a model target. It was shown that primers selected with LAMPrimers iQ provide higher specificity and reliable detection of viral RNA compared to those obtained by alternative programs. The program is available at https://github.com/Restily/LAMPrimers-iQ.


Assuntos
DNA , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico/métodos , Software , RNA
9.
Anal Biochem ; 688: 115481, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38360170

RESUMO

Colorimetric assays are some of the most convenient detection methods, creating discoloration in solutions that is visible to the naked eye. However, colorimetric reactions have some limitations regarding the variability in the color perception of individuals caused by factors such as color blindness, experience, and gender. Semi-quantitative chromatic analysis has been used as an alternative method to differentiate between two colors and accurately interpret the results from a numerical value, with high confidence. Therefore, we developed and determined the optimal model between Red-Green-Blue (RGB) and Commission Internationale de l'Eclairage (CIE) Lab color spaces to establish a semi-quantitative colorimetric assay via image analysis by the ImageJ program for loop-mediated isothermal amplification (LAMP), using the dyes malachite green and phenol red. The semi-quantitative colorimetric assays using the color distance values of the CIELab color space (ΔEab) were more suitable than those using the RGB color space (ΔERGB) for chromatic differentiation between positive and negative reactions in both indicator dyes, demonstrating the feasibility of this assay to be applied in the detection of a wide range of pathogens and infectious diseases.


Assuntos
Colorimetria , Técnicas de Amplificação de Ácido Nucleico , Humanos , Colorimetria/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Corantes , Técnicas de Diagnóstico Molecular
10.
Anal Biochem ; 694: 115615, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39002745

RESUMO

With the rise in extreme weather due to global warming, coupled with globalization facilitating the spread of infectious diseases, there's a pressing need for portable testing platforms offering simplicity, low cost, and remote transmission, particularly beneficial in resource-limited and non-urban areas. We have developed a portable device using loop-mediated isothermal amplification (LAMP) with spectrometric detection to identify Salmonella Typhimurium DNA. The device utilizes the LinkIt 7697 microcontroller and a microspectrometer to capture and transmit spectral signals in real-time, allowing for improved monitoring and analysis of the reaction progress. We built a hand-held box containing a microspectrometer, thermoelectric cooler, ultraviolet LED, disposable reaction tube, and homemade thermal module, all powered by rechargeable batteries. Additionally, we conducted thorough experiments to ensure temperature accuracy within 1 °C under thermal control, developed a heating module with a LinkIt 7697 IoT development board to heat the DNA mixture to the reaction temperature within 3 min, and integrated foam insulation and a 3D-printed frame to enhance the device's thermal stability. We successfully demonstrated the amplification of Salmonella Typhimurium DNA with an impressive sensitivity of 2.83 × 10-4 ng/µL. A remote webpage interface allows for monitoring the temperature and fluorescence during the LAMP process, improving usability. This portable LAMP device with real-time detection offers a cost-effective solution for detecting Salmonella Typhimurium in food products. Its unique design and capabilities make it a promising tool for ensuring food safety.


Assuntos
DNA Bacteriano , Técnicas de Amplificação de Ácido Nucleico , Salmonella typhimurium , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Salmonella typhimurium/isolamento & purificação , Salmonella typhimurium/genética , DNA Bacteriano/análise , DNA Bacteriano/genética , Microbiologia de Alimentos , Técnicas de Diagnóstico Molecular
11.
Med Mycol ; 62(2)2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38327232

RESUMO

Mucormycosis is a rare disease with scarce diagnostic methods for early intervention. Available strategies employing direct microscopy using calcofluor white-KOH, culture, radiologic, and histopathologic testing often are time-intensive and demand intricate protocols. Nucleic Acid Amplification Test holds promise due to its high sensitivity combined with rapid detection. Loop-mediated isothermal amplification (LAMP) based detection offers an ultrasensitive technique that does not require complicated thermocyclers like in polymerase chain reaction, offering a straightforward means for improving diagnoses as a near-point-of-care test. The study introduces a novel magnetic nanoparticle-based LAMP assay for carryover contaminant capture to reduce false positives. Solving the main drawback of LAMP-based diagnosis techniques. The assay targets the cotH gene, which is invariably specific to Mucorales. The assay was tested with various species of Mucorales, and the limit of detections for Rhizopus microsporus, Lichtheimia corymbifera, Rhizopus arrhizus, Rhizopus homothallicus, and Cunninghamella bertholletiae were 1 fg, 1 fg, 0.1 pg, 0.1 pg, and 0.01 ng, respectively. This was followed by a clinical blindfolded study using whole blood and urine samples from 30 patients diagnosed with Mucormycosis. The assay has a high degree of repeatability and had an overall sensitivity of > 83%. Early Mucormycosis detection is crucial, as current lab tests from blood and urine lack sensitivity and take days for confirmation despite rapid progression and severe complications. Our developed technique enables the confirmation of Mucormycosis infection in < 45 min, focusing specifically on the RT-LAMP process. Consequently, this research offers a viable technique for quickly identifying Mucormycosis from isolated DNA of blood and urine samples instead of invasive tissue samples.


Mucormycosis is a challenging disease to diagnose early. This study introduces a sensitive and rapid diagnostic approach using Loop-mediated isothermal amplification technology. Testing blood and urine samples from 30 patients revealed promising sensitivity and repeatability, indicating its potential for non-invasive diagnosis.


Assuntos
Nanopartículas de Magnetita , Mucorales , Mucormicose , Humanos , Mucormicose/diagnóstico , Mucormicose/veterinária , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/veterinária , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/veterinária , Mucorales/genética
12.
Int J Legal Med ; 138(3): 751-756, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38091067

RESUMO

Analyzing all biological evidence at a crime scene presents serious time, budget, and labor constraints. Therefore, selecting valid evidence is crucial for efficient screening. The ABO blood group is a marker that can serve as valid evidence for identifying investigative leads in criminal case. Conventional identification of ABO blood groups using serological methods has only been for blood and is difficult to apply to other body fluids. ABO genotyping was conducted by analyzing single nucleotide polymorphisms (SNP) representative of each blood group. However, this method is time-consuming, expensive, and requires sophisticated instruments. In this study, we developed rapid ABO genotyping method using loop-mediated isothermal amplification (LAMP) and multiplex real-time polymerase chain reaction (PCR). Three SNP sites in the ABO gene (nt 261, 526, and 803) were selected to classify the ABO genotypes. For the specificity test, we performed sequencing of 60 saliva samples to confirm that the genotyping. We conducted experiments to apply ABO genotyping using two amplification methods to mock forensic sample using cotton swab and filter paper. As a result, using LAMP, we successfully identified six ABO genotypes within 30 min at a constant temperature (65 ℃). Moreover, by using multiple real-time PCR, it was possible to detect not only the major group but also the subgroup of the ABO genotype (ex. cis-AB). The amplification results using the new methods were in concordance with the sequencing results. Therefore, these ABO genotyping methods are expected to select valid evidence successfully and efficiently at the crime scene.


Assuntos
Técnicas de Genotipagem , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Genótipo , Técnicas de Genotipagem/métodos , Sistema ABO de Grupos Sanguíneos/genética , Sensibilidade e Especificidade
13.
Anal Bioanal Chem ; 416(2): 363-372, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37935845

RESUMO

A recent outbreak of porcine circovirus-like virus (PCLV), a virus that may be associated with porcine diarrhea, has been reported in swine herds in China. The virus is spreading rapidly, causing huge economic losses to the swine farming industry. To achieve the rapid, inexpensive, and sensitive detection of PCLV, we combined loop-mediated isothermal amplification (LAMP) and the CRISPR/Cas12a system, whose fluorescence intensity readout can detect PCLV ORF4 gene levels as low as 10 copies. To overcome the need for sophisticated equipment, lateral flow strip reading technology was introduced for the first time in a LAMP-Cas12a-based system to detect PCLV. The lateral flow strip (LFS) results were readout by the naked eye, and the method was highly sensitive with a detection limit of 10 copies, with a detection time of about 60 min. In addition, the method is highly specific and has no cross-reactivity with other related viruses. In conclusion, LAMP-CRISPR/Cas12a-based assays have the advantages of rapidity, accuracy, portability, low cost, and visualization of the results. They therefore have great potential, especially for areas where specialized equipment is lacking, and can expect to be an ideal method for early diagnosis and on-site detection of PCLV.


Assuntos
Circovirus , Doenças dos Suínos , Vírus , Suínos , Animais , Circovirus/genética , Sistemas CRISPR-Cas , Doenças dos Suínos/diagnóstico , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico/métodos
14.
Appl Microbiol Biotechnol ; 108(1): 91, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38212962

RESUMO

Epstein-Barr virus (EBV) is a ubiquitous gamma herpesvirus that maintains a lifelong latent association with B lymphocytes. Here, a rapid and reliable diagnosis platform for detecting EBV infection, employing loop-mediated isothermal amplification (LAMP) combined with a gold nanoparticles-based lateral flow biosensors (AuNPs-LFB) (termed LAMP Amplification Mediated AuNPs-LFB Detection, LAMAD), was developed in the current study. A set of specific LAMP primers targeting the Epstein-Barr nuclear antigen (EBNA) leader protein (EBNA-LP) gene was designed and synthesized. Subsequently, these templates extracted from various pathogens and whole blood samples were used to optimize and evaluate the EBV-LAMAD assay. As a result, the limit of detection (LoD) of the EBV-LAMAD assay was 45 copies/reaction. The EBV-LAMAD assay can detect all representative EBV pathogens used in the study, and of note, no cross-reactions were observed with other non-EBV organisms. Moreover, the whole workflow of the EBV-LAMAD assay can be completed within 70 min, including rapid EBV template preparation, EBV-LAMP amplification, and AuNPs-LFB-mediated detection. Taken together, the EBV-LAMAD assay targeting the EBNA-LP gene is a rapid, simplified, sensitive, reliable, and easy-to-use detection protocol that can be used as a competitive potential diagnostic/screening tool for EBV infection in clinical settings, especially in basic laboratories in resource-limited regions. KEY POINTS: • A novel, simplified, and easy-to-use AuNPs-LFB biosensor was designed and prepared. • LAMP combined with an AuNPs-LFB targeting the novel EBNA-LP gene was established. • EBV-LAMAD is a rapid, sensitive, and reliable detection protocol for EBV infection.


Assuntos
Técnicas Biossensoriais , Infecções por Vírus Epstein-Barr , Nanopartículas Metálicas , Técnicas de Diagnóstico Molecular , Humanos , Herpesvirus Humano 4/genética , Infecções por Vírus Epstein-Barr/diagnóstico , Ouro , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas Biossensoriais/métodos , Sensibilidade e Especificidade
15.
Appl Microbiol Biotechnol ; 108(1): 414, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985204

RESUMO

Airborne animal viral pathogens can rapidly spread and become a global threat, resulting in substantial socioeconomic and health consequences. To prevent and control potential epidemic outbreaks, accurate, fast, and affordable point-of-care (POC) tests are essential. As a proof-of-concept, we have developed a molecular system based on the loop-mediated isothermal amplification (LAMP) technique for avian metapneumovirus (aMPV) detection, an airborne communicable agent mainly infecting turkeys and chickens. For this purpose, a colorimetric system was obtained by coupling the LAMP technique with specific DNA-functionalized AuNPs (gold nanoparticles). The system was validated using 50 different samples (pharyngeal swabs and tracheal tissue) collected from aMPV-infected and non-infected chickens and turkeys. Viral detection can be achieved in about 60 min with the naked eye, with 100% specificity and 87.88% sensitivity for aMPV. In summary, this novel molecular detection system allows suitable virus testing in the field, with accuracy and limit of detection (LOD) values highly close to qRT-PCR-based diagnosis. Furthermore, this system can be easily scalable to a platform for the detection of other viruses, addressing the current gap in the availability of POC tests for viral detection in poultry farming. KEY POINTS: •aMPV diagnosis using RT-LAMP is achieved with high sensitivity and specificity. •Fifty field samples have been visualized using DNA-nanoprobe validation. •The developed system is a reliable, fast, and cost-effective option for POCT.


Assuntos
Galinhas , Ouro , Metapneumovirus , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Infecções por Paramyxoviridae , Doenças das Aves Domésticas , Sensibilidade e Especificidade , Metapneumovirus/genética , Metapneumovirus/isolamento & purificação , Animais , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/economia , Galinhas/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/economia , Infecções por Paramyxoviridae/diagnóstico , Infecções por Paramyxoviridae/veterinária , Infecções por Paramyxoviridae/virologia , Doenças das Aves Domésticas/virologia , Doenças das Aves Domésticas/diagnóstico , Ouro/química , Perus , Nanopartículas Metálicas/química , Limite de Detecção , Colorimetria/métodos , DNA Viral/genética
16.
Phytopathology ; 114(6): 1237-1243, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38349769

RESUMO

Downy mildew of onion caused by a soil-inhabiting water mold, Peronospora destructor, is one of the most devastating diseases that can destroy entire onion fields in a matter of days. In this study, we developed a loop-mediated isothermal amplification (LAMP) assay that allows for rapid detection of P. destructor by visual inspection. The internal transcribed spacer 2 region of P. destructor was used to design primer sets for LAMP reactions. The optimal temperature and incubation time were determined for the most efficient primer set. In the optimized condition, the LAMP assay exhibited at least 100 times more sensitivity than conventional PCR, detecting femtogram levels of P. destructor genomic DNA (gDNA). Detection of the pathogen from a small number of spores without gDNA extraction further confirmed the high sensitivity of the assay. For specificity, the LAMP assay was negative for gDNA of other fungal pathogens that cause various diseases on onion and oomycetes, whereas the assay was positive for gDNA extracted from onion tissues showing the typical downy mildew symptoms. Finally, we examined the efficacy of the LAMP assay in detection of P. destructor in soils. Soils collected from onion fields that had been contaminated with P. destructor were solarized for 60 days. Whereas the LAMP assay was negative for the solarized soils, we were able to detect P. destructor that oversummers in fields. The LAMP assay developed in this study enables rapid detection and diagnosis of downy mildew of onion in infected tissues and in soil.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Cebolas , Peronospora , Doenças das Plantas , Microbiologia do Solo , Cebolas/microbiologia , Doenças das Plantas/microbiologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Peronospora/genética , Peronospora/isolamento & purificação , Sensibilidade e Especificidade , DNA Fúngico/genética , Solo , Técnicas de Diagnóstico Molecular
17.
Parasitol Res ; 123(2): 126, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38326433

RESUMO

Colorimetric detection can be applied to differentiate between positive and negative conditions. It can be coupled with loop-mediated isothermal amplification to diagnose rumen fluke or paramphistome infection, also called colorimetric PAR-LAMP. This study conducted LAMP using three candidate indicator dyes, namely malachite green (MLG), methyl green (MTG), and neutral red (NTR), and the results were observed by the naked eye. The dye concentration was optimized to obtain the most pronounced positive-negative result discrimination. Subsequently, we conducted target sensitivity tests using the DNA of Fischoederius elongatus at different concentrations. To validate the detection accuracy, the result was confirmed by gel electrophoresis. The sensitivity test presented the lowest detectable DNA concentration or limit of detection (LOD), with 1 pg for MLG, 0.5 ng for MTG, and 50 pg for NTR. Different LODs revealed inhibition of LAMP reaction and reduced efficiency of result presentation for colorimetric-based detection, particularly NTR and MTG. For MLG-LAMP, we observed no cross-reaction of non-target DNA and improved reaction with the DNA of Fischoederius cobboldi and Calicophoron sp., with multi-detection. In addition, naked eye observation and agarose gel electrophoresis (AGE) evaluation of the MLG-LAMP results showed a moderate and strong agreement with LAMP-AGE and microscopic examinations. Based on our results, colorimetric PAR-LAMP is a rapid, comfortable, and point-of-care procedure for the diagnosis of paramphistome infection.


Assuntos
Colorimetria , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Corantes de Rosanilina , Animais , Sensibilidade e Especificidade , Colorimetria/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , DNA
18.
Luminescence ; 39(6): e4795, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899381

RESUMO

We aimed to develop a novel diagnostic method called multiplex fluorescence of loop primer upon self-dequenching loop-mediated isothermal amplification (mFLOS-LAMP) for the rapid detection of Mycobacterium tuberculosis complex (MTBC). A set of specific primers was designed to target the detection of IS1081 and IS6110 genes, which are insertion sequences within the MTBC. The 110 sputum specimens collected were assessed using the established mFLOS-LAMP method, multiplex polymerase chain reaction, Xpert MTB/RIF, and smear microscopy. The optimal reaction temperature and duration for mFLOS-LAMP were determined to be 65°C and 30 min, respectively, by optimizing the entire system. The detection sensitivity of mFLOS-LAMP was 6.0 × 101 CFU/mL, by Bacillus Calmette-Guerin, and the mFLOS-LAMP sensitivity of M. tuberculosis H37Rv genomic DNA was 500 fg, and the specificity was 100%. The sensitivity of mFLOS-LAMP was 94.2% and the specificity was 96.6%, when Xpert MTB/RIF was used as the reference method. There was no statistically significant difference in their detection rate (χ2 = 0, P = 1.000), and the consistency was good (kappa = 0.909, P < 0.001). The receiver operating characteristic analysis yielded the maximum area under the curve of 0.954. The mFLOS-LAMP method demonstrated high sensitivity and specificity, allowing for swift and accurate detection of MTBC.


Assuntos
Corantes Fluorescentes , Mycobacterium tuberculosis , Técnicas de Amplificação de Ácido Nucleico , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/isolamento & purificação , Corantes Fluorescentes/química , Humanos , DNA Bacteriano , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular
19.
Plant Dis ; : PDIS08231507RE, 2024 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-38422453

RESUMO

Bacterial blight caused by Xanthomonas phaseoli pv. manihotis (Xpm) is considered the main bacterial disease that affects cassava, causing significant losses when not properly managed. In the present study, a fast, sensitive, and easy-to-apply method to detect Xpm via colorimetric loop-mediated isothermal amplification (LAMP) was developed. To ensure the use of a unique-to-the-target pathovar core region for primer design, 74 complete genomic sequences of Xpm together with different bacterial species and pathovars were used for comparative genomics. A total of 42 unique genes were used to design 27 LAMP primer sets, from which nine primers were synthesized, and only one (Xpm_Lp1 primer set) showed sufficient efficiency in preliminary tests. The sensitivity, assessed by a serial dilution of the type strain (IBSBF 278) DNA, yielded high sensitivity, detecting up to 100 fg. The LAMP primers showed high specificity, did not cross-react with other bacterial species or other pathovars tested, and amplified only the Xpm isolates. Tests confirmed the high efficiency of the protocol using infected or inoculated macerated cassava leaves without the need for additional sample treatment. The LAMP test developed in this study was able to detect Xpm in a fast, simple, and sensitive way, and it can be used to monitor the disease under laboratory and field conditions.

20.
Plant Dis ; 108(1): 35-40, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37528342

RESUMO

The pathogen Colletotrichum siamense causes tea anthracnose, resulting in economic losses to the Chinese tea industry. To effectively diagnose this pathogen in the field, we developed a loop-mediated isothermal amplification (LAMP) method using highly specific primers with a sensitivity of 1 pg/µl designed for amplifying the CAL gene, which was 10 times higher than that of conventional PCR. Additionally, to improve the method for obtaining DNA samples required for on-site diagnosis, we used the filter-disc DNA extraction method, which does not require special instruments and can be completed in a few minutes, and found that it effectively meets the requirements for the LAMP reaction. Finally, we combined LAMP with a filter-disc DNA extraction method (FDE-LAMP) to diagnose different degrees of disease in inoculated samples and 20 samples from the field. The results showed that the procedure had sufficient sensitivity for pathogen detection. Therefore, the FDE-LAMP procedure could greatly contribute to managing and preventing tea anthracnose in the field.


Assuntos
Colletotrichum , DNA , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Chá , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA