Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 197
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(5): e2305300, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37735143

RESUMO

Caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), coronavirus disease 2019 (COVID-19) has shown extensive lung manifestations in vulnerable individuals, putting lung imaging and monitoring at the forefront of early detection and treatment. Magnetic particle imaging (MPI) is an imaging modality, which can bring excellent contrast, sensitivity, and signal-to-noise ratios to lung imaging for the development of new theranostic approaches for respiratory diseases. Advances in MPI tracers would offer additional improvements and increase the potential for clinical translation of MPI. Here, a high-performance nanotracer based on shape anisotropy of magnetic nanoparticles is developed and its use in MPI imaging of the lung is demonstrated. Shape anisotropy proves to be a critical parameter for increasing signal intensity and resolution and exceeding those properties of conventional spherical nanoparticles. The 0D nanoparticles exhibit a 2-fold increase, while the 1D nanorods have a > 5-fold increase in signal intensity when compared to VivoTrax. Newly designed 1D nanorods displayed high signal intensities and excellent resolution in lung images. A spatiotemporal lung imaging study in mice revealed that this tracer offers new opportunities for monitoring disease and guiding intervention.


Assuntos
Nanopartículas de Magnetita , Nanopartículas , Camundongos , Animais , Anisotropia , Diagnóstico por Imagem/métodos , Magnetismo , Fenômenos Magnéticos , Imageamento por Ressonância Magnética
2.
Magn Reson Med ; 91(6): 2612-2620, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38247037

RESUMO

PURPOSE: Measure the changes in relative lung water density (rLWD), lung volume, and total lung water content as a function of time after supine body positioning. METHODS: An efficient ultrashort-TE pulse sequence with a yarnball k-space trajectory was used to measure water density-weighted lung images for 25 min following supine body positioning (free breathing, 74-s acquisitions, 3D images at functional residual capacity, 18 time points) in 9 healthy volunteers. Global and regional (10 chest-to-back positions) rLWD, lung volume, and total lung water volume were measured in all subjects at all time points. Volume changes were validated with a nitrogen washout study in 3 participants. RESULTS: Global rLWD increased significantly (p = 0.001) from 31.8 ± 5.5% to 34.8 ± 6.8%, while lung volumes decreased significantly (p < 0.001) from 2390 ± 620 mL to 2130 ± 630 mL over the same 25-min interval. Total lung water volume decreased slightly from 730 ± 125 mL to 706 ± 126 mL (p = 0.028). There was a significant chest-to-back gradient in rLWD (20.7 ± 4.6% to 39.9 ± 6.1%) at all time points with absolute increases of 1.8 ± 1.2% at the chest and 5.4 ± 1.9% at the back. Nitrogen washout studies yielded a similar reduction in lung volume (12.5 ± 0.9%) and time course following supine positioning. CONCLUSION: Lung volumes during tidal breathing decrease significantly over tens of minutes following supine body positioning, with corresponding increases in lung water density (9.2 ± 4.4% relative increase). The total volume of lung water is slightly reduced over this interval (3.3 ± 4.0% relative change). Evaluation of rLWD should take time after supine positioning, and more generally, all sources of lung volume changes should be taken into consideration to avoid significant bias.


Assuntos
Pulmão , Posicionamento do Paciente , Humanos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Respiração , Nitrogênio , Decúbito Dorsal
3.
Magn Reson Med ; 92(3): 967-981, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38297511

RESUMO

PURPOSE: Hyperpolarized xenon MRI suffers from heterogeneous coil bias and magnetization decay that obscure pulmonary abnormalities. Non-physiological signal variability can be mitigated by measuring and mapping the nominal flip angle, and by rescaling the images to correct for signal bias and decay. While flip angle maps can be calculated from sequentially acquired images, scan time and breath-hold duration are doubled. Here, we exploit the low-frequency oversampling of 2D-spiral and keyhole reconstruction to measure flip angle maps from a single acquisition. METHODS: Flip angle maps were calculated from two images generated from a single dataset using keyhole reconstructions and a Bloch-equation-based model suitable for hyperpolarized substances. Artifacts resulting from acquisition and reconstruction schemes (e.g., keyhole reconstruction radius, slice-selection profile, spiral-ordering, and oversampling) were assessed using point-spread functions. Simulated flip angle maps generated using keyhole reconstruction were compared against the paired-image approach using RMS error (RMSE). Finally, feasibility was demonstrated for in vivo xenon ventilation imaging. RESULTS: Simulations demonstrated accurate flip angle maps and B1-inhomogeneity correction can be generated with only 1.25-fold central-oversampling and keyhole reconstruction radius = 5% (RMSE = 0.460°). These settings also generated accurate flip angle maps in a healthy control (RSME = 0.337°) and a person with cystic fibrosis (RMSE = 0.404°) in as little as 3.3 s. CONCLUSION: Regional lung ventilation images with reduced impact of B1-inhomogeneity can be acquired rapidly by combining 2D-spiral acquisition, Bloch-equation-based modeling, and keyhole reconstruction. This approach will be especially useful for breath-hold studies where short scan durations are necessary, such as dynamic imaging and applications in children or people with severely compromised respiratory function.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Pulmão , Imageamento por Ressonância Magnética , Isótopos de Xenônio , Humanos , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio/química , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Simulação por Computador , Algoritmos , Masculino , Feminino , Imagens de Fantasmas , Adulto , Suspensão da Respiração , Fibrose Cística/diagnóstico por imagem
4.
Am J Physiol Lung Cell Mol Physiol ; 324(3): L358-L372, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36719077

RESUMO

Mechanical forces affect the alveolar shape, depending on location and tissue composition, and vary during the respiratory cycle. This study performs alveolar morphomics in different lobes of human lungs using models generated from three-dimensional (3-D) micro-computed tomography (microCT) images. Cylindrical tissue samples (1.6 cm × 2 cm) were extracted from two nontransplantable donor lungs (one ex-smoker and one smoker, 3 samples per subject) that were air-inflated and frozen solid in liquid nitrogen vapor. Samples were scanned with microCT (11 µm/voxel). Within representative cubic regions of interest (5.5 mm edge length), alveoli were segmented to produce corresponding 3-D models from which quantitative data were obtained. The surface of segmented alveoli (n_alv_total = 23,587) was divided into individual planar surfaces (facets) and angles between facet normals were calculated. Moreover, the number of neighboring alveoli was estimated for every alveolus. In this study, we examined intraindividual differences in alveolar morphology, which were reproducible in the lungs of two subjects. The main aspects are higher mean alveolar volumes (v_alv: 6.64 × 106 and 6.63 × 106 µm3 vs. 5.78 × 106 and 6.29 × 106 µm3) and surface sizes (s_alv: 0.19 and 0.18 mm2 vs. 0.17 mm2 in both lower lobes) in both upper lung lobes compared with the lower lobes. An increasing number of facets (f_alv) from top to bottom (12 and 14 in the upper lobes; 14 and 15 in the lower lobes), as well as a decreasing number of alveolar neighbors (nei_alv: 9 and 8 in the upper lobes; 8 and 7 in the lower lobes) from the upper lobes to the lower lobes were observed. We could observe an increasing ratio of alveolar entrance size to the surface size of the alveoli from top to bottom (S_ratio_alv: 0.71 and 0.64 in the upper lobes, 0.73 and 0.70 in the lower lobes). The angles between facet normals (ang_alv) were larger in the upper lobes (67.72° and 62.44°) of both lungs than in the lower lobes (66.19° and 61.30°). By using this new approach of analyzing alveolar 3-D data, which enables the estimation of facet, neighbor, and shape characteristics, we aimed to establish the baseline measures for in-depth studies of mechanical conditions and morphology.


Assuntos
Pulmão , Alvéolos Pulmonares , Humanos , Microtomografia por Raio-X , Pulmão/diagnóstico por imagem , Alvéolos Pulmonares/diagnóstico por imagem , Medidas de Volume Pulmonar
5.
Magn Reson Med ; 90(4): 1396-1413, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37288601

RESUMO

PURPOSE: Exercise-induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time-resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress. METHODS: The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time-resolved images were acquired at 0.55T using a continuous 3D stack-of-spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding-window reconstruction with 90-s temporal resolution in 20-s increments. A supine MRI-compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified. RESULTS: A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (-1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%). CONCLUSION: Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding-window image reconstruction.


Assuntos
Insuficiência Cardíaca , Imageamento por Ressonância Magnética , Animais , Suínos , Pulmão/diagnóstico por imagem , Teste de Esforço
6.
Magn Reson Med ; 89(4): 1522-1530, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36404674

RESUMO

PURPOSE: To determine R2 and R 2 ' $$ {R}_2^{\prime } $$ transverse relaxation rates in healthy lung parenchyma at 0.55 T. This is important in that it informs the design and optimization of new imaging methods for 0.55T lung MRI. METHODS: Experiments were performed in 3 healthy adult volunteers on a prototype whole-body 0.55T MRI, using a custom free-breathing electrocardiogram-triggered, single-slice echo-shifted multi-echo spin echo (ES-MCSE) pulse sequence with respiratory navigation. Transverse relaxation rates R2 and R 2 ' $$ {R}_2^{\prime } $$ and off-resonance ∆f were jointly estimated using nonlinear least-squares estimation. These measurements were compared against R2 estimates from T2 -prepared balanced SSFP (T2 -Prep bSSFP) and R 2 * $$ {R}_2^{\ast } $$ estimates from multi-echo gradient echo, which are used widely but prone to error due to different subvoxel weighting. RESULTS: The mean R2 and R 2 ' $$ {R}_2^{\prime } $$ values of lung parenchyma obtained from ES-MCSE were 17.3 ± 0.7 Hz and 127.5 ± 16.4 Hz (T2  = 61.6 ± 1.7 ms; T 2 ' $$ {\mathrm{T}}_2^{\prime } $$  = 9.5 ms ± 1.6 ms), respectively. The off-resonance estimates ranged from -60 to 30 Hz. The R2 from T2 -Prep bSSFP was 15.7 ± 1.7 Hz (T2  = 68.6 ± 8.6 ms) and R 2 * $$ {R}_2^{\ast } $$ from multi-echo gradient echo was 131.2 ± 30.4 Hz ( T 2 * $$ {\mathrm{T}}_2^{\ast } $$  = 8.0 ± 2.5 ms). Paired t-test indicated that there is a significant difference between the proposed and reference methods (p < 0.05). The mean R2 estimate from T2 -Prep bSSFP was slightly smaller than that from ES-MCSE, whereas the mean R 2 ' $$ {R}_2^{\prime } $$ and R 2 * $$ {R}_2^{\ast } $$ estimates from ES-MCSE and multi-echo gradient echo were similar to each other across all subjects. CONCLUSIONS: Joint estimation of transverse relaxation rates and off-resonance is feasible at 0.55 T with a free-breathing electrocardiogram-gated and navigator-gated ES-MCSE sequence. At 0.55 T, the mean R2 of 17.3 Hz is similar to the reported mean R2 of 16.7 Hz at 1.5 T, but the mean R 2 ' $$ {R}_2^{\prime } $$ of 127.5 Hz is about 5-10 times smaller than that reported at 1.5 T.


Assuntos
Imageamento por Ressonância Magnética , Respiração , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Eletrocardiografia , Pulmão/diagnóstico por imagem
7.
Magn Reson Med ; 89(6): 2318-2331, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744719

RESUMO

PURPOSE: To demonstrate the feasibility of using octafluorocyclobutane (OFCB, c-C4 F8 ) for T1 mapping of lungs in 19 F MRI. METHODS: The study was performed at 7 T in three healthy rats and three rats with pulmonary hypertension. To increase the sensitivity of 19 F MRI, a bent-shaped RF coil with periodic metal strips structure was used. The double flip angle method was used to calculate normalized transmitting RF field (B1n + ) maps and for correcting T1 maps built with the variable flip angle (VFA) method. The ultrashort TE pulse sequence was applied for acquiring MR images throughout the study. RESULTS: The dependencies of OFCB relaxation times on its partial pressure in mixtures with oxygen, air, helium, and argon were obtained. T1 of OFCB linearly depended on its partial pressure with the slope of about 0.35 ms/kPa in the case of free diffusion. RF field inhomogeneity leads to distortion of T1 maps built with the VFA method, and therefore to high standard deviation of T1 in these maps. To improve the accuracy of the T1 maps, the B1n + maps were applied for VFA correction. This contributed to a 2-3-fold decrease in the SD of T1 values in the corresponding maps compared with T1 maps calculated without the correction. Three-dimensional T1 maps were obtained, and the mean T1 in healthy rat lungs was 35 ± 10 ms, and in rat lungs with pulmonary hypertension - 41 ± 9 ms. CONCLUSION: OFCB has a spin-rotational relaxation mechanism and can be used for 19 F T1 mapping of lungs. The calculated OFCB maps captured ventilation defects induced by edema.


Assuntos
Hipertensão Pulmonar , Ratos , Animais , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas
8.
Respir Res ; 24(1): 215, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37649012

RESUMO

RATIONALE: X-ray velocimetry (XV) has been utilized in preclinical models to assess lung motion and regional ventilation, though no studies have compared XV-derived physiologic parameters to measures derived through conventional means. OBJECTIVES: To assess agreement between XV-analysis of fluoroscopic lung images and pitot tube flowmeter measures of ventilation. METHODS: XV- and pitot tube-derived ventilatory parameters were compared during tidal breathing and with bilevel-assisted breathing. Levels of agreement were assessed using the Bland-Altman analysis. Mixed models were used to characterize the association between XV- and pitot tube-derived values and optimize XV-derived values for higher ventilatory volumes. MEASUREMENTS AND MAIN RESULTS: Twenty-four healthy volunteers were assessed during tidal breathing and 11 were reassessed with increased minute ventilation with bilevel-assisted breathing. No clinically significant differences were observed between the two methods for respiratory rate (average Δ: 0.58; 95% limits of agreement: -1.55, 2.71) or duty cycle (average Δ: 0.02; 95% limits of agreement: 0.01, 0.03). Tidal volumes and flow rates measured using XV were lower than those measured using the pitot tube flowmeter, particularly at the higher volume ranges with bilevel-assisted breathing. Under these conditions, a mixed-model based adjustment was applied to the XV-derived values of tidal volume and flow rate to obtain closer agreement with the pitot tube-derived values. CONCLUSION: Radiographically obtained measures of ventilation with XV demonstrate a high degree of correlation with parameters of ventilation. If the accuracy of XV were also confirmed for assessing the regional distribution of ventilation, it would provide information that goes beyond the scope of conventional pulmonary function tests or static radiographic assessments.


Assuntos
Pulmão , Respiração , Adulto , Humanos , Raios X , Radiografia , Volume de Ventilação Pulmonar , Pulmão/diagnóstico por imagem
9.
Sensors (Basel) ; 23(13)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37448069

RESUMO

Smart respiratory therapy is enabled by continual assessment of lung functions. This systematic review provides an overview of the suitability of equipment-to-patient acoustic imaging in continual assessment of lung conditions. The literature search was conducted using Scopus, PubMed, ScienceDirect, Web of Science, SciELO Preprints, and Google Scholar. Fifteen studies remained for additional examination after the screening process. Two imaging modalities, lung ultrasound (LUS) and vibration imaging response (VRI), were identified. The most common outcome obtained from eleven studies was positive observations of changes to the geographical lung area, sound energy, or both, while positive observation of lung consolidation was reported in the remaining four studies. Two different modalities of lung assessment were used in eight studies, with one study comparing VRI against chest X-ray, one study comparing VRI with LUS, two studies comparing LUS to chest X-ray, and four studies comparing LUS in contrast to computed tomography. Our findings indicate that the acoustic imaging approach could assess and provide regional information on lung function. No technology has been shown to be better than another for measuring obstructed airways; hence, more research is required on acoustic imaging in detecting obstructed airways regionally in the application of enabling smart therapy.


Assuntos
Pneumopatias , Pulmão , Humanos , Pulmão/diagnóstico por imagem , Ultrassonografia , Tomografia Computadorizada por Raios X , Acústica
10.
Sensors (Basel) ; 23(18)2023 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37765831

RESUMO

Electrical impedance tomography (EIT) is a non-invasive technique for visualizing the internal structure of a human body. Capacitively coupled electrical impedance tomography (CCEIT) is a new contactless EIT technique that can potentially be used as a wearable device. Recent studies have shown that a machine learning-based approach is very promising for EIT image reconstruction. Most of the studies concern models containing up to 22 electrodes and focus on using different artificial neural network models, from simple shallow networks to complex convolutional networks. However, the use of convolutional networks in image reconstruction with a higher number of electrodes requires further investigation. In this work, two different architectures of artificial networks were used for CCEIT image reconstruction: a fully connected deep neural network and a conditional generative adversarial network (cGAN). The training dataset was generated by the numerical simulation of a thorax phantom with healthy and illness-affected lungs. Three kinds of illnesses, pneumothorax, pleural effusion, and hydropneumothorax, were modeled using the electrical properties of the tissues. The thorax phantom included the heart, aorta, spine, and lungs. The sensor with 32 area electrodes was used in the numerical model. The ECTsim custom-designed toolbox for Matlab was used to solve the forward problem and measurement simulation. Two artificial neural networks were trained with supervision for image reconstruction. Reconstruction quality was compared between those networks and one-step algebraic reconstruction methods such as linear back projection and pseudoinverse with Tikhonov regularization. This evaluation was based on pixel-to-pixel metrics such as root-mean-square error, structural similarity index, 2D correlation coefficient, and peak signal-to-noise ratio. Additionally, the diagnostic value measured by the ROC AUC metric was used to assess the image quality. The results showed that obtaining information about regional lung function (regions affected by pneumothorax or pleural effusion) is possible using image reconstruction based on supervised learning and deep neural networks in EIT. The results obtained using cGAN are strongly better than those obtained using a fully connected network, especially in the case of noisy measurement data. However, diagnostic value estimation showed that even algebraic methods allow us to obtain satisfactory results.


Assuntos
Derrame Pleural , Pneumotórax , Humanos , Impedância Elétrica , Processamento de Imagem Assistida por Computador , Aprendizado de Máquina Supervisionado , Tomografia
11.
Z Rheumatol ; 2023 Oct 17.
Artigo em Alemão | MEDLINE | ID: mdl-37847297

RESUMO

A 69-year-old male patient with seropositive erosive rheumatoid arthritis (RA) presented to our clinic due to progressive dyspnea. High-resolution computed tomography (HRCT) and immunological bronchioalveolar lavage revealed ground-glass opacities and a lymphocytic alveolitis caused by interstitial lung disease (ILD) in RA. Considering previous forms of treatment, disease-modifying antirheumatic drug (DMARD) treatment was switched to tofacitinib. Tofacitinib treatment demonstrated a 33% reduction in ground-glass opacities by artificial intelligence-based quantification of pulmonary HRCT over the course of 6 months, which was associated with an improvement in dyspnea symptoms. In conclusion, tofacitinib represents an effective anti-inflammatory therapeutic option in the treatment of RA-ILD.

12.
Am J Respir Cell Mol Biol ; 67(4): 423-429, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35687482

RESUMO

The current standard for lung function evaluation in murine models is based on forced oscillation technology, which provides a measure of the total airway function but cannot provide information on regional heterogeneity in function. Limited detection of regional airflow may contribute to a discontinuity between airway inflammation and airflow obstruction in models of asthma. Here, we describe quantification of regional airway function using novel dynamic quantitative imaging and analysis to quantify and visualize lung motion and regional pulmonary airflow in four dimensions (4D). Furthermore, temporo-spatial specific ventilation (ml/ml) is used to determine ventilation heterogeneity indices for lobar and sublobar regions, which are directly compared to ex vivo biological analyses in the same sublobar regions. In contrast, oscillation-based technology in murine genetic models of asthma have failed to demonstrate lung function change despite altered inflammation, whereas 4D functional lung imaging demonstrated diminished regional lung function in genetic models relative to wild-type mice. Quantitative functional lung imaging assists in localizing the regional effects of airflow. Our approach reveals repeatable and consistent differences in regional airflow between lung lobes in all models of asthma, suggesting that asthma is characterized by regional airway dysfunctions that are often not detectable in composite measures of lung function. 4D functional lung imaging technology has the potential to transform discovery and development in murine models by mapping out regional areas heterogeneously affected by the disease, thus deciphering pathobiology with greater precision.


Assuntos
Asma , Pulmão , Animais , Asma/diagnóstico por imagem , Modelos Animais de Doenças , Inflamação , Pulmão/diagnóstico por imagem , Camundongos , Respiração
13.
Am J Physiol Lung Cell Mol Physiol ; 322(3): L401-L411, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35080183

RESUMO

Muco-obstructive lung diseases are characterized by airway obstruction and hyperinflation, which can be quantified by imaging. Our aim was to evaluate µCT for longitudinal quantification of muco-obstructive lung disease in ß-epithelial Na+ channel overexpressing (Scnn1b-TG) mice and of the effects of neutrophil elastase (NE) knockout on its progression. Lungs from wild-type (WT), NE-/-, Scnn1b-TG, and Scnn1b-TG/NE-/- mice were scanned with 9-µm resolution at 0, 5, 14, and 60 days of age, and airway and parenchymal disease was quantified. Mucus adhesion lesions (MAL) were persistently increased in Scnn1b-TG compared with WT mice from 0 days (20.25 ± 6.50 vs. 9.60 ± 2.07, P < 0.05), and this effect was attenuated in Scnn1b-TG/NE-/- mice (5.33 ± 3.67, P < 0.001). Airway wall area percentage (WA%) was increased in Scnn1b-TG mice compared with WT from 14 days onward (59.2 ± 6.3% vs. 49.8 ± 9.0%, P < 0.001) but was similar in Scnn1b-TG/NE-/- compared with WT at 60 days (46.4 ± 9.2% vs. 45.4 ± 11.5%, P = 0.97). Air proportion (Air%) and mean linear intercept (Lm) were persistently increased in Scnn1b-TG compared with WT from 5 days on (53.9 ± 4.5% vs. 30.0 ± 5.5% and 78.82 ± 8.44 µm vs. 65.66 ± 4.15 µm, respectively, P < 0.001), whereas in Scnn1b-TG/NE-/-, Air% and Lm were similar to WT from birth (27.7 ± 5.5% vs. 27.2 ± 5.9%, P = 0.92 and 61.48 ± 9.20 µm vs. 61.70 ± 6.73 µm, P = 0.93, respectively). Our results suggest that µCT is sensitive to detect the onset and progression of muco-obstructive lung disease and effects of genetic deletion of NE on morphology of airways and lung parenchyma in Scnn1b-TG mice, and that it may serve as a sensitive endpoint for preclinical studies of novel therapeutic interventions for muco-obstructive lung diseases.


Assuntos
Elastase de Leucócito , Pneumopatias Obstrutivas , Animais , Modelos Animais de Doenças , Canais Epiteliais de Sódio/genética , Elastase de Leucócito/genética , Pulmão/patologia , Pneumopatias Obstrutivas/patologia , Camundongos , Camundongos Knockout , Camundongos Transgênicos
14.
J Cardiovasc Magn Reson ; 24(1): 35, 2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35668497

RESUMO

BACKGROUND: Quantitative assessment of dynamic lung water accumulation is of interest to unmask latent heart failure. We develop and validate a free-breathing 3D ultrashort echo time (UTE) sequence with automated inline image processing to image changes in lung water density (LWD) using high-performance 0.55 T cardiovascular magnetic resonance (CMR). METHODS: Quantitative lung water CMR was performed on 15 healthy subjects using free-breathing 3D stack-of-spirals proton density weighted UTE at 0.55 T. Inline image reconstruction and automated image processing was performed using the Gadgetron framework. A gravity-induced redistribution of LWD was provoked by sequentially acquiring images in the supine, prone, and again supine position. Quantitative validation was performed in a phantom array of vials containing mixtures of water and deuterium oxide. RESULTS: The phantom experiment validated the capability of the sequence in quantifying water density (bias ± SD 4.3 ± 4.8%, intraclass correlation coefficient, ICC = 0.97). The average global LWD was comparable between imaging positions (supine 24.7 ± 3.4%, prone 22.7 ± 3.1%, second supine 25.3 ± 3.6%), with small differences between imaging phases (first supine vs prone 2.0%, p < 0.001; first supine vs second supine - 0.6%, p = 0.001; prone vs second supine - 2.7%, p < 0.001). In vivo test-retest repeatability in LWD was excellent (- 0.17 ± 0.91%, ICC = 0.97). A regional LWD redistribution was observed in all subjects when repositioning, with a predominant posterior LWD accumulation when supine, and anterior accumulation when prone (difference in anterior-posterior LWD: supine - 11.6 ± 2.7%, prone 5.5 ± 2.7%, second supine - 11.4 ± 2.9%). Global LWD maps were calculated inline within 23.2 ± 0.3 s following the image reconstruction using the automated pipeline. CONCLUSIONS: Redistribution of LWD due to gravitational forces can be depicted and quantified using a validated free-breathing 3D proton density weighted UTE sequence and inline automated image processing pipeline on a high-performance 0.55 T CMR system.


Assuntos
Pulmão , Prótons , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
15.
BMC Pulm Med ; 22(1): 71, 2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35216579

RESUMO

BACKGROUND: Prone positioning enables the redistribution of lung weight, leading to the improvement of gas exchange and respiratory mechanics. We aimed to evaluate whether the initial findings of acute respiratory distress syndrome (ARDS) on computed tomography (CT) are associated with the subsequent response to prone positioning in terms of oxygenation and 60-day mortality. METHODS: We retrospectively included patients who underwent prone positioning for moderate to severe ARDS from October 2014 to November 2020 at a medical center in Taiwan. A semiquantitative CT rating scale was used to quantify the extent of consolidation and ground-glass opacification (GGO) in the sternal, central and vertebral regions at three levels (apex, hilum and base) of the lungs. A prone responder was identified by a 20% increase in the ratio of arterial oxygen pressure (PaO2) to the fraction of oxygen (FiO2) or a 20 mmHg increase in PaO2. RESULTS: Ninety-six patients were included, of whom 68 (70.8%) were responders. Compared with nonresponders, responders had a significantly greater median dorsal-ventral difference in CT-consolidation scores (10 vs. 7, p = 0.046) but not in CT-GGO scores (- 1 vs. - 1, p = 0.974). Although dorsal-ventral differences in neither CT-consolidation scores nor CT-GGO scores were associated with 60-day mortality, high total CT-GGO scores (≥ 15) were an independent factor associated with 60-day mortality (odds ratio = 4.07, 95% confidence interval, 1.39-11.89, p = 0.010). CONCLUSIONS: In patients with moderate to severe ARDS, a greater difference in the extent of consolidation along the dependent-independent axis on CT scan is associated with subsequent prone positioning oxygenation response, but not clinical outcome regarding survival. High total CT-GGO scores were independently associated with 60-day mortality.


Assuntos
Troca Gasosa Pulmonar , Síndrome do Desconforto Respiratório , Humanos , Prognóstico , Decúbito Ventral/fisiologia , Troca Gasosa Pulmonar/fisiologia , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
16.
Radiologe ; 62(5): 418-428, 2022 May.
Artigo em Alemão | MEDLINE | ID: mdl-35416476

RESUMO

BACKGROUND: Lung magnetic resonance imaging (MRI) examinations are challenging and have not become established in the routine clinical setting. Recent developments in low-field MRI, combined with computer-assisted algorithms for acquisition and evaluation, promise new perspectives for imaging of pulmonary diseases. OBJECTIVES: This review aims to inform about the physical advantages of low-field MRI for imaging the lungs, provide a review of the sparse literature, and present first results from a new low-field MRI scanner. MATERIALS AND METHODS: This article provides information on the physical principles, an review of the literature, and our first experiences in lung imaging on a modern 0.55 T MRI. CONCLUSION: Low-field MRI (< 1 T) may have technical and economic advantages over higher field strength MRI in lung imaging. The physical preconditions of low-field MRI are advantageous for imaging the lungs due to reduced susceptibility effects, increased transversal relaxation times, and lower specific absorption rates. The lower investment and operating costs may enable increased availability and sustainability. Combining modern sequences and computer-based image processing may expand beyond morphological imaging by providing spatially and temporally resolved functional examinations of the lung parenchyma without ionizing radiation. In critical scenarios, like screening and short-term follow-up examinations, and patients at risk, low-field MRI may bridge the gap. These indications may include acute and chronic pulmonary diseases in pediatric patients and suspected pulmonary embolisms in pregnant women.


Assuntos
Pneumopatias , Imageamento por Ressonância Magnética , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Gravidez , Tórax
17.
J Clin Monit Comput ; 36(3): 599-607, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35552970

RESUMO

This paper provides a review of a selection of papers published in the Journal of Clinical Monitoring and Computing in 2020 and 2021 highlighting what is new within the field of respiratory monitoring. Selected papers cover work in pulse oximetry monitoring, acoustic monitoring, respiratory system mechanics, monitoring during surgery, electrical impedance tomography, respiratory rate monitoring, lung ultrasound and detection of patient-ventilator asynchrony.


Assuntos
Mecânica Respiratória , Ventiladores Mecânicos , Impedância Elétrica , Humanos , Pulmão/diagnóstico por imagem , Monitorização Fisiológica/métodos , Respiração Artificial
18.
J Physiol ; 599(1): 343-356, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33026102

RESUMO

KEY POINTS: The distribution of pulmonary perfusion is affected by gravity, vascular branching structure and active regulatory mechanisms, which may be disrupted by cardiopulmonary disease, but this is not well studied, particularly in rare conditions. We evaluated pulmonary perfusion in patients who had undergone Fontan procedure, patients with pulmonary arterial hypertension (PAH) and two groups of controls using a proton magnetic resonance imaging technique, arterial spin labelling to measure perfusion. Heterogeneity was assessed by the relative dispersion (SD/mean) and gravitational gradients. Gravitational gradients were similar between all groups, but heterogeneity was significantly increased in both patient groups compared to controls and persisted after removing contributions from large blood vessels and gravitational gradients. Patients with Fontan physiology and patients with PAH have increased pulmonary perfusion heterogeneity that is not explainable by differences in mean perfusion, gravitational gradients, or large vessel anatomy. This probably reflects vascular remodelling in PAH and possibly in Fontan physiology. ABSTRACT: Many factors affect the distribution of pulmonary perfusion, which may be disrupted by cardiopulmonary disease, but this is not well studied, particularly in rare conditions. An example is following the Fontan procedure, where pulmonary perfusion is passive, and heterogeneity may be increased because of the underlying pathophysiology leading to Fontan palliation, remodelling, or increased gravitational gradients from low flow. Another is pulmonary arterial hypertension (PAH), where gravitational gradients may be reduced secondary to high pressures, but remodelling may increase perfusion heterogeneity. We evaluated regional pulmonary perfusion in Fontan patients (n = 5), healthy young controls (Fontan control, n = 5), patients with PAH (n = 6) and healthy older controls (PAH control) using proton magnetic resonance imaging. Regional perfusion was measured using arterial spin labelling. Heterogeneity was assessed by the relative dispersion (SD/mean) and gravitational gradients. Mean perfusion was similar (Fontan = 2.50 ± 1.02 ml min-1  ml-1 ; Fontan control = 3.09 ± 0.58, PAH = 3.63 ± 1.95; PAH control = 3.98 ± 0.91, P = 0.26), and the slopes of gravitational gradients were not different (Fontan = -0.23 ± 0.09 ml min-1  ml-1  cm-1 ; Fontan control = -0.29 ± 0.23, PAH = -0.27 ± 0.09, PAH control = -0.25 ± 0.18, P = 0.91) between groups. Perfusion relative dispersion was greater in both Fontan and PAH than controls (Fontan = 1.46 ± 0.18; Fontan control = 0.99 ± 0.21, P = 0.005; PAH = 1.22 ± 0.27, PAH control = 0.91 ± 0.12, P = 0.02) but similar between patient groups (P = 0.13). These findings persisted after removing contributions from large blood vessels and gravitational gradients (all P < 0.05). We conclude that patients with Fontan physiology and PAH have increased pulmonary perfusion heterogeneity that is not explained by differences in mean perfusion, gravitational gradients, or large vessel anatomy. This probably reflects the effects of remodelling in PAH and possibly in Fontan physiology.


Assuntos
Técnica de Fontan , Hipertensão Arterial Pulmonar , Humanos , Pulmão , Perfusão , Circulação Pulmonar
19.
J Clin Immunol ; 41(5): 1064-1071, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33675005

RESUMO

Cartilage-hair hypoplasia is a syndromic immunodeficiency with short stature, chondrodysplasia, and variable degree of immune dysfunction. Patients with cartilage-hair hypoplasia are prone to recurrent respiratory tract infections, and the prevalence of bronchiectasis ranges from 29 to 52%. Pulmonary complications contribute significantly to the mortality; therefore, regular lung imaging is essential. However, the optimal schedule for repeated lung imaging remains unestablished. We determined the rate and correlates of progression of structural lung changes in a prospectively followed cohort of 16 patients with cartilage-hair hypoplasia. We analyzed clinical, laboratory, and pulmonary functional testing data and performed lung magnetic resonance imaging at a median interval of 6.8 years since previous imaging. Imaging findings remained identical or improved due to disappearance of inflammatory changes in all evaluated patients. Patients with subtle signs of bronchiectasis on imaging tended to have low immunoglobulin M levels, as well as suffered from pneumonia during the follow-up. In conclusion, our results suggest slow if any development of bronchiectasis in selected subjects with cartilage-hair hypoplasia.


Assuntos
Bronquiectasia/diagnóstico por imagem , Cabelo/anormalidades , Doença de Hirschsprung/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Osteocondrodisplasias/congênito , Doenças da Imunodeficiência Primária/diagnóstico por imagem , Adolescente , Adulto , Idoso , Bronquiectasia/sangue , Feminino , Cabelo/diagnóstico por imagem , Doença de Hirschsprung/sangue , Humanos , Imunoglobulina M/sangue , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osteocondrodisplasias/sangue , Osteocondrodisplasias/diagnóstico por imagem , Pneumonia/sangue , Pneumonia/diagnóstico por imagem , Doenças da Imunodeficiência Primária/sangue , Estudos Prospectivos , Adulto Jovem
20.
Histochem Cell Biol ; 155(2): 215-226, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32189111

RESUMO

In this article, we present an X-ray tomographic imaging method that is well suited for pulmonary disease studies in animal models to resolve the full pathway from gas intake to gas exchange. Current state-of-the-art synchrotron-based tomographic phase-contrast imaging methods allow for three-dimensional microscopic imaging data to be acquired non-destructively in scan times of the order of seconds with good soft tissue contrast. However, when studying multi-scale hierarchically structured objects, such as the mammalian lung, the overall sample size typically exceeds the field of view illuminated by the X-rays in a single scan and the necessity for achieving a high spatial resolution conflicts with the need to image the whole sample. Several image stitching and calibration techniques to achieve extended high-resolution fields of view have been reported, but those approaches tend to fail when imaging non-stable samples, thus precluding tomographic measurements of large biological samples, which are prone to degradation and motion during extended scan times. In this work, we demonstrate a full-volume three-dimensional reconstruction of an intact rat lung under immediate post-mortem conditions and at an isotropic voxel size of (2.75 µm)3. We present the methodology for collecting multiple local tomographies with 360° extended field of view scans followed by locally non-rigid volumetric stitching. Applied to the lung, it allows to resolve the entire pulmonary structure from the trachea down to the parenchyma in a single dataset. The complete dataset is available online ( https://doi.org/10.16907/7eb141d3-11f1-47a6-9d0e-76f8832ed1b2 ).


Assuntos
Imageamento Tridimensional , Pneumopatias/patologia , Tomografia Computadorizada por Raios X , Animais , Pneumopatias/metabolismo , Ratos , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA