RESUMO
OBJECTIVES: The aim of this study was to determine the best threshold of postintervention minimum stent area (MSA) assessed by optical coherence tomography (OCT) to predict long-term in-stent restenosis (ISR) for 2.5 mm-diameter everolimus-eluting stents (EES). BACKGROUND: Percutaneous coronary intervention (PCI) for small coronary arteries remains challenging. Stent underexpansion is a strong predictor of late ISR. METHODS: We performed a retrospective analysis of 69 lesions in 69 patients undergoing PCI with 2.5 mm-diameter stents using OCT for the assessment of postintervention MSA and subsequent 9-month angiographic follow-up. RESULTS: The rates of angiographic ISR and target lesion revascularization were 7.2% and 1.4%. The postintervention OCT-MSA of EES < 3.5 mm(2) for predicting ISR yielded a sensitivity of 80%, specificity of 71%, positive predictive value of 18%, and negative predictive value of 98%. There was a marginally significant trend between increasing MSA quartiles and decreasing ISR rate (P for trend = 0.07). CONCLUSIONS: Postintervention OCT-MSA of 3.5 mm(2) best predicted 9-month ISR following PCI with 2.5-mm-diameter EES. Further large, prospective, observational studies are warranted that validate this result. © 2015 Wiley Periodicals, Inc.
Assuntos
Reestenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Everolimo/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Tomografia de Coerência Óptica/métodos , Idoso , Angiografia Coronária , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de TempoRESUMO
PURPOSE: To identify intravascular ultrasound (IVUS) measurements that can predict angiographic in-stent restenosis (ISR) following nitinol stent implantation in superficial femoral artery (SFA) lesions. METHODS: A retrospective review was conducted of 97 patients (mean age 72.9±8.9 years; 63 men) who underwent IVUS examination during endovascular treatment of 112 de novo SFA lesions between July 2012 and December 2014. Self-expanding bare stents were implanted in 46 lesions and paclitaxel-eluting stents in 39 lesions. Six months after stenting, follow-up angiography was conducted to assess stent patency. The primary endpoint was angiographic ISR determined by quantitative vascular angiography analysis at the 6-month follow-up. Variables associated with restenosis were sought in multivariate analysis; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). RESULTS: At follow-up, 27 (31.8%) angiographic ISR lesions were recorded. The lesions treated with uncoated stents were more prevalent in the ISR group compared with the no restenosis group (74.1% vs 44.8%, p=0.02). Lesion length was longer (154.4±79.5 vs 109.0±89.3 mm, p=0.03) and postprocedure minimum stent area (MSA) measured by IVUS was smaller (13.9±2.8 vs 16.3±1.6 mm(2), p<0.001) in the ISR group. Multivariate analysis revealed that bare stent use (OR 7.11, 95% CI 1.70 to 29.80, p<0.01) and longer lesion length (OR 1.08, 95% CI 1.01 to 1.16, p=0.04) were predictors of ISR, while increasing postprocedure MSA (OR 0.58, 95% CI 0.41 to 0.82, p<0.01) was associated with lower risk of ISR. Receiver operating characteristic analysis identified a MSA of 15.5 mm(2) as the optimal cutpoint below which the incidence of restenosis increased (area under the curve 0.769). CONCLUSION: Postprocedure MSA can predict ISR in SFA lesions, which suggests that adequate stent enlargement during angioplasty might be required for superior patency.
Assuntos
Ligas , Angiografia , Angioplastia com Balão/instrumentação , Constrição Patológica , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Stents , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Área Sob a Curva , Fármacos Cardiovasculares/administração & dosagem , Distribuição de Qui-Quadrado , Stents Farmacológicos , Feminino , Artéria Femoral/fisiopatologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Paclitaxel/administração & dosagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Curva ROC , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
Impact of the stent expansion index (EXPI) in percutaneous coronary intervention (PCI) for unprotected left main distal bifurcation lesions (ULMD) has been not completely understood especially in current-generation drug-eluting stent (cDES) era. We evaluated the impact of EXPI on clinical outcomes after PCI with cDES for ULMD. We identified 342 patients treated with cDES for ULMD and postintervention intravascular ultrasound between January 2010 and December 2019. In this study, the ratio of minimum stent area (MSA) to reference vessel area at the MSA site was adopted to assess the stent expansion. We defined the patients with the first and second tertile as low-intermediate EXPI group and those with the third tertile as high EXPI group and compared the clinical outcomes between both groups. The primary end point was target lesion failure (TLF). TLF was defined as a composite of cardiac death, target lesion revascularization (TLR) ,and myocardial infarction. The MSA was located in the ostium of left anterior descending coronary artery in most cases (318 of 342 patients; 93.0%). There were no significant differences between both groups in the baseline clinical, lesion, and procedural characteristics. The high EXPI group had lower TLF rate than the low-intermediate EXPI group (10.2% vs 19.9%, log-rank p = 0.033). In conclusion, this is the first report that the higher ratio of MSA to reference vessel area at the MSA site, which was defined as stent EXPI, was associated with more favorable clinical outcomes after PCI for ULMD.
Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Stents , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgiaRESUMO
BACKGROUND: Optical coherence tomography (OCT) is reported to be a feasible and safe imaging modality for the guidance of percutaneous coronary intervention (PCI) of complex lesions. METHODS: This multicenter, prospective registry assessed the minimum stent area (MSA) achieved under OCT guidance. A performance goal of 24% improvement in MSA over and above the recommendation set by the European Association of Percutaneous Cardiovascular Interventions Consensus 2018 (4.5 mm2 MSA for non-left main and 3.5 mm2 for small vessels). The incidence of contrast-induced nephropathy was also assessed. Core lab analysis was conducted. RESULTS: Five hundred patients (average age: 59.4 ± 10.1 years; 83% males) with unstable angina (36.8%), NSTEMI (26.4%), and STEMI (22%) were enrolled. The primary endpoint was achieved in 93% of lesions with stent diameter ≥2.75 mm (average MSA: 6.44 mm2) and 87% of lesions with stent diameter ≤2.5 mm (average MSA: 4.56 mm2). The average MSA (with expansion ≥80% cutoff) was 6.63 mm2 and 4.74 mm2 with a stent diameter ≥2.75 mm and ≤2.5 mm, respectively. According to the core lab analysis, the average MSA achieved with a stent diameter ≥2.75 mm and ≤2.5 mm was 6.23 mm2 and 3.95 mm2, respectively (with expansion ≥80% cutoff). Clinically significant serum creatinine was noted in two patients (0.45%). Major adverse cardiac events at 1 year were noted in 1.2% (n = 6) of the patients; all were cardiac deaths. CONCLUSION: PCI under OCT guidance improves procedural and long-term clinical outcomes in patients with complex lesions not just in a controlled trial environment but also in routine clinical practice.
Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Tomografia de Coerência Óptica/métodos , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Stents , Sistema de Registros , Vasos Coronários , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologiaRESUMO
Why is intravascular ultrasounography (IVUS) highly encouraged for the practical guidance of percutaneous coronary intervention (PCI)? First reason is to understand the mechanism of revascularization. Even if stenoses look similar in angiography, the pathophysiology could be different in each lesion. Second reason is to anticipate possible complications in advance. With prediction and appropriate preparation, most complications can be avoided or managed calmly when they occur. Third reason is to optimize PCI results with interactive IVUS use during the procedure. All these are essential to maximize the results of revascularization while minimizing acute complications, ultimately leading to improved long-term clinical outcomes.
Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos , Resultado do TratamentoRESUMO
Background: The jailing strut configuration with link-free and distal guidewire recrossing (LFD) at the side branch orifice (SBO) reduces incomplete stent apposition (ISA) after kissing balloon technique (KBT) in crossover stenting of coronary bifurcation lesions (CBLs). However, data regarding vascular healing after KBT are lacking. We investigated vascular healing 9 months after crossover stenting followed by KBT with optical coherence tomography (OCT) guidance in a prospective multicenter registry. Methods: Fifty-nine patients with CBLs (LFD, 35 patients; non-LFD, 24 patients) were studied. The jailing configuration of the SB and the wire-recrossing position, incidence of ISA and uncovered struts, and neointima unevenness score (NUS) in the main vessel (MV) after 9 months were determined by off-line 3D-OCT in the core laboratory. Results: The ISA rate was significantly higher at the SB ostium and distal MV after KBT in the non-LFD group, compared to the LFD group. After 9 months, incidence of ISA (18.3 ± 18.2 vs. 6.0 ± 8.7%, p < 0.01) and uncovered struts (8.7 ± 9.9 vs. 4.7 ± 7.3 %, p = 0.08) were higher at the SB ostium with higher SB restenosis in the non-LFD group. In distal MV, NUS was significantly higher (3.1 ± 1.1 vs. 2.5 ± 0.6, p < 0.05). In true-CBLs, an increase in uncovered struts and ISA rate was prominent in the proximal MV and opposite SB. No differences were observed in the 9-month clinical outcomes. Conclusion: Visualization of the wire recrossing point and the SB-jailing strut pattern by OCT plays an important role to optimize the KBT in CBL stenting, resulting in favorable mid-term vascular healing.
RESUMO
OBJECTIVES: The aim of this study was to evaluate various stent expansion indexes to determine the best predictor of clinical outcomes. BACKGROUND: Numerous intravascular ultrasound (IVUS) studies have shown minimum stent area (MSA) to be the most powerful predictor of future events. METHODS: ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective, multicenter registry of 8,582 patients undergoing percutaneous coronary intervention (PCI) with drug-eluting stents. Native coronary artery lesions treated with IVUS-guided PCI with final analyzable IVUS were included. Ten stent expansion indexes (MSA, MSA/vessel area at MSA site, conventional stent expansion [MSA/average of proximal and distal reference luminal area], minimum stent expansion using Huo-Kassab or linear model accounting for vessel tapering, stent asymmetry [minimum/maximum stent diameter within the entire stent], stent eccentricity [smallest minimum/maximum stent diameter at a single slice within the stent], IVUS-XPL [Impact of intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions] criteria, ULTIMATE [Intravascular Ultrasound Guided Drug Eluting Stents Implantation in "All-Comers" Coronary Lesions] criteria, and ILUMIEN IV criteria) were evaluated for their associations with lesion-specific 2-year clinically driven target lesion revascularization (TLR) or definite stent thrombosis. RESULTS: Overall, 2,140 lesions in 1,831 patients were included; final MSA measured 6.2 ± 2.4 mm2. Among the 10 stent expansion indexes, only MSA/vessel area at the MSA site was independently associated with 2-year clinically driven TLR or definite stent thrombosis (hazard ratio: 0.77; 95% confidence interval: 0.59-0.99; P = 0.04) after adjusting for morphologic and procedural parameters. CONCLUSIONS: In this IVUS-guided PCI cohort with excellent final MSA overall, stent/vessel area at the MSA site, an index of relative stent expansion, was superior to absolute MSA and other expansion indexes in predicting 2-year clinically driven TLR or definite stent thrombosis.
Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Stents , Resultado do Tratamento , Ultrassonografia de IntervençãoRESUMO
The minimum stent area (MSA) has been clinically established as a significant predictor of restenosis, thrombosis, and ischemia using intra-vascular ultrasound (IVUS). Unfortunately, IVUS measurements are far from routine because of significant cost of IVUS, the training required, the subjectivity of image interpretation and the time added to the procedure. The objective of this study is to verify the accuracy of a conductance catheter for stent sizing. Here, we introduce an easy and entirely objective device and method for real time determination of MSA. A 10 kHz, 35 µA rms current is passed through the external electrodes of an intravascular catheter while the conductance is measured across a separate set of electrodes. Both phantom and ex vivo validations of metal stent sizing in five porcine carotid arteries were confirmed. The accuracy of the measurements were found to be excellent in phantoms (root mean square, rms, of 3.4% of actual value) and in ex-vivo vessels (rms = 3.2% of measured value). An offset of conductance occurs when a conductive metal stent (e.g., bare metal stent) is deployed in the vessel, while the slope remains the same. This offset is absent in the case of drug eluting stent where the metal is coated (i.e., insulated) or non-metal bioresorbable stent. The present device makes easy, accurate and reproducible measurements of the size of stented blood vessels within 3.2% rms error. This device provides an alternative method to sizing of stent (i.e., MSA) in real-time without subjective interpretation and with less cost than IVUS.
RESUMO
In-stent restenosis (ISR) has been an area of concern for the interventional cardiologists since the era of bare-metal stents (BMS). Although the incidence of ISR is more with BMS as compared to drug-eluting stents, due to the underlying pathophysiological differences, between the two; the latter has a more accelerated course and is difficult to treat. In this case report, we try to address this issue of difficult treatment of ISR and the benefit of using optical coherence tomography in these situations.