Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Sensors (Basel) ; 24(13)2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-39000845

RESUMO

Metal thickness measurements are essential in various industrial applications, yet current non-contact ultrasonic methods face limitations in range and accuracy, hindering the widespread adoption of electromagnetic ultrasonics. This study introduces a novel combined thickness measurement method employing fuzzy logic, with the aim of broadening the applicational scope of the EMAT. Leveraging minimal hardware, this method utilizes the short pulse time-of-flight (TOF) technique for initial thickness estimation, followed by secondary measurements guided by fuzzy logic principles. The integration of measurements from the resonance, short pulse echo, and linear frequency modulation echo extends the measurement range while enhancing accuracy. Rigorous experimental validation validates the method's effectiveness, demonstrating a measurement range of 0.3-1000.0 mm with a median error within ±0.5 mm. Outperforming traditional methods like short pulse echoes, this approach holds significant industrial potential.

2.
Sensors (Basel) ; 24(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38732937

RESUMO

In this article, we address the problem of synchronizing multiple analog-to-digital converter (ADC) and digital-to-analog converter (DAC) chains in a multi-channel system, which is constrained by the sampling frequency and inconsistencies among the components during system integration. To evaluate and compensate for the synchronization differences, we propose a pulse compression shape-based algorithm to measure the entire delay parameter of the ADC/DAC chain, which achieves sub-sampling resolution by mapping the shape of the discrete pulse compression peak to the signal propagation delay. Moreover, owing to the matched filtering in the pulse compression process, the algorithm exhibits good noise performance and is suitable for wireless scenarios. Experiments verified that the algorithm can achieve precise measurements with sub-sampling resolution in scenarios where the signal-to-noise ratio (SNR) is greater than -10 dB.

3.
Sensors (Basel) ; 24(18)2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39338629

RESUMO

Forward jammers replicate and retransmit radar signals back to generate coherent jamming signals and false targets, making anti-jamming an urgent issue in electronic warfare. Jamming transmitters work at saturation to maximize the retransmission power such that only the phase information of the angular waveform at the designated direction of arrival (DOA) is retained. Therefore, amplitude modulation of MIMO radar angular waveforms offers an advantage in combating forward jamming. We address both the design of unimodular MIMO waveforms and their associated mismatch filters to confront mainlobe jamming in this paper. Firstly, we design the MIMO waveforms to maximize the discrepancy between the retransmitted jamming and the spatially synthesized radar signal. We formulate the problem as unconstrained non-linear optimization and solve it using the conjugate gradient method. Particularly, we introduce fast Fourier transform (FFT) to accelerate the numeric calculation of both the objection function and its gradient. Secondly, we design a mismatch filter to further suppress the filtered jamming through convex optimization in polynomial time. The simulation results show that for an eight-element MIMO radar, we are able to reduce the correlation between the angular waveform and saturated forward jamming to -6.8 dB. Exploiting this difference, the mismatch filter can suppress the jamming peak by 19 dB at the cost of an SNR loss of less than 2 dB.

4.
Sensors (Basel) ; 23(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37112283

RESUMO

The main disadvantage of the electromagnetic acoustic transducer (EMAT) is low energy-conversion efficiency and low signal-to-noise ratio (SNR). This problem can be improved by pulse compression technology in the time domain. In this paper, a new coil structure with unequal spacing was proposed for a Rayleigh wave EMAT (RW-EMAT) to replace the conventional meander line coil with equal spacing, which allows the signal to be compressed in the spatial domain. Linear and nonlinear wavelength modulations were analyzed to design the unequal spacing coil. Based on this, the performance of the new coil structure was analyzed by the autocorrelation function. Finite element simulation and experiments proved the feasibility of the spatial pulse compression coil. The experimental results show that the received signal amplitude is increased by 2.3~2.6 times, the signal with a width of 20 µs could be compressed into a δ-like pulse of less than 0.25 µs and the SNR is increased by 7.1-10.1 dB. These indicate that the proposed new RW-EMAT can effectively enhance the strength, time resolution and SNR of the received signal.

5.
Sensors (Basel) ; 23(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38139547

RESUMO

In this paper, we utilize micro-computed tomography (micro-CT) to obtain micro-CT images with a resolution of 60 µm and establish a micro-CT model based on the k-wave toolbox, which can visualize the microstructures in trabecular bone, including pores and bone layers. The transcranial ultrasound phased array focusing field characteristics in the micro-CT model are investigated. The ultrasonic waves are multiply scattered in skull and time delays calculations from the transducer to the focusing point are difficult. For this reason, we adopt the pulse compression method and the linear frequency modulation Barker code to compute the time delay and implement phased array focusing in the micro-CT model. It is shown by the simulation results that ultrasonic loss is mainly caused by scattering from the microstructures of the trabecular bone. The ratio of main and side lobes of the cross-correlation calculation is improved by 5.53 dB using the pulse compression method. The focusing quality and the calculation accuracy of time delay are improved. Meanwhile, the beamwidth at the focal point and the sound pressure amplitude decrease with the increase in the signal frequency. Focusing at different depths indicates that the beamwidth broadens with the increase in the focusing depth, and beam deflection focusing maintains good consistency in the focusing effect at a distance of 9 mm from the focal point. This indicates that the phased-array method has good focusing results and focus tunability in deep cranial brain. In addition, the sound pressure at the focal point can be increased by 8.2% through amplitude regulation, thereby enhancing focusing efficiency. The preliminary experiment verification is conducted with an ex vivo skull. It is shown by the experimental results that the phased array focusing method using pulse compression to calculate the time delay can significantly improve the sound field focusing effect and is a very effective transcranial ultrasound focusing method.


Assuntos
Encéfalo , Ultrassom , Microtomografia por Raio-X , Ultrassonografia , Encéfalo/diagnóstico por imagem , Crânio/diagnóstico por imagem
6.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991837

RESUMO

We introduce a novel long-range traffic monitoring system for vehicle detection, tracking, and classification based on fiber-optic distributed acoustic sensing (DAS). High resolution and long range are provided by the use of an optimized setup incorporating pulse compression, which, to our knowledge, is the first time that is applied to a traffic-monitoring DAS system. The raw data acquired with this sensor feeds an automatic vehicle detection and tracking algorithm based on a novel transformed domain that can be regarded as an evolution of the Hough Transform operating with non-binary valued signals. The detection of vehicles is performed by calculating the local maxima in the transformed domain for a given time-distance processing block of the detected signal. Then, an automatic tracking algorithm, which relies on a moving window paradigm, identifies the trajectory of the vehicle. Hence, the output of the tracking stage is a set of trajectories, each of which can be regarded as a vehicle passing event from which a vehicle signature can be extracted. This signature is unique for each vehicle, allowing us to implement a machine-learning algorithm for vehicle classification purposes. The system has been experimentally tested by performing measurements using dark fiber in a telecommunication fiber cable running in a buried conduit along 40 km of a road open to traffic. Excellent results were obtained, with a general classification rate of 97.7% for detecting vehicle passing events and 99.6% and 85.7% for specific car and truck passing events, respectively.

7.
Sensors (Basel) ; 23(5)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36904887

RESUMO

In order to solve the difficulty in localization and poor signal-to-noise ratio (SNR) of the angled shear vertical wave (SV wave) electromagnetic acoustic transducer (EMAT) in cracks detection of high-temperature carbon steel forgings, a finite element (FE) model of the angled SV wave EMAT detection process was established, and the influence of specimen temperature on the EMAT excitation, propagation, and reception processes was analyzed. A high-temperature resistant angled SV wave EMAT was designed to detect carbon steel from 20 °C to 500 °C, and the influence law of the angled SV wave at different temperatures was analyzed. Then a circuit-field coupled FE model of angled SV wave EMAT in the carbon steel detection process based on the Barker code pulse compression technique was established, and the effects of the Barker code element length, impedance matching method, and matching component parameters on the pulse compression effect were analyzed. In addition, the noise suppression effect and the SNR of the crack-reflected wave in the tone-burst excitation method and the Barker code pulse compression technique were compared. The results show that the amplitude of the block-corner reflected wave decreases from 556 mV to 195 mV, and the SNR decreases from 34.9 dB to 23.5 dB when the specimen temperature increases from 20 °C to 500 °C. When the temperature is 500 °C, the SNR of the crack-reflected wave obtained by the Barker code pulse compression technique can be improved by 9.2 dB compared to the tone-burst excitation method with 16 synchronous averages. The study can provide technical and theoretical guidance for online crack detection for high-temperature carbon steel forgings.

8.
Wiad Lek ; 76(1): 182-188, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36883508

RESUMO

OBJECTIVE: The aim: To study the effect of cryotherapy with adjustable pulse compression in patients after arthroscopic partial meniscectomy on the functional state of the knee joint in the early period of rehabilitation. PATIENTS AND METHODS: Materials and methods: A total of 63 patients took part in the research: the experimental group included 32 patients (23 men and 9 women), and the control group - 31 patients (21 men and 10 women). In order to determine the effect on the functional state of the knee joint after arthroscopic partial meniscectomy in the experimental group, cryotherapy with adjustable pulse compression was used with the help of «GIOCO CRYO - 2¼ system; ice bags were used in the control group. In the research process, the following methods were used: visual analogue point scale, sonography, goniometry and myotonometry. RESULTS: Results: It was found that in the experimental group, under the influence of cryotherapy with adjustable pulse compression, there was a progressive decrease in the intensity of the pain syndrome, the accumulation of reactive synovial fluid, a dynamic increase in the amplitude of movements of the operated joint, and an improvement in the muscle tone of the quadriceps femoris (p<0,05-0,001). CONCLUSION: Conclusions: Thus, cryotherapy with adjustable pulse compression has shown a positive effect on the functional state of the knee joint in the early period of patients' rehabilitation, after partial meniscectomy and can be recommended for use in clinical practice.


Assuntos
Medicina , Meniscectomia , Masculino , Humanos , Feminino , Articulação do Joelho/cirurgia , Crioterapia , Frequência Cardíaca
9.
Sensors (Basel) ; 21(20)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34696154

RESUMO

Traditional tone burst excitation cannot attain a high output resolution, due to the time duration. The received signal is much longer than that of excitation during the propagation, which can increase the difficulty of signal processing, and reduce the resolution. Therefore, it is of significant interest to develop a general methodology for crack quantification through the optimal design of the excitation waveform and signal-processing methods. This paper presents a new crack size quantification method based on high-resolution Lamb waves. The linear chirp (L-Chirp) signal and Golay complementary code (GCC) signal are used as Lamb wave excitation signals. After dispersion removal, these excitation waveforms, based on pulse compression, can effectively improve the inspection resolution in plate-like structures. A series of simulations of both healthy plates and plates with different crack sizes are performed by Abaqus CAE, using different excitation waveforms. The first wave package of the S0 mode after pulse compression is chosen to extract the damage features. A multivariate regression model is proposed to correlate the damage features to the crack size. The effectiveness of the proposed crack size quantification method is verified by a comparison with tone burst excitation, and the accuracy of the crack size quantification method is verified by validation experiments.


Assuntos
Compressão de Dados , Processamento de Sinais Assistido por Computador
10.
Sensors (Basel) ; 20(8)2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-32316414

RESUMO

Experiments have been performed to demonstrate that ultrasound in the 100-400 kHz frequency range can be used to propagate signals through various types of industrial insulation. This is despite the fact that they are highly attenuating to ultrasonic signals due to scattering and viscoelastic effects. The experiments used a combination of piezocomposite transducers and pulse compression processing. This combination allowed signal-to-noise levels to be enhanced so that signals reflected from the surface of an insulated and cladded steel pipe could be obtained.

11.
Sensors (Basel) ; 20(9)2020 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-32344899

RESUMO

Linear frequency modulation (LFM) waveforms have high Doppler-shift endurance because of the relative wide modulation bandwidth to the Doppler variation. The Doppler shift of the moving objects, nevertheless, constantly introduces obscure detection range offsets despite the exceptional Doppler tolerance in detection energy loss from LFM. An up-down-chirped LFM waveform is an efficient scheme to resolve the true target location and velocity by averaging the detection offset of two detection pairs from each single chirp LFM in opposite slopes. However, in multiple velocity-vary-target scenarios, without an efficient grouping scheme to find the detection pair of each moving target, the ambiguous detection results confine the applicability of precise target estimation by using these Doppler-tolerated waveforms. A succinct, three-multi-Doppler-shift-compensation (MDSC) scheme is applied to resolve the range and velocity of two moving objects by sorting the correct LFM detection pair of each target, even though the unresolvable scenarios of two close-by targets imply a fatal disability of detecting objects under a cluttered background. An innovative clutter-suppressed multi-Doppler-shift compensation (CS-MDSC) scheme is introduced in this research to compensate for the critical insufficient of resolving two overlapping objects with different velocities by solely MDSC. The CS-MDSC has been shown to successfully overcome this ambiguous scenario by integrating Doppler-selective moving target indication (MTI) filters to mitigate the distorting of near-zero-Doppler objects.

12.
Sensors (Basel) ; 19(20)2019 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-31640186

RESUMO

A coherent pulse-compression lidar system based on a 90-degree optical hybrid is demonstrated in this paper. In amplitude modulation (AM) mode, the returned RF chirp signal will be influenced by a random phase difference between local oscillator and echo light, causing fluctuations in the ranging results, and as a result the detection probability is small. By using the 90-degree optical hybrid, two orthogonal complementary signals are obtained to stabilize the result so as to increase the detection probability. We performed an experiment to measure the distance of a white printed wall which is about 65 m away from the system. The detection probability increased from 65% to 99.88%, and the precision is improved from 0.42 m to 0.27 m.

13.
Sensors (Basel) ; 19(10)2019 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-31137481

RESUMO

To explore lidar, which can simultaneously measure the distance and velocity of long-distance targets at high resolution, a coherent lidar system based on chirp pulse compression has been studied. Instead of a conventional acousto-optic modulator (AOM), we used an electro-optic modulator (EOM) to modulate a continuous 1550 nm laser. Using EOM, the resolution of the lidar is higher and the system simpler. The electrical waveform used to modulate the laser is a chirp pulse, which has a sweeping bandwidth of 98 MHz, a duration of 10 µs, and a pulse repetition rate of 20 kHz. The result of 100 measurements shows that the system may yield accurate information in range, ±22 cm, and radial velocity, ±1.066 cm/s.

14.
Sensors (Basel) ; 19(9)2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31086005

RESUMO

Ablative materials are used extensively in the aerospace industry for protection against high thermal stresses and temperatures, an example being glass/silicone composites. The extreme conditions faced and the cost-risk related to the production/operating stage of such high-tech materials indicate the importance of detecting any anomaly or defect arising from the manufacturing process. In this paper, two different non-destructive testing techniques, namely active thermography and ultrasonic testing, have been used to detect a delamination in a glass/silicone composite. It is shown that a frequency modulated chirp signal and pulse-compression can successfully be used in active thermography for detecting such a delamination. Moreover, the same type of input signal and post-processing can be used to generate an image using air-coupled ultrasound, and an interesting comparison between the two can be made to further characterise the defect.

15.
Sensors (Basel) ; 19(9)2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31086016

RESUMO

In this paper, the method of applying cognitive radar technology to marine radar is studied, and the cognitive marine radar structure and transmitted signal model with three control parameters are constructed. The selection method of waveform control parameters, which is based on the target spatial distribution and the reference target detection effect with the minimum emission energy as the criterion, is given. The transmission signal control selection method given in this paper can flexibly realize different emission signal groups of m × n × p groups by independently setting the values m, n and p of three control parameters. It does not require radar hardware circuit reconstruction to meet the radar waveform changes. This is more convenient for the technical realization of cognitive marine radar. According to the method of this paper, a cognitive marine radar test system was constructed. The experimental results show that the proposed radar could reduce the emission energy by 15.9 dB compared with the traditional fixed-parameter pulse compression marine radar under the experimental conditions.

16.
Sensors (Basel) ; 19(19)2019 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-31597266

RESUMO

The use of different spectral bands in the inspection of artworks is highly recommended to identify the maximum number of defects/anomalies (i.e., the targets), whose presence ought to be known before any possible restoration action. Although an artwork cannot be considered as a composite material in which the zero-defect theory is usually followed by scientists, it is possible to state that the preservation of a multi-layered structure fabricated by the artist's hands is based on a methodological analysis, where the use of non-destructive testing methods is highly desirable. In this paper, the infrared thermography and hyperspectral imaging methods were applied to identify both fabricated and non-fabricated targets in a canvas painting mocking up the famous character "Venus" by Botticelli. The pulse-compression thermography technique was used to retrieve info about the inner structure of the sample and low power light-emitting diode (LED) chips, whose emission was modulated via a pseudo-noise sequence, were exploited as the heat source for minimizing the heat radiated on the sample surface. Hyper-spectral imaging was employed to detect surface and subsurface features such as pentimenti and facial contours. The results demonstrate how the application of statistical algorithms (i.e., principal component and independent component analyses) maximized the number of targets retrieved during the post-acquisition steps for both the employed techniques. Finally, the best results obtained by both techniques and post-processing methods were fused together, resulting in a clear targets map, in which both the surface, subsurface and deeper information are all shown at a glance.

17.
Sensors (Basel) ; 18(5)2018 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-29772676

RESUMO

For synthetic aperture radars, it is difficult to achieve forward-looking and staring imaging with high resolution. Fortunately, terahertz coded-aperture imaging (TCAI), an advanced radar imaging technology, can solve this problem by producing various irradiation patterns with coded apertures. However, three-dimensional (3D) TCAI has two problems, including a heavy computational burden caused by a large-scale reference signal matrix, and poor resolving ability at low signal-to-noise ratios (SNRs). This paper proposes a 3D imaging method based on geometric measures (GMs), which can reduce the computational burden and achieve high-resolution imaging for low SNR targets. At extremely low SNRs, it is difficult to detect the range cells containing scattering information with an ordinary range profile. However, this difficulty can be overcome through GMs, which can enhance the useful signal and restrain the noise. By extracting useful data from the range profile, target information in different imaging cells can be simultaneously reconstructed. Thus, the computational complexity is distinctly reduced when the 3D image is obtained by combining reconstructed 2D imaging results. Based on the conventional TCAI (C-TCAI) model, we deduce and build a GM-based TCAI (GM-TCAI) model. Compared with C-TCAI, the experimental results demonstrate that GM-TCAI achieves a more impressive performance with regards to imaging ability and efficiency. Furthermore, GM-TCAI can be widely applied in close-range imaging fields, for instance, medical diagnosis, nondestructive detection, security screening, etc.

18.
J Synchrotron Radiat ; 23(1): 141-51, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698056

RESUMO

High-brightness X-ray radiation produced by third-generation synchrotron light sources (TGLS) has been used for numerous time-resolved investigations in many different scientific fields. The typical time duration of X-ray pulses delivered by these large-scale machines is about 50-100 ps. A growing number of time-resolved studies would benefit from X-ray pulses with two or three orders of magnitude shorter duration. Here, techniques explored in the past for shorter X-ray pulse emission at TGLS are reviewed and the perspective towards the realisation of picosecond and sub-picosecond X-ray pulses are discussed.

19.
J Lightwave Technol ; 33(9): 1814-1820, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26166939

RESUMO

The supercontinuum generated exclusively in the normal dispersion regime of a nonlinear fiber is widely believed to possess low optical noise and high spectral coherence. The recent development of flattened all-normal dispersion fibers has been motivated by this belief to construct a general-purpose broadband coherent optical source. Somewhat surprisingly, we identify a large short-term polarization noise in this type of supercontinuum generation that has been masked by the total-intensity measurement in the past, but can be easily detected by filtering the supercontinuum with a linear polarizer. Fortunately, this hidden intrinsic noise and the accompanied spectral decoherence can be effectively suppressed by using a polarization-maintaining all-normal dispersion fiber. A polarization-maintaining coherent supercontinuum laser is thus built with a broad bandwidth (780-1300 nm) and high spectral power (~1 mW/nm).

20.
Ultrason Imaging ; 37(3): 205-23, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25270352

RESUMO

Pulse compression methods improve the quality of ultrasonic medical images. In comparison with standard broadband pulse techniques, these methods enhance the contrast-to-noise ratio (CNR) and increase the probing depth without any perceptible loss of spatial resolution. The Golay compression technique is analyzed here in the context of ultrasonic computed tomography, first on a one-dimensional target and second on a very low-contrast phantom probed using a half-ring array tomograph. The imaging performances were assessed based on the image CNR. The improvement obtained (up to 40%) depends, however, on the number of coherently associated diffraction projections. Beyond a certain number, few advantages were observed. Advances in ultrasound computed tomography suggest that pulse compression methods should provide a useful means of optimizing the trade-off between the image quality and the probing sampling density.


Assuntos
Compressão de Dados/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Acústica , Algoritmos , Compressão de Dados/estatística & dados numéricos , Imagens de Fantasmas , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA