Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
ScientificWorldJournal ; 2021: 6659995, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33927582

RESUMO

The ever-growing commercialization of poor-quality and substandard medicines, especially anti-infectives characterized by inadequate postmarket surveillance by stakeholders remains a major global health challenge, particularly in developing countries, where antibiotic drug resistance and its repercussions on human health remain dominant. This research sought to evaluate the pharmaceutical quality of six randomly selected brands of cefuroxime axetil tablets (250 mg) marketed in the Greater Accra region of Ghana. The selected brands were coded and subjected to both compendial and noncompendial tests. Statistical analysis and model-independent parameter (similarity factor, f2) were employed in analyzing the dissolution profiles of all the brands. All brands including the reference brand conformed to the pharmacopeial specifications for both compendial and noncompendial tests, indicating that they were of good quality. However, there were significant variations (p < 0.05) in the disintegration time amongst the various brands. All the brands had ƒ2 values > 50 indicating similarity of their drug release profiles with the innovator. Hence, all the sampled cefuroxime axetil brands can be considered as pharmaceutical equivalents to the innovator drug. These brands can, therefore, be used as a substitute for the innovator drug by physicians to patients in cases of unaffordability or unavailability of the innovator brand.


Assuntos
Antibacterianos/normas , Cefuroxima/análogos & derivados , Cefuroxima/análise , Cefuroxima/normas , Medicamentos Falsificados , Armazenamento de Medicamentos , Gana , Controle de Qualidade , Comprimidos/normas
2.
Crit Care ; 24(1): 646, 2020 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-33189146

RESUMO

BACKGROUND: Sepsis is often treated with penicillin-binding protein 3 (PBP-3) acting ß-lactam antibiotics, such as piperacillin-tazobactam, cefotaxime, and meropenem. They cause considerable bacterial structural changes and have in vitro been associated with an increased inflammatory response. In a clinically relevant large animal sepsis model, our primary aim was to investigate whether bacteria killed by a PBP-3-active antibiotic has a greater effect on the early inflammatory response and organ dysfunction compared with corresponding amounts of live or heat-killed bacteria. A secondary aim was to determine whether the addition of an aminoglycoside could mitigate the cefuroxime-induced response. METHOD: Killed or live Escherichia coli were administrated as a 3-h infusion to 16 healthy pigs in a prospective, randomized controlled interventional experimental study. Cefuroxime was chosen as the PBP-3-active antibiotic and tobramycin represented the aminoglycosides. The animals were randomized to receive (I) bacteria killed by cefuroxime, (II) live bacteria, (III) bacteria killed by heat, or (IV) bacteria killed by the combination of cefuroxime and tobramycin. Plasma endotoxin, tumor necrosis factor alpha, interleukin-6, interleukin-10, leukocytes, and organ function were recorded at the start of the experiment and then hourly for 6 h. RESULTS: Differences in dynamics of concentration over time between the four treatment groups were found for the three cytokines (p < 0.001). Animals receiving cefuroxime-killed bacteria demonstrated higher responses than those receiving live (p < 0.05) or heat-killed bacteria (p < 0.01). The addition of tobramycin reduced the cefuroxime-induced responses (p < 0.001). The cytokine responses were associated with leucocyte activation that was further associated with pulmonary dysfunction and increases in lactate (p < 0.01). CONCLUSIONS: In comparison with live or heat-killed bacteria, bacteria killed by a PBP-3-active antibiotic induced an increased inflammatory response that appears to be associated with deteriorated organ and cellular function. The addition of an aminoglycoside to the PBP-3-active antibiotic reduced that response.


Assuntos
Inflamação/etiologia , Insuficiência de Múltiplos Órgãos/etiologia , Proteínas de Ligação às Penicilinas/efeitos adversos , Sepse/tratamento farmacológico , Animais , Cefuroxima/análise , Cefuroxima/farmacologia , Cefuroxima/uso terapêutico , Modelos Animais de Doenças , Endotoxinas/análise , Endotoxinas/sangue , Escherichia coli/efeitos dos fármacos , Escherichia coli/patogenicidade , Infecções por Escherichia coli/tratamento farmacológico , Infecções por Escherichia coli/fisiopatologia , Inflamação/complicações , Inflamação/fisiopatologia , Interleucina-10/análise , Interleucina-10/sangue , Interleucina-6/análise , Interleucina-6/sangue , Insuficiência de Múltiplos Órgãos/complicações , Insuficiência de Múltiplos Órgãos/fisiopatologia , Escores de Disfunção Orgânica , Proteínas de Ligação às Penicilinas/uso terapêutico , Estudos Prospectivos , Sepse/fisiopatologia , Suínos , Tobramicina/efeitos adversos , Tobramicina/farmacologia , Tobramicina/uso terapêutico , Fator de Necrose Tumoral alfa/análise , Fator de Necrose Tumoral alfa/sangue
3.
Biomed Chromatogr ; 34(2): e4737, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31950509

RESUMO

In this paper, we present the incurred sample reanalysis (ISR) data for cefuroxime in various ocular tissues of rabbits. Based on the cefuroxime concentration vs. time profile in various ocular tissues, three chosen time points enabled ISR assessment. Cefuroxime was quantitated in the ocular tissues using a published liquid chromatography-electrospray ionization/tandem mass spectrometry method operated under the multiple reaction-monitoring mode in positive ion mode. Regardless of the ocular tissue, the linearity range was 12.7-2760 ng/ml with a correlation coefficient (r2 ) of ≥0.996. All of the ISR samples representing various ocular tissues met the acceptance criteria. To the best of our knowledge, this is the first report showing the ISR of ocular tissues in any species.


Assuntos
Cefuroxima/análise , Cromatografia Líquida/métodos , Olho/química , Espectrometria de Massas em Tandem/métodos , Animais , Modelos Lineares , Coelhos , Manejo de Espécimes
4.
Br J Clin Pharmacol ; 85(4): 818-826, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30636060

RESUMO

AIMS: Surgical site infections contribute to morbidity and mortality after surgery. The authors hypothesized that higher antibiotic tissue concentrations can be reached for a prolonged time span by continuous administration of prophylactic cefuroxime compared to bolus administration. METHODS: Twelve patients undergoing elective cardiac surgery were investigated. Group A received 1.5 g cefuroxime as bolus infusions before surgery, and 12 and 24 hours thereafter. In group B, a continuous infusion of 3.0 g cefuroxime was started after a bolus of 1.5 g. Cefuroxim levels were determined in blood and tissue (microdialysis). T-test, Wilcoxon signed rank test and χ2 test were used for statistical analysis. RESULTS: The area under the curve (AUC) of plasma cefuroxime concentrations was greater in group B (399 [333-518]) as compared to group A (257 [177-297] h mg L-1 , [median and interquartile range], P = .026). Furthermore, a significantly longer percentage of time > minimal inhibitory concentrations of 2 mg L-1 (100% vs 50%), 4 mg L-1 (100% vs 42%), 8 mg L-1 (100% vs 17%) and 16 mg L-1 (83% vs 8%) was found for free plasma cefuroxime in group B. In group B, area under the curve in subcutaneous tissue (78 [61-113] h mg L-1 ) and median peak concentration (33 [26-38] mg L-1 ) were markedly higher compared to group A (P = 0.041 and P = .026, respectively). CONCLUSIONS: Higher cefuroxime concentrations were measured in plasma and subcutaneously over a prolonged period of time when cefuroxime was administered continuously. The clinical implication of this finding still has to be elucidated.


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia/métodos , Cefuroxima/administração & dosagem , Infecção da Ferida Cirúrgica/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/análise , Antibacterianos/farmacocinética , Área Sob a Curva , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cefuroxima/análise , Cefuroxima/farmacocinética , Esquema de Medicação , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Plasma/química , Gordura Subcutânea/química , Infecção da Ferida Cirúrgica/etiologia , Distribuição Tecidual
5.
Br J Clin Pharmacol ; 84(9): 2020-2028, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29761538

RESUMO

AIMS: Very little data exist regarding the effect of cardiopulmonary bypass (CPB) on cefuroxime (CXM) pharmacokinetics in children less than one year of age. METHODS: 50 mg kg-1 CXM i.v. after induction were followed by 75 mg kg-1 into the CPB circuit. In 42 patients undergoing cardiac surgery, 15-20 samples were obtained between 5 and 360 min after the first dose. Total CXM concentrations were measured by high-performance liquid chromatography and a pharmacokinetic/pharmacodynamic (PK/PD) modelling was performed. RESULTS: Using a fixed protein binding of 15.6% for CXM, peak plasma concentrations of unbound CXM were 229 ± 52 µg ml-1 after the first bolus and 341 ± 86 µg ml-1 on CPB. Nadir concentrations before CPB were 69 ± 20 µg ml-1 and six hours later decreased to 41 ± 19 µg ml-1 with and 24 ± 14 µg ml-1 without CPB. A two-compartment model was fitted with the main covariates body weight, CPB and postmenstrual age (PMA). PK parameters were as follows: systemic clearance, 5.15 [95% CI 4.5-5.8] l h-1 ; central volume of distribution, 11.25 [9.41-13.09] l; intercompartmental clearance, 18.19 [14.79-21.58] l h-1 ; and peripheral volume, 17.07 [15.7-18.5] L. ƒT > MIC of 32 µg ml-1 for an 8-h time period was between 70 and 100% (2.5-10 kg BW). According to our simulation, 25 mg ml-1 CXM as a primary bolus and into the prime plus a 5 mg kg-1  h-1 infusion maintain CXM concentrations continuously above 32 µg ml-1 . CONCLUSIONS: The routine dosing regimen provided was sufficient for prophylaxis, but continuous dosing can provide a higher percentage of ƒT > MIC.


Assuntos
Antibacterianos/farmacocinética , Antibioticoprofilaxia/métodos , Ponte Cardiopulmonar/efeitos adversos , Cefuroxima/farmacocinética , Infecção da Ferida Cirúrgica/prevenção & controle , Antibacterianos/administração & dosagem , Antibacterianos/análise , Cefuroxima/administração & dosagem , Cefuroxima/análise , Cromatografia Líquida de Alta Pressão , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Infusões Intravenosas , Masculino , Taxa de Depuração Metabólica , Testes de Sensibilidade Microbiana , Modelos Biológicos , Assistência Perioperatória/métodos , Infecção da Ferida Cirúrgica/etiologia
6.
Ecotoxicol Environ Saf ; 147: 49-54, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28826030

RESUMO

In this study a new calix[4]arene triazole 5 was successfully synthesized using click reaction and characterized through UV-visible, FT-IR, 1H NMR spectroscopes and Mass Spectrometry. The supramolecular interaction of compound 5 towards commonly used drugs has been carried out using UV-Visible spectroscopy. The supramolecule 5 showed characteristic enhancement in the absorbance intensity after mixing with Cefuroxime at pH (2-12). Compound 5 displayed considerably good interactions with cefuroxime in the presence of other drugs. Compound 5 exhibits linear relationship with cefuroxime concentration in the range of (10-80µM) with regression value of 0.9954. The standard deviation for 50µM Cefuroxime was found to be 0.01 and the limit of detection for cefuroxime was calculated to be 2µM. Job's plot experiments showed 1:1 (5: cefuroxime) binding stoichiometry between compound 5 and cefuroxime. Supramolecule 5 displayed fairly good spectrophotometric recognition of Cefuroxime in human blood plasma and tap water thus showing that the ingredients of tap water and plasma sample was inert in the recognition of cefuroxime.


Assuntos
Calixarenos/química , Cefuroxima/sangue , Água Potável/química , Fenóis/química , Triazóis/síntese química , Poluentes Químicos da Água/sangue , Cefuroxima/análise , Humanos , Técnicas In Vitro , Limite de Detecção , Espectroscopia de Ressonância Magnética , Plasma/química , Espectroscopia de Infravermelho com Transformada de Fourier , Triazóis/química , Poluentes Químicos da Água/análise
7.
Biomed Chromatogr ; 28(9): 1199-204, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24519907

RESUMO

Cefuroxime lysine is a new second-generation cephalosporins, which can penetrate the blood-brain barrier to cure the meningitis. In order to investigate its acute toxicokinetic study after intraperitoneal injection of 675 mg/kg cefuroxime lysine, a sensitive and clean ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method for the determination of cefuroxime lysine in microdialysate samples was developed and validated, which was compared with UFLC-UV as a reference method. Chromatographic separation was performed on a Shim-pack XR-ODS C18 column (75 × 3.0 mm, 2.2 µm), with an isocratic elution of 0.1% formic acid in acetonitrile-0.1% formic acid in water (45:55, v/v) for LC-MS and acetonitrile-20 mm potassium dihydrogen phosphate (pH 3.0,20:80, v/v) for LC-UV. The lower limit of detection was 0.01 µg/mL for LC-MS and 0.1 µg/mL for LC-UV method, with the same corresponding linearity range of 0.1-50 µg/mL. The intra- and inter-day precisions (relative standard deviation) for both methods were from 1.1 to 8.9%, while the accuracy was all within ±10.9%. The results of both methods were finally compared using paired t-test; the results indicated that the concentrations measured by the two methods correlated significantly (p < 0.05), which suggested that the two methods based on LC-MS and LC-UV were suitable for the acute toxicokinetic study.


Assuntos
Química Encefálica , Cefuroxima/análogos & derivados , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Cefuroxima/análise , Cefuroxima/farmacocinética , Injeções Intraperitoneais , Limite de Detecção , Modelos Lineares , Masculino , Microdiálise , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta , Toxicocinética
8.
Artigo em Inglês | MEDLINE | ID: mdl-38815354

RESUMO

After a revision surgery, approximately 1-2 % of patients will develop a periprosthetic joint infection (PJI). During the revision surgery, the infected prosthesis is removed, a debridement is performed and a new or temporary spacer is placed. Additionally, patients are treated with antibiotics during and after the surgery. Adequate exposure of the administered antibiotic to the pathogen is of crucial importance during the treatment of any infection. Inadequately low concentrations are associated with an increase in antibiotic resistance, antibiotic related side effects, treatment failures and prolonged infections. While high concentrations may lead to serious adverse events and potential lasting damage. Despite the importance of optimal dosing, there is a lack of knowledge with respect to the correlation between the plasma concentrations and target site concentrations of the antibiotics. Two of the commonly administered antimicrobial agents during the arthroplasty exchange are cefuroxime and flucloxacillin. Therefore, an accurate, specific, and sensitive quantification method is required in order to assess pharmacokinetics of cefuroxime and flucloxacillin in synovial tissue and bone. The aim of this study is to develop and validate a quantification method for the measurement of cefuroxime and flucloxacillin in human synovial tissue and bone using the UPC2-MS/MS conform Food and Drug Administration guidelines. The method was found linear for both compounds in both matrices (r2 > 0.990) from 1 µg/g to 20 µg/g, except for cefuroxime in bone, which was validated from 1 µg/g to 15 µg/g. We developed and validated a quantification method for cefuroxime and flucloxacillin in synovial tissue and bone using a simple sample preparation and a short analysis run time of 5.0 min, which has been already successfully applied in a clinical study. To our knowledge, no methods have been described earlier for the simultaneous quantification of cefuroxime and flucloxacillin in synovial tissue and bone.


Assuntos
Cefuroxima , Floxacilina , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cefuroxima/análise , Cefuroxima/farmacocinética , Cefuroxima/sangue , Cromatografia Líquida de Alta Pressão/métodos , Modelos Lineares , Reprodutibilidade dos Testes , Floxacilina/análise , Floxacilina/farmacocinética , Floxacilina/química , Antibacterianos/análise , Antibacterianos/sangue , Antibacterianos/farmacocinética , Osso e Ossos/química , Osso e Ossos/metabolismo , Membrana Sinovial/química , Membrana Sinovial/metabolismo , Limite de Detecção
9.
J Oral Maxillofac Surg ; 70(6): 1398-403, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22459228

RESUMO

PURPOSE: To investigate the penetration of cefuroxime into the parotid saliva after short-term intravenous administration in patients undergoing various maxillofacial surgical procedures. PATIENTS AND METHODS: A total of 12 patients, 10 males and 2 females, with a mean age of 41 ± 21.2 years, participated in the present study. Each patient received 1.5 g of intravenous cefuroxime every 8 hours. Blood and parotid saliva samples were collected concomitantly, on the third day of therapy, just before the infusion of the first morning dose, and 0.5 hour after its end. All samples were analyzed using high-performance liquid chromatography. RESULTS: The cefuroxime concentration in plasma and saliva before infusion was 2.08 ± 1.05 mg/L and 0.46 ± 0.33 mg/L, respectively. At 30 minutes after the end of infusion, the corresponding concentrations were 55.54 ± 20.24 mg/L and 14.50 ± 7.85 mg/L. The saliva/plasma ratio was 0.25 ± 0.18 before and 0.26 ± 0.12 after the infusion. CONCLUSIONS: Cefuroxime is excreted in saliva in high levels shortly after infusion but is detected in far lower levels 8 hours after infusion. Taking into consideration the minimum inhibitory concentration values of common pathogens, we have concluded that the saliva concentrations of the drug are sufficient against some, but not all, pathogens involved in the oral-maxillofacial area.


Assuntos
Antibacterianos/farmacocinética , Cefuroxima/farmacocinética , Procedimentos Cirúrgicos Bucais , Glândula Parótida/metabolismo , Saliva/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/administração & dosagem , Antibacterianos/análise , Antibacterianos/sangue , Cefuroxima/administração & dosagem , Cefuroxima/análise , Cefuroxima/sangue , Cromatografia Líquida de Alta Pressão , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Infusões Intravenosas , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Boca/microbiologia , Estudos Prospectivos , Adulto Jovem
10.
Artigo em Inglês | MEDLINE | ID: mdl-33545501

RESUMO

BACKGROUND: This study aimed to develop a sensitive, accurate method for simultaneously quantifying cefuroxime and clindamycin in human serum, lumbar anulus fibrosus and nucleus pulposus. METHODS: Cefuroxime and clindamycin were quantified using ultra high-performance liquid chromatography-electrospray ionization tandem mass spectrometry in multiple-reaction-monitoring mode on a triple-quadrupole AB Qtrap 5500 system in positive ion mode. Internal standards were D3-cefuroxime and D3,13C-clindamycin. Samples were pretreated by precipitating total protein. RESULTS: The method showed high sensitivity and good linearity over broad calibration ranges from 100 to 100 000 ng/mL for cefuroxime and 10 to 10 000 ng/mL for clindamycin in serum, and from 10 to 10 000 ng/mL for cefuroxime and 1 to 1 000 ng/mL for clindamycin in lumbar nucleus pulposus. In all sample types, correlation coefficients were greater than 0.99, intra- and inter-day precision (relative standard deviation) was less than 15%, and accuracy (relative error) was within 14% for both analytes. This method was effective at quantifying penetration of cefuroxime and clindamycin in patients undergoing oblique lumbar interbody fusion surgery. CONCLUSIONS: A very sensitive, specific method for simultaneous detection of cefuroxime and clindamycin has been developed for human lumbar anulus fibrosus, nucleus pulposus and serum samples.


Assuntos
Anel Fibroso/química , Cefuroxima/análise , Cromatografia Líquida de Alta Pressão/métodos , Clindamicina/análise , Núcleo Pulposo/química , Anel Fibroso/metabolismo , Cefuroxima/sangue , Cefuroxima/farmacocinética , Clindamicina/sangue , Clindamicina/farmacocinética , Humanos , Modelos Lineares , Região Lombossacral , Núcleo Pulposo/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos
11.
J AOAC Int ; 93(3): 771-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20629374

RESUMO

Conditions for separation and determination of diastereoisomers of cefuroxime axetil by HPTLC on cellulose layers with densitometry were developed. A good separation of the constituents was achieved using a mobile phase composed of 1% aqueous beta-cyclodextrin-methanol (15 + 1, v/v). For detecting spots on the chromatograms, densitometric measurements were used at 285 nm. The method is characterized by high sensitivity; the LOD was 0.04 microg/spot and LOQ was 0.11 microg/spot for both forms of the cefuroxime axetil diastereoisomers. For the individual diastereoisomers, high recovery values from 96.63 to 104.16% were obtained. Identification of the diastereoisomers was performed by 1H-NMR spectrometric analysis.


Assuntos
Antibacterianos/análise , Cefuroxima/análogos & derivados , Cromatografia em Camada Fina/métodos , Cefuroxima/análise , Cefuroxima/química , Espectroscopia de Ressonância Magnética , Estereoisomerismo
12.
J Pharm Pharmacol ; 72(3): 364-370, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31858616

RESUMO

OBJECTIVES: To reduce the incidence of peri- or postoperative infections in orthopaedic surgery, patients are prophylactically treated with antibiotics. Here, we wanted to know whether effective bone and intervertebral disc concentrations of cefuroxime are reached. METHODS: Patients undergoing surgery of hip (N = 40; 62.5% male) or spine (N = 40; 55% male) were pretreated with 1.5 g of the second-generation cephalosporin cefuroxime before surgery. We studied plasma population kinetics and bone and intervertebral disc (C5/6 till L5/S1) concentrations of cefuroxime using high-performance liquid chromatography. KEY FINDINGS: The plasma kinetics of cefuroxime in 80 patients was analysed using a population approach. The clearance amounted to 7.86 l/h. The peripheral and central volumes of distribution were estimated as 8.45 and 10.4 l, respectively. The concentrations in hip samples amounted to 9.8 ± 0.6 µg/g in cancellous bone and 8.9 ± 0.8 µg/g in cortical bone. Cefuroxime concentrations in vertebral bone and intervertebral discs were calculated as 9.6 ± 1.3 and 8.9 ± 1.1 µg/g, respectively. CONCLUSION: Even if a majority of patients undergoing hip or spine surgery probably achieved adequate concentrations of cefuroxime, not all patients reached bone concentrations of cefuroxime above a recommended breakpoint for susceptible germs at the time of surgery.


Assuntos
Antibacterianos/farmacocinética , Osso e Ossos/metabolismo , Cefuroxima/farmacocinética , Quadril , Procedimentos Ortopédicos , Adulto , Idoso , Antibacterianos/análise , Antibacterianos/sangue , Artroplastia do Joelho , Cefuroxima/análise , Cefuroxima/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Coluna Vertebral
13.
Int Urol Nephrol ; 52(4): 645-654, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31832876

RESUMO

OBJECTIVE: This study sought to evaluate the antibacterial effect of fosfomycin tromethamine (FT) on the bacteria inside urinary infection stones. METHODS: The internal structures of urinary stones were observed via scanning electron microscopy to verify the presence of internal bacteria. We randomly assigned equal numbers of patients with kidney stones who met the inclusion criteria into two groups in a prospective study and treated them with different perioperative antibiotics. One group (experimental group) was treated with FT, and the other (control group) was treated with cefuroxime sodium. All stone specimens were collected via percutaneous nephrolithotomy (PCNL). The primary infection stones were screened via a stone component analysis, 30 cases in the experimental group and 31 cases in the control group. High-performance liquid chromatography (HPLC)-mass spectrometry was used to measure the drug concentration inside the stones, the bacterial count was calculated via stone culture, and the clinical infection index were monitored for between-group comparisons. RESULTS: Compared with the control group, the experimental group had a higher internal drug concentration, a higher drug sensitivity against various pathogenic bacteria, a lower bacterial colony count in the stone culture, and a lower incidence of postoperative clinical infection. CONCLUSIONS: FT is more effective than cefuroxime, which is commonly used during the perioperative period of urinary stones, and exerts a high antibacterial effect on these internal bacteria, and effectively reduces the probability of infection and sepsis after urinary stone surgery. FT can be used as an antibiotic during the perioperative period of urinary stones.


Assuntos
Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Bactérias/efeitos dos fármacos , Fosfomicina/uso terapêutico , Cálculos Renais/química , Cálculos Renais/microbiologia , Adulto , Idoso , Antibacterianos/análise , Antibacterianos/farmacologia , Bactérias/crescimento & desenvolvimento , Bactérias/isolamento & purificação , Cefuroxima/análise , Cefuroxima/farmacologia , Cefuroxima/uso terapêutico , Contagem de Colônia Microbiana , Feminino , Febre/etiologia , Febre/prevenção & controle , Fosfomicina/análise , Fosfomicina/farmacologia , Humanos , Cálculos Renais/cirurgia , Cálculos Renais/ultraestrutura , Masculino , Pessoa de Meia-Idade , Nefrolitotomia Percutânea/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Sepse/etiologia , Sepse/prevenção & controle
14.
Pharm Dev Technol ; 14(5): 485-91, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19743947

RESUMO

In vitro and in vivo antibacterial activities on the Staphylococcus aureus and Escherichia coli of the amorphous cefuroxime axetil (CFA) ultrafine particles prepared by HGAP method were investigated in this paper. The conventional sprayed CFA particles were studied as the control group. XRD, SEM, BET tests were performed to investigate the morphology changes of the samples before and after sterile. The in vitro dissolution test, minimal inhibitory concentrations (MIC) and the in vivo experiment on mice were explored. The results demonstrated that: (i) The structure, morphology and amorphous form of the particles could be affected during steam sterile process; (ii) CFA particles with different morphologies showed varied antibacterial activities; and (iii) the in vitro and in vivo antibacterial activities of the ultrafine particles prepared by HGAP is markedly stronger than that of the conventional sprayed amorphous particles.


Assuntos
Antibacterianos/análise , Antibacterianos/uso terapêutico , Cefuroxima/análogos & derivados , Infecções por Escherichia coli/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Animais , Antibacterianos/farmacologia , Cefuroxima/análise , Cefuroxima/farmacologia , Cefuroxima/uso terapêutico , Precipitação Química , Composição de Medicamentos , Escherichia coli/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos ICR , Tamanho da Partícula , Solubilidade , Staphylococcus aureus/efeitos dos fármacos , Difração de Raios X
15.
J Am Chem Soc ; 130(20): 6351-61, 2008 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-18429614

RESUMO

The fluorescein-labeled E166C mutant of the PenPC beta-lactamase (E166Cf) represents a successful model in the construction of "switch-on" fluorescent biosensors from nonallosteric proteins (Chan P.-H. et al.; J. Am Chem. Soc., 2004, 126, 4074). This paper focuses on the study of the biosensing mechanism by which the E166Cf biosensor changes its fluorescence upon beta-lactam binding and hydrolysis. Mass spectrometric and stopped-flow fluorescence studies of E166Cf with cefuroxime, penicillin G, and 6-aminopenicillanic acid reveal that the formation of enzyme-substrate complex enhances the fluorescence of E166Cf, and the subsequent regeneration of the free enzyme restores the weak fluorescence of E166Cf. Molecular modeling studies of E166Cf with penicillin G show that the fluorescein label is likely to share a common space with the beta-lactam and thiazolidine rings of the antibiotic in the active site. This spatial clash appears to cause the fluorescein label to move from the active site to the external aqueous environment upon substrate binding and hence experience higher water exposure. Steady-state fluorescence measurements indicate that the fluorescence of E166Cf can be enhanced by 6-aminopenicillanic acid, which consists of the beta-lactam and thiazolidine rings only. Thermal denaturation experiments of the wild-type enzyme, E166C, and E166Cf reveal that the E166C mutation is likely to increase the flexibility of the Omega-loop. This "modified" structural property might compensate for the possible steric effect of the fluorescein label on substrate binding.


Assuntos
Antibacterianos/análise , Técnicas Biossensoriais/métodos , Fluoresceínas/química , Corantes Fluorescentes/química , beta-Lactamases/química , beta-Lactamas/análise , Antibacterianos/química , Cefuroxima/análise , Cefuroxima/química , Dicroísmo Circular , Simulação por Computador , Cinética , Espectrometria de Massas , Modelos Moleculares , Ácido Penicilânico/análogos & derivados , Ácido Penicilânico/análise , Ácido Penicilânico/química , Penicilina G/análise , Penicilina G/química , Desnaturação Proteica , Espectrometria de Fluorescência/métodos , beta-Lactamases/metabolismo , beta-Lactamas/química
16.
Guang Pu Xue Yu Guang Pu Fen Xi ; 28(9): 2139-43, 2008 Sep.
Artigo em Zh | MEDLINE | ID: mdl-19093579

RESUMO

Under different temperatures and physiological conditions, with cefuroxime axetil concentrations in the range of 1.959 X 10(-6) to 13.71 X 10(-6) mol x L(-1), and bovine serum albumin (BSA) concentrations at 2.0 X 10(-6) mol x L(-1), the interaction between cefuroxime axetil and BSA was studied by fluorescence spectroscopy, three-dimensional fluorescence spectrum, synchronous fluorescence spectrum and UV-Vis absorption spectroscopy. After analyzing and processing the fluorescence quenching data at different temperatures according to Sterm-Volmer equation, Lineweaver-Burk equation and thermodynamic equation, the average value of the apparent binding constant (K(LB): 3.907 X 10(6) L x mol(-1)), and thermodynamics parameters (enthalpy change delta H: -13.43 kJ x mol(-1), entropy change delta S: 81.90 J x K(-1) and standard Gibbs free energy change delta G0: -38.34 kJ x mol(-1)) were calculated, and the amounts of binding sites (n: 1.042)were measured. The fluorescence quenching mechanism of BSA after cefuroxime axetil was added was discussed. BSA was bound with cefuroxime axetil and formed a new compound. The quenching belonged to static fluorescence quenching. The thermodynamic parameters agree with delta H approximately 0, delta S > 0 and delta G0 < 0, and the binding reaction is mainly entropy-driven and electro-static interaction force plays a major role in the reaction. The maximum emission wavelength of Tyr and Trp had an obvious red shift in the synchronous fluorescence spectra, the fluorescence emission wavelength of two peaks had a blue shift in the three-dimensional fluorescence spectrum of BSA in the presence of cefuroxime axetil and the maximum absorbtion wavelenghs of three systems in the UV-Vis absorption spectra were obviously different. These showed that the changes in the micro-environment of Tyr and Trp and demonstrated that the conformation of BSA changed as cefuroxime axetil had been added. This provides important information for discussing the configuration modification of BSA because of the added cefuroxime axetil, and for elucidating the pharmacological effects of cefuroxime axetil and biological effects in the organism.


Assuntos
Antibacterianos/química , Cefuroxima/análogos & derivados , Soroalbumina Bovina/química , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta , Termodinâmica , Absorção , Animais , Antibacterianos/análise , Bovinos , Cefuroxima/análise , Cefuroxima/química , Entropia , Estrutura Molecular , Ligação Proteica , Conformação Proteica , Soroalbumina Bovina/análise , Temperatura
17.
J Pharm Sci ; 107(8): 2259-2265, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29715477

RESUMO

Concentrations in the interstitial tissue space are of clinical interest for many antibiotics and can be directly measured by microdialysis. Quantitative microdialysis strongly depends on reliable recovery estimates obtained from a suitable calibrator. Cefazolin (CFZ) is frequently used as a prophylactic antibiotic to prevent surgical site infections. This study aimed to develop a reliable and rapid calibration technique for CFZ microdialysis using cefuroxime (CFR) as a calibrator, which is applied simultaneously in the opposite direction via retrodialysis. Liquid chromatography-tandem mass spectrometry method was used for the measurement of both CFZ and CFR in microdialysate. Results from in vitro microdialysis experiments confirmed that CFR does not interfere with physicochemical properties of CFZ, and the loss of CFR is proportional to the gain of CFZ in microdialysis studies. Therefore, the validated bioanalytical assay is suitable to be applied in clinical microdialysis study of CFZ where microdialysis probes are simultaneously calibrated by retrodialysis of CFR. This approach shortens the overall sampling time of in vivo microdialysis studies significantly since calibration and sampling can be performed simultaneously and not in sequence as usually done. It also eliminates the necessary washout period if probe calibration is carried out before the actual sampling time.


Assuntos
Antibacterianos/farmacocinética , Cefazolina/farmacocinética , Microdiálise/métodos , Antibacterianos/análise , Calibragem , Cefazolina/análise , Cefuroxima/análise , Cefuroxima/farmacocinética , Cromatografia Líquida/métodos , Humanos , Limite de Detecção , Espectrometria de Massas em Tandem/métodos
18.
Am J Trop Med Hyg ; 98(1): 344-348, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29141717

RESUMO

Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.


Assuntos
Anti-Infecciosos/normas , Cromatografia em Camada Fina , Amoxicilina/análise , Amoxicilina/normas , Anti-Infecciosos/análise , Azitromicina/análise , Azitromicina/normas , Cefuroxima/análise , Cefuroxima/normas , Cromatografia Líquida de Alta Pressão , Cromatografia em Camada Fina/métodos , Reações Falso-Negativas , Reações Falso-Positivas , Levofloxacino/análise , Levofloxacino/normas , Metronidazol/análise , Metronidazol/normas , Controle de Qualidade , Reprodutibilidade dos Testes
19.
J AOAC Int ; 90(2): 405-13, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17474511

RESUMO

Column liquid chromatography (LC) and thin-layer chromatography (TLC)-densitometry methods are described for simultaneous determination of acediasulfone (Ace) and cinchocaine (Cinco). In the LC method, the separation and quantitation of the 2 drugs was achieved on a Zorbax C8 column (5 microm, 150 x 4.6 mm id) using a mobile phase composed of methanol-phosphate buffer, pH 2.5 (66 + 34, v/v), at a flow rate of 1 mL/min and ultraviolet detection at 300 and 327 nm for Ace and Cinco, respectively. The method showed linearity over concentration ranges of 20-200 and 45-685 microg/mL, respectively. In the TLC-densitometry method, a mobile phase composed of methanol-tetrahydrofuran-acetic acid (45 + 5 + 0.5, v/v/v) was used for the separation of the 2 drugs. The linearity range was 0.5-4 and 2-9 microg/spot, respectively. In addition, stability indicating TLC-densitometry method has been developed for determination of cefuroxime sodium in the presence of 5-70% of its known hydrolytic degradation products. The mobile phase butanol-methanol-tetrahydrofuran-concentrated ammonium hydroxide (50 + 50 + 50' + 5, v/v/v/v) was used. The concentration range was 2-10 microg/spot. The optimized methods proved to be specific and accurate for the analysis of the cited drugs in laboratory-prepared mixtures and dosage forms. The obtained results agreed statistically with those obtained by the reference methods.


Assuntos
Cefuroxima/análise , Técnicas de Química Analítica/métodos , Cromatografia em Camada Fina/métodos , Dibucaína/análise , Sulfonas/análise , Hidróxido de Amônia , Cromatografia Líquida/métodos , Densitometria/métodos , Formas de Dosagem , Estabilidade de Medicamentos , Hidróxidos/química , Modelos Químicos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta , Sulfonas/química
20.
Drug Test Anal ; 9(7): 1062-1072, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27714984

RESUMO

The use of cephalosporins during breast feeding raises several issues, including the risk of drug exposure through breast milk for the infant. In this paper, a hydrophilic interaction liquid chromatography/positive ion electrospray mass spectrometric assay (HILIC/ESI-MS) was developed for the quantitation of cefuroxime, cefoxitin, and cefazolin in breast milk and human plasma. The assay was based on the use of small sample size, 25 µL of biological samples, following acetonitrile precipitation of proteins and filtration that enabled injection into the HILIC/ESI-MS system. All analytes and the internal standard, alfuzosin, were separated by using a ZIC®-HILIC analytical column (150.0 × 2.1 mm i.d., particle size 3.5 µm, 200 Å) with isocratic elution. The mobile phase was composed of a 6% 12.5 mM ammonium acetate water solution in acetonitrile and pumped at a flow rate of 0.25 mL min-1 . The assay was linear over a concentration range of 0.2 to 5 µg mL-1 and 0.4 to 20 µg mL-1 for all the analytes in breast milk and in human plasma, respectively. Intermediate precision was found to be less than 4.2% over the tested concentration ranges. A run time of less than 12 min for each sample made it possible to analyze a large number of biological samples per day. The method is the first reported application of HILIC in the analysis of antibiotics in breast milk and human plasma and it can be used to support a wide range of clinical studies. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Antibacterianos/análise , Antibacterianos/sangue , Leite Humano/química , Espectrometria de Massas por Ionização por Electrospray/métodos , beta-Lactamas/análise , beta-Lactamas/sangue , Cefazolina/análise , Cefazolina/sangue , Cefoxitina/análise , Cefoxitina/sangue , Cefuroxima/análise , Cefuroxima/sangue , Cromatografia Líquida/métodos , Feminino , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA