Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.573
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 96(11): 4639-4646, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501258

RESUMO

Multicomponent reactions offer efficient and environmentally friendly strategies for preparing monoliths suitable for applications in analytical chemistry. In the described study, a multicomponent reaction was utilized for the one-pot miniaturized preparation of a poly(propargyl amine) polymer inside commercial silica-lined PEEK tubing. The reaction involved only small amounts of reagents and was characterized by atom economy. The resulting monolithic column was incorporated into an autosampler system for the online extraction and cleanup of ß-estradiol from human serum. Sample pretreatment was simplified to a simple dilution with methanol and centrifugation to remove proteins. The resulting platform included LC-MS analysis in multiple reaction monitoring for quantitative analysis of ß-estradiol. The method was validated in serum, demonstrating practical applicability for the monitoring of fertile women. Recoveries were above 94%, and LOD and LOQ values at 0.008 and 0.18 ng mL-1, respectively. The developed platform proved to be competitive with previous methods for solid-phase microextraction of ß-estradiol in serum, with comparable recovery and sensitivity but with the advantage of nearly complete automation. The environmental impact of the process was evaluated as acceptable due to the miniaturization of the monolith synthesis and the automation of extraction. The drawback associated with the LC-MS technique can be reduced by the inclusion of additional analytes in a single investigation. The work demonstrates that multicomponent reactions are versatile, economical, and possibly a green methodology for producing reversed-phase and mixed-mode sorbents, enabling miniaturization of the entire analytical procedure from the preparation of extraction sorbents to analysis.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Humanos , Feminino , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Estradiol , Microextração em Fase Sólida/métodos , Extração em Fase Sólida/métodos
2.
Anal Chem ; 96(8): 3561-3568, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38372135

RESUMO

Covalent organic frameworks (COFs) are attractive adsorbents for sample pretreatment due to their unique structure and properties. However, the selectivity of COFs for the extraction of hazardous compounds is still limited due to the lack of specific interactions between COFs and targets. Herein, we report a pore size adjustment strategy for room-temperature synthesis of molecularly imprinted COF (MICOF) for selective extraction of zearalenone (ZEN) in complex food samples. The three-dimensional building block tetra(4-aminophenyl) methane was used as a functional monomer, while dialdehyde monomers with different numbers of benzene ring were used to adjust the pore size of MICOF to match with the size of ZEN molecules. The prepared MICOF gave the largest adsorption capacity of 177.2 mg g-1 and the highest imprinting factor of 10.1 for ZEN so far. MICOF was used as the adsorbent for dispersed solid-phase extraction in combination with high-performance liquid chromatography for the determination of trace ZEN in cereals. The high selectivity of the developed method allows simple aqueous standard calibration for the matrix effect-free determination of ZEN in food samples. The limit of detection and the recoveries of the developed method were 0.21 µg kg-1 and 93.7-101.4%, respectively. The precision for the determination of ZEN was less than 3.8% (RSD, n = 6). The developed method is promising for the selective determination of ZEN in complex matrices.


Assuntos
Estruturas Metalorgânicas , Nanosferas , Zearalenona , Estruturas Metalorgânicas/química , Zearalenona/análise , Grão Comestível/química , Temperatura , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Adsorção
3.
Nat Methods ; 18(7): 733-746, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33972782

RESUMO

Ultra-high-performance liquid chromatography high-resolution mass spectrometry (UHPLC-HRMS) variants currently represent the best tools to tackle the challenges of complexity and lack of comprehensive coverage of the metabolome. UHPLC offers flexible and efficient separation coupled with high-sensitivity detection via HRMS, allowing for the detection and identification of a broad range of metabolites. Here we discuss current common strategies for UHPLC-HRMS-based metabolomics, with a focus on expanding metabolome coverage.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Metabolômica/métodos , Cromatografia Líquida de Alta Pressão/instrumentação , Espectrometria de Mobilidade Iônica/instrumentação , Espectrometria de Mobilidade Iônica/métodos , Espectroscopia de Ressonância Magnética , Extração em Fase Sólida/métodos , Espectrometria de Massas por Ionização por Electrospray
4.
Chem Res Toxicol ; 37(1): 33-41, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-38078760

RESUMO

Since the focus in regulatory toxicology has drifted toward the identification of endocrine disruptors, the improvement in determination of alterations in the thyroid hormone system has become more important. THs are involved in several molecular processes important for a proper pre- and postnatal development so that disturbances can inter alia lead to incorrect brain maturation and/or disturbed metabolic processes (thermogenesis or lipolysis). In this publication, a new automated online solid-phase extraction (SPE)-liquid chromatography (LC)-tandem mass spectrometry (MS/MS, xLC-MS/MS) is introduced which simultaneously analyzes total T4, T3, rT3, T2, and T1. Method validation parameters are presented, and the method was positively verified by analyzing control and PTU-treated rat plasma samples (time points day 7, 14, and 28) for their total TH content. The obtained results were compared to published results by using a radioimmunoassay method. The automated SPE system ensures a consistent unified sample preparation, and this method overall showed sufficient specificity and accuracy to detect the given analytes in rat plasma. For the preparation of 50 µL of rat plasma, the following LOQs were established: 0.020 nM for T1, 0.029 nM for T2, 0.023 nM for rT3 and T3, and 3.22 nM for T4. This method is suitable to assess the identification of mechanisms leading to adverse effects, such as disturbed TH metabolism and regulation.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Ratos , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Hormônios Tireóideos , Extração em Fase Sólida/métodos , Reprodutibilidade dos Testes
5.
Rapid Commun Mass Spectrom ; 38(5): e9684, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38355878

RESUMO

RATIONALE: Personal care product chemicals (PCPCs) are the chemicals used in personal care products. Many of them are endocrine disruptors and have potential adverse effects on humans. The concentrations of PCPCs in urine are the main biomarker for assessing human exposure. METHODS: A method was developed for the simultaneous determination of 14 PCPCs in human urine using dispersive liquid-liquid extraction combined with ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). RESULTS: Compared with liquid-liquid extraction, this method had the advantages of time efficiency, sensitivity, and limited organic solvent consumption. It produced good linearity (0.9965-0.9996), limits of detection (2.82-36.36 pg mL-1 ), limits of quantitation (9.39-121.08 pg mL-1 ), matrix effect (-0.90%-2.55%), intra-day precision (relative standard deviations [RSDs] <15%), and inter-day precision (RSDs <19.9%). The method had satisfactory relative recovery at three concentration levels. CONCLUSIONS: A rapid method was developed for the simultaneous quantification of 14 PCPCs in human urine. The practicability of the method was verified with 21 urine from university students. It is expected that this method will provide a powerful reference for the assessment of exposure to PCPCs in large populations.


Assuntos
Disruptores Endócrinos , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Extração Líquido-Líquido , Disruptores Endócrinos/análise , Biomarcadores/análise , Extração em Fase Sólida/métodos
6.
Rapid Commun Mass Spectrom ; 38(6): e9703, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38356091

RESUMO

RATIONALE: Secondary hypertension is often caused by activation of complex multi-organ endocrine systems, while renin activity indicated by angiotensins (Angs), aldosterone (ALD) and cortisol (COR) in such systems are generally accepted as its diagnostic markers. As antibody-based methods cannot offer comparable quantification for these biomarkers, a liquid chromatography (LC)-tandem mass spectrometry (MS/MS)-based approach was developed to quantify them simultaneously and accurately. METHODS: Five different beads for magnetic solid-phase extraction (MSPE) were evaluated towards their enrichment efficiency for these biomarkers. An LC system with optimized elution gradient and a triple-quadrupole MS with tuned parameters were coupled to quantitatively monitor the extracted analytes. The method performance was further examined such as linearity, precision, stability, recovery rate and matrix effect. Based on the developed method, the abundance of Ang II, ALD and COR in plasma was measured and the quantification was compared with that derived from commercial ELISA kits. RESULTS: As compared with other MSPEs, Angs, ALD and COR were highly enriched by the HLB magnetic beads with satisfactory recoveries. These analytes were simultaneously quantified by LC/MS/MS and all the method parameters for quantification were well matched with the requirements of clinical testing. Comparison of the quantitative results derived from ELISA and LC/MS/MS exhibited that the two methods offered basically comparable values with Pearson r values at 0.896, 0.895 and 0.835, respectively. The stability test for plasma Angs at room temperature indicated that the abundance of Ang II was relatively stable within 3 h, whereas that of Ang I and Ang 1-7 was time-dependently changed. CONCLUSIONS: Coupling of HLB beads and LC/MS/MS thus enables simultaneous quantification of a set of biomarkers related to secondary hypertension.


Assuntos
Hipertensão , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Biomarcadores , Fenômenos Magnéticos , Cromatografia Líquida de Alta Pressão
7.
Rapid Commun Mass Spectrom ; 38(17): e9856, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38945695

RESUMO

RATIONALE: To uphold the integrity of horseracing and equestrian sports, it is critical for an equine doping control laboratory to develop a comprehensive screening method to cover a wide range of target substances at the required detection levels in equine urine. METHODS: The procedure involved the enzymatic hydrolysis of 3 mL urine samples followed by solid-phase extraction using HF Bond Elut C18 cartridge. The resulting extracts were then separated on a C18 reversed-phase column and analyzed using liquid chromatography/high-resolution mass spectrometry (LC/HRMS) in both electrospray ionization positive and negative modes in two separate injections. The analytical data were obtained in full scan and product ion scan (PIS) modes in an 11 min LC run. RESULTS: The method can detect 1011 compounds (in both positive and negative ion modes). Over 95% of the target compounds have limits of detections (LODs) ≤10 ng/mL, and more than 50% of the LODs are ≤0.5 ng/mL. The lowest LOD can reach down to 0.01 ng/mL. The applicability of the method was demonstrated by the successful detection of prohibited substances in overseas and domestic equine urine samples. CONCLUSIONS: We have successfully developed a regular screening method for equine urine samples that can detect more than 1000 compounds at sub-ppb levels in both positive and negative ion modes with full scan and PIS using LC/HRMS. Furthermore, this method can theoretically be expanded to accommodate an unlimited number of prohibited substances in full-scan mode.


Assuntos
Dopagem Esportivo , Limite de Detecção , Animais , Cavalos/urina , Dopagem Esportivo/prevenção & controle , Cromatografia Líquida/métodos , Detecção do Abuso de Substâncias/métodos , Detecção do Abuso de Substâncias/veterinária , Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Reprodutibilidade dos Testes
8.
Int J Legal Med ; 138(3): 721-730, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37968478

RESUMO

In a forensic scenario, if biological stains are found in very small quantities, these are usually collected for DNA analyses, considered essential for the forensic investigation and thus excluding possible investigations by other forensic disciplines as forensic toxicology. We developed an experimental study to evaluate the feasibility of analyzing DNA extraction residues obtained from DNA extraction procedures to perform toxicological analysis, with the aim to extract both genetic and toxicological information without affecting or compromising the genetic sample and/or DNA extraction. DNA extraction from four blood samples (fortified with 5 molecules of interest with a final concentrations of 1 µg/mL, 100 ng/mL, 10 ng/mL and 5 ng/mL, respectively) were analyzed with QIAGEN QIAmp® DNA Mini kit. Three waste residues collected from the DNA extraction were analyzed for the toxicological investigation via Solid-Phase Extraction and High-Performance Liquid Chromatography-Tandem Mass Spectrometry analyses (Thermo Scientific™ TSQ Fortis™ II Triple-Quadrupole Mass Spectrometer). The analytical investigation revealed that our analytes of interest were detected in two different residues of the DNA extraction procedure, allowing both genetic and toxicological analyses without affecting the DNA identification. At last, the experimental protocol was applied to a hypothetical case, with encouraging results and allowing the identification of our molecules of interest.


Assuntos
Extração em Fase Sólida , Humanos , Espectrometria de Massas/métodos , Cromatografia Líquida de Alta Pressão/métodos , Toxicologia Forense/métodos , Extração em Fase Sólida/métodos
9.
Analyst ; 149(13): 3673-3680, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38819227

RESUMO

Benzoylurea (BU) insecticides have been widely used for pest control as third-generation insecticides. Considering that their residues in food may cause adverse effects on human health, the upper limits of BUs remaining in food have been set by the administration. Therefore, it is essential to develop a sensitive and efficient analytical method to determine the residues of BUs in food. Stir bar sorptive extraction (SBSE) is a novel sample preparation technique, and stainless steel wire (SSW) is an ideal substrate for an SBSE device. In this work, a novel SBSE device of SSW jacket-free stir bar with a dumbbell shape was designed and prepared. The conjugated microporous polymer CMP-F6, which possesses a porous structure, high hydrophobicity and rich fluorine-containing functional groups, was immobilized on the surface of SSW by the method of polyacrylonitrile glue adhesion. Compared with previous studies, which used SSW as a substrate, the method of etching partial SSW with hydrochloric acid, on the one hand, made the surface of SSW rough and easy to modify the extraction coating, and on the other hand, converted itself into a dumbbell-shaped structure, which is conducive to improving the extraction efficiency and stability of the SBSE device. The method of SBSE-HPLC-UV was established for determining five BUs. Owing to the hydrophobic interaction and F-F interaction between CMP-F6 and analytes, this method showed good extraction efficiency and had good linearity (R2 ≥ 0.9945) and high sensitivity (LODs in the range of 0.1-0.2 ng mL-1). It was used for the analysis of benzoylurea in an apple juice sample, and the recoveries were 74.3-117.9%.


Assuntos
Sucos de Frutas e Vegetais , Polímeros , Aço Inoxidável , Aço Inoxidável/química , Porosidade , Sucos de Frutas e Vegetais/análise , Polímeros/química , Limite de Detecção , Contaminação de Alimentos/análise , Ureia/química , Ureia/análise , Inseticidas/análise , Inseticidas/isolamento & purificação , Inseticidas/química , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Adsorção , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação
10.
Anal Bioanal Chem ; 416(3): 745-757, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37812219

RESUMO

Moenomycin A, an antimicrobial growth promoter widely used as an additive in aquaculture feedstuffs, has been restricted for use in the European Union and China due to its potential risk of promoting resistant strains of pathogenic bacteria and causing residues in aquatic animal products. Although methods for analyzing moenomycin A in feedstuffs have been developed, no established method exists for aquatic matrices. In this study, we present, for the first time, a sensitive and validated high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for the determination of moenomycin A in aquatic animal products. Samples were extracted using methanol and purified with the QuEChERS method employing C18 sorbent. The aliquot was dried under a nitrogen stream, reconstituted with methanol-water solvent, and analyzed by HPLC-MS/MS. The developed method exhibited good linearity (r2 > 0.995) over a wide concentration range (1-100 µg/L) and a low limit of detection (1 µg/kg). Average recoveries ranged between 70 and 110% at spiked concentrations of 1, 50, and 100 µg/kg, with associated intra- and inter-day relative standard deviations of 1.25 to 7.32% (n = 6) and 2.91 to 10.08% (n = 3), for different representative aquatic animal production, respectively. To the best of our knowledge, this is the first reported HPLC-MS/MS method for the quantification of moenomycin A in aquatic animal products. The new approach was effectively employed in the analysis of moenomycin A across various aquatic samples.


Assuntos
Metanol , Espectrometria de Massas em Tandem , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , China , Extração em Fase Sólida/métodos
11.
Anal Bioanal Chem ; 416(10): 2479-2492, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38462592

RESUMO

Bisphenol A (BPA), known for its endocrine-disrupting properties and potential to leach into food products, has led to significant food safety concerns. Therefore, the development of sensitive and selective BPA rapid detection methods is crucial. In this study, molecularly imprinted solid-phase extraction coupled to a colorimetric method was adopted for the smartphone-based determination of BPA. The molecularly imprinted polymer (MIP) was prepared via photopolymerization and used as a selective adsorbent material for SPE columns. The solid-phase extraction (SPE) columns with multiple cycles significantly reduced the extraction time to only 30 min. The developed method demonstrates useful sensitivity for BPA (LOD = 30 ppb). Furthermore, BPA migration from plastic packaging was evaluated under different storage conditions, revealing that microwave treatment for 5 min led to BPA release from polycarbonate packaging in juice and basic solutions. The MIP selective extraction/clean-up and smartphone-based optical sensor were successfully applied to BPA standard solutions and complex food samples (e.g., juice and tap water), resulting in reproducible and selective BPA determination (RSD ≤ 6%, n = 3). This rapid and cost-effective method of producing MIPs for BPA offers a promising solution for fast and low-cost sensing for on-site fresh food analysis.


Assuntos
Impressão Molecular , Fenóis , Impressão Molecular/métodos , Smartphone , Extração em Fase Sólida/métodos , Água , Compostos Benzidrílicos/análise , Polímeros Molecularmente Impressos
12.
Anal Bioanal Chem ; 416(10): 2399-2409, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38393340

RESUMO

According to green analytical chemistry principles, the use of agricultural byproducts as sorbent phases is an interesting topic due to their lignocellulosic origin, as they are biodegradable and inexpensive. To the best of our knowledge, this is the first study in which avocado seed and avocado seed activated carbon are proposed as sustainable sorbents for solid-phase microextraction technologies, which were used to assess the proof of concept. Rotating disk sorptive extraction (RDSE) was used as a model technology and ibuprofen (Ibu) and 1-hydroxy-ibuprofen (1-OH-Ibu) as representative analytes. It was found that activated carbon (AC) prepared at 600 °C with an impregnation ratio (raw material/activating agent (ZnCl2), w/w) of 1:1.2 had better extraction efficiency than other ACs obtained at different temperatures, impregnation ratios, and activating agents (K2CO3). Characterization revealed several differences between natural avocado seed, biochar prepared at 600 °C, and selected AC since the typical functional groups of the natural starting material begin to disappear with pyrolysis and increasing the surface area and pore volume, suggesting that the main interactions between analytes and the sorbent material are pore filling and π-π stacking. By using this AC as the sorbent phase, the optimal extraction conditions in RDSE were as follows: the use of 50 mg of sorbent in the disk, 30 mL of sample volume, pH 4, 90 min of extraction time at a rotation velocity of the disk of 2000 rpm, and methanol as the elution solvent. The extracts were analyzed via gas chromatography coupled to mass spectrometry (GC-MS). The method provided limits of detection of 0.23 and 0.07 µg L-1 and recoveries of 81% and 91% for Ibu and 1-OH-Ibu, respectively. When comparing the extraction efficiency of the selected activated carbon with those provided by Oasis® HLB and C18 in RDSE, nonsignificant differences were observed, indicating that avocado seed activated carbon is a suitable alternative to these commercial materials.


Assuntos
Carvão Vegetal , Persea , Ibuprofeno , Solventes/química , Tecnologia , Extração em Fase Sólida/métodos
13.
Anal Bioanal Chem ; 416(4): 945-957, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38051414

RESUMO

Histamine causes allergic reactions and can serve as an indicator for assessing food quality. This study designed and developed a dispersive micro solid-phase extraction (D-µSPE) method that combined the advantages of dispersive liquid-liquid extraction and solid-phase extraction (SPE). Molecularly imprinted polymers (MIPs) were employed as the solid phase in the D-µSPE method to extract histamine in wine samples. We used microwave energy to significantly reduce the synthesis time, achieving an 11.1-fold shorter synthesis time compared to the conventional MIP synthetic method. Under optimized D-µSPE conditions, our results showed that the dispersive solvent could effectively increase the adsorption performance of MIPs in wine samples by 97.7%. To improve the sensitivity of histamine detection in gas chromatography-mass spectrometry, we employed the microwave-assisted tandem derivatization method to reuse excess derivatization reagents and reduce energy consumption and reaction time. Calibration curves were constructed for wine samples spiked with 0-400 nmol histamine using the standard addition method, resulting in good linearity with a coefficient of determination of 0.999. The intra- and inter-batch relative standard deviations of the slope and intercept were < 0.7% and < 5.3%, respectively. The limits of quantitation and detection were 0.4 nmol and 0.1 nmol, respectively. The developed method was successfully applied to analyze the histamine concentration in 10 commercial wine samples. In addition, the AGREEprep tool was used to evaluate the greenness performance of the developed method, which obtained a higher score than the other reported methods.


Assuntos
Impressão Molecular , Vinho , Vinho/análise , Cromatografia Líquida de Alta Pressão/métodos , Histamina/análise , Polímeros/química , Extração em Fase Sólida/métodos , Impressão Molecular/métodos
14.
Anal Bioanal Chem ; 416(3): 689-700, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37971663

RESUMO

Generic extraction methods for the multi-compound pesticide analysis of food have found their solid place in laboratories. Ethyl acetate and acetonitrile extraction methods have been developed as fast and easy to handle standard multi-compound methods, both feature benefits and limitations. The direct injection to gas chromatography can be impaired by a high burden of coextracted matrix, resulting in deterioration of the chromatographic system and matrix effects, requiring frequent maintenance. Therefore, common clean-up methods, such as dispersive solid-phase extraction, freeze-out of fats, or gel permeation chromatography, have been applied in clean-up. Automated clean-up using micro-solid-phase extraction (µSPE) is a recent development with several demonstrated advantages when employed in the analysis of pesticides and other contaminants in foods extracted with acetonitrile, but it has not yet been evaluated in this application using ethyl acetate for extraction. In this study, an automated procedure using µSPE cartridges was developed and established on an x,y,z robotic sampler for the raw extract clean-up and preparation of diluted samples for injection on a GC-MS/MS system. Validation experiments for 212 pesticides, polychlorinated biphenyls, and polycyclic aromatic hydrocarbons in lettuce, avocado, raspberry, paprika, egg, and liver extracts were performed using µSPE with MgSO4, PSA, C18, and CarbonX. The performance in routine operation is briefly discussed.


Assuntos
Resíduos de Praguicidas , Praguicidas , Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Resíduos de Praguicidas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Acetonitrilas/química
15.
Anal Bioanal Chem ; 416(2): 439-448, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37946037

RESUMO

In the present study, a homemade mixed-mode ion-exchange sorbent based on silica with embedded graphene microparticles is applied for the selective extraction of 2-aminobenzothiazole (NH2BT) followed by determination through liquid chromatography coupled to high-resolution mass spectrometry. The sorbent was evaluated for the solid-phase extraction of NH2BT from environmental water samples (river, effluent wastewater, and influent wastewater), and NH2BT was strongly retained through the selective cation-exchange interactions. Therefore, the inclusion of a clean-up step of 7 mL of methanol provided good selectivity for the extraction of NH2BT. The apparent recoveries obtained for environmental water samples ranged from 62 to 69% and the matrix effect from -1 to -14%. The sorbent was also evaluated in the clean-up step of the organic extract for the extraction of NH2BT from organic extracts of indoor dust samples (10 mL of ethyl acetate from pressurized liquid extraction) and fish (10 mL of acetonitrile from QuEChERS extraction). The organic extracts were acidified (adding a 0.1% of formic acid) to promote the cation-exchange interactions between the sorbent and the analyte. The apparent recoveries for fish samples ranged from 22 to 36% depending on the species. In the case of indoor dust samples, the recovery was 41%. It should be highlighted the low matrix effect encountered in such complex samples, with values ranging from -7 to 5% for fish and dust samples. Finally, various samples were analyzed. The concentration in river samples ranged from 31 to 136 ng/L; in effluent wastewater samples, from 55 to 191 ng/L; in influent wastewater samples, from 131 to 549 ng/L; in fish samples, from 14 to 57 ng/g dried weight; and in indoor dust samples, from

Assuntos
Espectrometria de Massas em Tandem , Poluentes Químicos da Água , Animais , Espectrometria de Massas em Tandem/métodos , Águas Residuárias , Água/análise , Poeira/análise , Poluentes Químicos da Água/análise , Extração em Fase Sólida/métodos , Peixes , Cátions/análise
16.
Anal Bioanal Chem ; 416(1): 203-214, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37914955

RESUMO

In this study, an integrated QuEChERS method was developed for the rapid determination of 22 per- and polyfluoroalkyl substances (PFASs) in milk by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The extraction and purification processes were combined into one step with this method. Meanwhile, the solid-liquid separation was carried out by magnetic suction (Fe3O4-SiO2) instead of the centrifugal process. The primary experimental parameters were optimized, including the type of extraction solvent, the amounts of magnetic nanomaterials (Fe3O4-SiO2), and the purification materials (ZrO2 and C18). The developed method exhibits high precision (RSDs < 9.9%), low limits of detection (0.004-0.079 µg/kg) and limits of quantitation (0.01-0.26 µg/kg), and acceptable recovery (71.7-116%) under optimized conditions. The developed integrated QuEChERS method had clear superiority in terms of sample pretreatment time, operating procedures, reagent amount, and recovery. This makes it an excellent alternative analytical technique for PFAS residue measurement at low micrograms-per-kilogram ranges with desirable sensitivity.


Assuntos
Fluorocarbonos , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Extração em Fase Sólida/métodos , Leite/química , Dióxido de Silício , Espectrometria de Massa com Cromatografia Líquida , Fluorocarbonos/análise
17.
Anal Bioanal Chem ; 416(8): 1867-1881, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38349535

RESUMO

The sample preparation step is pivotal in glycoproteomic analysis. An effective approach in glycoprotein sample preparation involves enriching glycopeptides by solid-phase extraction (SPE) using polar stationary phases in hydrophilic interaction liquid chromatography (HILIC) mode. The aim of this work is to show how different experimental conditions influence the enrichment efficiency of glycopeptides from human immunoglobulin G (IgG) on an aminopropyl-modified SPE column. Different compositions of the elution solvent (acetonitrile, methanol, and isopropanol), along with varying concentrations of elution solvent acidifiers (formic and acetic acid), and different concentrations of acetonitrile for the conditioning and washing solvents (65%, 75%, and 85% acetonitrile) were tested to observe their effects on the glycopeptide enrichment process. Isopropanol proved less effective in enriching glycopeptides, while acetonitrile was the most efficient, with methanol in between. Higher formic acid concentrations in the elution solvent weakened the ionic interactions, particularly with sialylated glycopeptides. Substituting formic acid with acetic acid led to earlier elution of more glycopeptides. The acetonitrile concentration in conditioning and washing solutions played a key role; at 65% acetonitrile, glycopeptides were not retained on the SPE column and were detected in the flow-through fraction. Ultimately, it was proven that the enrichment method was applicable to human plasma samples, resulting in a significant decrease in the abundances of non-glycosylated peptides. To the best of our knowledge, this study represents the first systematic investigation into the impact of the mobile phase on glycopeptide enrichment using an aminopropyl-modified SPE column in HILIC mode. This study demonstrates the substantial impact of even minor variations in experimental conditions, which have not yet been considered in the literature, on SPE-HILIC glycopeptide enrichment. Consequently, meticulous optimization of these conditions is imperative to enhance the specificity and selectivity of glycoproteomic analysis, ensuring accurate and reliable quantification.


Assuntos
Formiatos , Glicopeptídeos , Metanol , Humanos , Glicopeptídeos/química , 2-Propanol , Cromatografia Líquida/métodos , Solventes , Imunoglobulina G/química , Interações Hidrofóbicas e Hidrofílicas , Extração em Fase Sólida/métodos , Acetonitrilas , Acetatos
18.
Anal Bioanal Chem ; 416(5): 1127-1137, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38108844

RESUMO

Many agrochemicals are chiral molecules, and most of them are marketed as racemates or diastereomeric mixtures. Stereoisomers that are not the active enantiomer have little or no pesticidal activity and can exert serious toxic effects towards non-target organisms. Thus, investigating the possible exposure to different isomers of chiral pesticides is an urgent need. The present work was aimed at developing a new enantioselective high-performance liquid chromatography-mass spectrometry method for the simultaneous determination of nine chiral pesticides in urine. Two solid-phase extraction (SPE) procedures, based on different carbon-based sorbents (graphitized carbon black (GCB) and buckypaper (BP)), were developed and compared. By using GCB, all analytes were recovered with yields ranging from 60 to 97%, while BP allowed recoveries greater than 54% for all pesticides except those with acid characteristics. Baseline separation was achieved for the enantiomers of all target agrochemicals on a Lux Cellulose-2 column within 24 min under reversed-phase mode. The developed method was then validated according to the FDA guidelines for bioanalytical methods. Besides recovery, the other evaluated parameters were precision (7-15%), limits of detection (0.26-2.21 µg/L), lower limits of quantitation (0.43-3.68 µg/L), linear dynamic range, and sensitivity. Finally, the validated method was applied to verify the occurrence of the pesticide enantiomers in urine samples from occupationally exposed workers.


Assuntos
Agroquímicos , Praguicidas , Humanos , Agroquímicos/análise , Estereoisomerismo , Fuligem , Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Praguicidas/análise , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos
19.
Anal Bioanal Chem ; 416(14): 3335-3347, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38661944

RESUMO

Stanozolol, a synthetic derivative of testosterone, is one of the common doping drugs among athletes and bodybuilders. It is metabolized to a large extent and metabolites are detected in urine for a longer duration than the parent compound. In this study, a novel dummy molecularly imprinted polymer (DMIP) is developed as a sorbent for solid-phase extraction of stanozolol metabolites from spiked human urine samples. The optimized DMIP is composed of stanozolol as the dummy template, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the cross-linker in a ratio of 1:10:80. The extracted analytes were quantitively determined using a newly developed and validated ultrahigh-performance liquid chromatography tandem mass spectrometry method, where the limits of detection and quantitation were 0.91 and 1.81 ng mL-1, respectively, fulfilling the minimum required performance limit decided on by the World Anti-Doping Agency. The mean percentage extraction recoveries for 3'-hydroxystanozolol, 4ß-hydroxystanozolol, and 16ß-hydroxystanozolol are 97.80% ± 13.80, 83.16% ± 7.50, and 69.98% ± 2.02, respectively. As such, the developed DMISPE can serve as an efficient cost-effective tool for doping and regulatory agencies for simultaneous clean-up of the stanozolol metabolites prior to their quantification.


Assuntos
Dopagem Esportivo , Limite de Detecção , Polímeros Molecularmente Impressos , Extração em Fase Sólida , Estanozolol , Estanozolol/urina , Extração em Fase Sólida/métodos , Humanos , Polímeros Molecularmente Impressos/química , Dopagem Esportivo/prevenção & controle , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Detecção do Abuso de Substâncias/métodos , Anabolizantes/urina , Anabolizantes/metabolismo , Impressão Molecular/métodos
20.
Anal Bioanal Chem ; 416(13): 3239-3250, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38573343

RESUMO

Cocaine and antidepressants rank high globally in substance consumption, emphasizing their impact on public health. The determination of these compounds and related substances in biological samples is crucial for forensic toxicology. This study focused on developing an innovative analytical method for the determination of cocaine, antidepressants, and their related metabolites in postmortem blood samples, using unmodified commercial Fe3O4 nanoparticles as a sorbent for dispersive magnetic solid-phase extraction (m-d-SPE), coupled with liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) analysis. An aliquot of 100 µL of whole blood and 5 µL of the internal standard pool were added to 30 mg of nanoparticles. The nanoparticles were separated from the sample using a neodymium magnet inserted into a 3D-printed microtube rack. The liquid was then discarded, followed by desorption with 300 µL of 1/1/1 acetonitrile/methanol/ethyl acetate. The sample was vortexed and separated, and 1.5 µL of the organic supernatant was injected into the LC-MS/MS. The method was acceptably validated and successfully applied to 263 postmortem blood samples. All samples evaluated in this study were positive for at least one substance. The most frequent analyte was benzoylecgonine, followed by cocaine and cocaethylene. The most common antidepressants encountered in the analyzed samples were citalopram and fluoxetine, followed by fluoxetine's metabolite norfluoxetine. This study describes the first report of this sorbent in postmortem blood analysis, demonstrating satisfactory results for linearity, precision, accuracy, and selectivity for all compounds. The method's applicability was confirmed, establishing it as an efficient and sustainable alternative to traditional techniques for forensic casework.


Assuntos
Antidepressivos , Cocaína , Toxicologia Forense , Nanopartículas de Magnetita , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Humanos , Cocaína/sangue , Cocaína/análogos & derivados , Antidepressivos/sangue , Espectrometria de Massas em Tandem/métodos , Toxicologia Forense/métodos , Extração em Fase Sólida/métodos , Nanopartículas de Magnetita/química , Cromatografia Líquida/métodos , Limite de Detecção , Detecção do Abuso de Substâncias/métodos , Masculino , Feminino , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA