Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.072
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Vet Surg ; 53(5): 872-880, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38803143

RESUMO

OBJECTIVE: To evaluate the effect of continuous positive airway pressure (CPAP) on respiratory function in the early postoperative period of brachycephalic dogs. STUDY DESIGN: Prospective, randomized clinical trial. ANIMALS: A total of 32 dogs. METHODS: Dogs were assigned to recover with or without CPAP (control) and assessed at specific time points over 1 h. Treatment was discontinued for dogs with a CPAP tolerance score of 3 or more (from a range of 0-4). The primary outcome was pulse oximetry (SpO2). Secondary outcomes were arterial O2 pressure (PaO2)/FiO2 ratio (PaO2/FiO2), arterial CO2 pressure (PaCO2), and rectal temperature. For dogs that reached a CPAP tolerance score of 3 or more, only the data collected up to the time point before discontinuation were included in the analysis. The treatment effect (ß) was analyzed using random effects models and the results were reported with 95% confidence intervals. RESULTS: Dogs were assigned randomly to each protocol. Baseline characteristics in both groups were comparable. Arterial blood gases were obtained in seven control group dogs and nine CPAP group dogs. Treatment did not affect SpO2 (ß = -0.1, -2.1 to 2.0) but affected the PaO2/FiO2 ratio (ß = 58.1, 2.6 to 113.6), with no effects on PaCO2 (ß = -4.3, -10.5 to 1.9) or temperature (ß = 0.4, -0.8 to 1.6). CONCLUSION: In postoperative brachycephalic dogs, CPAP had no effect on SpO2 but improved the PaO2/FiO2 ratio in brachycephalic dogs postoperatively. CLINICAL SIGNIFICANCE: Continuous positive airway pressure offers a valuable solution to improve gas exchange efficiency, a prevalent concern in postoperative brachycephalic dogs, with the potential to enhance overall outcomes.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Craniossinostoses , Doenças do Cão , Animais , Cães , Pressão Positiva Contínua nas Vias Aéreas/veterinária , Feminino , Masculino , Craniossinostoses/veterinária , Craniossinostoses/cirurgia , Doenças do Cão/cirurgia , Estudos Prospectivos , Gasometria/veterinária
2.
Vet Anaesth Analg ; 51(1): 10-15, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37949743

RESUMO

OBJECTIVE: To evaluate the relationship between oxygen reserve index (ORI) and arterial partial pressure of oxygen (PaO2) in anesthetized dogs. STUDY DESIGN: Prospective experimental study. ANIMALS: A total of eight healthy adult Beagle dogs with a median age of 38 (range 20-87) months and a median body mass of 8.6 (range 7.0-13.8) kg. METHODS: After induction of general anesthesia with propofol, dogs were mechanically ventilated and anesthesia maintained with isoflurane carried in oxygen. Arterial blood samples were collected from a catheter placed in the femoral artery. ORI was measured by placing a CO-oximeter sensor on the tongue. Inspired oxygen fraction (FiO2) was increased from 21% to > 95% in increments of 5%. PaO2 and ORI were recorded and compared at different times. The relationship between ORI and PaO2 was investigated using a nonlinear function, the Hill equation, and a linear regression analysis was performed, as appropriate. RESULTS: A total of 128 pairs of values were compared for all dogs. Applying the Hill equation to the relationship between ORI and PaO2 resulted in R2 = 0.80 (p < 0.001) with a Hill coefficient of 3.7. It was predicted that ORI ranged 0.1-0.9 as PaO2 ranged 127.0-417.9 mmHg and that in the more linear portion of the range, PaO2 of 127.0-289.9 mmHg ORI ranged 0.1-0.7. Linear regression analysis in the more linear portion showed a weak correlation (R2 = 0.29, p = 0.006). CONCLUSIONS AND CLINICAL RELEVANCE: In the present study, the Hill equation predicted the relationship between PaO2 and ORI for PaO2 ranging 127.0-417.9 mmHg in anesthetized dogs. However, in the linear portion of the PaO2, the coefficient of determination was low, indicating that ORI is not a surrogate for PaO2.


Assuntos
Oximetria , Oxigênio , Cães , Animais , Estudos Prospectivos , Pressão Parcial , Oximetria/veterinária , Anestesia Geral/veterinária , Gasometria/veterinária
3.
BMC Vet Res ; 19(1): 241, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980491

RESUMO

BACKGROUND: The oxygen reserve index (ORi) is a real-time, continuous index measured with multi-wavelength pulse CO-oximetry technology. It estimates mild hyperoxemia in humans, which is defined as a partial pressure of oxygen (PaO2) level between 100 and 200 mmHg. The objectives of this study were to assess the correlation between ORi and PaO2, as well as to determine its ability in detecting mild hyperoxemia in dogs. METHODS: This prospective observational study enrolled 37 anaesthetised and mechanically ventilated dogs undergoing elective procedures. Simultaneous measurements of ORi and PaO2 were collected, using a multi-wavelength pulse CO-oximeter with a probe placed on the dog's tongue, and a blood gas analyser, respectively. A mixed-effects model was used to calculate the correlation (r2) between simultaneous measurements of ORi and PaO2. The trending ability of ORi to identify dependable and proportional changes of PaO2 was determined. The diagnostic performances of ORi to detect PaO2 ≥ 150 mmHg and ≥ 190 mmHg were estimated using the area under the receiver operating characteristic curve (AUROC). The effects of perfusion index (PI), haemoglobin (Hb), arterial blood pH and partial pressure of carbon dioxide (PaCO2) on AUROC for PaO2 ≥ 150 mmHg were evaluated. RESULTS: A total of 101 paired measurements of ORi and PaO2 were collected. PaO2 values ranged from 74 to 258 mmHg. A strong positive correlation (r2 = 0.52, p < 0.001) was found between ORi and PaO2. The trending ability ORi was 90.7%, with 92% sensitivity and 89% specificity in detecting decreasing PaO2. An ORi value ≥ 0.53 and ≥ 0.76 indicated a PaO2 ≥ 150 and ≥ 190 mmHg, respectively, with ≥ 82% sensitivity, ≥ 77% specificity and AUROC ≥ 0.75. The AUROC of ORi was not affected by PI, Hb, pH and PaCO2. CONCLUSIONS: In anaesthetised dogs, ORi may detect mild hyperoxaemia, although it does not replace blood gas analysis for measuring the arterial partial pressure of oxygen. ORi monitoring could be used to non-invasively assess oxygenation in dogs receiving supplemental oxygen, limiting excessive hyperoxia.


Assuntos
Oximetria , Oxigênio , Animais , Cães , Artérias , Gasometria/veterinária , Oximetria/veterinária , Oximetria/métodos , Estudos Prospectivos
4.
J Dairy Sci ; 106(4): 2800-2818, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36797188

RESUMO

Surplus dairy calves often arrive at veal and dairy-beef rearing facilities with health and blood metabolite level abnormalities, which can affect their welfare and performance, predisposing them to future health challenges. The objective of this randomized controlled trial was to investigate the effects of transport duration and age at the time of transport on blood parameters in surplus dairy calves following 6, 12, or 16 h of continuous road transportation. All surplus calves from 5 commercial dairy farms in Ontario were enrolled and examined daily before transport (n = 175). On the day of transportation, calves were weighed, blood sampled, and randomly assigned to 6, 12, or 16 h of transportation. Blood samples were then collected immediately after transportation, as well as 24, 48, and 72 h thereafter. Serum was analyzed at a provincial diagnostic laboratory for nonesterified fatty acids (NEFA), ß-hydroxybutyric acid (BHBA), creatine kinase (CK), cholesterol, and haptoglobin. In addition, blood gas and electrolyte values were also assessed at the time of sample collection. Mixed models with repeated measures were used to assess the effects of transport duration, breed, sex, transfer of passive immunity status, weight before transportation, and age at transportation on blood parameters. Immediately following transportation, NEFA and BHBA were greater for calves transported for 12 h (Δ = 0.22 mmol/L NEFA, 95% CI = 0.15 to 0.30; Δ = 0.04 mmol/L BHBA, 95% CI = 0.02 to 0.06) and 16 h (Δ = 0.35 mmol/L NEFA, 95% CI = 0.27 to 0.42; Δ = 0.10 mmol/L BHBA, 95% CI = 0.08 to 0.11) compared with calves transported for 6 h. Glucose was lower immediately following transportation in calves transported for 16 h compared with 6 h (Δ = -15.54 mg/dL, 95% CI = -21.54 to -9.54). In addition, pH and HCO3- were lower in calves transported for 12 (Δ = -0.09 pH, 95% CI = -0.13 to -0.05; Δ = -1.59 mmol/L HCO3-, 95% CI = -2.61 to -0.56) and 16 h (Δ = -0.07 pH, 95% CI = -0.12 to -0.03; Δ = -1.95 mmol/L HCO3-, 95% CI = -2.95 to -0.95) compared with calves transported for 6 h. Calves transported between 15 and 19 d of age had a higher concentration of cholesterol and CK (Δ = 0.27 mmol/L cholesterol; 37.18 U/L CK) compared with 2- to 6-d-old calves, and calves 12 to 14 d old had greater reduction in HCO3- (Δ = -0.92 mmol/L) compared with 2- to 6-d-old calves. These findings show that transporting calves for long distances results in lower glucose concentration and suboptimal energy status, and that this effect varies based on the calf's age.


Assuntos
Bovinos , Meios de Transporte , Animais , Bovinos/sangue , Fatores Etários , Ontário , Fatores de Tempo , Meios de Transporte/estatística & dados numéricos , Glicemia/análise , Masculino , Feminino , Ácidos Graxos não Esterificados/sangue , Ácido 3-Hidroxibutírico/sangue , Creatina Quinase/sangue , Colesterol/sangue , Haptoglobinas/análise , Gasometria/veterinária , Eletrólitos/análise
5.
Vet Anaesth Analg ; 49(3): 299-303, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35292229

RESUMO

OBJECTIVE: To determine the accuracy of variables that influence blood pH, obtained from central venous (jugular vein) blood samples compared with arterial (dorsal pedal artery) samples in anaesthetized dogs with respiratory acidosis. STUDY DESIGN: Prospective, comparative, observational study. ANIMALS: A group of 15 adult male dogs of various breeds weighing 17 (11-42) kg [median (range)]. METHODS: Dogs were premedicated with buprenorphine (0.03 mg kg-1) and medetomidine (0.01 mg kg-1) administered intramuscularly by separate injections, anaesthetized with propofol intravenously to effect and maintained with isoflurane in 50% air-oxygen. Arterial and central venous catheters were placed. After 15 minutes of spontaneous breathing, arterial and central venous blood samples were obtained and analysed within 5 minutes, using a bench-top gas analyser. Differences between arterial and central venous pH and measured variables were assessed using Wilcoxon rank sum test and effect size (r: matched-pairs rank-biserial correlation) was calculated for each comparison. The agreement (bias and limits of agreement: LoAs) between arterial and central venous pH and measured variables were assessed using Bland-Altman; p < 0.05. Data are reported as median and 95% confidence interval. RESULTS: Arterial blood pH was 7.23 (7.19-7.25), and it was significantly greater than central venous samples 7.21 (7.18-7.22; r = 0.41). Agreement between arterial and venous pH was acceptable with a bias of 0.01 (0.002-0.02) and narrow LoAs. PCO2 [arterial 54 (53-58) mmHg, 7.2 (7.1-7.7) kPa; venous 57 (54-62) mmHg, 7.6 (7.2-8.3) kPa], bicarbonate ion concentration and base excess did not differ between samples; however, agreement between arterial and venous PCO2 was not acceptable with a bias of -2 (-5 to 0) mmHg and wide LoAs. CONCLUSIONS AND CLINICAL RELEVANCE: Blood pH measured from central venous (jugular vein) blood is an acceptable clinical alternative to arterial blood (dorsal pedal artery) in normovolaemic anaesthetized dogs with respiratory acidosis.


Assuntos
Acidose Respiratória , Doenças do Cão , Acidose Respiratória/veterinária , Animais , Artérias , Gasometria/veterinária , Dióxido de Carbono , Cães , Concentração de Íons de Hidrogênio , Masculino , Estudos Prospectivos
6.
Vet Anaesth Analg ; 49(3): 275-281, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35256271

RESUMO

OBJECTIVE: To compare the effects of fraction of inspired oxygen (FiO2) with the addition of positive end-expiratory pressure (PEEP) during anesthesia on arterial oxygenation in the first 4 postoperative hours in dogs. We hypothesized that compared with dogs breathing FiO2 ≥ 0.95 and no PEEP (ZEEP), the use of intraoperative PEEP would improve postoperative oxygenation, and that the use of PEEP combined with an FiO2 of 0.4 would further improve it. STUDY DESIGN: Prospective, randomized study. ANIMALS: A total of 30 dogs undergoing unilateral stifle surgery. METHODS: Using a standardized anesthetic protocol, dogs were assigned to either FiO2 ≥ 0.95 and ZEEP, FiO2 ≥ 0.95 and 5 cmH2O PEEP or FiO2 0.4 and 5 cmH2O PEEP. All dogs were mechanically ventilated with a tidal volume of 12 mL kg-1. Dogs breathed room air after recovery from anesthesia. Arterial blood gases were measured during surgical closure and 10, 120 and 240 minutes after extubation. Demographic characteristics were compared with Kruskal-Wallis tests. The effects of treatment and time on the PaO2, PaCO2, PaO2:FiO2 and shunt fraction (F-shunt) were assessed with mixed-effect models. RESULTS: The PaO2 and F-shunt were lower during anesthesia for dogs breathing FiO2 0.4. No differences among groups were measured after extubation for any variable. CONCLUSIONS AND CLINICAL RELEVANCE: Compared with dogs ventilated with FiO2 ≥ 0.95 and ZEEP, application of 5 cmH2O PEEP did not improve intraoperative gas exchange. The combination of 5 cmH2O PEEP and FiO2 0.4 resulted in lower intraoperative F-shunt values. However, no benefits from those maneuvers on postoperative PaO2 and F-shunt were recorded after extubation, suggesting that alterations in pulmonary function imposed by anesthesia were reversed soon after extubation.


Assuntos
Oxigênio , Joelho de Quadrúpedes , Animais , Gasometria/veterinária , Cães , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/veterinária , Estudos Prospectivos
7.
Vet Anaesth Analg ; 49(1): 85-94, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34872855

RESUMO

OBJECTIVE: To compare the efficacy of single-breath continuous positive airway pressure manoeuvre (CPAP-M) with inhaled salbutamol, and a combination of both. STUDY DESIGN: Randomized, clinical study. ANIMALS: A total of 62 client-owned horses (American Society of Anesthesiologists status III-V) anaesthetized for laparotomy. METHODS: Horses were premedicated with intravenous (IV) xylazine (0.4-0.6 mg kg-1), anaesthesia was induced with midazolam (0.06 mg kg-1 IV) and ketamine (2.2 mg kg-1 IV) and maintained with isoflurane in oxygen using volume-controlled ventilation without positive end-expiratory pressure. If PaO2 was < 100 mmHg (13.3 kPa), either a CPAP-M (50 cmH2O for 45 seconds) or salbutamol (0.002 mg kg-1) was administered. The intervention was considered successful if PaO2 reached 100 mmHg (13.3 kPa). If PaO2 remained < 100 mmHg (13.3 kPa), treatments were switched. PaO2/FiO2 ratio and estimated shunt fraction (F-shunt) were derived from data obtained from arterial blood gas measurements. Dynamic compliance (Cdyn) was calculated from variables recorded at the moment of arterial blood analysis. Fisher's exact tests compared success rates between treatments, and linear models were performed to test whether the treatment modified the values of the measurements; p < 0.05. RESULTS: Salbutamol was the first intervention in 28 horses and was effective in 22 horses. CPAP-M was the first intervention in 34 horses and was effective in 26 horses. CPAP-M after salbutamol was performed in six horses, with four responders, and salbutamol after CPAP-M was administered to eight horses, with one responder. Salbutamol, but not CPAP-M, significantly decreased F-shunt. Both salbutamol and CPAP-M significantly increased Cdyn. CONCLUSIONS AND CLINICAL RELEVANCE: Salbutamol and CPAP-M were comparably effective in improving oxygenation and Cdyn in anaesthetized horses with PaO2 < 100 mmHg (13.3 kPa). Whether combining both treatments might be beneficial needs to be confirmed on a larger number of horses.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Isoflurano , Albuterol , Animais , Gasometria/veterinária , Pressão Positiva Contínua nas Vias Aéreas/veterinária , Cavalos , Laparotomia/veterinária , Oxigênio
8.
Vet Anaesth Analg ; 49(1): 76-84, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34801406

RESUMO

OBJECTIVE: To assess the accuracy and trending capability of continuous measurement of haemoglobin concentration [Hb], haemoglobin oxygen saturation (SaO2) and oxygen content (CaO2) measured by the Masimo Radical-7 pulse co-oximeter in horses undergoing inhalational anaesthesia. STUDY DESIGN: Prospective observational clinical study. ANIMALS: A group of 23 anaesthetized adult horses. METHODS: In 23 healthy adult horses undergoing elective surgical procedures, paired measurements of pulse co-oximetry-based haemoglobin concentration (SpHb), SaO2 (SpO2), and CaO2 (SpOC) and simultaneous arterial blood samples were collected at multiple time points throughout anaesthesia. The arterial samples were analysed by a laboratory co-oximeter for total haemoglobin (tHb), SaO2 and manually calculated CaO2. Bland-Altman plots, linear regression analysis, error grid analysis, four-quadrant plot and Critchley polar plot were used to assess the accuracy and trending capability of the pulse co-oximeter. Data are presented as mean differences and 95% limits of agreement (LoA). RESULTS: In 101 data pairs analysed, the pulse co-oximeter slightly underestimated tHb (bias 0.06 g dL-1; LoA -1.0 to 1.2 g dL-1), SaO2 (bias 1.4%; LoA -2.0% to 4.8%), and CaO2 (bias 0.3 mL dL-1; LoA -2.1 to 2.7 mL dL-1). Zone A of the error grid encompassed 99% of data pairs for SpHb. Perfusion index (PI) ≥ 1% was recorded in 58/101 and PI < 1% in 43/101. The concordance rate for consecutive changes in SpHb and tHb with PI ≥ 1% and < 1% was 80% and 91% with four-quadrant plot, and 45.8% and 66.6% with Critchley polar plot. CONCLUSIONS: Pulse co-oximetry has acceptable accuracy for the values measured, even with low PI, whereas its trending ability requires further investigation in those horses with a higher [Hb] variation during anaesthesia.


Assuntos
Monitorização Intraoperatória , Oximetria , Animais , Gasometria/veterinária , Hemoglobinas/análise , Cavalos , Monitorização Intraoperatória/veterinária , Oximetria/veterinária , Oxigênio , Saturação de Oxigênio
9.
Vet Anaesth Analg ; 49(6): 645-649, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36064498

RESUMO

OBJECTIVE: To describe some cardiorespiratory effects of an inspiratory-to-expiratory (IE) ratio of 1:1 compared with 1:3 in ventilated horses in dorsal recumbency. STUDY DESIGN: Randomized crossover experimental study. ANIMALS: A total of eight anesthetized horses, with 444 (330-485) kg body weight [median (range)]. METHODS: Horses were ventilated in dorsal recumbency with a tidal volume of 15 mL kg-1 and a respiratory rate of 8 breaths minute-1, and IE ratios of 1:1 (IE1:1) and 1:3 (IE1:3) in random order, each for 25 minutes after applying a recruitment maneuver. Spirometry, arterial blood gases and dobutamine requirements were recorded in all horses during each treatment. Electrical impedance tomography (EIT) data were recorded in four horses and used to generate functional EIT variables including regional ventilation delay index (RVD), a measure of speed of lung inflation, and end-expiratory lung impedance (EELI), an indicator of functional residual capacity (FRC). Results were assessed with linear and generalized linear mixed models. RESULTS: Compared with treatment IE1:3, horses ventilated with treatment IE1:1 had higher mean airway pressures and respiratory system compliance (p < 0.014), while peak, end-inspiratory and driving airway pressures were lower (p < 0.001). No differences in arterial oxygenation or dobutamine requirements were observed. PaCO2 was lower in treatment IE1:1 (p = 0.039). Treatment IE1:1 resulted in lower RVD (p < 0.002) and higher EELI (p = 0.023) than treatment IE1:3. CONCLUSIONS AND CLINICAL RELEVANCE: These results suggest that IE1:1 improved respiratory system mechanics and alveolar ventilation compared with IE1:3, whereas oxygenation and dobutamine requirements were unchanged, although differences were small. In the four horses where EIT was evaluated, IE1:1 led to a faster inflation rate of the lung, possibly the result of increased FRC. The clinical relevance of these findings needs to be further investigated.


Assuntos
Dobutamina , Respiração com Pressão Positiva , Cavalos , Animais , Volume de Ventilação Pulmonar , Respiração com Pressão Positiva/veterinária , Gasometria/veterinária , Respiração , Impedância Elétrica
10.
Vet Anaesth Analg ; 48(3): 388-392, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33632615

RESUMO

OBJECTIVE: To evaluate the oxygen reserve index (ORI) as a noninvasive estimate of the PaO2 during moderate hyperoxaemia [100-200 mmHg (13.3-26.6 kPa)], and to determine ORI values identifying PaO2 > 100, > 150 (20.0 kPa) and > 200 mmHg in anaesthetized donkeys with an inspired fraction of oxygen (FiO2) > 0.95. STUDY DESIGN: Prospective observational study. ANIMALS: A group of 28 adult standard donkeys aged (mean ± standard deviation) 4 ± 2 years and weighing 135 ± 15 kg. METHODS: Donkeys were sedated intramuscularly with xylazine and butorphanol; anaesthesia was induced with ketamine and diazepam and maintained with isoflurane in oxygen. An adhesive sensor probe was applied to the donkey's tongue and connected to a Masimo pulse co-oximeter to determine ORI values. An arterial catheter was inserted into an auricular artery. After ORI signal stabilization, the value was noted and PaO2 determined by blood gas analysis. The Pearson correlation coefficient was used to assess the relationship between ORI and PaO2 for oxygen tension < 200 mmHg (< 26.6 kPa). The Youden index was used to identify the value of ORI that detected PaO2 > 150 and 200 mmHg (20.0 and 26.6 kPa) with the highest sensitivity and specificity. RESULTS: A total of 106 paired measurements were collected. A mild positive correlation was observed between ORI and PaO2 for values < 200 mmHg (26.6 kPa; r = 0.52). An ORI > 0.0, > 0.1 and > 0.3 indicated a PaO2 > 100, > 150 and > 200 mmHg (13.3, 20.0 and 26.6 kPa) with negative predictive values > 94%. CONCLUSIONS AND CLINICAL RELEVANCE: ORI may provide a noninvasive indication of PaO2 > 100, > 150 and > 200 mmHg (13.3, 20.0 and 26.6 kPa) in anaesthetized donkeys with an FiO2 > 0.95, although it does not replace blood gas analysis for assessment of oxygenation.


Assuntos
Gasometria/veterinária , Equidae , Oxigênio , Animais , Artérias , Oximetria/veterinária , Pressão Parcial
11.
Vet Anaesth Analg ; 48(6): 841-853, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34391669

RESUMO

OBJECTIVE: To assess and compare the effect of intraoperative stepwise alveolar recruitment manoeuvres (ARMs), followed by individualized positive end-expiratory pressure (PEEP), defined as PEEP at maximal respiratory system compliance + 2 cmH2O (PEEPmaxCrs+2), with that of spontaneous ventilation (SV) and controlled mechanical ventilation (CMV) without ARM or PEEP on early postoperative arterial oxygenation in anaesthetized healthy dogs. STUDY DESIGN: Prospective, randomized, nonblinded clinical study. ANIMALS: A total of 32 healthy client-owned dogs undergoing surgery in dorsal recumbency. METHODS: Dogs were ventilated intraoperatively (inspired oxygen fraction: 0.5) with one of the following strategies: SV, CMV alone, and CMV with PEEPmaxCrs+2 following a single ARM (ARM1) or two ARMs (ARM2, the second ARM at the end of surgery). Arterial blood gas analyses were performed before starting the ventilatory strategy, at the end of surgery, and at 5, 10, 15, 30 and 60 minutes after extubation while breathing room air. Data were analysed using Kruskal-Wallis and Friedman tests (p < 0.050). RESULTS: At any time point after extubation, PaO2 was not significantly different between groups. At 5 minutes after extubation, PaO2 was 95.1 (78.1-104.0), 93.8 (88.3-104.0), 96.9 (86.6-115.0) and 89.1 (87.6-102.0) mmHg in the SV, CMV, ARM1 and ARM2 groups, respectively. PaO2 decreased at 30 minutes after extubation in the CMV, ARM1 and ARM2 groups (p < 0.050), but it did not decrease after 30 minutes in the SV group. Moderate hypoxaemia (PaO2, 60-80 mmHg) was observed in one dog in the ARM1 group and two dogs each in the SV and ARM2 groups. CONCLUSIONS AND CLINICAL RELEVANCE: Intraoperative ARMs, followed by PEEPmaxCrs+2, did not improve early postoperative arterial oxygenation compared with SV or CMV alone in healthy anaesthetized dogs. Therefore, this ventilatory strategy might not be clinically advantageous for improving postoperative arterial oxygenation in healthy dogs undergoing surgery when positioned in dorsal recumbency.


Assuntos
Pulmão , Respiração com Pressão Positiva , Animais , Gasometria/veterinária , Cães , Oxigênio , Respiração com Pressão Positiva/veterinária , Estudos Prospectivos
12.
Vet Anaesth Analg ; 48(3): 297-304, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33610477

RESUMO

OBJECTIVE: To compare values of haemoglobin concentration (SpHb), arterial haemoglobin saturation (SpO2) and calculated arterial oxygen content (SpOC), measured noninvasively with a pulse co-oximeter before and after in vivo adjustment (via calibration of the device using a measured haemoglobin concentration) with those measured invasively using a spectrophotometric-based blood gas analyser in anaesthetized dogs. STUDY DESIGN: Prospective observational clinical study. ANIMALS: A group of 39 adult dogs. METHODS: In all dogs after standard instrumentation, the dorsal metatarsal artery was catheterised for blood sampling, and a pulse co-oximeter probe was applied to the tongue for noninvasive measurements. Paired data for SpHb, SpO2 and SpOC from the pulse co-oximeter and haemoglobin arterial oxygen saturation (SaO2) and arterial oxygen content (CaO2) from the blood gas analyser were obtained before and after in vivo adjustment. Bland-Altman analysis for repeated measurements was used to evaluate the bias, precision and agreement between the pulse co-oximeter and the blood gas analyser. Data are presented as mean differences and 95% limits of agreement (LoA). RESULTS: A total of 39 data pairs were obtained before in vivo adjustment. The mean invasively measured haemoglobin-SpHb difference was -2.7 g dL-1 with LoA of -4.9 to -0.5 g dL-1. After in vivo adjustment, 104 data pairs were obtained. The mean invasively measured haemoglobin-SpHb difference was -0.2 g dL-1 with LoA of -1.1 to 0.6 g dL-1. The mean SaO2-SpO2 difference was 0.86% with LoA of -0.8% to 2.5% and that between CaO2-SpOC was 0.66 mL dL-1 with LoA of -2.59 to 3.91 mL dL-1. CONCLUSIONS: Before in vivo adjustment, pulse co-oximeter derived values overestimated the spectrophotometric-based blood gas analyser haemoglobin and CaO2 values. After in vivo adjustment, the accuracy, precision and LoA markedly improved. Therefore, in vivo adjustment is recommended when using this device to monitor SpHb in anaesthetised dogs.


Assuntos
Hemoglobinas , Oximetria , Animais , Gasometria/veterinária , Cães , Hemoglobinas/análise , Oximetria/veterinária , Oxigênio , Reprodutibilidade dos Testes , Tecnologia
13.
BMC Vet Res ; 16(1): 182, 2020 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-32513241

RESUMO

BACKGROUND: A greater understanding of exercise physiology and biochemistry is required for the sport horse disciplines, including show jumping. Conditioning of horses for show jumping is empirical because they are primarily trained on flat ground, however the equivalent workload between jumping and flat work is currently unknown. The objectives of the study were therefore to compare the physiological demands of Warmblood show jumpers over a standardized 1.10 m course vs a 600 m standardized incremental exercise test on flat ground, and to report reference field test values for competitive show jumping horses. In this prospective field study, 21 healthy, actively competing Warmblood show jumping horses were assessed to determine physiological variables after a standardized jumping course at 6.4 m/s (average speed) and track standardized incremental exercise test at 5 m/s, 8 m/s and 11 m/s. Heart rate, velocity, blood lactate, blood pH, pCO2, bicarbonate, PCV and TP concentrations were recorded. V200, V170 and VLa4 were calculated. Parametric statistics were performed on analysis of all 21 horses' variables. RESULTS: Contrary to exercise at 5 m/s and 11 m/s, cantering at 8 m/s did not induce any significant difference in blood lactate, mean heart rate or mean venous blood pH compared to after completion of the jumping course. CONCLUSIONS: Jumping a 1.10 m course demands a statistically similar workload to cantering around a flat track at 8 m/s. This study will help to test fitness and design conditioning programs for Warmblood show jumping horses.


Assuntos
Teste de Esforço/veterinária , Cavalos/fisiologia , Condicionamento Físico Animal/fisiologia , Animais , Gasometria/veterinária , Proteínas Sanguíneas , Teste de Esforço/métodos , Frequência Cardíaca/fisiologia , Hematócrito , Cavalos/sangue , Concentração de Íons de Hidrogênio , Ácido Láctico/sangue , Esportes
14.
BMC Vet Res ; 16(1): 209, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32571307

RESUMO

BACKGROUND: In humans, respiratory complications in patients with acute pancreatitis (AP) are a common life-threatening comorbidity. Since possible lung impairment has not been individually evaluated in canine AP, the aims of the present study were to: (1) describe the prevalence, types and severity of pulmonary complications in dogs with acute presentation of AP, and (2) evaluate their association with mortality. AP diagnosis was based on compatible clinical and laboratory parameters, abnormal canine pancreatic-lipase test, and positive abdominal ultrasound within 48 h from admission. The canine acute pancreatitis severity score (CAPS) was calculated for each dog at admission. Arterial blood gas analysis and thoracic radiography were performed at admission. Thoracic radiography was classified on the basis of pulmonary pattern (normal, interstitial or alveolar) and a modified lung injury score (mLIS) was applied to the ventrodorsal projections for each dog. VetALI/VetARDS were diagnosed using current veterinary consensus. Dogs were divided into non-survivors or survivors (hospital discharge). Clinical, radiological and blood gas parameters collected at presentation were compared between survivors and non-survivors and associated with mortality. RESULTS: This prospective cohort study included twenty-six client-owned dogs with AP. Twelve out of twenty-six dogs (46%) died or were euthanized. At admission, thirteen dogs showed respiratory distress at physical examination, which was associated with death (P < 0.001). Radiographic abnormalities were found in twenty-one dogs: alveolar (n = 11) and interstitial pattern (n = 10). Radiographic alterations and mLIS score were both associated with death (P = 0.02 and P = 0.0023). The results of the arterial blood-gas evaluation showed that non-survivors had lower PaCO2 and HCO3- levels, and higher A-a gradient than survivors (P = 0.0014, P = 0.019 and P = 0.004, respectively). Specifically, three dogs had aspiration pneumonia, and VetALI was diagnosed in nine dogs (34.6%), and no dogs met the criteria for VetARDS. The presence of VetALI was associated with mortality (P < 0.001). CONCLUSIONS: As with humans, possible lung impairments, such as VetALI, should be investigated in dogs with acute presentation of pancreatitis.


Assuntos
Lesão Pulmonar Aguda/veterinária , Doenças do Cão/diagnóstico , Pancreatite/veterinária , Pneumonia Aspirativa/veterinária , Lesão Pulmonar Aguda/complicações , Lesão Pulmonar Aguda/mortalidade , Animais , Gasometria/veterinária , Estudos de Coortes , Doenças do Cão/mortalidade , Cães , Feminino , Masculino , Pancreatite/complicações , Pancreatite/mortalidade , Pneumonia Aspirativa/complicações , Estudos Prospectivos , Radiografia Torácica/veterinária
15.
J Dairy Sci ; 103(6): 5509-5513, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32307153

RESUMO

The objectives of this study were to describe the stability of bovine whole-blood electrolytes, glucose, and lactate in samples collected in lithium heparin tubes and stored in thermoconductive modules immersed in ice water. A total of 99 Jersey cows (40 first-parity, 18 second-parity, and 41 third-parity or greater cows) from a commercial dairy farm in West Texas were enrolled between June and July 2018. Blood was collected from the jugular vein using a 60-mL polypropylene syringe and equally distributed into 5 spray-dried evacuated lithium heparin tubes. Baseline samples were analyzed within 90 s of collection using a benchtop blood gas analyzer. The remaining 4 tubes were stored in a thermoconductive, passive-temperature-regulating module inside a cooler with ice water. At 30 min and 2, 4, and 8 h post-collection, samples were removed from the temperature-regulating module, gently inverted for 10 s, and analyzed. Repeated-measures models were built to evaluate the effect of time on the stability of ionized Ca (iCa), ionized Mg (iMg), Na, K, Cl, glucose, and lactate. Most of the analytes investigated remained stable up to 8 h under ice water storage conditions before analysis, including iCa, iMg, Cl, glucose, and lactate. However, Na and K were significantly affected by delayed analysis: Na remained stable up to 4 h post-collection, but K was not stable starting at 2 h post-collection. The results of this study are useful in helping future researchers and consultants to recognize acceptable time delays between whole blood collection and processing or analysis for electrolytes, glucose, and lactate.


Assuntos
Coleta de Amostras Sanguíneas/veterinária , Bovinos/sangue , Eletrólitos/sangue , Heparina/química , Animais , Gasometria/veterinária , Glicemia/análise , Cálcio/sangue , Cloretos/sangue , Feminino , Ácido Láctico/sangue , Lítio/química , Magnésio/sangue , Potássio/sangue , Refrigeração/veterinária , Sódio/sangue , Texas , Fatores de Tempo
16.
Vet Surg ; 49(3): 472-479, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31916608

RESUMO

OBJECTIVE: To determine the prognostic value of (1) colonic venous lactate or peripheral lactate values obtained before and after manual correction of a large colon volvulus and (2) a combination of variables including pelvic flexure biopsy. STUDY DESIGN: Prospective clinical study. ANIMALS: Forty adult horses in which large colon volvulus was diagnosed intraoperatively. METHODS: Colonic venous, peripheral venous, and arterial blood samples were collected to measure lactate values before and after manual correction. Mucosal biopsy samples were obtained in cases that underwent enterotomy or colonic resection and anastomosis. Interstitium to crypt (I:C) ratio and hemorrhage scores were measured. Optimal cutoff values were determined by receiver operator curve analysis, and associations between variables and short-term outcome were determined by univariable regression. Short-term survival was defined as horses being discharged from the hospital. P ≤ .05 was considered significant. RESULTS: No association was found between colonic venous lactate values before (P = .011) or after (P = .201) manual correction of large colon volvulus and determination of short-term outcome. Peripheral venous lactate at admission ≥3.2 mmol/L and after manual correction ≥5 mmol/L, arterial lactate postmanual correction ≥3.53 mmol/L, and histomorphometric measurements of mucosal hemorrhage ≥3 and I:C ratio > 1 were associated with poor short-term outcome. CONCLUSION: Peripheral lactate values, histomorphometric measures of I:C ratio, and hemorrhage score provided prognostic information that could help guide recommendations made to owners. CLINICAL SIGNIFICANCE: Peripheral lactate values after manual correction provide important intraoperative diagnostic information to assist in predicting case outcome in the operative and immediately postoperative period.


Assuntos
Colo/patologia , Doenças dos Cavalos/sangue , Doenças dos Cavalos/diagnóstico , Volvo Intestinal/veterinária , Lactatos/sangue , Animais , Biópsia/veterinária , Gasometria/veterinária , Feminino , Hemorragia/patologia , Doenças dos Cavalos/terapia , Cavalos , Volvo Intestinal/sangue , Volvo Intestinal/diagnóstico , Volvo Intestinal/terapia , Masculino , Prognóstico , Estudos Prospectivos
17.
Vet Anaesth Analg ; 47(3): 295-300, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32197879

RESUMO

OBJECTIVE: To evaluate arterial oxygenation during the first 4 postoperative hours in dogs administered different fractions of inspired oxygen (FiO2) during general anesthesia with mechanical ventilation. STUDY DESIGN: Prospective, randomized clinical trial. ANIMALS: A total of 20 healthy female dogs, weighing >15 kg and body condition scores 3-7/9, admitted for ovariohysterectomy. METHODS: Dogs were randomized to breathe an FiO2 >0.9 or 0.4 during isoflurane anesthesia with intermittent positive pressure ventilation. The intraoperative PaO2:FiO2 ratio was recorded during closure of the linea alba. Arterial blood was obtained 5, 60 and 240 minutes after extubation for measurement of PaO2 and PaCO2 (FiO2 = 0.21). Demographic characteristics, duration of anesthesia, PaO2:FiO2 ratio and anesthetic agents were compared between groups with Wilcoxon tests. The postoperative PaO2, PaCO2, rectal temperature, a visual sedation score and events of hypoxemia (PaO2 < 80 mmHg) were compared between groups with mixed-effects models or generalized linear mixed models. RESULTS: Groups were indistinguishable by demographic characteristics, duration of anesthesia, anesthetic agents administered and intraoperative PaO2:FiO2 ratio (all p > 0.08). Postoperative PaO2, PaCO2, rectal temperature or sedation score were not different between groups (all p > 0.07). During the first 4 postoperative hours, hypoxemia occurred in three and seven dogs that breathed FiO2 >0.9 or 0.4 during anesthesia, respectively (p = 0.04). CONCLUSIONS AND CLINICAL RELEVANCE: The results identified no advantage to decreasing FiO2 to 0.4 during anesthesia with mechanical ventilation with respect to postoperative oxygenation. Moreover, the incidence of hypoxemia in the first 4 hours after anesthesia was higher in these dogs than in dogs breathing FiO2 >0.9.


Assuntos
Anestesia Geral/veterinária , Cães/fisiologia , Hipóxia/veterinária , Oxigenoterapia/veterinária , Respiração Artificial/veterinária , Animais , Gasometria/veterinária , Feminino , Histerectomia/veterinária , Oxigênio/sangue , Período Pós-Operatório , Estudos Prospectivos
18.
Vet Anaesth Analg ; 47(4): 552-556, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32451198

RESUMO

OBJECTIVE: To compare F-shunt and oxygen content indices in sheep ventilated with a positive end-expiratory pressure (PEEP) of 5 cmH2O alone or preceded by a stepwise alveolar recruitment manoeuvre (ARM). STUDY DESIGN: Randomized crossover design. ANIMALS: A total of six nonpregnant Brogna ewes weighing 34-47 kg, undergoing thoracolumbar magnetic resonance scan. METHODS: In medetomidine-sedated sheep, anaesthesia was induced with propofol and maintained with isoflurane 1.1% ± 0.1% and an inspired oxygen fraction (FiO2) of 0.4. Animals were placed in left lateral recumbency and, after 10 minutes of spontaneous breathing, mechanically ventilated with 5 cmH2O of PEEP with (group ARM) or without (group PEEP) a stepwise recruitment manoeuvre. Maintaining a fixed driving pressure of 15 cmH2O, PEEP was increased from 0 to 20 cmH2O every 3 minutes in 5 cmH2O increments. In each sheep, arterial blood samples were collected to measure arterial gases and to calculate F-shunt, PaO2/alveolar oxygen partial pressure (PAO2) and PaO2/FIO2 during spontaneous breathing before mechanical ventilation (T0), after 20 minutes of ventilation (T20) and during spontaneous breathing at extubation (Text). RESULTS: Both ventilatory strategies improved the arterial oxygen content although four animals in group PEEP showed oxygen content compatible with hypoxia compared with group ARM. F-shunt values were not statistically different at any time point in sheep that underwent only PEEP ventilation while they decreased at T20 and Text compared with T0 in group ARM. At extubation F-shunt was statistically lower in sheep that underwent an ARM. Mechanical ventilation improved PaO2/PAO2 and PaO2/FIO2 but they did not differ between groups. CONCLUSIONS: and clinical relevance The stepwise ARM evaluated in this study improved oxygenation indices and decreased F-shunt. This effect was maintained at extubation compared with sheep that were ventilated with only PEEP 5 cmH2O.


Assuntos
Respiração Artificial/veterinária , Anestesia/veterinária , Anestésicos , Animais , Gasometria/veterinária , Estudos Cross-Over , Feminino , Isoflurano , Oxigênio/sangue , Respiração com Pressão Positiva/veterinária , Propofol , Respiração Artificial/métodos , Ovinos
19.
Vet Clin North Am Equine Pract ; 36(1): 161-171, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32145834

RESUMO

Point-of-care testing (POCT) refers to benchtop diagnostic modalities that have been translated into portable and easy-to-use formats suitable for patient-side use. Recent advances in diagnostic technology have allowed the development of a growing collection of POCT assays available to equine practitioners. Advantages include rapid results that reduce initial guesswork and promote diagnosis-targeted patient care, which may ultimately provide better clinical outcomes. Small handheld devices comprise most POCT technologies, providing qualitative or quantitative determination of an increasing range of analytes, including critical care analyzers and, more recently, hematology and immunology analyzers. This article discusses commercially available equine POCT.


Assuntos
Doenças dos Cavalos/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Gasometria/veterinária , Doenças dos Cavalos/sangue , Cavalos , Patologia Clínica
20.
J Zoo Wildl Med ; 51(1): 110-115, 2020 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-32212553

RESUMO

This study assessed the in vitro temporal changes that occur in blood pH and lactate concentrations for an elasmobranch species and a chelonian species, as well as blood gases (partial pressures of carbon dioxide [pCO2] and oxygen [pO2]) for a chelonian species, with a portable clinical point-of-care analyzer. Blood samples were collected from 10 cownose rays (Rhinoptera bonasus) and 10 red-eared sliders (Pseudemys scripta elegans), stored on ice, and serially analyzed at six time points up to 90 min postcollection. Results indicate that analysis should be conducted as soon as possible after blood collection for these species, with immediate analysis being preferred. However, if analysis must be delayed, syringes may be capped, placed on ice, and analyzed at a later time. Analysis within 90 min provided clinically acceptable results for pH and lactate in both species and for pCO2 in red-eared sliders, whereas substantial artifactual increases of pO2 were seen in red-eared sliders.


Assuntos
Animais de Zoológico/sangue , Gasometria/veterinária , Ácido Láctico/sangue , Rajidae/sangue , Tartarugas/sangue , Veias/química , Animais , Concentração de Íons de Hidrogênio , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA