Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 915
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(5): 277, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38668852

RESUMO

OBJECTIVES: To evaluate the influence of collateral vascularization on surgical cleft palate closure and deformities. MATERIALS AND METHODS: Corrosion casting was performed using red-colored acrylic resin in twelve fresh adult cadavers with a normal hard palate. Additionally, white-colored barium sulfate was injected into a fetus with a unilateral complete cleft palate, and layer-by-layer tissue dissection was performed. Both substances were injected into the external carotid arteries. Corrosion casting involved dissolving the soft and hard tissues of the orofacial area utilizing an enzymatic solution. RESULTS: In normal palates, bilateral intraosseous infraorbital arteries formed a network in the premaxilla with the intraosseous nasopalatine- and greater palatine arteries (GPAs). The perforating GPAs anastomosed with the sphenopalatine artery sub-branches. Bilateral extraosseous GPA anastomoses penetrated the median palatine suture. Complex vascularization in the retrotuberal area was detected. In the cleft zone, anastomoses were omitted, whereas in the non-cleft zone, enlarged GPAs were distributed along the cleft edges and followed the anatomical course anteriorly to initiate the network with facial artery sub-branches. CONCLUSIONS: The anatomical subunits of the palate exhibited distinct anastomosis patterns. Despite omitted anastomoses with collateral circulation in the cleft zone, arteries maintained their anatomical pattern as seen in the normal specimen in the non-cleft zone. CLINICAL RELEVANCE: Based on the findings in normal- and cleft palates, surgeons may expect developed anastomosis patterns in the non-cleft zone. Due to the lack of microcirculation in the cleft zone, the existent anastomoses should be maintained as much as possible by the surgical technique. This applies anteriorly in the incisive canal territory, alveolar ridges, and posteriorly in the retrotuberal area.


Assuntos
Cadáver , Fissura Palatina , Circulação Colateral , Molde por Corrosão , Palato Duro , Humanos , Fissura Palatina/cirurgia , Circulação Colateral/fisiologia , Palato Duro/irrigação sanguínea , Feminino , Masculino , Sulfato de Bário , Adulto , Feto/irrigação sanguínea
2.
J Anat ; 242(1): 76-80, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35751869

RESUMO

Many studies of cardiovascular function require a realistic representation of vascular geometry. Corrosion casting has been used to acquire such geometries for many decades. However, the fidelity with which this method reproduces vascular anatomy has not been completely determined. Here we report on the non-linear shrinkage characteristics and exothermic properties of Batson's #17, a widely used casting resin, in model systems and in aortas of rats and rabbits. The setting process was captured using high-resolution photography. Shrinkage ranged from 3.4 ± 1.5% of the diameter in 1 ml plastic syringes (inner diameter 4.8 mm) to 19.6 ± 5.6% in the aorta of rats (diameter 1.5-2.6 mm). In addition, aortic curvature and branching angles changed during setting. These effects should be determined and corrected in studies of vascular geometry where high accuracy is required.


Assuntos
Aorta , Modelos Biológicos , Ratos , Coelhos , Animais , Molde por Corrosão
3.
Vet Radiol Ultrasound ; 64(4): 713-723, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37133979

RESUMO

In human medicine, magnetic resonance cholangiopancreatography (MRCP) is a valuable diagnostic tool for hepatobiliary and pancreatic diseases. In veterinary medicine, however, data evaluating the diagnostic value of MRCP are limited. The primary objectives of this prospective, observational, analytical investigation were to assess whether MRCP reliably visualizes the biliary tract and pancreatic ducts in cats without and with related disorders, and whether MRCP images and measurements of the ducts agree with those of fluoroscopic retrograde cholangiopancreatography (FRCP), corrosion casting and histopathology. A secondary objective was to provide MRCP reference diameters for bile ducts, GB, and pancreatic ducts. Donated bodies of 12 euthanized adult cats underwent MRCP, FRCP, and autopsy with corrosion casting of the biliary tract and pancreatic ducts using vinyl polysiloxane. Diameters of the biliary ducts, gallbladder (GB), and pancreatic ducts were measured using MRCP, FRCP, corrosion casts and histopathologic slides. There was an agreement between MRCP and FRCP in measuring diameters of the GB body, GB neck, cystic duct, and common bile duct (CBD) at papilla. Strong positive correlations existed between MRCP and corrosion casting for measuring GB body and neck, cystic duct, and CBD at the extrahepatic ducts' junction. In contrast to the reference methods, post-mortem MRCP did not visualize right and left extrahepatic ducts, and pancreatic ducts in most cats. Based on this study, MRCP with 1.5 Tesla can be regarded as a contributory method to improve the assessment of feline biliary tract and pancreatic ducts when their diameter is >1 mm.


Assuntos
Imageamento por Ressonância Magnética , Ductos Pancreáticos , Animais , Gatos , Autopsia/veterinária , Colangiopancreatografia Retrógrada Endoscópica/veterinária , Molde por Corrosão/veterinária , Fluoroscopia/veterinária , Imageamento por Ressonância Magnética/veterinária , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos
4.
J Anat ; 239(3): 682-692, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33817796

RESUMO

The study of the fractal architecture of various organs and structures expanded the possibilities for determining the ranges of their functioning and structural arrangement, which, as a result, was reflected in the development of new approaches to diagnostics and therapeutic impacts. The architecture of the excretory duct systems, similar to the hemo- and lymph- circulatory beds and the bronchial tree, is considered fractal. At the same time, information about hitherto unknown structures of the biliary tree continues to appear in the literature. We aimed to study the features of the spatial geometry of the biliary tree and assess the significance of both its fractal and Euclidean characteristics for the development of approaches that facilitate comprehensive description of intrahepatic biliary tract architecture. We investigated the architecture of the biliary trees of six men, seven male canines, and seven male Wistar rats using the corrosion casting method. Corrosion casts were prepared by injecting solidifying latexes into the bile ducts. The preparations were studied using a light stereomicroscope and a scanning electron microscope. Biliary tree branching is of various types. In addition, the correlation between variations in the caliber and length of the bile ducts and their order is not significant. Therefore, the biliary tree should not be considered as a classical fractal and it consists of the main modules, represented by the network of the bile canaliculi (first nonfractal module) and a biliary tree with a fractal branching (second module) that drains the bile canaliculi mesh and the additional modules represented by the mucosal biliary glands (in mammals with the gallbladder) or the periportal biliary plexus (in mammals without a gallbladder) and the aberrant biliary ducts. Such a configuration of the biliary bed should optimally ensure the smooth implementation of the physiological function of the liver, as well as its adaptation to different pathologies accompanied by biliary hypertension. It also might be considered in the diagnosis and assessment of ductular reaction, biliary regeneration, and/or carcinogenesis.


Assuntos
Sistema Biliar/anatomia & histologia , Fígado/anatomia & histologia , Animais , Molde por Corrosão , Cães , Humanos , Masculino , Ratos , Ratos Wistar
5.
Clin Anat ; 34(4): 527-535, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32115761

RESUMO

INTRODUCTION: Spinal cord ischemia after cardiovascular interventions continues to be a devastating problem in modern surgery. The role of intraspinal vascular networks and anterior radiculomedullary arteries (ARMA) in preventing spinal cord ischemia is poorly understood. MATERIALS AND METHODS: Landrace pigs (n = 30, 35.1 ± 3.9 kg) underwent a lateral thoracotomy. Fluorescent microspheres were injected into the left atrium and a reference sample was aspirated from the descending aorta. Repeated measurements of spinal cord and renal cortical blood flow from the left and right kidneys with three different microsphere colors in five pigs were taken to validate reproducibility. Spinal cord blood flow to the upper thoracic (T1-T4), mid-thoracic (T5-T8), lower thoracic (T9-T13), and lumbar (L1-L3) levels were determined. After euthanasia, we carried out selective vascular corrosion cast and counted the left and right ARMAs from levels T1-T13. RESULTS: Blood flow analysis of the left and right kidneys revealed a strong correlation (r = .94, p < .001). We detected more left than right ARMAs, with the highest prevalence at T4 (p < .05). The mean number of ARMAs was 8 ± 2. Their number in the upper thoracic region ranged from 2 to 7 (mean of 5 ± 1), while in the lower thoracic region they ranged from 0 to 5 (mean of 3 ± 1 [p < .001]). CONCLUSIONS: This study shows that combining fluorescence microsphere technique and vascular corrosion cast is well suited for assessing the blood flow and visualizing the arteries at the same time.


Assuntos
Aorta Torácica/cirurgia , Circulação Colateral/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Isquemia do Cordão Espinal/prevenção & controle , Medula Espinal/irrigação sanguínea , Animais , Molde por Corrosão , Estudos de Viabilidade , Fluorescência , Microesferas , Modelos Animais , Suínos
6.
Folia Med Cracov ; 61(4): 45-54, 2021 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-35180201

RESUMO

Three-dimensional (3D) printed model of the renal vasculature shows a high level of accuracy of subsequent divisions of both the arterial and the venous tree. However, minor artifacts appeared in the form of oval endings to the terminal branches of the vascular tree, contrary to the anticipated sharply pointed segments. Unfortunately, selective laser sintering process does not currently permit to present the arterial, venous and urinary systems in distinct colors, hence topographic relationship between the vascular and the pelvicalyceal systems is difficult to attain. Nonetheless, the 3D printed model can be used for educational purposes to demonstrate the vast renal vasculature and may also serve as a reference model whilst evaluating morphological anomalies of the intrarenal vasculature in a surgical setting.


Assuntos
Artefatos , Rim , Molde por Corrosão , Humanos , Imageamento Tridimensional/métodos , Rim/diagnóstico por imagem , Tecnologia , Microtomografia por Raio-X
7.
Surg Radiol Anat ; 42(12): 1407-1420, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33070211

RESUMO

Two "surgeons-anatomists" Rapp in Montpellier and Couinaud in Paris at the same period (1953) given precise anatomy useful for the hepatic surgery and to the tremendous upheavals of radiological investigations. Actually, the fundamental anatomy of liver is classic with 8 segments with autonomous territories having a vascular afferent pedicle and a venous and biliary efferent drainage. These autonomous territories supported the surgical approach of the liver with the possibility of resecting a hepatic territory in a carcinological perspective well saving quite vascularized parenchyma. It will be in the future history about liver morphology to specify the contribution of these two "surgeons-anatomists". Actually it will be possible to look in the "Conservatory of Anatomy" in Montpellier these original livers corrosions.


Assuntos
Anatomia/história , Fígado/irrigação sanguínea , Molde por Corrosão , França , História do Século XX
8.
Clin Anat ; 32(1): 46-52, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30281168

RESUMO

An increasing number of observations have called the general scheme of five renal segments into question: anatomists, radiologists, and surgeons have reported discrepancies between Graves's scheme and morphological observations. The aims of the present study are: (1) to assess the correspondence between a virtual and a real vascular cast of the kidney; (2) to analyze the arterial anatomy with reference to the renal segments. Fifteen kidneys were injected with acrylic resins to obtain vascular casts, which were also analyzed by computed tomography. A mean of 6.3 (range 4-8) avascular fissures was found, indicating a mean of 7.3 segments (range 5-9). In the superior and middle territories there was a single segment in 4 (26.7%) and 8 (53.3%) cases, respectively, and there were two segments in 11 (73.3%) and in 7 (46.7%) cases, respectively. In the inferior territory there was a single segment in two cases (13.3%), two segments in nine (60%), and three segments in four (26.7%). A mean segmental volume of 550.5 mm3 was calculated; the posterior (1,030.1 mm3 , 28.9%) and inferior (450.3 mm3 , 24.2%) segments were the largest. More third order branches were identified in the inferior segments than in the other segments (three branches of the inferior segmental artery in 26.6%). According to these data the inferior segment occupies the inferior pole, extending both anteriorly and posteriorly. In conclusion, the high correspondence between a virtual and a real vascular cast permits more segments to be identified than those described by Graves, and the volume of each segment can be calculated. Clin. Anat., 2018. © 2018 Wiley Periodicals, Inc.


Assuntos
Rim/irrigação sanguínea , Idoso , Molde por Corrosão , Feminino , Humanos , Imageamento Tridimensional , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
9.
J Anat ; 232(5): 739-746, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29441571

RESUMO

Morphological analyses of cerebral vascularization are not only important for the characterization of the anatomical and physiological relationships between vascular and nervous tissue, but also required to understand structural modifications that occur in many pathological conditions affecting the brain. The aim of this study was to generate a three-dimensional vascular map of the cerebral hemispheres in the nude mouse brain, a widely used animal model for studying tumour biology. We used the corrosion casting (CC) technique to isolate blood vessels from 30 nude mouse brains. All casts were analysed using scanning electron microscopy (SEM), which generated quantitative data regarding vessel length and diameter as well as inter-vascular and inter-branching distances. We identified three different topographical regions: (i) the cortical region, characterized by a superficial wide sheet of vessels giving rise to terminal perforant vessels that penetrate the grey matter; (ii) the inner part of the grey matter, in which dense capillary nets form many flake-like structures extending towards the grey-white matter boundary, where perforant vessels finally change direction and form a well-defined vascular sheet; and (iii) the white matter layer, characterized by a more disorganized vascular architecture. In this study, we demonstrate the accuracy of the CC-SEM method in revealing the 3D-topographical organization of the vascular network of the normal nude mouse brain. These baseline data will serve as a reference for future anatomical investigations of pathological alterations, such as tumour infiltrations, using the nude mouse model.


Assuntos
Córtex Cerebral/irrigação sanguínea , Camundongos Nus/anatomia & histologia , Animais , Molde por Corrosão , Masculino , Camundongos Endogâmicos BALB C , Microscopia Eletrônica de Varredura
10.
Microvasc Res ; 118: 128-136, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29577940

RESUMO

The aim of this study was to analyze the development of vascular architecture as well as vascular morphometry and morphology of anastomosed microvascular free flaps. Free pectoral skin flaps were raised in 25 rats and anastomosed to the femoral vessels in the groin region. CD31 immunohistology was performed after 3, 7 and 12 d (each 5 animals each) to analyze microvessel density (MVD), microvessel area (MVA) and microvessel size (MVS). Microvascular corrosion casting was performed after 7 and 12 d (5 animals each) to analyze vessel diameter (VD), intervascular distance (IVD), interbranching distance (IBD), and branching angle (BA). Further on, sprout and pillar density as hallmarks of sprouting and intussusceptive angiogenesis were analyzed. Pectoral skin isles from the contralateral side served as controls. A significantly increased MVD was found after 7 and 12 d (p each <0.001). MVA was significantly increased after 3, 7 and 12 d (p each <0.001) and a significantly increased MVS was analyzed after 3 and 7 d (p each <0.001). VD and IVD were significantly increased after 7 and 12 d (p each <0.001). For IBD, a significantly increase was measured after 7 d (p < 0.001). For IBA, sprout and pillar density, no significant differences were found (p each ≥0.05). Significant changes in the vascular architecture of free flaps after successful microvascular anastomosis were seen. Since there was no evidence for sprout and pillar formation within the free flaps, the increased MVD and flap revascularization might be induced by the receiving site.


Assuntos
Retalhos de Tecido Biológico/irrigação sanguínea , Microvasos/fisiologia , Neovascularização Fisiológica , Pele/irrigação sanguínea , Anastomose Cirúrgica , Animais , Biomarcadores/metabolismo , Molde por Corrosão , Artéria Femoral/cirurgia , Veia Femoral/cirurgia , Retalhos de Tecido Biológico/cirurgia , Masculino , Microvasos/anatomia & histologia , Microvasos/metabolismo , Microvasos/cirurgia , Modelos Animais , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Ratos Sprague-Dawley , Fatores de Tempo
11.
Clin Anat ; 31(4): 544-550, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29446119

RESUMO

The complex arterial system makes pancreatic interventions technically challenging for surgeons, and interventional radiologists. The arterial variants may alter tumor resecability, and cause complications in arterial embolization. International data on pancreatic blood supply are variable; therefore, we aimed to determine the frequency of variants of pancreaticoduodenal (PD) arterial arcades. Arteries of human abdominal organ complexes (50) were injected with resin mixture, and then corroded. CT scans and three-dimensional reconstructions were made; diameters of arcades were measured. Two PD arcades were found in 58%, three arcades in 30%, one arcade in three cases, four arcade in one specimen, and five arcades in two cases. In the casts with two arches the average diameter was 1.472 ± 0.432 mm on the anterior and 1.383 ± 0.343 mm on the posterior arch. Assessing the dominance of the PD arcades, the anterior arch proved to be dominant in 52% of the cases, and in 35% the posterior one by the criterion of 25% cross-section difference. It is advised to analyze the variations and dominance on a CT/MR-angiography before local chemotherapy. Furthermore, to reveal the arterial variations, a preoperative CT/MR-angiography would provide faster recuperation and better postoperative life quality. Clin. Anat. 31:544-550, 2018. © 2018 Wiley Periodicals, Inc.


Assuntos
Artérias/anatomia & histologia , Duodeno/irrigação sanguínea , Pâncreas/irrigação sanguínea , Molde por Corrosão , Humanos
12.
Surg Radiol Anat ; 40(4): 395-400, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28889187

RESUMO

PURPOSE: To measure the distance between the right and middle hepatic veins and portal vein branches, in human cirrhotic liver casts. Was this measure actually smaller in the cirrhotic liver than in normal one? MATERIALS AND METHODS: This study was authorized by an area Research Ethics Committee, and each study subject or legal representative granted signed informed consent. Acrylic corrosion casts of 21 resected cirrhotic livers were generated. Diameters of hepatic veins and portal branches and pertinent intervening distances were measured. To assess differences in estimated average (relative to reference values), Student's t test for one sample was applied. RESULTS: Mean distances from right hepatic vein to the right portal branch and to portal vein bifurcation were 33 ± 6.4 and 36 ± 7.4 mm, respectively, both significantly less than published reference values in healthy human livers (p < 0.0001 and p < 0.0002, respectively). Mean distances from middle hepatic vein to right and left branches of portal vein were 36 ± 6.8 and 26 ± 8.8 mm, respectively. CONCLUSION: Distances separating right hepatic vein and portal vein (right branch and bifurcation) are diminished in cirrhotic livers compared to healthy ones. Given its caliber and proximity to portal branches, the middle hepatic vein remains as a reasonable alternative for TIPS procedures.


Assuntos
Veias Hepáticas/anatomia & histologia , Cirrose Hepática/patologia , Veia Porta/anatomia & histologia , Molde por Corrosão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Derivação Portossistêmica Transjugular Intra-Hepática
13.
Folia Morphol (Warsz) ; 77(4): 649-655, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29611162

RESUMO

BACKGROUND: Surgical procedures such as thenar flaps and radial artery (RA) harvesting call for an elaborate anatomical study of the RA's superficial palmar branch (SPB). The aim of this study was to describe the branching pattern of this vessel related to the morphometric characteristics and variations of this artery. MATERIALS AND METHODS: Twenty 4% formalin solution-injected hands were dissected. For the morphometric study we used another group of 35 human hands of adult persons, injected with methyl methacrylate fluid into the ulnar and radial arteries. As soon as polymerisation was completed, a 40% solution of potassium hydroxide was applied for corrosion. The vascular arterial casts were examined under the stereoscopic microscope and precise drawings of each specimen were made. RESULTS: In the majority of cases (75%) SPB passed superficially, over the abductor pollicis brevis muscle. The mean diameter of the SPB, very variable depending on its length and field of supply, was 1.52 ± 0.49 mm, ranging from 0.8 to 2.7 mm. Developed SPB type, was present in 31.4% of hands, with the diameter of 1.7 mm and larger (mean 1.95 mm), continuing distally to become the radialis indicis artery, with an average calibre of 1.2 mm, and with important branches to the thumb. In most hands (68.6%), the hypoplastic SPB, was present, with a mean diameter of 1.17 mm, and the field of supply within the thenar area. CONCLUSIONS: Knowledge of the SPB dominance and existence of anastomotic vessels in its field of supply are of importance to avoid the risk of possible ischaemic sequelae in the hand associated with harvesting the RA.


Assuntos
Molde por Corrosão , Mãos/anatomia & histologia , Artéria Radial/anatomia & histologia , Adulto , Dissecação , Feminino , Mãos/irrigação sanguínea , Humanos , Masculino
14.
Rozhl Chir ; 97(5): 222-228, 2018.
Artigo em Tcheco | MEDLINE | ID: mdl-29792720

RESUMO

INTRODUCTION: Corrosion casts (CCs) are used for the visualization and assessment of hollow structures. CCs with filled capillaries enable (with the help of imaging methods) to obtain data for mathematical organ perfusion modelling. As the processing is more difficult in case of organs with greater volume of the vasculature, mainly organs from small animals have been cast up to now. The aim of this study was to optimize the protocol of corrosion casting of different organs of pig. Porcine organs are relatively easily accessible and frequently used in experimental medicine. METHOD: Organs from 10 healthy Prestice Black-Pied pigs (6 females, body weight 35-45 kg), were used in this study (liver, spleen, kidneys and small intestine). The organs were dissected, heparin was administered into the systemic circulation and then the vascular bed of the organs was flushed with heparinized saline either in situ (liver) or after their removal (spleen, kidney, small intestine). All handling was done under the water surface to prevent air embolization. The next step was an intraarterial (in case of the liver also intraportal) administration of Biodur E20® (Heidelberg, Germany) resin. After hardening of the resin the organ tissue was dissolved by 15% KOH and the specimen was rinsed with tap water. Voluminous casts were stored in 70% denatured alcohol, the smaller ones were lyophilized. The casts were assessed with a stereomicroscope, computed and microcomputed tomography (CT and microCT), a scanning electron microscope (SEM) and high-resolution digital microscope (HRDM). RESULTS: High-quality CCs of the porcine liver, kidneys, spleen and small intestine were created owing to the sophisticated organ harvesting, the suitable resin and casting procedure. Macroscopic clarity was improved thanks to the possibility of resin dying. Scanning by CT was performed and showed to be a suitable method for the liver cast examination. MicroCT, SEM and HRDM produced images of the most detailed structures of vascular bed. Despite the fact that SEM seems to be an irreplaceable method for CCs quality control, it seems that this modality could be partly replaced by HRDM. MicroCT enabled to obtain data about three-dimensional layout of the vascular bed and data for mathematical modelling of organ perfusion. With regard to the quality of the CCs, they could also be used to teach human anatomy. CONCLUSIONS: The protocol of the corrosion casting of the porcine liver, kidneys, spleen and small intestine CCs was optimized. Thanks to different imaging methods, the CCs can be used as a source of data on three-dimensional architecture of the vascular bed. These data can be used for mathematical modeling of organ perfusion which can be helpful for example for optimization of organ resections.Key words: corrosion casts microvasculature Biodur E20® domestic pig animal model.


Assuntos
Molde por Corrosão , Microscopia Eletrônica de Varredura , Microtomografia por Raio-X , Estruturas Animais , Animais , Corrosão , Feminino , Humanos
15.
J Anat ; 230(3): 471-483, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27995631

RESUMO

The intricate (micro)vascular architecture of the liver has not yet been fully unravelled. Although current models are often idealized simplifications of the complex anatomical reality, correct morphological information is instrumental for scientific and clinical purposes. Previously, both vascular corrosion casting (VCC) and immunohistochemistry (IHC) have been separately used to study the hepatic vasculature. Nevertheless, these techniques still face a number of challenges such as dual casting in VCC and limited imaging depths for IHC. We have optimized both techniques and combined their complementary strengths to develop a framework for multilevel reconstruction of the hepatic circulation in the rat. The VCC and micro-CT scanning protocol was improved by enabling dual casting, optimizing the contrast agent concentration, and adjusting the viscosity of the resin (PU4ii). IHC was improved with an optimized clearing technique (CUBIC) that extended the imaging depth for confocal microscopy more than five-fold. Using in-house developed software (DeLiver), the vascular network - in both VCC and IHC datasets - was automatically segmented and/or morphologically analysed. Our methodological framework allows 3D reconstruction and quantification of the hepatic circulation, ranging from the major blood vessels down to the intertwined and interconnected sinusoids. We believe that the presented framework will have value beyond studies of the liver, and will facilitate a better understanding of various parenchymal organs in general, in physiological and pathological circumstances.


Assuntos
Molde por Corrosão/métodos , Imageamento Tridimensional/métodos , Imuno-Histoquímica/métodos , Fígado/irrigação sanguínea , Microtomografia por Raio-X/métodos , Animais , Masculino , Modelos Anatômicos , Modelos Animais , Ratos , Ratos Wistar
16.
Microsc Microanal ; 23(1): 77-87, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28228173

RESUMO

Development of collateral vessels, arteriogenesis, may protect against tissue ischemia, however, quantitative data on this process remain scarce. We have developed a technique for replicating the entire arterial network of ischemic rat hindlimbs in three dimensions (3D) based on vascular casting and automated sequential cryo-imaging. Various dilutions of Batson's No. 17 with methyl methacrylate were evaluated in healthy rats, with further protocol optimization in ischemic rats. Penetration of the resin into the vascular network greatly depended on dilution; the total length of casted vessels below 75 µm was 13-fold higher at 50% dilution compared with the 10% dilution. Dilutions of 25-30%, with transient clamping of the healthy iliac artery, were optimal for imaging the arterial network in unilateral ischemia. This protocol completely filled the lumina of small arterioles and collateral vessels. These appeared as thin anastomoses in healthy legs and increasingly larger vessels during ligation (median diameter 1 week: 63 µm, 4 weeks: 127 µm). The presented combination of quality casts with high-resolution cryo-imaging enables automated, detailed 3D analysis of collateral adaptation, which furthermore can be combined with co-registered 3D distributions of fluorescent molecular imaging markers reflecting biological activity or perfusion.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/patologia , Membro Posterior/irrigação sanguínea , Membro Posterior/diagnóstico por imagem , Imageamento Tridimensional/métodos , Isquemia/diagnóstico por imagem , Isquemia/patologia , Animais , Arteríolas/diagnóstico por imagem , Arteríolas/patologia , Molde por Corrosão , Resinas Epóxi , Técnicas Histológicas/métodos , Ligadura , Masculino , Metilmetacrilatos/química , Ratos , Ratos Sprague-Dawley
17.
Folia Morphol (Warsz) ; 76(2): 232-238, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28026846

RESUMO

BACKGROUND: The aim of this study was to clarify the arterial supply of the skin covering the prominent part of the thenar eminence in order to describe the possibility and potential for harvesting a pedicled or a free flap from the thenar eminence. MATERIALS AND METHODS: The arteries were studied in 30 post-mortem specimens of human hands; 3 previously perfused with 4% formaldehyde solution, and injected with black India ink, and 27 injected with methyl-methacrylate and afterwards corroded in 40% potassium hydroxide solution. RESULTS: In all hands we found two little palmar arteries coming from the anatomical snuff-box portion of the radial artery. We labelled the first (proximal) branch as the middle thenar artery, because it supplies the middle third of the thenar eminence skin. Its diameter varied from 0.25 to 0.55 mm (mean 0.4 mm). The distal, more prominent branch of the radial artery, vascularised the lateral third of the thenar eminence skin, and was named the lateral thenar artery; its diameter ranged from 0.40 to 0.90 mm (mean 0.67 mm). The superficial palmar branch of the radial artery, always present, was classified as: hypoplastic, average or prominent, with a diameter ranging from 0.8 to 2.7 mm (mean 1.47 mm). CONCLUSIONS: Three individually developed branches of the radial artery supplied the skin of the thenar eminence. Cutaneous branches of these three arteries were interconnected via anastomotic vessels.


Assuntos
Retalhos de Tecido Biológico , Mãos/anatomia & histologia , Mãos/irrigação sanguínea , Adulto , Molde por Corrosão , Dissecação , Feminino , Mãos/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
18.
Folia Morphol (Warsz) ; 75(2): 154-161, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26542961

RESUMO

BACKGROUND: Pigs are frequently used as animal models in experimental medicine. To identify processes of vascular development or regression, vascular elements must be recognised and quantified in a three-dimensional (3D) arrangement. Vascular corrosion casts enable the creation of 3D replicas of vascular trees. The aim of our study was to identify suitable casting media and optimise the protocol for porcine liver vascular corrosion casting. MATERIALS AND METHODS: Mercox II® (Ladd Research, Williston, Vermont, USA) and Biodur E20® Plus (Biodur Products, Heidelberg, Germany) were tested in 4 porcine livers. The resins (volume approximately 700 mL) were injected via the portal vein. Corrosion casts were examined by macro-computed tomography, micro-computed tomography and scanning electron microscopy. RESULTS: For hepatectomies, the operating protocol was optimised to avoid gas or blood clot embolisation. We present a protocol for porcine liver vascular bed casting based on corrosion specimens prepared using Biodur E20® epoxy resin. CONCLUSIONS: Only Biodur E20®Plus appeared to be suitable for high-volume vascular corrosion casting due to its optimal permeability, sufficient processing time and minimum fragility. Biodur E20® Plus is slightly elastic, radio-opaque and alcohol-resistant. These properties make this acrylic resin suitable for not only vascular research but also teaching purposes.


Assuntos
Fígado/irrigação sanguínea , Animais , Capilares , Corrosão , Molde por Corrosão , Microscopia Eletrônica de Varredura , Suínos , Microtomografia por Raio-X
19.
Microvasc Res ; 102: 78-85, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26365474

RESUMO

BACKGROUND: Lymphedema is an underdiagnosed pathology which in industrialized countries mainly affects cancer patients that underwent lymph node dissection and/or radiation. Currently no effective therapy is available so that patients' life quality is compromised by swellings of the concerned body region. This unfortunate condition is associated with body imbalance and subsequent osteochondral deformations and impaired function as well as with an increased risk of potentially life threatening soft tissue infections. METHODS: The effects of PRP and ASC on angiogenesis (anti-CD31 staining), microcirculation (Laser Doppler Imaging), lymphangiogenesis (anti-LYVE1 staining), microvascular architecture (corrosion casting) and wound healing (digital planimetry) are studied in a murine tail lymphedema model. RESULTS: Wounds treated by PRP and ASC healed faster and showed a significantly increased epithelialization mainly from the proximal wound margin. The application of PRP induced a significantly increased lymphangiogenesis while the application of ASC did not induce any significant change in this regard. CONCLUSIONS: PRP and ASC affect lymphangiogenesis and lymphedema development and might represent a promising approach to improve regeneration of lymphatic vessels, restore disrupted lymphatic circulation and treat or prevent lymphedema alone or in combination with currently available lymphedema therapies.


Assuntos
Tecido Adiposo/citologia , Linfangiogênese , Linfedema/terapia , Transplante de Células-Tronco Mesenquimais , Plasma Rico em Plaquetas , Células-Tronco Adultas/transplante , Animais , Molde por Corrosão , Modelos Animais de Doenças , Humanos , Vasos Linfáticos/patologia , Vasos Linfáticos/fisiopatologia , Linfedema/patologia , Linfedema/fisiopatologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica de Varredura , Regeneração , Cauda
20.
Transpl Int ; 28(10): 1216-26, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26152659

RESUMO

The purpose of our study was to investigate the anatomical variations of the extrahepatic arterial structures of the liver with particular attention to rare variations and their potential impact on liver surgery. A total of 50 human abdominal organ complexes were used to prepare corrosion casts. A multicomponent resin mixture was injected into the abdominal aorta. The portal vein was injected with a different colored resin in 16 cases. Digestion of soft tissues was achieved using cc. KOH solution at 60-65 °C. Extrahepatic arterial variations were classified according to Michels. All specimens underwent 3D volumetric CT reconstruction. Normal anatomy was seen in 42% of cases, and variants were seen in the other 58%. No Michels type VI or X variations were present; however, in 18% of cases the extrahepatic arterial anatomy did not fit into Michels' classification. We report four new extrahepatic arterial variations. In contrast to the available data, normal anatomy was found much less frequently, whereas the prevalence of unclassified arterial variations was higher. We detected four previously unknown variations. Our data may contribute to the reduction of complications during surgical and radiological interventions in the upper abdomen.


Assuntos
Artérias/anormalidades , Fígado/irrigação sanguínea , Angiografia , Aorta Abdominal/anatomia & histologia , Classificação , Anormalidades Congênitas/epidemiologia , Molde por Corrosão , Artéria Hepática/anormalidades , Artéria Hepática/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Fígado/cirurgia , Artéria Mesentérica Superior/anormalidades , Artéria Mesentérica Superior/diagnóstico por imagem , Veia Porta/anatomia & histologia , Prevalência , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA