Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.675
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res Treat ; 205(1): 109-116, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38308767

RESUMO

BACKGROUND: Understanding the factors influencing nodal status in breast cancer is vital for axillary staging, therapy, and patient survival. The nodal stage remains a crucial factor in prognostication indices. This study investigates the relationship between tumour-to-skin distance (in T1-T3 tumours where the skin is not clinically involved) and the risk of nodal metastasis. METHODS: We retrospectively reviewed data from 100 patients who underwent neoadjuvant chemotherapy (NACT). Besides patient demographics and tumour variables, a radiologist retrospectively reviewed pre-operative MRI to measure tumour-to-skin distance. R core packages were used for univariate (χ2 and T-Wilcoxon tests) and bivariate logistic regression statistical analysis. RESULTS: Of 95 analysable datasets, patients' median age was 51 years (IQR: 42-61), 97% were symptomatic (rest screen detected), and the median tumour size was 43 mm (IQR, 26-52). On multivariate analysis, increasing invasive tumour size (p = 0.02), ER positivity (p = 0.007) and shorter tumour-to-skin distance (p = 0.05) correlated with nodal metastasis.  HER2 was not included in multivariate analysis as there was no association with nodal status on univariate analysis. In node-positive tumours, as tumour size increased, the tumour-to-skin distance decreased (r = - 0.34, p = 0.026). In node-negative tumours, there was no correlation (r = + 0.18, p = 0.23). CONCLUSION: This study shows that non-locally advanced cancers closer to the skin (and consequent proximity to subdermal lymphatics) are associated with a greater risk of nodal metastasis. Pre-operative identification of those more likely to be node positive may suggest the need for a second-look USS since a higher nodal stage may lead to a change in therapeutic strategies, such as upfront systemic therapy, node marking, and axillary clearance without the need to return to theatre following sentinel node biopsy.


Assuntos
Neoplasias da Mama , Metástase Linfática , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/patologia , Adulto , Estudos Retrospectivos , Terapia Neoadjuvante/métodos , Estadiamento de Neoplasias , Prognóstico , Pele/patologia , Pele/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Linfonodos/patologia , Axila , Carga Tumoral
2.
Breast Cancer Res Treat ; 206(3): 575-583, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38662118

RESUMO

PURPOSE: The skin and/or nipple-sparing approach has become an oncologically sound and desirable choice for women choosing mastectomy. Indocyanine green (ICG) perfusion imaging has been shown to reduce ischemic complications in mastectomy skin flaps. Immediate reconstruction requires a well-vascularized skin flap capable of tolerating full expansion. Identification of the perforating subcutaneous vessels to the skin envelope may allow for better and more consistent blood vessel preservation and flap perfusion. METHODS: The authors conducted an institutional review board-approved prospective study with 41 patients to assess the feasibility of using ICG perfusion imaging to visualize, cutaneously map, and preserve the vessels that supply the skin flap and nipple-areolar complex. For each patient, the number of vessels initially mapped, the number of vessels preserved, the extent to which each vessel was preserved, and the proportion of the flap with adequate perfusion (as defined by the SPY-Q > 20% threshold) was recorded and analyzed. RESULTS: Vessels were able to be identified and marked in a high majority of patients (90%). There was a moderate linear relationship between the number of vessels marked and the number preserved. Successful mapping of vessels was associated with lower rates of wound breakdown (p = 0.036). Mapping and preserving at least one vessel led to excellent flap perfusion (> 90%). No increase in complications was observed from utilizing ICG angiography preoperatively. CONCLUSION: This prospective study using preoperative ICG perfusion mapping demonstrated safety, feasibility, and good prognostic outcomes. LEVEL OF EVIDENCE: III.


Assuntos
Neoplasias da Mama , Verde de Indocianina , Mamilos , Humanos , Feminino , Mamilos/cirurgia , Mamilos/irrigação sanguínea , Pessoa de Meia-Idade , Neoplasias da Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Adulto , Idoso , Retalhos Cirúrgicos/irrigação sanguínea , Angiografia/métodos , Estudos Prospectivos , Mastectomia/métodos , Mastectomia/efeitos adversos , Pele/irrigação sanguínea , Pele/diagnóstico por imagem , Mamoplastia/métodos , Tratamentos com Preservação do Órgão/métodos
3.
Magn Reson Med ; 92(1): 430-439, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38411265

RESUMO

PURPOSE: Electron spin resonance (ESR) is used to measure oxygen partial pressure (pO2) in biological media with many clinical applications. Traditional clinical ESR involves large magnets that encompass the subject of measurement. However, certain applications might benefit from a scanner operating within local static magnetic fields. Our group recently developed such a compact scanner for transcutaneous (surface) pO2 measurements of skin tissue. Here we extend this capability to subsurface (subcutaneous) pO2 measurements and verify it using an artificial tissue emulating (ATE) phantom. METHODS: We introduce a new scanner, tailored for subcutaneous measurements up to 2 mm beneath the skin's surface. This scanner captures pulsed ESR signals from embedded approximate 1-mm oxygen-sensing solid paramagnetic implant, OxyChip. The scanner features a static magnetic field source, producing a uniform region outside its surface, and a compact microwave resonator, for exciting and receiving ESR signals. RESULTS: ESR readings derived from an OxyChip, positioned approximately 1.5 mm from the scanner's surface, embedded in ATE phantom, exhibited a linear relation of 1/T2 versus pO2 for pO2 levels at 0, 7.6, 30, and 160 mmHg, with relative reading accuracy of about 10%. CONCLUSION: The compact ESR scanner can report pO2 data in ATE phantom from an external position relative to the scanner. Implementing this scanner in preclinical and clinical applications for subcutaneous pO2 measurements is a feasible next phase for this development. This innovative design also has the potential to operate in conjunction with artificial skin graft for wound healing, combining therapeutic and pO2 diagnostic features.


Assuntos
Oximetria , Oxigênio , Imagens de Fantasmas , Espectroscopia de Ressonância de Spin Eletrônica , Oximetria/métodos , Humanos , Desenho de Equipamento , Pele/diagnóstico por imagem
4.
Exp Dermatol ; 33(1): e14962, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37950549

RESUMO

Far-infrared radiation (FIR) has been investigated for reduction of pain and improvement of dermal blood flow. The FIRTECH patch is a medical device designed to re-emit FIR radiated by the body. This phase 1 study was conducted to evaluate the local effects of the FIRTECH patch on local skin perfusion, microcirculation and oxygenation. This prospective, randomized, open-label, parallel designed study admitted 20 healthy participants to a medical research facility for treatment for 31 h on three anatomical locations. During treatment, imaging assessments consisting of laser speckle contrast imaging, near-infrared spectroscopy, side-stream dark-field microscopy, multispectral imaging and thermography were conducted regularly on patch-treated skin and contralateral non-treated skin. The primary endpoint was baseline perfusion increase during treatment on the upper back. Secondary endpoints included change in baseline perfusion, oxygen consumption and temperature of treated versus untreated areas. The primary endpoint was not statistically significantly different between treated and non-treated areas. The secondary endpoints baseline perfusion on the forearm (least square means [LSMs] difference 2.63 PU, 95% CI: 0.97, 4.28), oxygen consumption (LSMs difference: 0.42 arbitrary units [AUs], 95% CI: 0.04, 0.81) and skin temperature (LSMs difference 0.35°C, 95% CI: 0.16, 0.6) were statistically significantly higher in treated areas. Adverse events observed during the study were mild and transient. The vascular response to the FIRTECH patch was short-lived suggesting a non-thermal vasodilatory effect of the patch. The FIRTECH patch was well tolerated, with mild and transient adverse events observed during the study. These results support the therapeutic potential of FIR in future investigations.


Assuntos
Temperatura Cutânea , Pele , Humanos , Microcirculação/fisiologia , Estudos Prospectivos , Pele/diagnóstico por imagem , Pele/irrigação sanguínea , Perfusão/métodos
5.
Exp Dermatol ; 33(1): e14971, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37909707

RESUMO

Atopic dermatitis (AD) is a chronic, recurrent eczematous disorder with a complex pathophysiology caused by skin barrier abnormalities. Rosacea is a common chronic immune-mediated inflammatory disorder that results in diminished skin barrier function. Reflectance confocal microscopy (RCM) is a non-invasive method for visualizing the dynamic status of epidermal and upper dermal structures. In this study, we compared skin barrier permeability among normal, AD and rosacea groups. To assess skin barrier permeability, zinc was applied to lesional skin and the RCM reflectance intensity of zinc penetration was measured. Reflectance confocal microscopy revealed that the intensity in patients with rosacea and AD was higher than that in the normal group at depths of 8-24 µm in both the face and forearm, which were considered as the stratum corneum (SC) and tight junction (TJ) level (p < 0.0001). When comparing AD and rosacea, the intensity of rosacea was higher than that of AD at a depth of 8 µm in the face (p < 0.0001). The intensity of AD was higher than that of rosacea at a depth of 24 µm (p = 0.009). This suggests that skin barrier permeability is increased in the upper epidermis of patients with AD and rosacea. On the face, patients with rosacea had more SC weakness than did those with AD, whereas patients with AD had more TJ weakness than those with rosacea.


Assuntos
Dermatite Atópica , Rosácea , Humanos , Dermatite Atópica/diagnóstico por imagem , Zinco , Epiderme/diagnóstico por imagem , Rosácea/diagnóstico por imagem , Microscopia Confocal , Pele/diagnóstico por imagem
6.
Exp Dermatol ; 33(4): e15076, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38610095

RESUMO

Nonmelanoma skin cancers remain the most widely diagnosed types of cancers globally. Thus, for optimal patient management, it has become imperative that we focus our efforts on the detection and monitoring of cutaneous field carcinogenesis. The concept of field cancerization (or field carcinogenesis), introduced by Slaughter in 1953 in the context of oral cancer, suggests that invasive cancer may emerge from a molecularly and genetically altered field affecting a substantial area of underlying tissue including the skin. A carcinogenic field alteration, present in precancerous tissue over a relatively large area, is not easily detected by routine visualization. Conventional dermoscopy and microscopy imaging are often limited in assessing the entire carcinogenic landscape. Recent efforts have suggested the use of noninvasive mesoscopic (between microscopic and macroscopic) optical imaging methods that can detect chronic inflammatory features to identify pre-cancerous and cancerous angiogenic changes in tissue microenvironments. This concise review covers major types of mesoscopic optical imaging modalities capable of assessing pro-inflammatory cues by quantifying blood haemoglobin parameters and hemodynamics. Importantly, these imaging modalities demonstrate the ability to detect angiogenesis and inflammation associated with actinically damaged skin. Representative experimental preclinical and human clinical studies using these imaging methods provide biological and clinical relevance to cutaneous field carcinogenesis in altered tissue microenvironments in the apparently normal epidermis and dermis. Overall, mesoscopic optical imaging modalities assessing chronic inflammatory hyperemia can enhance the understanding of cutaneous field carcinogenesis, offer a window of intervention and monitoring for actinic keratoses and nonmelanoma skin cancers and maximise currently available treatment options.


Assuntos
Sinais (Psicologia) , Neoplasias Cutâneas , Humanos , Neoplasias Cutâneas/diagnóstico por imagem , Carcinogênese , Pele/diagnóstico por imagem , Carcinógenos , Inflamação/diagnóstico por imagem , Microambiente Tumoral
7.
J Am Acad Dermatol ; 90(3): 537-544, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37898340

RESUMO

BACKGROUND: No international recommendations exist for a minimum imaging requirement per lesion using reflectance confocal microscopy (RCM). This may be beneficial given the increasing use of remote RCM interpretation internationally. OBJECTIVE: To develop international expert recommendations for image acquisition using tissue-coupled RCM for diagnosis of cutaneous tumors. METHODS: Using a modified Delphi approach, a core group developed the scope and drafted initial recommendations before circulation to a larger group, the Cutaneous Imaging Expert Resource Group of the American Academy of Dermatology. Each review round consisted of a period of open comment, followed by revisions. RESULTS: The recommendations were developed after 5 alternating rounds of review among the core group and the Cutaneous Imaging Expert Resource Group. These were divided into subsections of imaging personnel, recommended lesion criteria, clinical and lesion information to be provided, lesion preparation, image acquisition, mosaic cube settings, and additional captures based on lesion characteristics and suspected diagnosis. LIMITATIONS: The current recommendations are limited to tissue-coupled RCM for diagnosis of cutaneous tumors. It is one component of the larger picture of quality assurance and will require ongoing review. CONCLUSIONS: These recommendations serve as a resource to facilitate quality assurance, economical use of time, accurate diagnosis, and international collaboration.


Assuntos
Dermoscopia , Neoplasias Cutâneas , Humanos , Dermoscopia/métodos , Neoplasias Cutâneas/patologia , Pele/diagnóstico por imagem , Pele/patologia , Microscopia Intravital , Microscopia Confocal/métodos
8.
J Am Acad Dermatol ; 91(1): 37-42, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38365092

RESUMO

BACKGROUND: For the treatment of vascular adverse events caused by filler injections, duplex ultrasound imaging may be used. The findings of duplex ultrasound examination and the clinical features of reticulated livedoid skin patterns were compared with the hemifaces anatomy. OBJECTIVE: The objective of this study was to link the reticulated livedoid skin patterns to the corresponding duplex ultrasound findings and the facial perforasomes. METHODS: Duplex ultrasound imaging was used for the diagnosis and treatment of vascular adverse events. The clinical features and duplex ultrasound findings of 125 patients were investigated. Six cadaver hemifaces were examined to compare the typical livedo skin patterns with the vasculature of the face. RESULTS: Clinically, the affected skin showed a similar reticulated pattern in each facial area corresponding with arterial anatomy and their perforators in the cadaver hemifaces. With duplex ultrasound, a disturbed microvascularization in the superficial fatty layer was visualized. After hyaluronidase injection, clinical improvement of the skin pattern was seen. Normalization of blood flow was noted accompanied by restoration of flow in the corresponding perforator artery. The skin patterns could be linked to the perforators of the superficial fat compartments. CONCLUSION: The livedo skin patterns seen in vascular adverse events may reflect the involvement of the perforators.


Assuntos
Preenchedores Dérmicos , Livedo Reticular , Humanos , Preenchedores Dérmicos/efeitos adversos , Preenchedores Dérmicos/administração & dosagem , Feminino , Pessoa de Meia-Idade , Masculino , Adulto , Livedo Reticular/patologia , Ultrassonografia Doppler Dupla , Cadáver , Idoso , Face/irrigação sanguínea , Técnicas Cosméticas/efeitos adversos , Hialuronoglucosaminidase/administração & dosagem , Pele/irrigação sanguínea , Pele/patologia , Pele/diagnóstico por imagem
9.
Skin Res Technol ; 30(3): e13654, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38504440

RESUMO

BACKGROUND/PURPOSE: Skin elasticity was used to evaluate healthy and diseased skin. Correlation analysis between image texture characteristics and skin elasticity was performed to study the feasibility of assessing skin elasticity using a non-contact method. MATERIALS AND METHODS: Skin images in the near-infrared band were acquired using a hyperspectral camera, and skin elasticity was obtained using a skin elastimeter. Texture features of the mean, standard deviation, entropy, contrast, correlation, homogeneity, and energy were extracted from the acquired skin images, and a correlation analysis with skin elasticity was performed. RESULTS: The texture features, and skin elasticity of skin images in the near-infrared band had the highest correlation on the side of eye and under of arm, and the mean and correlation were features of texture suitable for distinguishing skin elasticity according to the body part. CONCLUSION: In this study, we performed elasticity and correlation analyses for various body parts using the texture characteristics of skin hyperspectral images in the near-infrared band, confirming a significant correlation in some body parts. It is expected that this will be used as a cornerstone of skin elasticity evaluation research using non-contact methods.


Assuntos
Pele , Humanos , Pele/diagnóstico por imagem , Elasticidade
10.
Skin Res Technol ; 30(3): e13622, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38500350

RESUMO

BACKGROUND AND OBJECTIVE: Skin thermal diffusivity plays a crucial role in various applications, including laser therapy and cryogenic skin cooling.This study investigates the correlation between skin thermal diffusivity and two important skin parameters, melanin content and erythema, in a cohort of 102 participants. METHODS: An in-house developed device based on transient temperature measurement was used to assess thermal diffusivity at different body locations. Melanin content and erythema were measured using a colorimeter. Statistical analysis was performed to examine potential correlations. RESULTS: The results showed that the measured thermal diffusivity values were consistent with previous reports, with variations observed among subjects. No significant correlation was found between thermal diffusivity and melanin content or erythema. This suggests that other factors, such as skin hydration or epidermis thickness, may have a more dominant influence on skin thermal properties. CONLCUSION: This research provides valuable insights into the complex interplay between skin thermal properties and physiological parameters, with potential implications for cosmetic and clinical dermatology applications.


Assuntos
Melaninas , Pigmentação da Pele , Humanos , Pele/diagnóstico por imagem , Eritema , Epiderme
11.
Skin Res Technol ; 30(2): e13565, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38279539

RESUMO

BACKGROUND: The morphology and content of stratum corneum (SC) cells provide information on the physiological condition of the skin. Although the morphological and biochemical properties of the SC are known, no method is available to fully access and interpret this information. This study aimed to develop a method to comprehensively decode the physiological information of the skin, based on the SC. Therefore, we established a novel image analysis technique based on artificial intelligence (AI) and multivariate analysis to predict skin conditions. MATERIALS AND METHODS: SC samples were collected from participants, imaged, and annotated. Nine biomarkers were measured in the samples using enzyme-linked immunosorbent assay. The data were then used to teach machine-learning models to recognize individual SC cell regions and estimate the levels of the nine biomarkers from the images. Skin physiological indicators (e.g., skin barrier function, facial analysis, and questionnaires) were measured or obtained from the participants. Multivariate analysis, including biomarker levels ​​and structural parameters of the SC as variables, was used to estimate these physiological indicators. RESULTS: We established two machine-learning models. The accuracy of recognition was assessed according to the average intersection over union (0.613), precision (0.953), recall (0.640), and F-value (0.766). The predicted biomarker levels significantly correlated with the measured levels. Skin physiological indicators and questionnaire answers were predicted with strong correlations and correct answer rates. CONCLUSION: Various physiological skin conditions can be predicted from images of the SC using AI models and multivariate analysis. Our method is expected to be useful for dermatological treatment optimization.


Assuntos
Inteligência Artificial , Pele , Humanos , Pele/diagnóstico por imagem , Epiderme , Aprendizado de Máquina , Biomarcadores
12.
Skin Res Technol ; 30(6): e13773, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38863083

RESUMO

BACKGROUND: Skin barrier function is significantly impacted by skin moisture. Most non-invasive evaluation techniques to measure skin surface hydration relying on its electrical properties, which are limited in scope and have unstable operations. Applying image processing for skin hydration assessment is uncommon, with an emphasis on skin-capacitive pictures and near-infrared images in general, which demand a certain spectrum. As a result, there is an increasing need for wide-area skin hydration evaluation and mapping. OBJECTIVE: The study aims to propose a quantitative evaluation algorithm for skin surface hydration from visible-light images. MATERIALS AND METHODS: Three devices were applied to measure skin hydration: skin image capture device and two recognized commercial skin devices. A digital image processing system creates a new index, called GVR, to symbolize skin surface moisture. The CLAHE algorithm was applied to enhance the contrast of skin image, and after calculating it with the monochrome image, the skin reflectance image was segmented. The GVR was estimated using the values of the individual sites and the entire skin. The correlation coefficient between the three methods was examined using statistical analysis to assess the performance of GVR. RESULTS: Skin hydration estimated from visible-light images is influenced by the entire facial structure in addition to specific areas. The electrical and visible image evaluations showed a strong association with a significant difference. CONCLUSION: It was discovered that reflecting measures from visible images provide a quick and efficient way to quantify the moisture of the skin's surface.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Pele , Humanos , Projetos Piloto , Adulto , Pele/diagnóstico por imagem , Feminino , Processamento de Imagem Assistida por Computador/métodos , Masculino , Fenômenos Fisiológicos da Pele , Adulto Jovem , Imagem Óptica/métodos
13.
Skin Res Technol ; 30(2): e13566, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38270438

RESUMO

OBJECTIVE: Age-related changes in the fiber structure around adipocytes were investigated via scanning electron microscopy (SEM) of excised skin tissues. In addition, the viscoelasticity of the subcutaneous fat layer was evaluated via elastography, and the association between the fiber structure and the viscoelastic properties was assessed. METHODS: Skin tissues excised from the facial cheek area were used. Then, SEM images of these tissues were obtained. The thickness and quantity of the fibers around adipocytes were assessed using a 5-point scale. The score was used to grade 18 tissue samples. Moreover, the viscoelasticity of the subcutaneous fat layer in the same samples was evaluated via ultrasound elastography. RESULTS: Based on the SEM image score, an association was observed between the fiber status score and age, thereby indicating a tendency toward age-related fibrosis. Fiber structures with high scores, which indicate fibrosis, had a significantly lower viscoelasticity based on ultrasound elastography. CONCLUSION: The thickness and quantity of fibrous structures around adipocytes in the subcutaneous fat layer increase with age, and these changes can be associated with decreased viscoelasticity in the subcutaneous fat layer.


Assuntos
Adipócitos , Pele , Humanos , Pele/diagnóstico por imagem , Bochecha/diagnóstico por imagem , Gordura Subcutânea/diagnóstico por imagem , Fibrose
14.
Skin Res Technol ; 30(4): e13679, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38616503

RESUMO

BACKGROUND: Injectable filler, a nonsurgical beauty method, has gained popularity in rejuvenating sagging skin. In this study, polydioxanone (PDO) was utilized as the main component of the ULTRACOL200 filler that helps stimulate collagenesis and provide skin radiant effects. The study aimed to evaluate and compare the effectiveness of ULTRACOL200 with other commercialized products in visually improving dermatological problems. METHODS: Herein, 31 participants aged between 20 and 59 years were enrolled in the study. 1 mL of the testing product, as well as the quantity for the compared groups was injected into each participants face side individually. Subsequently, skin texture and sunken volume of skin were measured using ANTERA 3D CS imaging technology at three periods: before the application, 4 weeks after the initial application, and 4 weeks after the 2nd application of ULTRACOL200. RESULTS: The final results of skin texture and wrinkle volume evaluation consistently demonstrated significant enhancement. Consequently, subjective questionnaires were provided to the participants to evaluate the efficacy of the testing product, illustrating satisfactory responses after the twice applications. CONCLUSION: The investigation has contributed substantially to the comprehension of a PDO-based filler (ULTRACOL200) for skin enhancement and provided profound insight for future clinical trials.


Assuntos
Sulco Nasogeniano , Transplante de Pele , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Pele/diagnóstico por imagem , Imageamento Tridimensional , Tecnologia
15.
Skin Res Technol ; 30(3): e13613, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38419420

RESUMO

BACKGROUND: Recent advancements in artificial intelligence have revolutionized dermatological diagnostics. These technologies, particularly machine learning (ML), including deep learning (DL), have shown accuracy equivalent or even superior to human experts in diagnosing skin conditions like melanoma. With the integration of ML, including DL, the development of at home skin analysis devices has become feasible. To this end, we introduced the Skinly system, a handheld device capable of evaluating various personal skin characteristics noninvasively. MATERIALS AND METHODS: Equipped with a moisture sensor and a multi-light-source camera, Skinly can assess age-related skin parameters and specific skin properties. Utilizing state-of-the-art DL, Skinly processed vast amounts of images efficiently. The Skinly system's efficacy was validated both in the lab and at home, comparing its results to established "gold standard" methods. RESULTS: Our findings revealed that the Skinly device can accurately measure age-associated parameters, that is, facial age, skin evenness, and wrinkles. Furthermore, Skinly produced data consistent with established devices for parameters like glossiness, skin tone, redness, and porphyrin levels. A separate study was conducted to evaluate the effects of two moisturizing formulations on skin hydration in laboratory studies with standard instrumentation and at home with Skinly. CONCLUSION: Thanks to its capability for multi-parameter measurements, the Skinly device, combined with its smartphone application, holds the potential to replace more expensive, time-consuming diagnostic tools. Collectively, the Skinly device opens new avenues in dermatological research, offering a reliable, versatile tool for comprehensive skin analysis.


Assuntos
Melanoma , Aplicativos Móveis , Neoplasias Cutâneas , Humanos , Inteligência Artificial , Pele/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico
16.
Skin Res Technol ; 30(3): e13632, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38407411

RESUMO

BACKGROUND: The Grand-AID research project, consisting of GRANDEL-The Beautyness Company, the dermatology department of Augsburg University Hospital and the Chair of IT Infrastructure for Translational Medical Research at Augsburg University, is currently researching the development of a digital skin consultation tool that uses artificial intelligence (AI) to analyze the user's skin and ultimately perform a personalized skin analysis and a customized skin care routine. Training the AI requires annotation of various skin features on facial images. The central question is whether videos are better suited than static images for assessing dynamic parameters such as wrinkles and elasticity. For this purpose, a pilot study was carried out in which the annotations on images and videos were compared. MATERIALS AND METHODS: Standardized image sequences as well as a video with facial expressions were taken from 25 healthy volunteers. Four raters with dermatological expertise annotated eight features (wrinkles, redness, shine, pores, pigmentation spots, dark circles, skin sagging, and blemished skin) with a semi-quantitative and a linear scale in a cross-over design to evaluate differences between the image modalities and between the raters. RESULTS: In the videos, most parameters tended to be assessed with higher scores than in the images, and in some cases significantly. Furthermore, there were significant differences between the raters. CONCLUSION: The present study shows significant differences between the two evaluation methods using image or video analysis. In addition, the evaluation of the skin analysis depends on subjective criteria. Therefore, when training the AI, we recommend regular training of the annotating individuals and cross-validation of the annotation.


Assuntos
Inteligência Artificial , Pele , Humanos , Elasticidade , Face/diagnóstico por imagem , Projetos Piloto , Pele/diagnóstico por imagem , Estudos Cross-Over
17.
Skin Res Technol ; 30(3): e13647, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38465749

RESUMO

BACKGROUND: Current methods for evaluating efficacy of cosmetics have limitations because they cannot accurately measure changes in the dermis. Skin sampling using microneedles allows identification of skin-type biomarkers, monitoring treatment for skin inflammatory diseases, and evaluating efficacy of anti-aging and anti-pigmentation products. MATERIALS AND METHODS: Two studies were conducted: First, 20 participants received anti-aging treatment; second, 20 participants received anti-pigmentation treatment. Non-invasive devices measured skin aging (using high-resolution 3D-imaging in the anti-aging study) or pigmentation (using spectrophotometry in the anti-pigmentation study) at weeks 0 and 4, and adverse skin reactions were monitored. Skin samples were collected with biocompatible microneedle patches. Changes in expression of biomarkers for skin aging and pigmentation were analyzed using qRT-PCR. RESULTS: No adverse events were reported. In the anti-aging study, after 4 weeks, skin roughness significantly improved in 17 out of 20 participants. qRT-PCR showed significantly increased expression of skin-aging related biomarkers: PINK1 in 16/20 participants, COL1A1 in 17/20 participants, and MSN in 16/20 participants. In the anti-pigmentation study, after 4 weeks, skin lightness significantly improved in 16/20 participants. qRT-PCR showed significantly increased expression of skin-pigmentation-related biomarkers: SOD1 in 15/20 participants and Vitamin D Receptor (VDR) in 15/20 participants. No significant change in TFAP2A was observed. CONCLUSION: Skin sampling and mRNA analysis for biomarkers provides a novel, objective, quantitative method for measuring changes in the dermis and evaluating the efficacy of cosmetics. This approach complements existing evaluation methods and has potential application in assessing the effectiveness of medical devices, medications, cosmeceuticals, healthy foods, and beauty devices.


Assuntos
Cosméticos , Transtornos da Pigmentação , Envelhecimento da Pele , Humanos , Pele/diagnóstico por imagem , Pigmentação da Pele , Biomarcadores
18.
Skin Res Technol ; 30(2): e13598, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38279588

RESUMO

BACKGROUND: While shaving-induced erythema is a common inflammatory skin issue, there is a lack of quantitative information on how well a shaving product performs in this regard. In this study, multispectral near-infrared spectroscopy (NIRS) imaging was used to quantitatively and qualitatively measure the extent of shaving-induced erythema. The research compares a safety razor and a cartridge razor to evaluate their impact on skin irritation. MATERIALS AND METHODS: Fifty-nine healthy male volunteers without pre-existing skin conditions were enrolled. Basic demographics were recorded, and participants' faces or necks were imaged before shaving. Shaving was conducted on the right side of the face/neck with the safety razor and on the left side of the face/neck using the 3-blade cartridge razor. Images were captured immediately after shaving, at 5 and 10 min post-shaving. RESULTS: Tissue oxygen saturation (StO2) measurements demonstrated that the safety razor induced significantly less erythema than the cartridge razor. Immediately after shaving, 40.3% of skin shaved with the safety razor had erythema compared to 57.6% for the cartridge razor. At 5 min post-shaving, 36.5% of skin shaved with the safety razor had erythema, compared to 53.8% of cartridge razor. CONCLUSIONS: Multispectral NIRS revealed significant differences in shaving-induced erythema between safety and cartridge razors. Safety razors demonstrated a lower incidence of erythema, suggesting a potential advantage for individuals prone to skin irritation. This study contributes valuable insights into skin irritation and highlights the potential of multispectral NIRS in dermatology research.


Assuntos
Remoção de Cabelo , Humanos , Masculino , Remoção de Cabelo/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Pele/diagnóstico por imagem , Eritema/diagnóstico por imagem
19.
Skin Res Technol ; 30(2): e13623, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38385854

RESUMO

BACKGROUND: Facial dark spots remain a significant challenge for the cosmetic industry, in terms of providing effective treatment. Using Line-field Confocal Optical Coherence Tomography (LC-OCT), we investigated the internal structural features of photo-aging spot areas and evaluated the efficacy of a skin-brightening cosmetic product. MATERIALS AND METHODS: Twenty-six Asian female volunteers, aged between 29 and 65 years, applied a cosmetic product on their entire face twice a day for 2 months. LC-OCT was used to evaluate the dermal-epidermal junction (DEJ) undulation and the volume density of melanin in the epidermis at D0 and D56. Skin brightening and redness were also assessed by photography (SkinCam). RESULTS: Using LC-OCT technology, various microscopic dark spot morphologies, spanning from minimally deformed DEJ to complex DEJ patterns, were identified. Dark spots characterized by slight deformities in the DEJ were predominantly observed in the youngest age group, while older volunteers displayed a wavier pattern. Furthermore, a total of 44 spots were monitored to evaluate the brightening product efficacy. A statistically significant reduction in melanin volumetric density of 7.3% in the spots and 12.3% in their surrounding area was observed after 56 days of product application. In line with these results, an analysis of color parameters using SkinCam reveals a significant increase in brightening and decrease in redness in both pigmented spots and the surrounding skin following application. CONCLUSIONS: LC-OCT proves to be a valuable tool for in-depth dark spots characterization and assessment of skin brightening products, enabling various applications in the field of dermatological sciences.


Assuntos
Melaninas , Transtornos da Pigmentação , Feminino , Humanos , Recém-Nascido , Tomografia de Coerência Óptica , Pele/diagnóstico por imagem , Epiderme/diagnóstico por imagem
20.
Skin Res Technol ; 30(4): e13684, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38558475

RESUMO

BACKGROUND: Hydradermabrasion, also known as "HydraFacial," is an exfoliative cosmetic procedure for skin rejuvenation that has gained popularity. Despite its increasing popularity, clinical studies validating its efficacy with non-invasive assessment of histological changes to the skin, are scarce. In this study, we used Line-Field Confocal Optical Coherence Tomography (LC-OCT), an optical imaging device, to non-invasively visualize microscopic changes to skin anatomy after hydradermabrasion treatment. MATERIALS/METHODS: Eight volunteers (Fitzpatrick skin types II-V) were recruited for this study. Images, using LC-OCT (DeepLive, DAMAE medical) were obtained before and after hydradermabrasion and at 2 weeks post-treatment. A commercially available hydradermabrasion device was utilized to perform the dermabrasion. RESULTS: In the epidermis, initially, a decrease in the average thickness of the stratum corneum, from 9.42 to 6.67 µm was visualized in LC-OCT images after hydradermabrasion. However, at 2 weeks of follow-up, the average stratum corneum thickness was 9.75 µm, resulting in an overall increase in the average thickness after treatment. Improved homogenization of the stratum corneum and decreased number of undulations in the epidermis post-treatment were also visualized. In all the subjects, the superficial dermis appeared stretched, which returned to baseline by the 2-week follow-up. At the 2-week follow-up, there were no visible differences in the quality and quantity of collagen fibers in the dermis. CONCLUSION: In our study, LC-OCT images of the epidermis and dermis demonstrated microscopic features of skin rejuvenation when treated with hydradermabrasion. Thus, not only highlighting the efficacy of hydradermabrasion but also the potential of LC-OCT to serve as a tool for visualizing the microscopic effects of cosmetic procedures on skin anatomy.


Assuntos
Pele , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Pele/diagnóstico por imagem , Pele/anatomia & histologia , Epiderme/diagnóstico por imagem , Epiderme/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA