Your browser doesn't support javascript.
loading
Localizing infection with a technetium-99m-labeled peptide: initial results.
Palestro, C J; Weiland, F L; Seabold, J E; Valdivia, S; Tomas, M B; Moyer, B R; Baran, Y M; Lister-James, J; Dean, R T.
Afiliação
  • Palestro CJ; Division of Nuclear Medicine of Long Island Jewish Medical Center, New Hyde Park, NY 11040, USA. palestro@lij.edu
Nucl Med Commun ; 22(6): 695-701, 2001 Jun.
Article em En | MEDLINE | ID: mdl-11403182
ABSTRACT
In vitro-labeled leukocyte imaging is useful for the detection of infection, but an in vivo labeling method is preferable. This study sought to evaluate the safety and efficacy of a leukocyte-avid peptide for the detection of infection, to determine the effects of peptide dose on performance and to compare the peptide with in vitro-labeled leukocytes. A 23-amino acid peptide, P483, containing the platelet factor-4 heparin-binding sequence, was labeled with 99mTc and complexed with heparin (P483H). Thirty patients were injected with 29 microg (n = 11), 145 microg (n = 10) or 290 microg (n = 9) of labeled peptide, and imaged 15 min and 90-120 min later. Early and late images were interpreted individually and jointly. Twenty patients underwent (111)In-labeled leukocyte scintigraphy. Fourteen patients had infection osteomyelitis (n = 7), vascular graft (n = 2), abscess (n = 2), joint replacement (n = 1), surgical wound (n = 1) and pneumonia (n = 1). There were 10 adverse events in six patients; all were mild and resolved spontaneously, and without any intervention. The sensitivity, specificity and accuracy were the same for both early and late imaging 0.86, 0.81 and 0.83, respectively. Interpreting early and late images together did not improve the results. No relationship between peptide dose and study accuracy was found. In patients undergoing both examinations, the accuracies of the peptide and in vitro-labeled leukocyte imaging were identical 0.80. In summary, 99mTc-P483H safely, rapidly and accurately detected focal infection, was comparable with in vitro-labeled leukocyte imaging and therefore merits further investigation.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas / Compostos de Organotecnécio / Compostos Radiofarmacêuticos / Infecções Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Nucl Med Commun Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas / Compostos de Organotecnécio / Compostos Radiofarmacêuticos / Infecções Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Nucl Med Commun Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos