Your browser doesn't support javascript.
loading
Coronary endothelial dysfunction after heart transplantation predicts allograft vasculopathy and cardiac death.
Hollenberg, S M; Klein, L W; Parrillo, J E; Scherer, M; Burns, D; Tamburro, P; Oberoi, M; Johnson, M R; Costanzo, M R.
Afiliação
  • Hollenberg SM; Section of Cardiology, Rush-Presbyterian-St Luke's Medical Center, Chicago, Illinois, USA.
Circulation ; 104(25): 3091-6, 2001 Dec 18.
Article em En | MEDLINE | ID: mdl-11748106
ABSTRACT

BACKGROUND:

Coronary endothelial dysfunction may be an early marker for cardiac allograft vasculopathy (CAV) in orthotopic heart transplant recipients. Using serial studies with intravascular ultrasound and Doppler flow-wire measurements, we have previously demonstrated that annual decrements in coronary endothelial function are associated with progressive intimal thickening. The present study tested whether endothelial dysfunction predicts subsequent clinical events, including cardiac death and CAV development. METHODS AND

RESULTS:

Seventy-three patients were studied yearly beginning at transplantation until a prespecified end point was reached. End points were angiographic evidence of CAV (>50% stenosis) or cardiac death (graft failure or sudden death). At each study, coronary endothelial function was measured with intracoronary infusions of adenosine (32-microgram bolus), acetylcholine (54 microgram over 2 minutes), and nitroglycerin (200 microgram) into the left anterior descending coronary artery; intravascular ultrasound images and Doppler velocities were recorded simultaneously. Of the 73 patients studied, 14 reached an end point during the study (6 CAV and 8 deaths, including 4 with known CAV, 1 graft failure, and 3 sudden). On the last study performed, the group with an end point had decreased epicardial (constriction of 11.1+/-2.9% versus dilation of 1.7+/-2.2%, P=0.01) and microvascular (flow increase of 75+/-20% versus 149+/-16%, P=0.03) endothelium-dependent responses to acetylcholine compared with the patients who did not reach an end point. Responses to adenosine and nitroglycerin did not differ significantly.

CONCLUSIONS:

Endothelial dysfunction, as detected by abnormal responses to acetylcholine, preceded the development of clinical end points. These data implicate endothelial dysfunction in the development of clinically significant vasculopathy and suggest that serial studies of endothelial function have clinical utility.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Endotélio Vascular / Transplante de Coração / Doença das Coronárias Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Circulation Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Endotélio Vascular / Transplante de Coração / Doença das Coronárias Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Circulation Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos