Change in full-field ERGs after macular translocation surgery with 360 degrees retinotomy.
Terasaki, Hiroko; Miyake, Yozo; Suzuki, Toshimitsu; Niwa, Takashi; Piao, Chang-Hua; Suzuki, Satoshi; Nakamura, Makoto; Kondo, Mineo.
Afiliação
  • Terasaki H; Department of Ophthalmology, Nagoya University School of Medicine, Nagoya, Japan. terasaki@med.nagoya-u.ac.jp
Invest Ophthalmol Vis Sci ; 43(2): 452-7, 2002 Feb.
Article em En | MEDLINE | ID: mdl-11818390
ABSTRACT

PURPOSE:

One of the methods used in macular translocation (MT) surgery for subfoveal neovascularization is to create a temporary total retinal detachment followed by a 360 degrees retinotomy. The whole retina is then shifted from the original surface of the retinal pigment epithelium (RPE), resulting in an unusual retina and RPE complex. The purpose of this study was to assess retinal function after MT surgery.

METHODS:

Full-field electroretinograms (ERGs) were recorded before and 4 to 8 months (mean, 5.4 months) after MT surgery with a 360 degrees retinotomy in 15 consecutive patients with age-related macular degeneration (10 eyes), high myopia (4 eyes), and polypoidal choroidal vasculopathy (1 eye). Their ages ranged from 57 to 74 years. The angle of rotation of the retina ranged from 18 degrees to 45 degrees (mean +/- SE, 30 +/- 2 degrees). In addition to the recording of the standard rod and mixed rod-cone ERGs after 30 minutes of dark adaptation, the cone single flash and 30-Hz flicker ERGs were recorded immediately after a light-adapting background was turned on (LA(0)) and also after 10 minutes of light adaptation (LA(10)).

RESULTS:

The mean amplitude of the full-field ERGs was reduced after surgery by 44% for the rod response, by 24% for the mixed rod-cone b-wave, by 12% and 35% for the cone single-flash b-wave at LA(0) and 30-Hz flicker ERGs at LA(0), respectively. The mean implicit times were delayed by 8 msec for the rod response, by 2 msec for the mixed rod-cone oscillatory potential (OP1), by 4 msec for the cone single-flash b-wave at LA(0), and by 6 msec for the 30-Hz flicker at LA(0).

CONCLUSIONS:

These results demonstrated a functional alteration in both the rod and cone components of the ERGs for the entire retina after MT surgery.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Fotorreceptoras de Vertebrados / Eletrorretinografia / Macula Lutea Tipo de estudo: Etiology_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Invest Ophthalmol Vis Sci Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Japão
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Fotorreceptoras de Vertebrados / Eletrorretinografia / Macula Lutea Tipo de estudo: Etiology_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Invest Ophthalmol Vis Sci Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Japão