Arterial puncture closing devices compared with standard manual compression after cardiac catheterization: systematic review and meta-analysis.
Koreny, Maria; Riedmüller, Eva; Nikfardjam, Mariam; Siostrzonek, Peter; Müllner, Marcus.
Afiliação
  • Koreny M; Department of Emergency Medicine, University of Vienna, Vienna General Hospital, Vienna, Austria.
JAMA ; 291(3): 350-7, 2004 Jan 21.
Article em En | MEDLINE | ID: mdl-14734598
ABSTRACT
CONTEXT Arterial puncture closing devices (APCDs) were developed to replace standard compression at the puncture site and to shorten bed rest following percutaneous coronary intervention.

OBJECTIVE:

To assess the safety and efficacy of APCDs (Angioseal, Vasoseal, Duett, Perclose, Techstar, Prostar) compared with standard manual compression in patients undergoing coronary angiography or percutaneous vascular interventions. DATA SOURCES A systematic literature search of MEDLINE (1966-January 2003), EMBASE (1989-January 2003), PASCAL (1996-January 2003), BIOSIS (1990-January 2003), and CINHAL (1982-January 2003) databases and the Cochrane Central Register of Controlled Trials for relevant articles in any language. STUDY SELECTION Included randomized controlled trials reporting vascular complications at the puncture site (hematoma, bleeding, arteriovenous fistula, pseudoaneurysm) and efficacy (time to hemostasis, time to ambulation, time to discharge from hospital). DATA EXTRACTION Two reviewers abstracted the data independently and in duplicate. Disagreements were resolved by discussion among at least 3 reviewers. The most important criteria were adequacy of allocation concealment, whether the analysis was according to the intention-to-treat principle, and if person assessing the outcome was blinded to intervention group. Random-effects models were used to pool the data. DATA

SYNTHESIS:

Thirty trials met the selection criteria and included up to 4000 patients. When comparing any APCD with standard compression, the relative risk (RR) of groin hematoma was 1.14 (95% confidence interval [CI], 0.86-1.51; P =.35); bleeding, 1.48 (95% CI, 0.88-2.48; P =.14); developing an arteriovenous fistula, 0.83 (95% CI, 0.23-2.94; P =.77); and developing a pseudoaneurysm at the puncture site, 1.19 (95% CI, 0.75-1.88; P =.46). Time to hemostasis was shorter in the group with APCD compared with standard compression (mean difference, 17 minutes; range, 14-19 minutes), but there was a high degree of heterogeneity among studies. Only 2 studies explicitly reported allocation concealment, blinded outcome assessment, and intention-to-treat analysis. When limiting analyses to only trials that used explicit intention-to-treat approaches, APCDs were associated with a higher risk of hematoma (RR, 1.89; 95% CI, 1.13-3.15) and a higher risk of pseudoaneurysm (RR, 5.40; 95% CI, 1.21-24.5).

CONCLUSIONS:

Based on this meta-analysis of 30 randomized trials, many of poor methodological quality, there is only marginal evidence that APCDs are effective and there is reason for concern that these devices may increase the risk of hematoma and pseudoaneurysm.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cicatrização / Cateterismo Periférico / Cateterismo Cardíaco / Punções / Técnicas Hemostáticas Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: JAMA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Áustria
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cicatrização / Cateterismo Periférico / Cateterismo Cardíaco / Punções / Técnicas Hemostáticas Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: JAMA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Áustria