Your browser doesn't support javascript.
loading
Enhanced electrokinetic extraction of heavy metals from soils assisted by ion exchange membranes.
Kim, Won-Seok; Kim, Soon-Oh; Kim, Kyoung-Woong.
Afiliação
  • Kim WS; Arsenic Geoenvironment Laboratory (NRL), Department of Environmental Science and Engineering, Gwangju Institute of Science and Technology, 1 Oryong-dong, Buk-gu, Gwangju 500-712, Republic of Korea.
J Hazard Mater ; 118(1-3): 93-102, 2005 Feb 14.
Article em En | MEDLINE | ID: mdl-15721533
ABSTRACT
The potential of electrokinetic remediation technology has been successfully demonstrated for the remediation of heavy metal contaminated fine-grained soils through laboratory scale and field application studies. Various enhancement techniques have been proposed and used in order to further improve the remediation process. However, it has been reported that such enhancement schemes can create other obstacles, such as the introduction of non-target ions into the system and thereby decrease the efficiency of the remediation process. Electrokinetic soil remediation technology enhanced by an ion exchange membrane (IEM), IEM-enhanced EK processing, was experimentally evaluated for the purpose of overcoming these obstacles. In particular, this study focused on observations of a fouling problem and its settlement using an auxiliary solution cell (ASC). In addition, the efficacies of two different types of electrode configurations, rectangular and cylindrical, were investigated. The experimental results indicate that the effectiveness of the technology was increased by an enhancement scheme using an IEM. This may be explained by the prevention of metal precipitation in the region near the cathode originating from hydroxide ions generated by the electrolysis of water in the cathode. The experimental results also imply that placement of the ASC can nullify the fouling problem within the cation exchange membranes used in IEM-enhanced EK processing, and thus improve the overall effectiveness of the process. The experimental results indicate that the cylindrical electrode configuration can be implemented in practical situations to improve the treatability of cathode effluent containing a high level of contaminants after processing.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes do Solo / Metais Pesados Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes do Solo / Metais Pesados Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2005 Tipo de documento: Article