Your browser doesn't support javascript.
loading
Determination of amiodarone and desethylamiodarone in horse plasma and urine by high-performance liquid chromatography combined with UV detection and electrospray ionization mass spectrometry.
Maes, A; Baert, K; Croubels, S; De Clercq, D; van Loon, G; Deprez, P; De Backer, P.
Afiliação
  • Maes A; Department of Pharmacology, Toxicology, Biochemistry and Organ Physiology, Ghent University, Salisburylaan 133, B-9820 Merelbeke, Belgium. an.maes@ugent.be
J Chromatogr B Analyt Technol Biomed Life Sci ; 836(1-2): 47-56, 2006 May 19.
Article em En | MEDLINE | ID: mdl-16616880
ABSTRACT
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Ultravioleta / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Amiodarona Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Bélgica
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Ultravioleta / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Amiodarona Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Bélgica