[Application of octopus 101 GKP kinetic and static automated perimetry in the diagnosis of the primary open angle glaucoma].
Zhong, Yong; Shi, Wei; Zhao, Peng; Ai, Feng-rong; Wang, Ren-yan.
Afiliação
  • Zhong Y; Department of Ophthalmology, PUMC Hospital, CAMS and PUMC, Beijing 100730, China. yzhong_eye@yahoo.com.cn
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 29(3): 413-7, 2007 Jun.
Article em Zh | MEDLINE | ID: mdl-17633473
ABSTRACT

OBJECTIVE:

To investigate the clinical significance of the Octopus 101 GKP kinetic and static automated perimetry in the diagnosis of the primary open angle glaucoma (POAG).

METHODS:

Thirty POAG patients (POAG group) and 34 normal individuals (control group) were detected with Octopus 101 GKP static and kinetic perimetry with GKP and TOP program from October 2006 to March 2007. The visual acuity, intraocular pressure (IOP), cupping/disc (C/D) ratio, mean defect (MD), loss variance (LV), areas of isopter, and testing time were analyzed.

RESULTS:

The mean visual acuity, mean IOP and mean C/D ratio were significantly different between POAG group and control group (P = 0.000), and so was the testing time (P = 0.001). The mean test time was (307.78 +/- 134.50) s in the POAG group and was (228.12 +/- 75.33) s in the normal group. No linear correlation was found between the IOP and the areas of isopter or MD between these two group. The visual parameters (I 2e and III 4e) as to the areas of isopter of POAG were significantly different (P = 0.000), and so were the MD, LV and areas of isopter (P = 0.000). Static perimetry had a sensitivity of 80% and a specificity of 45%, and kinetic perimetry had a sensitivity of 86% and a specificity of 63%. The combined method of static and kinetic approaches had a sensitivity of 90%.

CONCLUSIONS:

The Octopus 101 GKP static and kinetic perimetry can perform an automated test that combines the advantages of both kinetic and static perimetry, resulting in a decreased subjectivity and individual difference by adjusting the response time and improved accuracy of test results. By changing stimulus size, background illumination, and stimulus angular velocity, the combination of the kinetic and static test may provide a higher sensitivity in the diagnosis of the early stage of POAG, particularly in patients with early peripheral visual field defect.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Aberto / Testes de Campo Visual Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: Zh Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2007 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Aberto / Testes de Campo Visual Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: Zh Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2007 Tipo de documento: Article País de afiliação: China