Hypothalamus-pituitary-adrenal axis evaluation in patients with hypothalamo-pituitary disorders: comparison of different provocative tests.
Giordano, R; Picu, A; Bonelli, L; Balbo, M; Berardelli, R; Marinazzo, E; Corneli, G; Ghigo, E; Arvat, E.
Afiliação
  • Giordano R; Division of Endocrinology and Metabolism, Department of Internal Medicine, University of Turin, Turin, Italy.
Clin Endocrinol (Oxf) ; 68(6): 935-41, 2008 Jun.
Article em En | MEDLINE | ID: mdl-18031311
ABSTRACT

BACKGROUND:

The insulin tolerance test (ITT) is the gold standard test to evaluate hypothalamic-pituitary-adrenal (HPA) axis in suspected ACTH insufficiency. When contraindicated, alternative tests have been proposed such as metyrapone and ACTH stimulation test. 250 microg ACTH is a supramaximal dose and unreliable in this setting. The diagnostic reliability of 1.0 microg ACTH test is controversial and very low doses have been proposed.

DESIGN:

In 31 patients with hypothalamo-pituitary disorders and normal basal cortisol, we compared the diagnostic sensitivity, specificity and accuracy of metyrapone [metyrapone test (MET) 30 mg/kg p.o.], high (HDT, 250 microg i.v.), low (LDT, 1.0 microg i.v.) and very-low (VLDT, 0.06 microg i.v.) dose ACTH tests. Receiver operator curve (ROC) analysis was applied with ITT as reference test.

RESULTS:

MET approached the best pairs of values for highest sensitivity (71.4% and 64.3%) and highest specificity (100% and 82.4%) using ACTH and 11-deoxycortisol (11-DOC) cut-off of 17.3 pmol/l and 144.3 nmol/l. Either HDT or LDT sensitivity approached 71.4% with a specificity of 82.4% or 73.3% with a specificity of 80% for cortisol cut-off of 582.1 or 477.3 nmol/l. VLDT approached the highest sensitivity (57.1%) and highest specificity (88.2%) for a cortisol cut-off of 364.2 nmol/l.

CONCLUSION:

Neither MET nor ACTH test can be considered completely reliable for the diagnosis of secondary hypoadrenalism, when compared with ITT that remains the best test. Either MET or ACTH stimulation test, at both high and low dose, show an overall similar reliability, provided that appropriated cut-off values were considered; testing with very low ACTH doses seems to be misleading.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema Hipófise-Suprarrenal / Hormônio Adrenocorticotrópico / Doenças Hipotalâmicas / Sistema Hipotálamo-Hipofisário / Metirapona Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Endocrinol (Oxf) Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Itália
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema Hipófise-Suprarrenal / Hormônio Adrenocorticotrópico / Doenças Hipotalâmicas / Sistema Hipotálamo-Hipofisário / Metirapona Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Endocrinol (Oxf) Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Itália