Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge.
van Eck, Jacob W M; van Hemel, Norbert M; de Voogt, Willem G; Meeder, Joan G; Spierenburg, Hans A; Crommentuyn, Har; Keijzer, Rens; Grobbee, Diederick E; Moons, Karel G M.
Afiliação
  • van Eck JW; Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Bolognalaan 12, 3584 CJ Utrecht, The Netherlands. j.w.m.vaneck-2@umcutrecht.nl
Europace ; 10(7): 832-7, 2008 Jul.
Article em En | MEDLINE | ID: mdl-18420650
ABSTRACT

AIMS:

To describe current evidence of the frequency, contents, and involved professionals of the routine follow-up visits in patients who have received a pacemaker (PM). METHODS AND

RESULTS:

The multicentre FOLLOWPACE study prospectively collected data during implantation and follow-up of 1526 patients who received a PM for the first time. A total of 4914 follow-up visits were studied. Mean follow-up was 394 days with a mean of 3.2 visits per patient. At all follow-up visits, the battery condition was tested in >93%, the stimulation threshold in >91%, and sensing in >87%. The pacemaker parameters as stimulation and sensing thresholds, lead impedances, and percentages of pacing remained stable over time, but these values did depend on the lead location, lead fixation, and pulse duration. The majority of PM (re-)programming was performed during implantation and/or shortly before hospital discharge (50%). PM re-programming during follow-up was most frequently performed by the PM technician alone (95%).

CONCLUSION:

Crucial PM parameters are regularly checked. Re-programming of PM parameters declined during the first year after PM implantation. The majority of PM checks were carried out by the PM technician, indicating the major influence of the allied professional on the quality and safety of the pacing therapy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Monitorização Ambulatorial Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Monitorização Ambulatorial Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Holanda