Your browser doesn't support javascript.
loading
Assessment of public doses due to a neutron calibration bunker.
Suman, H; Kharita, M H; Yousef, S.
Afiliação
  • Suman H; Radiological and Nuclear Regulatory Office, Atomic Energy Commission, Damascus ,PO Box 6091, Syria.
Radiat Prot Dosimetry ; 138(4): 340-5, 2010 Mar.
Article em En | MEDLINE | ID: mdl-19946121
In this work, the expected neutron and gamma doses in the populated areas outside the newly constructed neutron calibration bunker at the Atomic Energy Commission of Syria will be assessed using the Monte Carlo code MCNP-4C2. The results showed that the maximum ambient dose equivalent rate (neutrons and gammas) outside the bunker would not exceed 0.5 microSv h(-1), assuming an Am-Be neutron source of emission rate of 10(8) n s(-1). The neutron dose is approximately 10 times higher than the photon dose. Sky shine contributes by about 25-50% of the neutron dose and 7-27% of the gamma dose, depending on the location. The simulation uncertainty due to the possible variations in the simulation parameters has been given particular importance.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Doses de Radiação / Espalhamento de Radiação / Calibragem / Método de Monte Carlo / Nêutrons Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Síria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Doses de Radiação / Espalhamento de Radiação / Calibragem / Método de Monte Carlo / Nêutrons Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Síria