In this work, the expected neutron and gamma doses in the populated areas outside the newly constructed neutron calibration bunker at the Atomic Energy Commission of Syria will be assessed using the Monte Carlo code MCNP-4C2. The results showed that the maximum ambient dose equivalent rate (neutrons and gammas) outside the bunker would not exceed 0.5 microSv h(-1), assuming an Am-Be neutron source of emission rate of 10(8) n s(-1). The neutron dose is approximately 10 times higher than the photon dose. Sky shine contributes by about 25-50% of the neutron dose and 7-27% of the gamma dose, depending on the location. The simulation uncertainty due to the possible variations in the simulation parameters has been given particular importance.