Your browser doesn't support javascript.
loading
CT-guided needle biopsy performed with modified coaxial technique in the diagnosis of malignant lymphomas.
Pedote, P; Gaudio, F; Moschetta, M; Cimmino, A; Specchia, G; Angelelli, G.
Afiliação
  • Pedote P; Di.M.I.M.P. - Sezione di Diagnostica per Immagini, Policlinico Universitario, Piazza Giulio Cesare 11, Bari, Italy. pasqpedo@tin.it
Radiol Med ; 115(8): 1292-303, 2010 Dec.
Article em En, It | MEDLINE | ID: mdl-20574704
ABSTRACT

PURPOSE:

The aim of was study was to evaluate the accuracy of computed tomography (CT)-guided core needle biopsy (CNB) performed by modified coaxial technique as an alternative tool to surgical biopsy in patients with suspected malignant lymphoma. MATERIALS AND

METHODS:

Between May 2005 and December 2008, 67 CT-guided CNB of deep lesions were performed on 64 patients with suspected malignant lymphoma. In 19 out of 64 patients (29.7%), recurrent lymphoma was suspected. A modified coaxial technique was used in all cases, and multiple samples were obtained for histological and immunohistochemical studies.

RESULTS:

A diagnosis of malignant lymphomas with specification of subtype according to the World Health Organization (WHO) classification was established in 41/67 cases. Other malignant neoplasms were found in 13/67, lymphoma without subtype specification was diagnosed in 7/67, whereas no conclusive diagnosis could be established in 6/67 cases. Overall diagnostic accuracy was 80.1%. In patients with a final diagnosis of malignant lymphoma, accuracy was 75.9%. No complications occurred.

CONCLUSIONS:

Percutaneous CT-guided CNB is a safe, effective and reliable tool in the management of lymphomas in patients without superficial lymphadenopathy and can be considered an alternative approach to surgical sampling. The modified coaxial technique represents an effective tool that has a good diagnostic accuracy value with a low complication rate.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biópsia por Agulha / Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Linfoma Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En / It Revista: Radiol Med Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biópsia por Agulha / Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Linfoma Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En / It Revista: Radiol Med Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Itália