Your browser doesn't support javascript.
loading
Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease.
Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun; Ivanc, Thomas B; Vembar, Mani.
Afiliação
  • Huang MP; Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou, People's Republic of China.
Pediatr Radiol ; 41(7): 858-66, 2011 Jul.
Article em En | MEDLINE | ID: mdl-21534003
ABSTRACT

BACKGROUND:

There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD).

OBJECTIVE:

To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. MATERIALS AND

METHODS:

From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight 60 mAs for ≤ 3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg).

RESULTS:

No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 ± 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 ± 2.2/min (range, 0-8). Mean scan length was 115.3 ± 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 ± 0.4 mGy (range, 1.5-2.8), 24.7 ± 5.9 mGy·cm (range, 14.7-35.8) and 1.6 ± 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans.

CONCLUSION:

Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Angiografia Coronária / Técnicas de Imagem de Sincronização Cardíaca / Cardiopatias Congênitas Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Female / Humans / Infant / Male / Newborn Idioma: En Revista: Pediatr Radiol Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Angiografia Coronária / Técnicas de Imagem de Sincronização Cardíaca / Cardiopatias Congênitas Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Female / Humans / Infant / Male / Newborn Idioma: En Revista: Pediatr Radiol Ano de publicação: 2011 Tipo de documento: Article